PubMed Health⌕ Search

Biomedical subjects

Maximilian F Reiser

Publications and source records attributed to Maximilian F Reiser.

At least 19 recordsLinked to original sources

Multidetector-row computed tomography of the coronary arteries: predictive value and quantitative assessment of non-calcified vessel-wall changes.

The aim of this study was to quantitatively assess non-calcified coronary artery plaques and to determine their predictive value for the detection of coronary artery disease (CAD). A total of 179 patients underwent a calcium screening examination and a contrast-enhanced multidetector-row computed tomography angiography (MDCT) of the coronary arteries for various indications. The traditional calcium scores were evaluated and all examinations were reviewed for the presence of non-calcified plaques with an attenuation of 0-130 Hounsfield units (HU). The number, mean attenuation, and volume of these non-calcified plaques were recorded. All patients also underwent conventional catheter angiography. Coronary calcium was detected in 73% (131 of 179) of the patients. Overall incidence of purely non-calcified plaques was 30% (53 of 179). In 27% of the patients (48 of 179) no calcium was detected; however, 15% of these patients without calcifications showed non-calcified plaques (7 of 48). Significant correlations were found between the volume of calcified plaques, volume of non-calcified plaques, and total plaque volume. There were significant differences in plaque composition comparing different risk factor profiles and different stages of CAD. Volumetric assessment of non-calcified coronary artery plaques is feasible using contrast-enhanced MDCT. Screening for non-calcified plaques identifies patients with signs of CAD that are missed in a calcium screening examination.

Calcinosis↗

Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm.

The purpose of this study was to test parallel imaging techniques for improvement of temporal resolution in multislice single breath-hold real-time cine steady-state free precession (SSFP) in comparison with standard segmented single-slice SSFP techniques. Eighteen subjects were examined on a 1.5-T scanner using a multislice real-time cine SSFP technique using the GRAPPA algorithm. Global left ventricular parameters (EDV, ESV, SV, EF) were evaluated and results compared with a standard segmented single-slice SSFP technique. Results for EDV ( r=0.93), ESV ( r=0.99), SV ( r=0.83), and EF ( r=0.99) of real-time multislice SSFP imaging showed a high correlation with results of segmented SSFP acquisitions. Systematic differences between both techniques were statistically non-significant. Single breath-hold multislice techniques using GRAPPA allow for improvement of temporal resolution and for accurate assessment of global left ventricular functional parameters.

Algorithms↗

Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating.

The aim of this study was to reduce radiation exposure in multislice CT (MSCT) coronary artery calcium screening using different tube settings, and to determinate its impact on the detection and quantification of coronary artery calcification. Forty-eight patients underwent routine MSCT coronary artery calcium scoring (Somatom VolumeZoom, Siemens, Forchheim, Germany) with retrospective ECG-gated data acquisition. Scanning was performed with a 4 x 2.5-mm collimation. In each patient data acquisition was performed twice using tube settings of 120 kVp with 133 mAs (protocol 1) and of 80 kVp with 300 mAs (protocol 2). Together with the 80-kVp protocol additional online ECG-related tube current modulation (ECG pulsing) was used. Three-millimeter overlapping slices (increment 1.5 mm) were calculated for each data set. Semi-automated calcium quantification was performed calculating absolute Ca-hydroxylapatite mass. In addition to patient examinations, the radiation exposure for both protocols was evaluated using computed tomography dose index (CTDI) phantom measurements. Protocol 2 showed a significantly lower patient radiation exposure than protocol 1 (0.72 vs 2.04 mSv; p<0.0001). The CTDI phantom measurements revealed a 65% reduction of radiation dose. Calcium scoring results of both protocols showed a high correlation ( r=0.99; p<0.0001) for absolute Ca-Hydroxylapatite mass measurements. Using 80-kVp protocols patient radiation exposure can be significantly reduced in MSCT coronary artery calcium screening without affecting the detection and quantification of coronary artery calcification; therefore, this technique should be used with retrospective ECG-gated cardiac CT examinations in patients with regular sinus rhythm.

Calcinosis↗

Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT.

Multi-detector-row CT angiography (CTA) is a new technology that allows for non-invasive investigation of coronary atherosclerosis in patients. The relation between the morphology of atherosclerotic plaques assessed by CTA and histopathology is unknown. We investigated 11 human cadaver heart specimens. A mixture of methylcellulose and CT contrast media was injected into the coronary arteries to achieve in-vivo-like contrast enhancement within the coronary artery lumen. The morphologic pattern of atherosclerotic lesions found on CTA images and the tissue attenuation of non-calcified plaques were determined. After CTA imaging, atherosclerotic lesions in the coronary arteries were macroscopically identified and characterized histopathologically according to American Heart Association criteria. A total of 50 and 40 lesions were found macroscopically and by CTA, respectively. Thirty-three lesions could have been compared directly. The sensitivity of CTA compared with macroscopic detection of atheromas, fibroatheromas, fibrocalcified, and calcified lesions was 73, 70, 86, and 100%, respectively. The mean CT attenuation of predominantly lipid-rich and fibrous-rich plaques was significantly different (47+/-9 and 104+/-28 HU, respectively; p<0.01). Atherosclerotic coronary plaques detected by CTA may represent different stages of coronary atherosclerosis. The tissue attenuation of non-calcified plaques may allow for assessment of their predominant component.

Adult↗

Renal MR angiography: current debates and developments in imaging of renal artery stenosis.

Because of its safety and robustness with reproducible image quality, three-dimensional gadolinium-enhanced magnetic resonance angiography (3D-Gd-MRA) has been widely established as a diagnostic tool for screening and grading of renal artery stenosis. Accuracy and superiority over other noninvasive imaging procedures was again demonstrated in two recent meta-analyses. However, ambiguous results on the accuracy of this technique have been reported recently, again questioning the sole role of this modality for diagnostic assessment of the renal arteries. The main deficiencies of the technique are limited spatial resolution, high interobserver variability, limited anatomic coverage, as well as inability to assess the stenosis site after stent placement. In addition, a high level of competition has been introduced by techniques such as 16 detector multislice computed tomography, which generates superb image quality, with broad anatomic coverage and high spatial resolution, with minimal technical complexity. Lastly, aggressive search for renal artery stenosis by angiographic techniques in patients with hypertension is of debate, since only a limited percentage of these patients benefit from interventions. In this article, a comprehensive approach to high-resolution 3D-Gd-MRA, using parallel imaging in combination with cardiac-gated, phase-contrast flow measurements, is reviewed. This review is based on various studies and articles that address many of the problems of 3D-Gd-MRA. By making use of maximum spatial resolution and additional functional data, MRI permits accurate detection and grading of renal artery stenosis in most cases, with acceptable interobserver variability.

Contrast Media↗

Optimal contrast application for cardiac 4-detector-row computed tomography.

RATIONALE AND OBJECTIVES: This study was designed to determine the optimal contrast protocol for 4-detector-row computed tomography angiography of the heart. METHODS: Sixty patients were randomly assigned to 1 of 4 groups with 300 and 400 mg/mL iodine concentrations and 2.5 and 3.5 mL/s flow rates. Contrast density was measured in the left ventricular cavity and coronary arteries. RESULTS: Low iodine concentration injected at slow flow rate (0.75 g iodine/s) resulted in acceptable contrast enhancement in only 53.8% of the patients. There was no significant difference between low contrast concentration injected at high flow rate and high contrast concentration injected at slow flow rate ( approximately 1 g iodine/s). High contrast concentration administered with high flow rates (1.4 g iodine/s) may result in an enhancement above 350 Hounsfield units (HU) and interfere with coronary calcifications. CONCLUSIONS: The injection of approximately 1 g iodine/s resulted in an optimal (250-300 HU) contrast enhancement for cardiac 4-detector-row computed tomography.

Adult↗

Fetal magnetic resonance imaging: indications, technique, anatomical considerations and a review of fetal abnormalities.

Fetal MR imaging often poses a diagnostic challenge for the radiologist. Both fetal anatomy and pathology differ decidedly from pediatric and adult MR imaging. While ultrasound remains the method of choice for screening examinations of the fetus, MR imaging is playing an increasingly important role in the detection and classification of malformations not diagnosable by ultrasonography alone. Recently, advances in fast single-shot MR sequences have allowed high-resolution, high-quality imaging of the moving fetus. Preferable sequences to be applied are a true fast imaging steady precession (true-FISP) or a half-Fourier acquired single-shot turbo spin-echo (HASTE) sequence. Premedication is generally no longer required. In all fetal MR imaging, every aspect of fetal anatomy has to be scrutinized. Subsequently, any abnormalities need to be described and classified. A close collaboration with the referring obstetrician is of paramount importance.

Brain↗

Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation.

Our objective was to evaluate image quality and radiation exposure of retrospectively ECG-gated multislice helical CT (MSCT) investigations of the heart with ECG-controlled tube current modulation. One hundred patients underwent MSCT scanning (Somatom VolumeZoom, Siemens, Forchheim, Germany) for detection of coronary artery calcifications. A continuous helical data set of the heart was acquired in 50 patients (group 1) using the standard protocol with constant tube current, and in 50 patients (group 2) using an alternative protocol with reduced radiation exposure during the systolic phase. The standard deviations (SD) of predefined regions of interest (ROIs) were determined as a measure of image noise and were tested for significant differences. There was no significant difference between group 1 and group 2 with respect to image noise. Radiation exposure with and without tube current modulation was 1.0 and 1.9 mSv ( p<0.0001), respectively, for males and 1.4 and 2.5 mSv ( p<0.0001), respectively, for females; thus, there was a mean dose reduction of 48% for males and 45% for females, respectively. The ECG-controlled tube current modulation allows significant dose reduction when performing retrospectively ECG-gated MSCT of the heart.

Calcinosis↗

Pulmonary diffusing capacity: assessment with oxygen-enhanced lung MR imaging preliminary findings.

PURPOSE: To determine differences in the signal intensity (SI) time courses at oxygen-enhanced magnetic resonance (MR) lung imaging in healthy volunteers and patients with pulmonary diseases and to correlate these differences with pulmonary diffusing capacity. MATERIALS AND METHODS: Seventeen patients with pulmonary diseases and 11 healthy volunteers underwent oxygen-enhanced MR imaging while they breathed room air and 100% oxygen. A turbo spin-echo sequence with global or section-selective inversion pulses was used. For postprocessing, SI slope maps during the breathing of 100% oxygen were calculated. Mean SI slope and SI change values were compared with the diffusing capacity of the lung for carbon monoxide (DLCO). RESULTS: The SI slopes were significantly different for patients and volunteers (P < or = .05, Mann-Whitney U test). Linear correlations were detected between the DLCO and SI slopes for the section-selective inversion pulse (r(2) = 0.81) and the global inversion pulse (r(2) = 0.74). A lower correlation was associated with the SI change for the section-selective pulse (r(2) = 0.04; global pulse, r(2) = 0.81). Regional differences were seen in the SI slope and SI change maps. These differences correlated with findings on radiographs and computed tomographic scans. CONCLUSION: The SI slope during the breathing of 100% oxygen allows spatially resolved assessment of the pulmonary diffusion capacity.

Adult↗

Subsegmental pulmonary emboli: improved detection with thin-collimation multi-detector row spiral CT.

PURPOSE: To compare different reconstruction thicknesses of thin-collimation multi-detector row spiral computed tomographic (CT) data sets of the chest for the detection of subsegmental pulmonary emboli. MATERIALS AND METHODS: A multi-detector row spiral CT protocol for the diagnosis of pulmonary embolism was used that consisted of scanning the entire chest with 1-mm collimation within one breath hold. In 17 patients with central pulmonary embolism, the raw data were used to perform reconstructions with 1-mm, 2-mm, and 3-mm section thicknesses. For each set of images, each subsegmental artery was independently graded by three radiologists as open, containing emboli, or indeterminate. RESULTS: For the rate of detection of emboli in subsegmental pulmonary arteries, use of the 1-mm section width yielded an average increase of 40% when compared with the use of 3-mm-thick sections (P <.001) and of 14% when compared with the use of 2-mm-thick sections (P =.001). With the use of 1-mm sections versus 3-mm sections, the number of indeterminate cases decreased by 70% (P =.001). Interrater agreement was substantially better with the use of 1-mm and 2-mm sections than with the use of 3-mm sections. CONCLUSION: For the diagnosis of subsegmental pulmonary emboli at multi-detector row CT, the use of 1-mm section widths results in substantially higher detection rates and greater agreement between different readers than the use of thicker sections.

Adult↗

Coronary artery calcium: absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies.

PURPOSE: (a) To determine the accuracy of multi-detector row computed tomography (CT) in the measurement of the calcium concentration in a cardiac CT calibration phantom and (b) to assess the correlation of a traditional 3-mm section width CT coronary screening protocol and a 1.25-mm section width CT angiography imaging protocol in the quantification of the absolute mass of coronary calcium in patients who underwent both coronary screening and CT angiography with a multi-detector row CT scanner. MATERIALS AND METHODS: A heart phantom containing calcified cylinders was scanned to determine calibration factors and absolute calcium mass. In 50 patients, the variability (value 1 - value 2/mean value 1 - value 2), limit of agreement (+/-2SD value 1 - value 2), and systematic error (mean value 1 - value 2) of the total amount of coronary calcium calculated at traditional 3-mm section width CT and at 1.25-mm section width CT angiography were determined. RESULTS: The correlation coefficient between the 3-mm section width, nonenhanced protocol and the 1.25-mm section width CT angiography protocol was very high (r = 0.977) and the mean variability was low (19.7%) for the absolute mass. There was a systematic error of -6.7 mg and a limit of agreement between 45.0 mg and -58.5 mg. CONCLUSION: Use of the mass quantification algorithm in combination with a calibration phantom allows accurate quantification of coronary calcium. Measurements of calcium mass obtained at 1.25-mm section width CT angiography have the best agreement with those obtained at the traditional 3-mm section width imaging protocol.

Algorithms↗

MRI characteristics in focal hepatic disease before and after administration of MnDPDP: discriminant analysis as a diagnostic tool.

The aim of this study was to determine if different types of focal hepatic lesions can be differentiated by specific quantitative and qualitative imaging characteristics pre- and post-Mangafodipir trisodium (MnDPDP) administration using a computerized multivariable, discriminant analysis (DA). In a multicenter trial, 151 patients with focal liver disease were studied at 1.5 and 1.0 T using gradient-recalled echo T1 and fast spin-echo T2-weighted images pre and post MnDPDP (0.005 mmol/kg b.w.) i.v. administration. Analysis could be performed in 141 of 151 of the patients. The variables used in both single variable analysis and DA included contrast-to-noise ratios pre and post MnDPDP, presence of rim enhancement, margin, and heterogeneity of a lesion pre and post MnDPDP. The classification of diagnoses using DA was compared with a standard of reference (HCC in 23%, metastases in 25%, cyst in 13%, FNH in 10%, hemangioma in 11%, and other or no lesion in 18% of the patients; histology in 49%, long-term follow-up in 51% of the cases). In the differentiation of the various hepatic lesions, CNR together with the presence of heterogeneity or rim enhancement as variables for DA gave the highest sensitivity, specificity, and accuracy which ranged between 65 and 93, 44 and 83, and 65 and 86%, respectively. The DA models based on post-MnDPDP variables showed better classification results than the models based on pre-MnDPDP variables. An improvement of accuracy was observed when differentiating HCC from FNH lesion groups (48.9-67.4%; p < or = 0.05), and when differentiating HCC from metastasis lesion groups (68.3-84.1%; p < or = 0.01). In all regards there was no difference for T2-weighted images pre and post MnDPDP. By combining quantitative and qualitative variables, DA proved to be a useful tool in lesion discrimination. Due to considerable heterogeneity within some of the lesion type groups, the definite diagnostic impact of MnDPDP cannot be completely established yet, and further investigation is still necessary.

Adolescent↗

Multiplanar reformat display technique in abdominal multidetector row CT imaging.

The purpose of this study was to evaluate the image quality and diagnostic value of multiplanar reformat (MPR) of abdominal CT performed with multidetector row spiral technique (MDCT). Forty-five patients were referred for an abdominal MDCT angiography. No significant differences in image quality and in the number of lesions detected were found between axial and MPR images (t-test, P>.90 and chi-square, P>.95). Additional diagnostic value to axial images could be obtained with MPR display.

Adult↗

Likelihood of prostate cancer based on prostate-specific antigen density by MRI: retrospective analysis.

OBJECTIVE: As a screening test for prostate cancer (PCA), prostate-specific antigen (PSA) may induce unnecessary prostate biopsy in patients with PSA 4.1-10.0 ng/ml. PCA detection may be delayed in patients with PSA < or =4.0 ng/ml. MRI-based PSA density of the prostate (PSAD) and of the prostatic transitional zone (PSAT) could improve differentiation of PCA and benign prostatic hyperplasia. MATERIAL AND METHODS: Total prostate and transitional zone volumes were planimetrically determined in axial, T2-weighted fast spin echo MR images of the prostate. Serum PSA concentration was measured with an automated standardized microparticle enzyme immune assay. PSAD and PSAT were calculated in 17 patients with clinically significant PCA and 42 patients with benign prostatic hypertrophy (BPH) (66 +/- 6 versus 64 +/- 8 years, p = 0.2410, t test) who had PSA levels < or =10.0 ng/ml. RESULTS: For differentiation of BPH and PCA, PSA alone above the optimal cutoff level of 4.2 ng/ml showed an odds ratio for PCA of 6.7 (95% confidence interval [CI], 1.9-23.2). PSAD showed an odds ratio for PCA of 71.3 (95% CI, 11.8-430.9) above the optimal cutoff level of 0.07 ng/ml/cc. PSAT demonstrated an odds ratio for PCA of 320.0 (95% CI, 27.1-3781.4) above the optimal cutoff level of 0.15 ng/ml/cc. CONCLUSIONS: In patients with PSA < or =10.0 ng/ml, MRI-based PSAD and PSAT appear to improve differentiation of prostate cancer and BPH and are feasible to reduce the frequency of unnecessary prostate biopsy.

Aged↗