2D axial moving table acquisitions with dynamic slice adaptation.

A method for axial multi-slice imaging during continuous table motion has been developed and implemented on a clinical scanner. Multiple axial slice packages are acquired consecutively and combined to cover an extended longitudinal FOV. To account for the table motion during the acquisition, the RF pulse frequencies are continuously updated according to the actual table velocity and slice position. Different strategies for the spatial-temporal acquisition sequence with extended FOV are proposed. They cover different regimes of scan requirements regarding table velocity, used scan range, and slice resolution. The method is easy to implement and compatible with most kinds of sequences. The robustness of the proposed approach has been tested in phantom studies and healthy volunteers using T1-, T2-, and STIR-weighted multi-slice techniques that are based on gradient and turbo spin echo sequences and compared to a stationary approach usually used in clinical routine. The method provides artifact free gradient echo based images during continuous table motion, while for turbo spin echo sequences limitations in choosing table translations occur due to gradient non-linearity effects.

Algorithms↗

Navigator gated high temporal resolution tissue phase mapping of myocardial motion.

Data acquisition for phase contrast velocity mapping of myocardial motion is typically based on multiple breath-held 2D measurements with limited acquisition duration and consequently relatively poor temporal resolution. In order to overcome the limitations of breath-hold acquisitions, an improved navigator-guided technique was implemented based on 2 navigator signals within each cardiac cycle in combination with paired acceptance and rejection criteria of successive navigator signals. Respiratory gated phase contrast measurements with 3-directional velocity encoding were performed in 12 healthy volunteers in basal, midventricular, and apical locations of the left ventricle during free breathing with a temporal resolution of 13.8 ms. Results were compared to standard breath-hold measurements with a temporal resolution of 69 ms. Data from the high temporal resolution study revealed details in left ventricular motion patterns that were previously not seen in phase contrast measurements and are only known from echocardiography. The proposed navigator gated technique for high temporal resolution velocity mapping is, therefore, highly promising for the detection of local and global motion abnormalities in patients with disturbed left ventricular performance, such as diastolic dysfunction.

Adult↗

Intrinsic fat suppression in TIDE balanced steady-state free precession imaging.

A novel fat-suppressed balanced steady-state free precession (b-SSFP) imaging method based on the transition into driven equilibrium (TIDE) sequence with variable flip angles is presented. The new method, called fat-saturated (FS)-TIDE, exploits the special behavior of TIDE signals from off-resonance spins during the flip angle ramp. As shown by simulations and experimental data, the TIDE signal evolution for off-resonant isochromats during the transition from turbo spin-echo (TSE)-like behavior to the true fast imaging with steady precession (TrueFISP) mode undergoes a zero crossing. The resulting signal notch for off-resonant spins is then used for fat suppression. The efficiency of FS-TIDE is demonstrated in phantoms and healthy volunteers on a 1.5T system. The resulting images are compared with standard TrueFISP data with and without fat suppression. It is demonstrated that FS-TIDE provides a fast and stable means for homogenous fat suppression in abdominal imaging while maintaining balanced SSFP-like image contrast and signal-to-noise ratio (SNR). The scan time of FS-TIDE is not increased compared to normal TrueFISP imaging without fat suppression and identical k-space trajectories. Because of the intrinsic fat suppression, no additional preparation is needed. Possible repetition times (TRs) are not firmly limited to special values and are nearly arbitrary.

Adipose Tissue↗

Advantages and limitations of prospective head motion compensation for MRI using an optical motion tracking device.

RATIONALE AND OBJECTIVES: Subject motion appears to be a limiting factor in numerous magnetic resonance (MR) imaging (MRI) applications. In particular, head tremor, which often accompanies stroke, may render certain high-resolution two- (2D) and three-dimensional (3D) techniques inapplicable. The reason for that is head movement during acquisition. The study objective is to achieve a method able to compensate for complete motion during data acquisition. The method should be usable for every sequence and easily implemented on different MR scanners. MATERIALS AND METHODS: The possibility of interfacing the MR scanner with an external optical motion-tracking system capable of determining the object's position with submillimeter accuracy and an update rate of 60 Hz is shown. Movement information on the object position (head) is used to compensate for motion in real time by updating the field of view (FOV) by recalculating the gradients and radiofrequency parameter of the MR scanner during acquisition of k-space data, based on tracking data. RESULTS: Results of rotation phantom, in vivo experiments, and implementation of three different MRI sequences, 2D spin echo, 3D gradient echo, and echo planar imaging, are presented. Finally, the proposed method is compared with the prospective motion correction software available on the scanner software. CONCLUSION: A prospective motion correction method that works in real time only by updating the FOV of the MR scanner is presented. Results show the feasibility of using an external optical motion-tracking system to compensate for strong and fast subject motion during acquisition.

Algorithms↗

Prospective head motion compensation for MRI by updating the gradients and radio frequency during data acquisition.

Subject motion appears to be a limiting factor in numerous magnetic resonance imaging (MRI) applications. For head imaging the subject's ability to maintain the same head position for a considerable period of time places restrictions on the total acquisition time. For healthy individuals this time typically does not exceed 10 minutes and may be considerably reduced in case of pathology. In particular, head tremor, which often accompanies stroke, may render certain high-resolution 2D and 3D techniques inapplicable. Several navigator techniques have been proposed to circumvent the subject motion problem. The most suitable for head imaging appears to be the orbital or spherical navigator methods. Navigators, however, not only lengthen the measurement because of the time required for acquisition of the position information, but also require additional excitation radio frequency (RF) pulses to be incorporated into the sequence timing, which disturbs the steady state. Here we demonstrate the possibility of interfacing the MR scanner with an external optical motion tracking system, capable of determining the object's position with sub-millimeter accuracy and an update rate of 60Hz. The movement information on the object position (head) is used to compensate the motion in real time. This is done by updating the field of view (FOV) by recalculating the gradients and the RF-parameter of the MRI tomograph during the acquisition of k-space data based on the tracking data. Results of rotation phantom, in vivo experiments and the implementation in two different MRI sequences are presented.

Artifacts↗

Quantitative T1 mapping of hepatic encephalopathy using magnetic resonance imaging.

Changes are shown in the spin-lattice (T1) relaxation time caused by the putative deposition of manganese in various brain regions of hepatic encephalopathy (HE) patients using a novel and fast magnetic resonance imaging (MRI) method for quantitative relaxation time mapping. A new method, T1 mapping with partial inversion recovery (TAPIR), was used to obtain a series of T1-weighted images to produce T1 maps. Imaging of 15 control subjects and 11 patients was performed on a 1.5T MRI scanner. The measurement time per patient with this technique, including adjustments, was approximately 5 minutes. Regions of interest in the globus pallidus, the caudate nucleus, the posterior and anterior limbs of the internal capsule, the putamen, the frontal and occipital white matter, the white matter of the corona radiata, the occipital visual and frontal cortices, and the thalamus were interactively defined in the left hemisphere and analyzed with respect to their T1 values. T1 changes in the brains of HE patients can be determined quantitatively with TAPIR in short, clinically relevant measurement times. Significant correlations between the change in T1 and HE severity have been shown in the globus pallidus, the caudate nucleus, and the posterior limb of the internal capsule. No significant correlation of T1 with grade of HE was found in the putamen, frontal white matter, white matter of the corona radiata, white matter in the occipital lobe, the anterior limb of the internal capsule, visual cortex, thalamus, or frontal cortex. In conclusion, these measurements show that T1 mapping is feasible in short, clinically relevant acquisition times.