Megan Cornwell

Publications and source records attributed to Megan Cornwell.

2 recordsLinked to original sources

Precise microinjection into skin using hollow microneedles.

Hollow needles of micron dimensions have previously been fabricated and envisioned for use with transdermal patches or infusion pumps to achieve painless delivery of drugs to the skin for local and systemic effects without the need for hypodermic needles. However, little work has been carried out to identify methods to effectively use hollow microneedles for drug delivery. To address this need, we inserted hollow, glass microneedles into hairless rat skin in vivo and human cadaver skin in vitro and then imaged infusion of dye molecules, insulin, polymer microparticles, and cells into the skin by brightfield and fluorescence microscopy. The depth of needle penetration into skin was controlled by inserting needles with a rotary drilling device, which enabled localized injection within the epidermis or dermis with +/-60 microm resolution. Although small quantities of fluid could be injected after needle insertion into skin, partial retraction of the needle by withdrawing back 100-300 microm or vibrating the microneedle array dramatically increased infusion flow rate. We conclude that hollow microneedles can be used for precise microinjection into skin, especially when a single needle is inserted by rotary drilling and then retracted part way before infusion or a microneedle array is inserted by mechanical vibration.

Cell Transplantation↗

Minimally invasive extraction of dermal interstitial fluid for glucose monitoring using microneedles.

BACKGROUND: Compliance with glucose monitoring by patients with diabetes is poor because of the pain and inconvenience of conventional blood collection using lancets. To improve compliance, and thereby reduce morbidity and mortality associated with poor glucose control, this study sought to develop and test minimally invasive microneedles to extract dermal interstitial fluid (ISF) for glucose monitoring. METHODS: We used a thermal puller to fabricate individual or multi-needle arrays of glass microneedles with tip radii of 15-40 microm to penetrate 700-1,500 microm deep into the skin of anesthetized hairless rats or conscious, normal, adult, human subjects. After applying a vacuum of 200-500 mm Hg for 2-10 min, we extracted ISF and measured glucose concentration. These measurements were compared with glucose levels in blood collected from the tail vein of rats or finger stick on humans. RESULTS: Using this procedure, 1-10 microL of ISF was extracted out of holes punctured in the skin using microneedles. Human subjects generally reported the procedure as painless. ISF glucose concentration correlated well with blood levels based on 140 measurements on 15 rats and six measurements on six human subjects, where 95% of rat data and 100% of human data fell within the clinically acceptable A + B region in Clarke Error Grid analysis. A linear calibration factor was needed to correlate ISF and blood glucose concentrations using our standard procedure. Modifying the procedure to prevent ISF evaporation during extraction provided a one-to-one correlation that eliminated the need for calibration. ISF glucose measurements tracked rapidly changing blood glucose levels following insulin injection with a time lag of less than 20 min. CONCLUSIONS: These results suggest that microneedle devices can be used to extract ISF for painless glucose monitoring.

Animals↗