PubMed Health⌕ Search

Biomedical subjects

Mehmet Toner

Publications and source records attributed to Mehmet Toner.

At least 19 recordsLinked to original sources

Oxygen uptake rates and liver-specific functions of hepatocyte and 3T3 fibroblast co-cultures.

Bioartificial liver (BAL) devices have been developed to treat patients undergoing acute liver failure. One of the most important parameters to consider in designing these devices is the oxygen consumption rate of the seeded hepatocytes which are known to have oxygen consumption rates 10 times higher than most other cell types. Hepatocytes in various culture configurations have been tested in BAL devices including those formats that involve co-culture of hepatocytes with other cell types. In this study, we investigated, for the first time, oxygen uptake rates (OUR)s of hepatocytes co-cultured with 3T3-J2 fibroblasts at various hepatocyte to fibroblast seeding ratios. OURs were determined by measuring the rate of oxygen disappearance using a ruthenium-coated optical probe after closing and sealing the culture dish. Albumin and urea production rates were measured to assess hepatocyte function. Lower hepatocyte density co-cultures demonstrated significantly higher OURs (2 to 3.5-fold) and liver- specific functions (1.6-fold for albumin and 4.5-fold for urea production) on a per cell basis than those seeded at higher densities. Increases in OUR correlated well with increased liver-specific functions. OURs (V(m)) were modeled by fitting Michaelis-Menten kinetics and the model predictions closely correlated with the experimental data. This study provides useful information for predicting BAL design parameters that will avoid oxygen limitations, as well as maximize metabolic functions.

3T3 Cells↗

A bioartificial liver device secreting interleukin-1 receptor antagonist for the treatment of hepatic failure in rats.

BACKGROUND: Liver transplantation is the treatment of choice for many patients with fulminant hepatic failure (FHF). A major limitation of this treatment is the lack of available donors. An optimally functioning bio-artificial liver (BAL) device has the potential to provide critical hepatic support to patients with FHF. In this study, we examined the efficacy of combining interleukin-1 (IL-1) receptor blockade with the synthetic function of hepatocytes in a BAL device for the treatment of FHF. MATERIALS AND METHODS: We injected an adenoviral vector encoding human IL-1 receptor antagonist (AdIL-1Ra) into the liver of D-galactosamine (GalN) intoxicated rats via the portal vein. We also transfected primary rat hepatocytes and reversibly immortalized human hepatocytes (TTNT cells) with AdIL-1Ra, and incorporated these transfected hepatocytes into our flat-plate BAL device and evaluated their efficacy in our GalN-induced FHF rat model after 10 h of extracorporeal perfusion. RESULTS: Rats injected with AdIL-1Ra showed significant reductions in the plasma levels of hepatic enzymes. Primary rat hepatocytes transfected with AdIL-1Ra secreted IL-1Ra without losing their original synthetic function. Incorporating these cells into the BAL device and testing in a GalN-induced FHF rat model resulted in significant reductions in plasma IL-6 levels and significantly improved animal survival. Incorporating the AdIL-1Ra transfected TTNT cells in the BAL device and testing in the GalN-induced FHF rat model resulted in significantly reduced plasma IL-6 levels, and a trend toward improved survival was seen. CONCLUSION: Hepatocytes producing IL-1Ra are a promising cell source for BAL devices in the treatment of GalN-induced FHF.

Adenoviridae↗

A high-throughput microfluidic real-time gene expression living cell array.

The dynamics of gene expression are fundamental to the coordination of cellular responses. Measurement of temporal gene expression patterns is currently limited to destructive low-throughput techniques such as northern blotting, reverse transcription polymerase chain reaction (RT-PCR), and DNA microarrays. We report a scalable experimental platform that combines microfluidic addressability with quantitative live cell imaging of fluorescent protein transcriptional reporters to achieve real-time characterization of gene expression programs in living cells. Integrated microvalve arrays control row-seeding and column-stimulation of 256 nanoliter-scale bioreactors to create a high density matrix of stimulus-response experiments. We demonstrate the approach in the context of hepatic inflammation by acquiring approximately 5000 single-time-point measurements in each automated and unattended experiment. Experiments can be assembled in hours and perform the equivalent of months of conventional experiments. By enabling efficient investigation of dynamic gene expression programs, this technology has the potential to make significant impacts in basic science, drug development, and clinical medicine.

Cell Culture Techniques↗

Microfluidic isolation of leukocytes from whole blood for phenotype and gene expression analysis.

Technologies that enable the isolation of cell subtypes from small samples of complex populations will greatly facilitate the implementation of proteomics and genomics to human diseases. Transcriptome analysis of blood requires the depletion of contaminating erythrocytes. We report an automated microfluidic device to rapidly deplete erythrocytes from whole blood via deionized water lysis and to collect enriched leukocytes for phenotype and genomic analyses. Starting with blood from healthy subjects, we demonstrate the utility of this microfluidic cassette and lysis protocol to prepare unstimulated leukocytes, and leukocytes stimulated ex vivo with Staphylococcal enterotoxin B, which mimics some of the cellular effects seen in patients with severe bacterial infections. Microarrays are used to assess the global gene expression response to enterotoxin B. The results demonstrate that this system can isolate unactivated leukocytes from small blood samples without any significant loss, which permits more information to be obtained from subsequent analysis, and will be readily applicable to clinical settings.

Cell Separation↗

Liver-specific functional studies in a microfluidic array of primary mammalian hepatocytes.

Nearly half a billion dollars in resources are lost each time a drug candidate is withdrawn from the market by the Food and Drug Administration (FDA) for reasons of liver toxicity. The number of late-phase drug developmental failures due to liver toxicity could potentially be reduced through the use of hepatocyte-based systems capable of modeling the response of in vivo liver tissue to toxic insults. With this article, we report progress toward the goal of realizing an array of primary hepatocytes for use in high-throughput liver toxicity studies. Described herein is the development of a 64 (8 x 8) element array of microfluidic wells capable of supporting micropatterned primary rat hepatocytes in coculture with 3T3-J2 fibroblasts. Each of the wells within the array was continuously perfused with medium and oxygen in a nonaddressable format. The key features of the system design and fabrication are described, including the use of two microfluidic perfusion networks to provide the coculture with an independent and continuous supply of cell culture medium and oxygen. Also described are the fabrication techniques used to selectively pattern hepatocytes and 3T3-J2 fibroblasts within the wells of the array. The functional studies used to demonstrate the synthetic and metabolic capacity of the array are outlined in this article. These studies demonstrate that the hepatocytes contained within the array are capable of continuous, steady-state albumin synthesis (78.4 microg/day, sigma = 3.98 microg/day, N = 8) and urea production (109.8 microg/day, sigma = 11.9 microg/day, N = 8). In the final section of the article, these results are discussed as they relate to the final goal of this research effort, the development of an array of primary hepatocytes for use in physiologically relevant toxicology studies.

3T3 Cells↗

Panning of multiple subsets of leukocytes on antibody-decorated poly(ethylene) glycol-coated glass slides.

The antibody (Ab) array format provides a unique opportunity to pan and characterize multiple leukocyte subsets in parallel. However, the questions of reproducibility and robustness of leukocyte panning on Ab arrays need to be answered for this technology to become an immunophenotyping tool. The present study sought to address several of these questions, including: (1) purity of leukocyte subsets captured on Ab regions, (2) dynamics of leukocyte binding, (3) elimination of non-specific cell adhesion, and (4) standardization of cell washing conditions. Abs for CD4 T-cells, CD8 T-cells, CD36 monocytes, and CD16b neutrophils were dispensed onto standard glass slides containing a thin film of poly(ethylene glycol) (PEG) hydrogel. PEG gel coating was highly effective in eliminated non-specific cell adhesion on the surface. Incubation of the Ab arrays with red blood cell (RBC) depleted whole blood resulting in antigen-specific panning of leukocyte subsets on the respective Ab domains. A flow through chamber was employed to determine optimal shear stress conditions for removal of non-specifically attached cells. The purity of the four subsets remaining on the surface after washing was determined by Wright staining and immunofluorescence, and was found to be as follows: CD4 T-cells (99.2+/-0.3%), CD8 T-cells (98.7+/-0.3%), CD36 monocytes (97.2+/-0.9%), and CD16b neutrophils (99.1+/-0.6%). In conclusion, the methods described in this study allow to separate whole blood into pure leukocyte subsets with minimal sample preparation and handling. These approaches will be valuable in the future development of Ab arrays as tools for quantitative immunophenotyping of leukocytes.

Antibodies↗

Magnetically and biologically active bead-patterned hydrogels.

We present a new approach to the direct patterning of biologically and magnetically active microbeads in nonbiofouling polymer scaffolds for use in microfluidic devices. Briefly, the process involves treatment of a glass substrate, conformal contact bonding of a PDMS microchannel on the substrate, filling of the channel with beads and prepolymer solution, and UV-initiated photopolymerization of a mask-defined pattern using a standard inverted microscope. This versatile and simple method allows for the rapid fabrication of dispersed or packed bead patterns in poly(ethylene glycol) (PEG) hydrogels that are covalently linked to glass surfaces. By exploiting the relative opacity of the microbeads used, we are able to create both partially exposed and fully encapsulated bead patterns. To demonstrate the utility of this new technology, we separated magnetic bead-bound B lymphocytes from T lymphocytes on a PEG-encapsulated magnetic filtration platform and also captured B cells directly on patterned, protein-decorated beads in a flow-through microfluidic device. Beyond cell sorting, the accurate patterning of industrially standardized, chemically diverse microbeads may have significant implications for microchip-based analyte detection.

B-Lymphocytes↗

Universal microfluidic gradient generator.

The study of cellular responses to chemical gradients in vitro would greatly benefit from experimental systems that can generate precise and stable gradients comparable to chemical nonhomogeneities occurring in vivo. Recently, microfluidic devices have been demonstrated for linear gradient generation for biological applications with unmatched accuracy and stability. However, no systematic approach exists at this time for generating other gradients of target spatial configuration. Here we demonstrate experimentally and provide mathematical proof for a systematic approach to generating stable gradients of any profile by the controlled mixing of two starting solutions.

Microfluidics↗

Antiproteolytic action of orally delivered insulin using pH-responsive hydrogels in a rat burn model.

Subcutaneously delivered small doses of insulin has shown beneficial effects on burn injury-induced muscle wasting and wound healing. To improve the method of insulin treatment for clinical settings, this study investigated the effect of insulin delivered orally using pH-responsive poly(methacrylic-g-ethylene glycol) (P(MAA-g-EG)) hydrogels in a 20% total burn surface area rat burn injury model. P(MAA-g-EG) were synthesized in-house and insulin release characteristics were performed in vitro. Young rats weighing 80-150 g were subjected to 15-20% total body surface area burn injury and treated with insulin-containing hydrogels enclosed in gelatin capsules for 3 days. The dosage was adjusted to match 0.25 U (day 1), 0.5U (day 2), and 1.0 U (day 3) per 100 grams of body weight. All animals were housed in metabolic cages and their physical activity, body weight, food consumption, water uptake, circulating glucose levels, and urinary tyrosine content were monitored for 4 to 15 days after burn. Results show that the orally delivered insulin restored the body weight of burned rats and influenced wound healing, similar to subcutaneous delivery. Measured glucose levels showed significantly less perturbation, suggesting the possibility of increasing the dosage. In conclusion, muscle wasting can be significantly inhibited by the oral administration of insulin using pH-responsive hydrogels.

Administration, Oral↗

Murine B16 melanomas expressing high levels of the chemokine stromal-derived factor-1/CXCL12 induce tumor-specific T cell chemorepulsion and escape from immune control.

The chemokine, stromal-derived factor-1/CXCL12, is expressed by normal and neoplastic tissues and is involved in tumor growth, metastasis, and modulation of tumor immunity. T cell-mediated tumor immunity depends on the migration and colocalization of CTL with tumor cells, a process regulated by chemokines and adhesion molecules. It has been demonstrated that T cells are repelled by high concentrations of the chemokine CXCL12 via a concentration-dependent and CXCR4 receptor-mediated mechanism, termed chemorepulsion or fugetaxis. We proposed that repulsion of tumor Ag-specific T cells from a tumor expressing high levels of CXCL12 allows the tumor to evade immune control. Murine B16/OVA melanoma cells (H2b) were engineered to constitutively express CXCL12. Immunization of C57BL/6 mice with B16/OVA cells lead to destruction of B16/OVA tumors expressing no or low levels of CXCL12 but not tumors expressing high levels of the chemokine. Early recruitment of adoptively transferred OVA-specific CTL into B16/OVA tumors expressing high levels of CXCL12 was significantly reduced in comparison to B16/OVA tumors, and this reduction was reversed when tumor-specific CTLs were pretreated with the specific CXCR4 antagonist, AMD3100. Memory OVA-specific CD8+ T cells demonstrated antitumor activity against B16/OVA tumors but not B16/OVA.CXCL12-high tumors. Expression of high levels of CXCL12 by B16/OVA cells significantly reduced CTL colocalization with and killing of target cells in vitro in a CXCR4-dependent manner. The repulsion of tumor Ag-specific T cells away from melanomas expressing CXCL12 confirms the chemorepellent activity of high concentrations of CXCL12 and may represent a novel mechanism by which certain tumors evade the immune system.

Animals↗

Cell handling using microstructured membranes.

Gentle and precise handling of cell suspensions is essential for scientific research and clinical diagnostic applications. Although different techniques for cell analysis at the micro-scale have been proposed, many still require that preliminary sample preparation steps be performed off the chip. Here we present a microstructured membrane as a new microfluidic design concept, enabling the implementation of common sample preparation procedures for suspensions of eukaryotic cells in lab-on-a-chip devices. We demonstrate the novel capabilities for sample preparation procedures by the implementation of metered sampling of nanoliter volumes of whole blood, concentration increase up to three orders of magnitude of sparse cell suspension, and circumferentially uniform, sequential exposure of cells to reagents. We implemented these functions by using microstructured membranes that are pneumatically actuated and allowed to reversibly decouple the flow of fluids and the displacement of eukaryotic cells in suspensions. Furthermore, by integrating multiple structures on the same membrane, complex sequential procedures are possible using a limited number of control steps.

Cell Line, Tumor↗

Size-based microfluidic enrichment of neonatal rat cardiac cell populations.

Native heart consists of myocytes and non-myocytes. We demonstrate here the feasibility of a size-based microfluidic separation of myocytes and non-myocytes from the neonatal rat myocardium. The device consists of a middle channel (50 microm wide, 200 microm tall, and 4 cm long) connected to adjacent side channels by microsieves (80 microm wide, 5 microm tall and 40 microm in length). The side channels increase in width in a flared shape along the length of the device to ensure constant pressure gradient across all sieves. In the first step, non-myocytes were removed from the myocytes by a conventional pre-plating method for 75 min. Subsequently, the non-myocytes were further enriched in a microfluidic device at 20 microl/min. We demonstrated that the cells in the middle and side channels maintained viability during sorting and the ability to attach and grow in culture. Upon culture for 48 h cardiomyocytes from the reservoir (control) and middle channel stained positive for cardiac Troponin I, exhibited a well developed contractile apparatus and contracted spontaneously and in response to electrical field stimulation. Most of the cells in the side channel expressed a non-myocyte marker vimetin. Fluorescent activated cell sorting indicated significant enrichment in the side channel (p < 0.001) for non-myocytes. Original cell suspension had a bimodal cell size distribution with the peaks in the range from 7-9 microm and 15-17 microm. Upon cell sorting the distribution was Gaussian in both side channel and middle channel with the peaks in the range 7-9 microm and 9-11 microm respectively, indicating that the separation by size occurred.

Animals↗

Treatment of fulminant hepatic failure in rats using a bioartificial liver device containing porcine hepatocytes producing interleukin-1 receptor antagonist.

Fulminant hepatic failure (FHF) is a serious clinical condition that is associated with high mortality. There is evidence that FHF is an inflammatory disease, which is supported clinically by elevated serum levels of cytokines. In an effort to develop hepatocytes with additional functions for use in our bioartificial liver (BAL) device, we focused on interleukin-1 (IL-1) blockade as a therapeutic modality. Primary porcine hepatocytes were isolated from the livers of miniature swine and then transfected with an adenoviral vector encoding human interleukin-1 receptor antagonist (AdIL-1Ra). The transfected hepatocytes secreted human IL-1Ra. These transfected hepatocytes were incorporated into a flat-plate BAL device to evaluate their efficacy in treating D-galactosamine (GalN)- induced FHF in a rat model. After extracorporeal perfusion with the BAL device containing the transfected hepatocytes, there were significant reductions in the plasma levels of hepatic enzymes (aspartate aminotransferase and alanine aminotransferase) and cytokines (IL-1 and IL-6), indicating a beneficial effect. Animal survival was significantly improved in the treated group compared to the control group. These experiments demonstrate that combining inflammatory cytokine blockade with a functional BAL device may be an effective therapeutic option in the treatment of FHF.

Adenoviridae↗

Polyelectrolyte nano-scaffolds for the design of layered cellular architectures.

The design of in vitro multilayered cellular architectures that resemble the stratified, lattice-like structure in tissues poses a significant challenge for tissue engineering. There is currently no generally applicable methodology to design multilayered cellular constructs that mimic the structure of tissues in vivo. We report a novel and generalizable approach to create multilayered cellular constructs that addresses these issues. These in vitro constructs comprise alternating layers of cells and nano-scale biocompatible polyelectrolyte (PE) scaffolds. We apply this methodology to address two specific problems in hepatic tissue engineering: the design of in vitro liver sinusoidal structures and the critical need to increase viable cell mass in extracorporeal liver-assist devices. We assembled ultrathin polymer scaffolds on the top of a confluent monolayer of cells by the sequential deposition of oppositely charged PEs. The thickness of the PE scaffold lies in the nanometer range. The PE scaffold plays a dual role. First, it is a technique to culture hepatocytes in vitro that maintains their morphology, cytoskeletal structure, and liver-specific functions. Second, the nano-scaffold provides a cell-adhesive surface on which a second layer of cells can be cultured, resulting in layered architectures. We have used this approach to design layered three-dimensional hepatocyte-PE-hepatocyte constructs, hepatocyte-PE-endothelial cell constructs, and hepatocyte-PE-fibroblast constructs. As a result of its versatility, this approach can, in principle, be used to design layered cellular constructs of any tissue type, and therefore has potentially wide applications in tissue engineering, bioreactor devices, and in drug delivery. This methodology has the potential to generate realistic in vitro constructs of any tissue type.

3T3 Cells↗

3-O-methyl-D-glucose improves desiccation tolerance of keratinocytes.

Transplantation of autologous skin grafts and tissue engineered skin replacements for the treatment of burns, trauma, and ulcerative wounds has been shown to restore a protective barrier to infection and fluid loss, reduce heat loss, provide mechanical strength, diminish pain, and dampen the hypermetabolic stress response to thermal injury. Patencies of these grafts depend mainly on the high viability and sustained function of the enmeshed keratinocytes. With growing demand in tissue replacement therapies, development of successful and economical preservation techniques for skin grafts and replacements becomes essential. In this regard, if attained, desiccated state storage offers an economical solution to availability, storage, and transportation problems. Recent studies indicate that carbohydrates are very efficient in stabilizing mammalian cells against various types of stresses, including those associated with cryopreservation and desiccation. In this study we introduce the use of 3-O-methyl-D-glucose (3-OMG), a nonmetabolizable glucose derivative, as a new means of providing protection for keratinocytes undergoing desiccation. We show that with decreasing water contents, viability of the cells decreases; however, at the same water content the immediate post-rehydration viability and long-term survival of the cells exposed to 3-OMG are much higher than those of controls.

Burns↗

Nonmetabolizable glucose compounds impart cryotolerance to primary rat hepatocytes.

We herein report a novel method for the cryopreservation of hepatocytes using a non-metabolizable glucose derivative in an attempt to mimic the natural cryoprotective adaptations observed in freeze-tolerant frogs. Primary rat hepatocytes were loaded with 3-O-methyl glucose (3OMG) through endogenous glucose transporters without evident toxicity. The 3OMG-loaded hepatocytes were then frozen in a controlled rate freezer down to -80 degrees C and stored in liquid nitrogen at -196 degrees C. Hepatocytes cryopreserved with a relatively small amount of intracellular 3OMG (<0.2 M) showed high post-thaw viability and maintained long-term hepatospecific functions, including synthesis, metabolism, and detoxification. Metabolite uptake and secretion rates were also largely preserved in the cryopreserved hepatocytes. This is the first study to demonstrate the use of the non-metabolizable glucose derivative 3OMG in hepatocyte cryopreservation.

3-O-Methylglucose↗

Microfluidic system for measuring neutrophil migratory responses to fast switches of chemical gradients.

Experimental systems that provide temporal and spatial control of chemical gradients are required for probing into the complex mechanisms of eukaryotic cell chemotaxis. However, no current technique can simultaneously generate stable chemical gradients and allow fast gradient changes. We developed a microfluidic system with microstructured membranes for exposing neutrophils to fast and precise changes between stable, linear gradients of the known chemoattractant Interleukin-8 (IL-8). We observed that rapidly lowering the average concentration of IL-8 within a gradient, while preserving the direction of the gradient, resulted in temporary neutrophil depolarization. Fast reversal of the gradient direction while increasing or decreasing the average concentration also resulted in temporary depolarization. Neutrophils adapted and maintained their directional motility, only when the average gradient concentration was increased and the direction of the gradient preserved. Based on these observations we propose a two-component temporal sensing mechanism that uses variations of chemokine concentration averaged over the entire cell surface and localized at the leading edge, respectively, and directs neutrophil responses to changes in their chemical microenvironment.

Chemotaxis↗

Trehalose uptake through P2X7 purinergic channels provides dehydration protection.

The tetra-anionic form of ATP (ATP4-) is known to induce monovalent and divalent ion fluxes in cells that express purinergic P2X7 receptors and with sustained application of ATP it has been shown that dyes as large as 831 Da can permeate the cell membrane. The current study explores the kinetics of loading alpha,alpha-trehalose (342 Da) into ATP stimulated J774.A1 cells, which are known to express the purinergic P2X7 receptor. Cells that were incubated at 37 degrees C in a 50 mM phosphate buffer (pH 7.0) containing 225 mM trehalose and 5 mM ATP, were shown to load trehalose linearly over time. Concentrations of approximately 50 mM were reached within 90 min of incubation. Cells incubated in the same solution at 4 degrees C loaded minimally, consistent with the inactivity of the receptor at low temperatures. However, extended incubation at 37 degrees C (>60 min) resulted in zero next-day survival, with adverse effects appearing even with incubation periods as short as 30 min. By using a two-step protocol with a short time period at 37 degrees C to allow pore formation, followed by an extended loading period on ice, cells could be loaded with up to 50 mM trehalose while maintaining good next day recovery (49 +/- 12% by Trypan blue exclusion, 56 +/- 20% by alamarBlue assay). Cells porated by this method and allowed an overnight recovery period exhibited improved dehydration tolerance suggesting a role for ATP poration in the anhydrous preservation of cells.

Adenosine Triphosphate↗