High-resolution whole-body magnetic resonance image tumor staging with the use of parallel imaging versus dual-modality positron emission tomography-computed tomography: experience on a 32-channel system.

OBJECTIVE: The objective of this study was to compare the accuracy in staging of various malignant tumors with whole-body magnetic resonance imaging (WB-MRI) using parallel imaging (PAT) and positron emission tomography-computed tomography (PET-CT). MATERIALS AND METHODS: In a prospective study, 41 patients withoncologic diseases underwent [F]-fluoro-2-deoxy-D-glucose PET-CT for tumor staging and WB-MRI on a 32-channel-scanner with the use of PAT. Coronal T1w and STIR sequences at 5 body levels, axial HASTE imaging of the lung, and contrast-enhanced T1w sequences of the liver, brain, and abdomen were performed. TNM stage was assessed for both modalities in a separate consensus reading using histologic results and radiologic follow up within 6 months as the standard of reference. RESULTS: Three primary and 4 recurrent tumors were detected; one recurrent tumor was missed with WB-MRI. Sixty benign and 60 malignant lymph nodes were detected with a sensitivity of 98% and specificity of 83% for PET-CT and 80%/75% for WB-MRI, respectively. One hundred ninety-one malignant and 77 benign distant lesions were detected with a sensitivity/specificity of 82% for PET-CT and 96%/82% for WB-MRI. Accuracy for correct TNM staging was 96% for PET-CT and 91% for WB-MRI. CONCLUSION: WB-MRI and PET-CT are reliable imaging modalities for tumor staging. WB-MRI is highly sensitive in detecting distant metastases; PET-CT is superior in lymph node staging. PAT makes high-resolution WB-MRI feasible within less than 1 hour.

Adult↗

Cardiovascular screening with parallel imaging techniques and a whole-body MR imager.

The purpose of this study was to integrate parallel acquisition techniques into a comprehensive whole-body cardiovascular screening protocol to image all relevant organ systems without compromising spatial or temporal resolution. The study was approved by the institutional review board, and oral and written informed consent was obtained from each subject. Fifty subjects underwent whole-body magnetic resonance imaging that included imaging of heart, blood vessels, brain, lungs, and abdominal organs with a standard eight-channel imager. Image quality and pathologic findings were evaluated by two readers. The same protocol was then implemented with a new 32-channel whole-body imager. Depiction of 1476 (73.2%) of 2016 vessel segments was rated as good to excellent, and that of 1744 (86.5%), as without venous overlay. Interobserver agreement was good in evaluation of image quality and excellent in evaluation of pathologic findings. Acquisition time was reduced significantly (P < .05) with use of the whole-body imager and parallel acquisition techniques, which provided high-quality fast cardiovascular imaging.

Adult↗

Phase-sensitive inversion-recovery MR imaging in the detection of myocardial infarction.

PURPOSE: To prospectively determine if phase-sensitive inversion-recovery (IR) magnetic resonance (MR) imaging eliminates the need to find the precise inversion time (TI) to null the signal of normal myocardium to achieve high contrast between infarcted and normal myocardium. MATERIALS AND METHODS: Informed consent was obtained from each patient for this prospective MR imaging research study, which was approved by the institutional review board. Twenty patients (16 men; four women; mean age, 56 years +/- 12.3) who experienced Q-wave myocardial infarction 2 weeks earlier were examined with a 1.5-T MR system 10 minutes after administration of 0.1 mmol per kilogram of body weight gadobenate dimeglumine. To determine the optimal TI, a TI scout sequence was used. A segmented two-dimensional IR turbo fast low-angle shot (FLASH) sequence and a segmented two-dimensional IR true fast imaging with steady-state precession (FISP) sequence that produces both phase-sensitive and magnitude-reconstructed images were used at TI values of 200-600 msec (TI values were varied in 100-msec steps) and at optimal TI (mean value, 330 msec). Contrast-to-noise ratios (CNRs) of normal and infarcted myocardium and the area of infarcted myocardium were determined. Magnitude-reconstructed IR turbo FLASH images were compared with magnitude-reconstructed and phase-sensitive IR true FISP images. Two-tailed unpaired sample Student t test was used to compare CNRs, and two-tailed paired-sample Student t test was used to compare area of infarction. RESULTS: Mean CNR of images acquired with IR turbo FLASH and IR true FISP (phase-sensitive and magnitude-reconstructed images) at optimal TI (mean value, 330 msec) were 6.6, 6.2, and 6.1, respectively. For a TI of 200 msec, CNR values were -4.3, -4.0, and 7.2, respectively; for TI of 600 msec, CNR values were 3.1, 3.3, and 4.3, respectively. Area of infarcted myocardium was underestimated on magnitude-reconstruction images (P = .002-.03) for short TI values (ie, 200 msec) for both sequences and for a TI of 300 msec for IR true FISP but not on phase-sensitive reconstructed IR true FISP images when compared with IR turbo FLASH images obtained at optimal TI. CONCLUSION: Phase-sensitive image reconstruction results in reduced need for precise choice of TI and more consistent image quality.

Adult↗

Optimization of MDCT of the wrist to achieve diagnostic image quality with minimum radiation exposure.

OBJECTIVE: This study tests various acquisition and reconstruction protocols for MDCT of the wrist to determine the optimal protocol for obtaining diagnostic image quality with minimal radiation exposure. MATERIALS AND METHODS: Thirty anatomic specimens were examined with an MDCT collimation of 4.0 x 1.0 mm and 2.0 x 0.5 mm (80, 120, and 140 kV; 80, 100, 130, 160, and 200 mA; rotation time, 0.5 0.75, 1.0 sec; pitch, 1.0, 1.3, 1.5, and 2.0). Coronal images were reconstructed using a slice thickness of 0.5, 1.0, and 2.0 mm with 60% overlap. Three observers evaluated all images independently for gross and fine anatomic detail. Diagnostic confidence was tested using Shrout-Fleiss intraclass correlation coefficients. Interobserver agreement was assessed by Kappa statistics and the Kruskal-Wallis test. RESULTS: Fine anatomic detail was best presented in 0.5-mm or 1.00-mm reconstructions based on a 2.0 x 0.5 mm acquisition. A rotation time of > or = 0.75 sec resulted in fewer artifacts; a significant dose reduction was achieved with 80 kV and 100 mA at the expense of somewhat increased noise, but without significant loss of anatomic detail in bone presentation. Artifacts were tolerable with a pitch of 1.5 or less. CONCLUSION: MDCT at the described optimal settings allows significant dosage reduction without sacrificing image quality. An acquisition and reconstruction thickness of 0.5 mm results in the best depiction of anatomic detail. A reconstruction thickness of 1.0 mm with a reconstruction interval of 0.5 mm represents a good trade-off between noise and resolution when using low-dose protocols.

Aged↗

A comparative evaluation of a RARE-based single-shot pulse sequence for diffusion-weighted MRI of musculoskeletal soft-tissue tumors.

The purpose of this study was to evaluate the feasibility of a centric-reordered modified rapid acquisition with relaxation enhancement (mRARE) sequence for single-shot diffusion-weighted magnetic resonance imaging (DWI) of soft-tissue tumors in the musculoskeletal system. In the evaluation of this sequence, DWI was performed in a liquid phantom, in excised human tumor samples embedded in bovine muscle, and in nine patients suffering from different types of soft-tissue tumors. The measurements were compared to DWI using a spin-echo sequence and a single-shot echo planar imaging (EPI) sequence. The phantom measurements in water and dimethyl sulfoxide showed a difference of less than 5% when comparing the apparent diffusion coefficients (ADCs) determined by the mRARE sequence and the two other techniques. Comparing mRARE and EPI, the differences in the ADCs were about 10% in the excised tumor tissue and, typically, about 15% in vivo. ADCs between 0.8 x 10(-3) mm2/s and 1.4 x 10(-3) mm2/s, depending on the tumor type, were found in solid tumor tissue; in cystic tumor areas, ADCs greater than 2.0 x 10(-3) mm2/s were determined with the mRARE and the EPI sequences. Diffusion-weighted images of the mRARE sequence were less distorted than those acquired with the single-shot EPI sequence, and provided more anatomic information, since the muscle and fat signals were considerably higher.

Aged↗

Enhancement of focal liver lesions at gadoxetic acid-enhanced MR imaging: correlation with histopathologic findings and spiral CT--initial observations.

PURPOSE: To detect hepatocyte-selective enhancement of focal lesions with gadoxetic acid at magnetic resonance (MR) imaging and to correlate enhancement in hepatocyte-selective phases with histopathologic findings and in arterial and portal venous phases with biphasic computed tomographic (CT) findings. MATERIALS AND METHODS: Study was supported by local ethics committee; all patients gave written informed consent. In 19 men and 14 women recruited in three clinical studies, histopathologic correlation and CT scans of 41 focal lesions (13 primary malignant lesions, 21 metastases, three adenomas, three cases of focal nodular hyperplasia [FNH], and one cystadenoma) and ultrasonographic confirmation of five cysts were available. MR was performed before and during arterial and portal venous phases and in hepatocyte-selective phases 10 and 20 minutes after injection of gadoxetic acid. Enhancement was evaluated in consensus by two observers. Enhancement pattern and morphologic features during arterial and portal venous phases were correlated between gadoxetic acid-enhanced MR and CT images by means of adjusted chi(2) test. RESULTS: Hepatocyte-selective uptake was observed 10 and 20 minutes after injection in FNH (three of three), adenoma (two of three), cystadenoma (one of one), and highly differentiated hepatocellular carcinoma (HCC [grade G1], two of four). Uptake was not detected in metastases (21 of 21), cholangiocarcinoma (three of three), combined hepatocellular cholangiocarcinoma (one of one), undifferentiated carcinoma (one of one), moderately or poorly differentiated HCC (grade G2-G3) (four of four), HCC (grade G1, two of four), adenoma with atypia (one of three), or cysts (five of five). During arterial and portal venous phases, there was high overall agreement rate of 0.963 between gadoxetic acid-enhanced MR and CT (simultaneous 95% confidence interval: 0.945, 0.981). CONCLUSION: Liver-specific enhancement of focal lesions is hepatocyte selective and correlates with various histopathologic diagnoses regarding presence of certain hepatocytic functions. Arterial and portal venous MR images obtained with gadoxetic acid are comparable to those of CT.

Adenoma↗

Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience.

The aim of this technical investigation was the detailed description of a prototype flat panel detector computed tomography system (FPCT) and its initial evaluation in an ex vivo setting. The prototype FPCT scanner consists of a conventional radiographic flat panel detector, mounted on a multi-slice CT scanner gantry. Explanted human ex vivo heart and foot specimens were examined. Images were reformatted with various reconstruction algorithms and were evaluated for high-resolution anatomic information. For comparison purposes, the ex vivo specimens were also scanned with a conventional 16-detector-row CT scanner (Sensation 16, Siemens Medical Solutions, Forchheim, Germany). With the FPCT prototype used, a 1,024x768 resolution matrix can be obtained, resulting in an isotropic voxel size of 0.25x0.25x0.25 mm at the iso-center. Due to the high spatial resolution, very small structures such as trabecular bone or third-degree, distal branches of coronary arteries could be visualized. This first evaluation showed that flat panel detector systems can be used in a cone-beam computed tomography scanner and that very high spatial resolutions can be achieved. However, there are limitations for in vivo use due to constraints in low contrast resolution and slow scan speed.

Foot Bones↗

CT measurement of coronary calcium mass: impact on global cardiac risk assessment.

Coronary calcium mass percentiles can be derived from electron beam CT as well as from multidetector-row CT of all manufacturers. Coronary calcium mass may serve as a more individualized substitute for age for cardiac risk stratification. The aim was to investigate the potential impact of CT coronary calcium mass quantification on cardiac risk stratification using an adjusted Framingham score. Standardized coronary calcium mass was determined by multidetector-row CT in a total of 1,473 patients (1,038 male, 435 female). The impact on risk stratification of replacing the traditional Framingham age point score by a point score based on calcium mass relative to age was tested. Any coronary calcium found in males in the age group of 20-34 years and females in the age group of 20-59 years results in an increase of the Framingham score by 9 and 4-7 points, respectively. Only in males 65 years of age and older, none or minimal amounts of coronary calcium decrease the Framingham score by three points. The coronary calcium mass and age-related scoring system may have impact on the reassignment of patients with an intermediate Framingham risk to a lower or higher risk group.

Adult↗

Relation of coronary calcium scores by electron beam tomography to obstructive disease in 2,115 symptomatic patients.

This angiographically correlated study reports on, for the first time, age- and gender-based distribution of the volumetric calcium score in a large group of patients with suspected coronary artery disease. Volumetric calcium data predicted significant coronary artery disease (>/=50% lumen diameter stenosis) as well as the traditional Agatston score. Exclusion of any calcium was highly accurate in ruling out obstructive disease in symptomatic subjects >/=50 years of age.

Adult↗

Multi-detector row CT angiography of the brain at various kilovoltage settings.

PURPOSE: To investigate image quality and vascular delineation of multi-detector row computed tomographic (CT) angiography at various kilovoltage settings. MATERIALS AND METHODS: Thirty patients were investigated with a standardized CT protocol, with three groups of 10 consecutive patients examined at 80, 120, and 140 kV, respectively. Three blinded readers independently evaluated images and graded image quality parameters, diagnostic confidence, and vascular delineation of intracranial arteries and veins. Vascular CT attenuation values, CT dose indices, and dose length products were assessed quantitatively. For data analysis, a Kruskal-Wallis nonparametric rank F test was used to identify trends and variables that required modeling attention. A proportional odds multinomial regression model was then fit with generalized estimating equations to account for the correlated nature of the data. RESULTS: Image quality was rated higher with higher kilovoltage settings (P <.001). The severity of imaging artifacts was higher with lower kilovoltage settings (P <.001), while the subjectively rated vessel contrast was lower in the 80-kV group than in the 120-kV group and the 140-kV group (P <.05). Diagnostic confidence was higher in the 120-kV group and 140-kV group (P <.005). Vascular delineation was higher with higher kilovoltage settings for most arterial and venous structures. Differences were more significant for structures in close topographic proximity to bone and for subsegmental arteries and were less significant and, in parts, not significant for the main arterial branches and the large venous sinus. Attenuation values were higher with lower kilovoltage settings (P <.05). The mean dose length product could be reduced from 594 mGy. cm in the 140-kV group to 152 mGy.cm in the 80-kV group. CONCLUSION: This multireader study of image quality and vessel delineation with cranial multi-detector row CT angiography at various kilovoltage settings demonstrated a superiority of higher voltages with most pronounced effects for vessels adjacent to bone and subsegmental arteries.

Adolescent↗

Blurring of the vessels of the interhemispheric fissure in multislice CT angiography: a sign of meningeal carcinomatosis.

Meningeal carcinomatosis remains a challenging diagnosis to make, with both cerebrospinal fluid (CSF) analysis and radiological methods having a limited sensitivity. We aimed at describing a possible diagnostic sign of multislice CT angiography (MS-CTA) in the diagnosis of meningeal carcinomatosis. Upon retrospective analysis of MSCT angiographies of the brain, a conspicuous sign of the vessels of the interhemispheric fissure was noted in five patients. Cranial MSCT angiographies were performed with a standardized protocol (120 kV, 200 mA s, collimation of 4x1 mm, table feed per rotation 4 mm). We injected 120 ml of nonionic contrast medium as a bolus, and data acquisition was started after a fixed delay of 35 s. In order to elucidate the finding, correlation with clinical follow-up and/or CSF findings was performed for all patients. In five patients there was a blurring, an increased number, and a pathologic configuration of the vessels of the interhemispheric fissure. All five patients with this sign had clinical signs and symptoms of meningeal carcinomatosis. Three patients had positive CSF cytology, one further patient had follow-up spinal MRI 6 weeks later demonstrating meningeal carcinomatosis. One patient declined lumbar puncture. MS-CTA has the capacity to demonstrate a pathologic configuration of the vessels of the interhemispheric fissure in patients with meningeal carcinomatosis. This sign may serve as an indicator of meningeal carcinomatosis and should raise the suspicion of this disease entity.

Cerebral Angiography↗

High-resolution MR-imaging of the liver with T2-weighted sequences using integrated parallel imaging: comparison of prospective motion correction and respiratory triggering.

PURPOSE: To compare high-resolution T2-weighted images of the liver with and without integrated parallel acquisition techniques (iPAT) using either breath-hold sequences in combination with prospective acquisition motion correction (PACE) or respiratory triggering. MATERIALS AND METHODS: Ten volunteers and 10 patients underwent each four different high-resolution fast spin echo (FSE) T2-weighted sequences with 5 mm slice thickness and a full 320 matrix: a multi-breath-hold FSE sequence with and without iPAT and PACE and a respiratory-triggered FSE sequence with and without iPAT. Image quality was rated with a five-point scale by two independent readers. Signal intensity measurements were performed on a water phantom. RESULTS: The sequences with iPAT required a substantially shorter acquisition time without loss of image quality. Overall image quality was rated equal for all sequences by both readers. Image time for nine slices with iPAT was 13 seconds (19 seconds without iPAT) with multi-breath-hold and on average 4:00 minutes (7:02 minutes without iPAT) with respiratory triggering. Imaging with the PACE technique resulted in more correct positioning of the image stacks. CONCLUSION: T2-weighted fast imaging with iPAT is feasible and results in high-quality images within a short acquisition time. Overall image quality is not negatively affected by iPAT.

Adult↗

Advances in cardiac CT imaging: 64-slice scanner.

BACKGROUND: Clinical progress by the development of multi-slice CT (MSCT) technology beyond 16 slices can more likely be expected from further improved spatial and temporal resolution rather than from a mere increase in the volume coverage speed. We present an evaluation of a recently introduced 64-slice CT (64SCT) system, which makes use of a periodic motion of the focal spot in the longitudinal direction (z-flying focal spot) to double the number of simultaneously acquired slices. MATERIALS AND METHODS: A recently introduced 64SCT system (SOMATOM Sensation 64, Siemens Medical Solutions, Forchheim, Germany) is being described and tested in first clinical practice, applying the following parameters: z-flying focal spot technology, 64 x 0.6 mm slices; spatial resolution, 0.4 x 0.4 x 0.4 mm; gantry rotation time, 330 ms; temporal resolution, 83-165 ms. Various phantom studies and first clinically implemented protocols are being described, to evaluate the full spectrum of possible applications for this scanner type, with a focus on cardiac imaging. RESULTS: ECG-gated cardiac scanning with this 64-slice CT system benefits clearly from both the improved temporal resolution and improved spatial resolution. These benefits enable a more reliable assessment of mixed plaques, due to reduced partial-voluming and beam-hardening artefacts caused by calcifications, and holds great promise for the reliable assessment of in-stent stenoses, as stent lumen visibility is clearly improved as compared to earlier MSCT systems. With the increased volume coverage and acquisition speed of the 64SCT system, a comprehensive emergency protocol of the thorax becomes feasible within an acceptable breath-hold time, performing an ECG-gated CT angiography of the complete thoracic vasculature. This protocol enables a detailed assessment of the thoracic aorta, the pulmonary arteries and the coronary arteries in one single examination. CONCLUSIONS: 64SCT Cardiac imaging provides an increased spatial resolution with an isotropic voxel size of 0.4 mm and an improved temporal resolution of 83-165 ms. These benefits hold great promise especially for fast-moving organs requiring detailed imaging, such as the heart and coronary arteries.

Calcinosis↗

Multidetector-row computed tomography and magnetic resonance imaging of atherosclerotic lesions in human ex vivo coronary arteries.

In the present study, we tested the ability of multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI) to identify and retrospectively characterize atherosclerotic lesions in human ex vivo coronary arteries. Thirteen ex vivo hearts were studied with MDCT and MRI. MDCT-images were obtained with an isotropic voxel size of 0.6mm(3). MR images were obtained with an in-plane resolution of 195 microm and 3mm slice thickness. All images were matched with histopathology sections. For both modalities, the sensitivity for the detection of any atherosclerotic lesion was evaluated, and a retrospective analysis of plaque morphology according to criteria defined by the American Heart Association (AHA) was performed. At histopathology, 28 atherosclerotic lesions were found. 21 and 23 of these lesions were identified by MDCT and MRI, respectively. Both modalities detected a small number of false-positive lesions. After retrospective matching with histopathology, MDCT as well as MRI were able to differentiate typical morpholocigal features for fatty, fibrous or calcified plaque components. Using the information presented in this study, in vivo coronary artery wall imaging using MDCT as well as MRI could be facilitated and supported for future investigations on this subject.

Adult↗

Model-free functional MRI analysis based on unsupervised clustering.

Conventional model-based or statistical analysis methods for functional MRI (fMRI) are easy to implement, and are effective in analyzing data with simple paradigms. However, they are not applicable in situations in which patterns of neural response are complicated and when fMRI response is unknown. In this paper the "neural gas" network is adapted and rigourosly studied for analyzing fMRI data. The algorithm supports spatial connectivity aiding in the identification of activation sites in functional brain imaging. A comparison of this new method with Kohonen's self-organizing map and with a fuzzy clustering scheme based on deterministic annealing is done in a systematic fMRI study showing comparative quantitative evaluations. The most important findings in this paper are: (1) both "neural gas" and the fuzzy clustering technique outperform Kohonen's map in terms of identifying signal components with high correlation to the fMRI stimulus, (2) the "neural gas" outperforms the two other methods with respect to the quantization error, and (3) Kohonen's map outperforms the two other methods in terms of computational expense. The applicability of the new algorithm is demonstrated on experimental data.

Adult↗

Morphological and functional magnetic resonance imaging after heterotopic heart transplantation.

In patients with severe congestive heart failure, a marked elevation in pulmonary vascular resistance limits the success of orthotopic cardiac transplantation, providing the rationale for heterotopic transplantation. In the case reported, cardiac anatomy and function of two hearts in the same chest were imaged using magnetic resonance imaging (MRI). MRI offers a high-resolution, three-dimensional, noninvasive technique to visualize the complex anatomy after heterotopic heart transplantation, providing information of morphologic and functional parameters at the same time. The challenge of sufficient electrocardiogram triggering, hindered by two hearts with electrophysiological activity in the same chest, can be overcome using new real-time techniques.

Aged↗

Optimization of ex vivo CT- and MR- imaging of atherosclerotic vessel wall changes.

OBJECTIVE: To optimize a methodology for ex vivo imaging of atherosclerotic vessel wall changes using multidetector-row computed tomography (MDCT) and multi-contrast magnetic resonance imaging (MRI). METHODS: In phantom studies and studies on intact ex vivo porcine and human hearts, various filling mixtures of MDCT and MRI contrast agents have been evaluated, to enable filling and distension of the coronary arteries for optimal visualization of atherosclerotic vessel wall changes with both techniques. Various proportions of methyl cellulose, iodine-containing CT contrast agent and paramagnetic MR contrast agent containing iron-oxide particles have been tested. Imaging parameters have been optimized for high resolution plaque imaging using a four detector-row CT scanner and a 1.5 T MR system. RESULTS: Phantom studies and studies on ex vivo porcine and human hearts demonstrated optimal proportion of methyl cellulose and CT contrast agent to be 98% vs. 2%, and 75% vs. 25% of methyl cellulose vs. MR contrast agent, respectively. These proportions provided optimal opacification of the vessel lumen in the MDCT images with 250 Hounsfield Units, and good signal suppression within the vessel lumen in the MR images, resembling in vivo imaging techniques. After retrospective matching with histopathology, atherosclerotic lesions of the human ex vivo specimens could be identified on MRI and MDCT images. CONCLUSION: Using an optimized mixture of methyl cellulose, MDCT and MRI contrast agents, visualization of atherosclerotic vessel wall changes is feasible, and applicable to various ex vivo models.

Aged↗