PubMed Health⌕ Search

Biomedical subjects

Meghan E Halse

Publications and source records attributed to Meghan E Halse.

2 recordsLinked to original sources

Imaged deconvolution: a method for extracting high-resolution NMR spectra from inhomogeneous fields.

We present a novel method for obtaining high resolution NMR spectra in the presence of grossly inhomogeneous magnetic fields, such as those encountered in one-sided access NMR. Our method combines the well-known principle of reference deconvolution with NMR imaging in order to resolve spectral features with frequency resolution orders of magnitude smaller than the prevailing line-broadening due to field inhomogeneity. We demonstrate that, in cases of inhomogeneous field line-broadening more than an order of magnitude larger than the spectral features to be resolved, rather than performing reference deconvolution on the sample as a whole, it is more favourable in terms of SNR to divide the target region of a sample into smaller sub-regions, by means of chemical shift imaging, and then to perform reference deconvolution on the individual sub-region spectra, finally summing the results In this way, significant resolution enhancements can be obtained in the presence of severe magnetic field inhomogeneity without an unacceptable loss in SNR.

Algorithms↗

A practical and flexible implementation of 3D MRI in the Earth's magnetic field.

The Earth's magnetic field, though weak, is appealing for NMR applications because it is highly homogeneous, globally available and free. However, the practicality of Earth's field NMR (EFNMR) has long been limited by the need to perform experiments in outdoor locations where the local field homogeneity is not disrupted by ferrous or magnetic objects and where ultra-low frequency (ULF) noise sources are at a minimum. Herein we present a flexible and practical implementation of MRI in the Earth's magnetic field that demonstrates that EFNMR is not as difficult as it was previously thought to be. In this implementation, pre-polarization and ULF noise shielding, achieved using a crude electromagnet, are used to significantly improve signal-to-noise ratio (SNR) even in relatively noisy environments. A three axis gradient coil set, in addition to providing imaging gradients, is used to provide first-order shims such that sub-hertz linewidths can routinely be achieved, even in locations of significant local field inhomogeneity such as indoor scientific laboratories. Temporal fluctuations in the magnitude of the Earth's magnetic field are measured and a regime found within which these variations in Larmor frequency produce no observable artefacts in reconstructed images.

Journal Article↗