PubMed Health⌕ Search

Biomedical subjects

Meleze Hocini

Publications and source records attributed to Meleze Hocini.

13 recordsLinked to original sources

Reverse remodeling of the left cardiac chambers after catheter ablation after 1 year in a series of patients with isolated atrial fibrillation.

BACKGROUND: Isolated atrial fibrillation (AF) is associated with mild enlargement of the left atrium (LA) and left ventricular (LV) diastolic dysfunction. The impact of ablation of isolated AF on left chamber size and function is unclear, and whether diastolic dysfunction is the cause or the consequence of AF remains unknown. The objective of this prospective study was to evaluate the impact of sinus rhythm restoration by catheter ablation on LV diastolic dysfunction, LA morphology, and mechanical function. METHODS AND RESULTS: Forty-eight patients with isolated AF were studied by serial echocardiographic studies at baseline and at 1-, 3-, 6-, 9-, and 12-month intervals after radiofrequency ablation. LA dimensions and mechanical function and LV systolic and diastolic functions were evaluated at each time interval. Diastolic function was assessed with conventional Doppler parameters and new indexes such as tissue Doppler imaging, mitral flow propagation velocity, and combined criteria. LV diastolic dysfunction was present in paroxysmal and chronic AF patients with a reduction of tissue Doppler imaging lateral early diastolic peak velocity in 37% (P<0.001) and 48% (P<0.01), respectively, compared with healthy control subjects. At the end of the follow-up, LA area decreased significantly by 18% (P<0.001) in paroxysmal and 23% (P<0.05) in chronic AF patients. Diastolic function improved significantly with an increase in lateral early diastolic peak velocity of 29% (P<0.001) in paroxysmal AF and 46% (P<0.05) in chronic AF patients. A significant increase in LV ejection fraction was also noted for both groups: 7.7% and 18.8%, respectively. CONCLUSIONS: This study demonstrates reverse morphological remodeling of the LA and improvement of LV diastolic and systolic functions after restoration of sinus rhythm by ablation for isolated AF. Because patients with isolated AF have none of the traditional causes of LV diastolic dysfunction, our findings suggest that AF may be partly the cause rather than the consequence of diastolic dysfunction.

Adult↗

Prospective randomised comparison of irrigated-tip and large-tip catheter ablation of cavotricuspid isthmus-dependent atrial flutter.

BACKGROUND: Radiofrequency (RF) ablation of cavotricuspid isthmus (CTI) dependent flutter can be performed using different types of ablation catheters. It has been proposed that irrigated and large-tip catheters are capable of creating larger lesions, resulting in greater efficacy. This prospective, randomised clinical study compared the efficacy of irrigated and large-tip catheters of different designs. METHODS: Eighty patients (69 men, 66+/-11 years) undergoing de novo RF ablation of CTI-dependent flutter were randomised to ablation using one of the following catheters: (i) externally-irrigated 20), (ii) internally-cooled (n=20), (iii) single sensor, 8-mm tip (n=20), or (iv) double sensor, 8-mm tip (n=20). The study endpoint was the demonstration of bidirectional CTI conduction block within 12 min of cumulative RF delivery. Crossover to the externally-irrigated catheter was permitted if this was not achieved. The ablation and procedural parameters, safety and efficacy were compared. RESULTS: The primary endpoint was achieved in 64 patients (80%), including all 20 patients randomised to the externally-irrigated catheter. Crossover was required in 16 patients: 9 initially using the internally-cooled catheter (45%), 3 using single-sensor, 8-mm-tip (15%), and 4 using double-sensor, 8-mm-tip (20%) catheters. The higher initial failure rate with the internally-cooled-tip catheter was significant compared to the externally-irrigated (p = 0.001) and single-sensor, 8-mm-tip (p = 0.04) catheters. The externally-irrigated catheter achieved the study endpoint more frequently with fewer RF applications of shorter duration compared to the internally-cooled-tip catheter and 8-mm-tip catheters, the difference being significant compared with internally cooled ablation. No major complications were observed. CONCLUSION: Among commonly used ablation catheters, the externally-irrigated catheter has a higher efficacy for rapid achievement of CTI block.

Aged↗

Radiation exposure during radiofrequency catheter ablation for atrial fibrillation.

RF catheter ablation of paroxysmal atrial fibrillation (PAF) is associated with prolonged fluoroscopy. The procedural duration and fluoroscopic exposure to patients and medical staff were recorded and compared among 43 ablation procedures for PAF, 20 for common atrial flutter, and 16 for accessory pathways. Patient radiation exposure was measured by dosimeters placed over the xyphoid, while that of physicians and nurses was measured by dosimeters placed outside and inside the lead apron. The mean fluoroscopy time was 57 +/- 30 minutes for PAF, 20 +/- 10 minutes for common flutter, and 22 +/- 21 minutes for accessory pathway ablation. The patient median radiation exposure was 1110 microSv for PAF, compared with 500 microSv for common flutter and 560 microSv for accessory pathway ablation (P < 0.01). The median radiation exposure to physician and nurse inside the lead apron were, respectively, 2 microSv and 3 microSv for PAF, 1 microSv and 2 microSv for common flutter, and < 0.5 microSv and 3 microSv for accessory pathway ablations. RF catheter ablation for PAF was associated with prolonged fluoroscopy times and a twofold higher radiation exposure to the patient and physician compared with other ablation procedures. Assuming 300 procedures/year, radiation exposure to the medical staff was below the upper recommended annual dose limit.

Atrial Fibrillation↗

Nonpulmonary vein foci: do they exist?

Though the majority of foci triggering atrial fibrillation (AF) have been mapped to the pulmonary veins (PV), recurrence of paroxysmal AF after isolation of all four pulmonary veins indicates the presence of other foci. In a series of 160 consecutive patients who underwent PV ablation, endocardial mapping of AF and ectopy recurring after PV isolation was performed. Thirty-six patients (24%) had a total of 85 non-PV foci; 39 were mapped to the ostia of ablated PVs, 30 to the posterior left atrium (LA), 5 to other parts of the LA, 5 to the right atrium (RA), 4 to the coronary sinus (CS), and 3 to the superior vena cava (SVC) (including one persistent left SVC). Mapping was confirmed by successful ablation. At least 16 foci could not be localized and after a follow-up of 8 +/- 6 months, 68% of patients were free of AF without any antiarrhythmic treatment. The occurrence of non-PV foci correlated with recurrence of AF, perhaps as a correlate of insufficient ostial ablation. These data reinforce the requirement for more proximal disconnection of the PVs by performing ablation within the LA. In patients with non-PV foci that are difficult to map conventionally, the use of surface ECG data, or multielectrode contact or noncontact mapping arrays, or substrate modifying/excluding ablation may be helpful in ablating these foci and therefore eliminating AF.

Atrial Fibrillation↗

Safety and efficacy of cryoablation of accessory pathways adjacent to the normal conduction system.

UNLABELLED: Cryoablation of Septal Accessory Pathways. INTRODUCTION: Catheter ablation has become a routine treatment for patients with Wolff-Parkinson-White syndrome because of its low risk and high efficacy; however, radiofrequency ablation in the septum close to the AV node or His bundle still carries a definite risk for AV block. Cryoenergy catheter ablation has recently become available. This technique has specific features, such as the ability to create reversible loss of function to predict the effects of ablation (ice mapping) and the adherence of the catheter tip to the endocardium with freezing, which avoids the risk for dislodgment. Both of these characteristics may minimize the risk of complications. The aim of this study was to analyze the effectiveness and safety of catheter cryoablation in 20 patients with para-Hisian or midseptal accessory pathways (AP). METHODS AND RESULTS: Eleven patients with para-Hisian and 9 patients with midseptal AP underwent catheter cryoablation. Ice mapping at -30 degrees C was performed to ascertain the disappearance of AP conduction and the absence of impairment of AV nodal conduction. If the expected result was obtained, cryoablation was performed by lowering the temperature to -75 degrees C for 4 minutes in order to create a permanent lesion. Cryoablation was successful in all patients using a mean of 1.2 +/- 0.4 applications. Recurrences occurred in 4 patients (20%) who underwent a second successful cryoablation session. No complications were observed. CONCLUSION: Cryoablation appears to be a safe and effective technique for ablation of APs close to the AV node or His bundle because of the ability to predict the acute effects of ablation with ice mapping before creation of an irreversible lesion.

Arrhythmias, Cardiac↗

QRST subtraction combined with a pacemap catalogue for the prediction of ectopy source by surface electrocardiogram in patients with paroxysmal atrial fibrillation.

OBJECTIVES: This study evaluated the use of ectopic P-wave morphology to localize pulmonary vein (PV) and non-PV sources of atrial ectopics in patients with paroxysmal atrial fibrillation (PAF). BACKGROUND: The vectorial information embodied in the morphology of ectopic P waves is concealed by overlying T waves. METHODS: The P-wave morphology of 56 ectopics was prospectively analyzed in 44 patients with PAF (age, 52 +/- 12 years; 36 male) by subtracting the adjacent QRST from the QRST-ectopic P-wave complex using custom-designed software. Subtraction fidelity was validated in 15 other patients (55 +/- 19 years, 11 male) by comparing drive beats with simulated ectopics (S2 from the same site) unmasked by subtracting overlying QRST. An algorithm combined with PV pacemaps was used to predict PV sources. Subtracted ectopic P-wave morphologies after PV disconnection were compared with PV and non-PV site pacemaps. Localization was confirmed by mapping and successful ablation. RESULTS: A > or =10-lead electrocardiogram (ECG) match was observed in 92% of 644 simulated ectopics (coupling intervals: 190 to 520 ms). In PAF patients, 37 spontaneous ectopics originated from the PV, while 19 were noted after PV disconnection. Using the P-wave algorithm alone, correct prediction of PV origin was achieved in 30/37 ectopics (81%). Combination with PV pacemaps allowed correct prediction in 34/37 (92%). After PV disconnection, ECG localization predicted successful ablation sites in 16/19 (84%). CONCLUSIONS: Comparison of subtracted ectopic P waves with a pacemap catalogue provides a simple and accurate 12-lead ECG-based method for localization, which can facilitate ablation of arrhythmia triggers irrespective of origin from the PV or elsewhere.

Adult↗

Left atrial appendage activity masquerading as pulmonary vein potentials.

BACKGROUND: Despite extensive proximal ablation, all potentials frequently cannot be eliminated from the left pulmonary veins (PV). Methods and Results- PV electrograms were analyzed during sinus rhythm, coronary sinus, and left atrial appendage (LAA) pacing, and PV and LAA angiography performed. During pacing, an initial low-amplitude slow potential was recorded on the anterior aspect of the left superior PV and anticipated with shortest activation time by LAA pacing. Its timing coincided with posterior LAA activation, shown to be immediately adjacent to the left superior PV by angiography. In the left inferior PV, the first potential was smaller and less sharp, coinciding with adjacent low LA activation. Angiographically, the LAA was at least 15 mm from the left inferior PV. The second sharper potential in both left PVs was eliminated by proximal ablation. CONCLUSION: Far field LAA activity consistently adds to PV myocardial electrograms in the left superior PV whereas lower, less sharp extravenous potentials in the left inferior PV originate from the inferior LA. They can be identified by LAA and coronary sinus pacing.

Action Potentials↗

Role of Purkinje conducting system in triggering of idiopathic ventricular fibrillation.

Ventricular fibrillation is the main mechanism of sudden cardiac death, but the source of its spontaneous initiation has not been mapped. 16 patients were investigated by electrography and radiofrequency ablation after resuscitation from recurrent idiopathic ventricular fibrillation. Triggers of ventricular fibrillation originated from various locations within the Purkinje system in 12 patients and from the ordinary myocardial muscle in four. The accuracy of mapping was confirmed by acute elimination of triggers by radiofrequency delivery, and there was no recurrence of ventricular fibrillation in 14 patients. Long-term follow-up is necessary to establish that ablation is curative and avoids use of a defibrillator.

Adolescent↗

Benefit of atrial pacing in sleep apnea syndrome.

BACKGROUND: Many patients with sleep apnea syndrome have nocturnal bradycardia, paroxysmal tachyarrhythmias, or both, which can be prevented by permanent atrial pacing. We evaluated the effect of using cardiac pacing to increase the heart rate during sleep in patients with sleep apnea syndrome. METHODS: We studied 15 patients (11 men and 4 women; mean [+/-SD] age, 69+/-9 years) with central or obstructive sleep apnea who had received permanent atrial-synchronous ventricular pacemakers for symptomatic sinus bradycardia. All patients underwent three polysomnographic evaluations on consecutive nights, the first night for base-line evaluation and then, in random order, one night in spontaneous rhythm and one in dual-chamber pacing mode with atrial overdrive (basic rate, 15 beats per minute faster than the mean nocturnal sinus rate). The total duration and number of episodes of central or obstructive sleep apnea or hypopnea were analyzed and compared. RESULTS: The mean 24-hour sinus rate during spontaneous rhythm was 57 +/- 5 beats per minute at base line, as compared with 72 +/- 3 beats per minute with atrial overdrive pacing (P<0.001). The total duration of sleep was 321 +/- 49 minutes in spontaneous rhythm, as compared with 331 +/- 46 minutes with atrial overdrive pacing (P=0.48). The hypopnea index (the total number of episodes of hypopnea divided by the number of hours of sleep) was reduced from 9 +/- 4 in spontaneous rhythm to 3 +/-3 with atrial overdrive pacing (P<0.001). For both apnea and hypopnea, the value for the index was 28 +/- 22 in spontaneous rhythm, as compared with 11 +/- 14 with atrial overdrive pacing (P<0.001). CONCLUSIONS: In patients with sleep apnea syndrome, atrial overdrive pacing significantly reduces the number of episodes of central or obstructive sleep apnea without reducing the total sleep time.

Aged↗

Successful ablation of Hisian ectopy identified by a reversed His bundle activation sequence.

Junctional ectopy or tachycardia have been mapped and ablated in the atrioventricular node or its posterior extensions. There is no report of Hisian ectopy convincingly demonstrated and then successfully treated by ablation. A 39-year-old man presented with a 9-year history of recurrent supraventricular ectopy refractory to medical treatment. Intracardiac mapping revealed that the ectopy originated from the His bundle, which was indicated by a reversed His bundle activation sequence during ectopy compared to that during sinus rhythm, while the right bundle branch potential was anterogradely activated. Low power RF energy delivered to the site of earliest activation completely abolished the ectopic activity without modification of Hisian or atrioventricular conduction. After a 12-month followup, the patient remains free of recurrence.

Adult↗