Three dimensional MEMS microfluidic perfusion system for thick brain slice cultures.

In vitro tissue culture models are often benchmarked by their ability to replicate in vivo function. One of the limitations of in vitro systems is the difficulty in preserving an orchestrated cell population, especially for generating three-dimensional tissue equivalents. For example, tissue-engineering applications involve large high-density constructs, requiring a perfusing system that is able to apply adequate oxygen and nutrients to the interior region of the tissue. This is particularly true with respect to thick tissue sections harvested for in vitro culture. We have fabricated a microneedle-based perfusion device for high-cell-density in vitro tissue culture from SU-8 photosensitive epoxy and suitable post-processing. The device was tested for its ability to improve viability in slices of harvested brain tissue. This model was chosen due to its acute sensitivity to disruptions in its nutrient supply. Improved viability was visible in the short term as assessed via live-dead discriminating fluorescent staining and confocal microscopy. This perfusion system opens up many possibilities for both neurobiological as well as other culture systems.

Animals↗

A multielectrode microcompartment culture platform for studying signal transduction in the nervous system.

This paper describes the design, fabrication, and characterization of a microfabricated compartmented culture system (micro-CCS) useful for electrophysiological signaling studies in cultured neurons. The focus of the paper is the process of interfacing the micro-CCS with cultured neurons and to demonstrate the applicability of the system for biochemical-mediated electrophysiological studies. Moreover, we show that we can record action potentials from cultured neurons through the extracellular compartmented application of elevated levels of K(+) ions. Finally, we show that we can isolate the electrophysiological effects of the sodium channel blocker tetrodotoxin in one of the compartments of a two compartment culture while recording electrophysiological data from both compartments.

Animals↗

Microfluidic devices for the high-throughput chemical analysis of cells.

A microfluidic device is reported that integrated cell handling, rapid cell lysis, and electrophoretic separation and detection of fluorescent cytosolic dyes. The device function was demonstrated using Jurkat cells that were loaded with the fluorogenic dyes - carboxyfluorescein diacetate, Oregon green carboxylic acid diacetate, or Calcein AM. The loaded cells were hydrodynamically transported from the cell-containing reservoir to a region on the microfluidic device where they were focused and then rapidly lysed using an electric field. Complete lysis was accomplished in <33 ms. The hydrolyzed, fluorescent dyes in the cell lysate were automatically injected into a separation channel on the device and detected 3 mm downstream of the injection point. The total separation time was approximately 2.2 s with absolute migration time reproducibilities of <1% and efficiencies ranging from 2300 to 4000 theoretical plates. Results from 139 cells are reported. A small fraction of these cells, approximately 9%, were found to enzymatically hydrolyze the loaded dyes in a manner significantly different from the majority of the cells. Cell analysis rates of 7-12 cells/min were demonstrated and are >100 times faster than those reported using standard bench-scale capillary electrophoresis.

Algorithms↗