PubMed Health⌕ Search

Biomedical subjects

Max J Lab

Publications and source records attributed to Max J Lab.

6 recordsLinked to original sources

Esmolol is antiarrhythmic in doxorubicin-induced arrhythmia in cultured cardiomyocytes - determination by novel rapid cardiomyocyte assay.

Cardiac toxicity is an uncommon but potentially serious complication of cancer therapy, especially with anthracyclines. One of the most effective anticancer drugs is doxorubicin, but its value is limited by the risk of developing cardiomyopathy and ventricular arrhythmia. When applied to a network of periodically contracting cardiomyocytes in culture, doxorubicin induces rhythm disturbances. Using a novel rapid assay based on non-invasive ion-conductance microscopy we show that the beta-antagonist esmolol can restore rhythm in doxorubicin-treated cultures of cardiomyocytes. Moreover, esmolol pre-treatment can protect the culture from doxorubicin-induced arrhythmia.

Adrenergic beta-Antagonists↗

Right ventricular myocardial responses to chronic pulmonary regurgitation in lambs: disturbances of activation and conduction.

Patients after repair of tetralogy of Fallot are at increased risk of arrhythmic death. Clinical data suggest that pulmonary regurgitation predisposes to these arrhythmias, although the cellular electrophysiologic effects of pulmonary regurgitation are unknown. We induced pulmonary regurgitation in lambs, and 3 mo later, having quantified the pulmonary regurgitant (PR) fraction, studied right ventricular mechanical and electrophysiologic properties in vivo and in vitro. The PR fraction was greater in PR (75 +/- 10%) than in sham-operated animals (8 +/- 4%; p < 0.01). In vivo, monophasic action potential duration and activation time, at rest and during acute right ventricular stretch, were similar in both groups. However, the dispersion of activation time was greater in PR animals at rest (13 +/- 1.1 versus 8 +/- 1.1 ms; p < 0.05). Furthermore, the dispersion of activation increased during right ventricular stretch in PR, but not in sham-operated animals. In vitro, myocardial force-frequency responses were similar in both groups, indicating preserved systolic performance, but mechanical restitution studies showed a prolonged refractory period (447 +/- 22 versus 370 +/- 26 ms; p < 0.05) and a decreased recovery time constant (184 +/- 19 versus 265 +/- 20 ms; p < 0.001) in PR animals, indicating altered calcium cycling. Furthermore, the myocardial conduction velocity was reduced in PR animals (31 +/- 3.58 versus 47.9 +/- 5.1 cm/s; p < 0.01), resulting from a 2-fold increase in intracellular resistance (437.25 +/- 125.93 versus 194 +/- 43.27 Omega. cm; p = 0.025). Chronic PR leads to inhomogeneity of right ventricular activation, alters myocardial calcium cycling, reduces conduction velocity, and increases intracellular resistivity. These may contribute to the development of arrhythmias associated with PR, including those in patients after tetralogy repair.

Animals↗

Dynamic assembly of surface structures in living cells.

Although the dynamics of cell membranes and associated structures is vital for cell function, little is known due to lack of suitable methods. We found, using scanning ion conductance microscopy, that microvilli, membrane projections supported by internal actin bundles, undergo a life cycle: fast height-dependent growth, relatively short steady state, and slow height-independent retraction. The microvilli can aggregate into relatively stable structures where the steady state is extended. We suggest that the intrinsic dynamics of microvilli, combined with their ability to make stable structures, allows them to act as elementary "building blocks" for the assembly of specialized structures on the cell surface.

Animals↗

Scanning surface confocal microscopy for simultaneous topographical and fluorescence imaging: application to single virus-like particle entry into a cell.

We have developed a method for simultaneous recording of high-resolution topography and cell surface fluorescence in a single scan which we call scanning surface confocal microscopy. The resolution of the system allows imaging of individual fluorescent particles in the nanometer range on fixed or live cells. We used this technique to record the interaction of single virus-like particles with the cell surface and demonstrated that single particles sink into the membrane in invaginations reminiscent of caveolae or pinocytic vesicles. This method provides a technique for elucidating the interaction of individual viruses and other nanoparticles, such as gene therapy vectors, with target cells. Furthermore, this technique should find widespread application for studying the relationship of fluorescently tagged molecules with components of the cell plasma membrane.

Animals↗

High-resolution scanning patch-clamp: new insights into cell function.

Cell specialization is often governed by the spatial distribution of ion channels and receptors on the cell surface. So far, little is known about functional ion channel localization. This is due to a lack of satisfactory methods for investigating ion channels in an intact cell and simultaneously determining the channels' positions accurately. We have developed a novel high-resolution scanning patch-clamp technique that enables the study of ion channels, not only in small cells, such as sperm, but in submicrometer cellular structures, such as epithelial microvilli, fine neuronal dendrites, and, particularly, T-tubule openings of cardiac myocytes. In cardiac myocytes, as in most excitable cells, action potential propagation depends essentially on the properties of ion channels that are functionally and spatially coupled. We found that the L-type calcium and chloride channels are distributed and colocalized in the region of T-tubule openings, but not in other regions of the myocyte. In addition, chloride channels were found in narrowly defined regions of Z-grooves. This finding suggests a new synergism between these types of channels that may be relevant for action potential propagation along the T-tubule system and excitation-contraction coupling.

Animals↗

Ion channels in small cells and subcellular structures can be studied with a smart patch-clamp system.

We have developed a scanning patch-clamp technique that facilitates single-channel recording from small cells and submicron cellular structures that are inaccessible by conventional methods. The scanning patch-clamp technique combines scanning ion conductance microscopy and patch-clamp recording through a single glass nanopipette probe. In this method the nanopipette is first scanned over a cell surface, using current feedback, to obtain a high-resolution topographic image. This same pipette is then used to make the patch-clamp recording. Because image information is obtained via the patch electrode it can be used to position the pipette onto a cell with nanometer precision. The utility of this technique is demonstrated by obtaining ion channel recordings from the top of epithelial microvilli and openings of cardiomyocyte T-tubules. Furthermore, for the first time we have demonstrated that it is possible to record ion channels from very small cells, such as sperm cells, under physiological conditions as well as record from cellular microstructures such as submicron neuronal processes.

Animals↗