PubMed Health⌕ Search

Biomedical subjects

Max Schöbinger

Publications and source records attributed to Max Schöbinger.

4 recordsLinked to original sources

Assessment of reproducibility and stability of different breath-hold maneuvres by dynamic MRI: comparison between healthy adults and patients with pulmonary hypertension.

To assess the stability and reproducibility of different breath-hold levels in healthy volunteers and patients using dynamic MRI (dMRI). In ten healthy volunteers and ten patients with pulmonary hypertension (PH) and normal lung function craniocaudal intrathoracic distances (CCD) were measured during inspiratory and expiratory breath-hold (15 s) (in healthy volunteers additionally at a self-chosen mid-inspiratory breath-hold) using dMRI (trueFISP, three images/s). To evaluate stability and intraobserver reproducibility of the different breath-hold levels, CCDs, time-distance curves, confidence intervals (CIs), Mann-Witney U test and regression equations were calculated. In healthy volunteers there was a substantial decrease of the CCD during the inspiratory breath-hold in contrast to the expiratory breath-hold. The CI at inspiration was 2.84+/-1.28 in the right and 2.1+/-0.68 in the left hemithorax. At expiration the CI was 2.54+/-1.18 and 2.8+/-1.48. Patients were significantly less able to hold their breath at inspiration than controls (P<0.05). In patients CI was 4.53+/-4.06 and 3.46+/-2.21 at inspiration and 4.45+/-4.23 and 4.76+/-3.73 at expiration. Intraobserver variability showed no significant differences either in patients or in healthy subjects. Reproducibility was significantly lower at a self-chosen breath-hold level of the healthy volunteers. DMRI is able to differentiate stability and reproducibility of different breath-hold levels. Expiratory breath-hold proved to be more stable than inspiratory breath-hold in healthy volunteers and patients.

Adult↗

Influence of different breathing maneuvers on internal and external organ motion: use of fiducial markers in dynamic MRI.

PURPOSE: To investigate, with dynamic magnetic resonance imaging (dMRI) and a fiducial marker, the influence of different breathing maneuvers on internal organ and external chest wall motion. METHODS AND MATERIALS: Lung and chest wall motion of 16 healthy subjects (13 male, 3 female) were examined with real-time trueFISP (true fast imaging with steady-state precession) dMRI and a small inductively coupled marker coil on either the abdomen or thorax. Three different breathing maneuvers were performed (predominantly "abdominal breathing," "thoracic breathing," and unspecific "normal breathing"). The craniocaudal (CC), anteroposterior (AP), and mediolateral (ML) lung distances were correlated (linear regression coefficient) with marker coil position during forced and quiet breathing. RESULTS: Differences of the CC distance between maximum forced inspiration and expiration were significant between abdominal and thoracic breathing (p < 0.05). The correlation between CC distance and coil position was best for forced abdominal breathing and a marker coil in the abdominal position (r = 0.89 +/- 0.04); for AP and ML distance, forced thoracic breathing and a coil in the thoracic position was best (r = 0.84 +/- 0.03 and 0.82 +/- 0.03, respectively). In quiet breathing, a lower correlation was found. CONCLUSION: A fiducial marker coil external to the thorax in combination with dMRI is a new technique to yield quantitative information on the correlation of internal organ and external chest wall motion. Correlations are highly dependent on the breathing maneuver.

Abdomen↗

The segments of the hepatic veins-is there a spatial correlation to the Couinaud liver segments?

PURPOSE: To investigate and describe the volume, position and shape of venous segments within the human liver and define their spatial correlation to the Couinaud segments (CS) and to the portal vein segments (PVS). MATERIAL AND METHODS: This study was based on 64 routinely acquired CT scans of patients undergoing hepatic surgery. The final analysis included 19 patients. All 19 CT data sets were transformed into 3D liver models. Three venous segments were postulated reflecting the left, middle, and right hepatic vein. Each venous segment was furthermore divided in two venous subsegments. Volume, position and shape of these venous segments/subsegments were calculated and, finally, compared with the volume, position and shape of the Couinaud segments and the portal vein segments. RESULTS: The right hepatic vein covers with 539.8 +/- 119.5 ml (47.1%) the largest part of total liver volume followed by the middle hepatic vein 372.7 +/- 151.1 ml (32.5%) and the left hepatic vein 248 +/- 75.9 ml (20.4%). The Couinaud liver segments and portal vein segments 2, 3, 5, 7, and 8 have consistent positional assignments within the three venous segments. Only the CS 4a, 4b, and 6 showed significantly different positions compared to the PVS 4a, 4b, and 6 (P < 0.03). The venous subsegments have a broad volumetric distribution reaching from 79 to 337 ml. There is no positional correlation of venous subsegments compared to Couinaud segments or portal vein segments at all (kappa < 0.75). In contrast, the venous segments/subsegments which can be assigned to either liver halve and either liver lobe have an identical volume, shape and position compared to the corresponding Couinaud liver segments (kappa > 0.75). CONCLUSION: The venous segments distinguish liver areas divided by the left and middle hepatic vein in exactly the same pattern as Couinaud segments and portal vein segments do. However, the comparison of shape and position of venous subsegments showed no correlation with both liver segmental approaches.

Adult↗

The medical imaging interaction toolkit.

Thoroughly designed, open-source toolkits emerge to boost progress in medical imaging. The Insight Toolkit (ITK) provides this for the algorithmic scope of medical imaging, especially for segmentation and registration. But medical imaging algorithms have to be clinically applied to be useful, which additionally requires visualization and interaction. The Visualization Toolkit (VTK) has powerful visualization capabilities, but only low-level support for interaction. In this paper, we present the Medical Imaging Interaction Toolkit (MITK). The goal of MITK is to significantly reduce the effort required to construct specifically tailored, interactive applications for medical image analysis. MITK allows an easy combination of algorithms developed by ITK with visualizations created by VTK and extends these two toolkits with those features, which are outside the scope of both. MITK adds support for complex interactions with multiple states as well as undo-capabilities, a very important prerequisite for convenient user interfaces. Furthermore, MITK facilitates the realization of multiple, different views of the same data (as a multiplanar reconstruction and a 3D rendering) and supports the visualization of 3D+t data, whereas VTK is only designed to create one kind of view of 2D or 3D data. MITK reuses virtually everything from ITK and VTK. Thus, it is not at all a competitor to ITK or VTK, but an extension, which eases the combination of both and adds the features required for interactive, convenient to use medical imaging software. MITK is an open-source project (www.mitk.org).

Algorithms↗