PubMed Health⌕ Search

Biomedical subjects

Meng-Lin Li

Publications and source records attributed to Meng-Lin Li.

11 recordsLinked to original sources

Estimating the blood velocity vector using aperture domain data.

Most conventional blood flow estimation methods measure only the axial component of the blood velocity vector. In this study, we developed a new method for two-dimensional (2-D) velocity vector estimation in which time shifts resulting from blood motion are calculated for the individual channels using aperture domain data. This allows the construction of a time-shift profile along the array direction as a function of channel index, which is approximated by a first-order polynomial whose zeroth-order and first-order terms can be used to determine the axial and lateral velocity components, respectively. The efficacy of the proposed method was verified by simulations and experiments in which the transducer array had 64 elements, an aperture size of 1.96 cm, and a center frequency of 5 MHz. The flow velocity ranged from 5 to 35 cm/s and the Doppler angle ranged from 0 degrees to 90 degrees. The experimental results show that the accuracy of axial velocity estimation is higher for the new method than for the autocorrelation-based conventional method when the signal-to-noise ratio is larger than 0 dB. The mean estimation error for the axial velocity component is 2.18% for the new method, compared to 4.51% for the conventional method. The mean estimation error for the lateral velocity component is 15%, which is comparable to existing methods.

Algorithms↗

In vivo imaging and characterization of hypoxia-induced neovascularization and tumor invasion.

Hypoxia is a critical event in tumor progression and angiogenesis. Hypoxia can be detected noninvasively by a novel spectroscopic photoacoustic tomography technology (SPAT) and this finding is supported by our molecular biology investigation aimed to elucidate the etiopathogenesis of SPAT detected hypoxia and angiogenesis. The present study provides an integrated approach to define oxygen status (hypoxia) of intracranial tumor xenografts using spectroscopic photoacoustic tomography. Brain tumors can be identified based on their distorted vascular architecture and oxygen saturation (SO2) images. Noninvasive in vivo tumor oxygenation imaging using SPAT is based on the spectroscopic absorption differences between oxyhemoglobin (O2Hb) and deoxyhemoblobin (HHb). Sprague-Dawley rats inoculated intracranially with ENU1564, a carcinogen-induced rat mammary adenocarcinoma cell line, were imaged with SPAT three weeks post inoculation. Proteins important for tumor angiogenesis and invasion were detected in hypoxic brain foci identified by SPAT and were elevated compared with control brain. Immunohistochemistry, Western blotting, and semi-quantitative RT-PCR showed that HIF-1 alpha, VEGF-A, and VEGFR2 (Flk-1) protein and mRNA expression levels were significantly higher (P < 0.05) in brain tumor tissues compared to normal brain. Gelatin zymography and RT-PCR demonstrated the upregulation of MMP-9 in tumor foci compared with brain control. Together these results suggest the critical role of hypoxia in driving tumor angiogenesis and invasion through upregulation of target genes important for these functions. Moreover this report validates our hypothesis that a novel noninvasive technology (SPAT) developed in our laboratory is suitable for detection of tumors, hypoxia, and angiogenesis.

Animals↗

Improved in vivo photoacoustic microscopy based on a virtual-detector concept.

Recently an in vivo high-resolution backward-mode photoacoustic microscope was developed that shows potential for applications in dermatology and related cancer research. However, the limited depth of focus of the large-numerical-aperture (NA) ultrasonic lens employed in this system causes the image quality to deteriorate significantly in the out-of-focus region. To solve this problem, we devised and explored, for the first time to our knowledge, a virtual-detector-based synthetic-aperture focusing technique, combined with coherence weighting, for photoacoustic microscopy with such a large-NA transducer. Images of phantoms show that the proposed technique improves the -6 dB lateral resolution from 49-379 to 46-53 microm and increases the signal-to-noise ratio by up to 29 dB, depending on the distance from the ultrasonic focal point. In vivo experiments show that the technique also provides a clearer representation of the vascular distribution in the rat's scalp.

Algorithms↗

[Pharmacodynamic study of Relinqing granules on bacterial pyelonephritis model in rats].

OBJECTIVE: To observe the effects of Relinqing granules (powder of Polygonum capitatum extract) on the bacterial pyelonephritis model in rats. METHOD: The rat bacterial pyelonephritis model was induced by injecting the escherichia coli ATCC-25922 into kidney parenchyma. The rats were divided ramdamly into Relinqing groups(52.32, 26.16 g x kg(-1)), norflorin group (0.03 g x kg(-1)), model group and normal control group, and were given experimental drugs by gastrogavage. The contents of leucocytes (WBC), occult bloo (BLD), glucose (GLU), protein (PRO), ketones, bilirubin and urobilinagen in urine were determined. RESULT: As compared with the model group, Relinqing granules 6.0 g x kg(-1) (crude drug 52.32 g x kg(-1)) could decrease significantly the contents of WBC and BLD in urine and, however, had no markedly effects on the other biochemical parameters of urine. CONCLUSION: Relinqqing granule has significant effects of decreasing urine WBC and BLD on the bacterial pyolonephritis in rats.

Animals↗

Adaptive imaging using an optimal receive aperture size.

Sidelobe contribution from off-axis targets degrades image quality in a coherent array imaging system. In ultrasound imaging, focusing errors resulting from sound-velocity inhomogeneities in human tissue--also known as phase aberrations reduce the coherence of the received signals and elevate the sidelobe level. This paper proposes an adaptive receive-aperture technique based on thresholding of the coherence factor (CF). The CF describes the coherence of the received array signals and can be used as an index of focusing quality. This paper demonstrates that thresholding of the CF allows the mainlobe-dominated signals to be distinguished from the sidelobe-dominated signals, after which the receive-aperture size at each imaging position can be optimally determined so as to enhance the mainlobe-dominated signals and suppress the sidelobe-dominated signals. Thus, image quality degradation resulting from sound-velocity inhomogeneities can be reduced. Simulations and measured ultrasound data are used to evaluate the efficacy of the proposed technique. The characteristics of the proposed technique including the effects of the signal-to-noise ratio (SNR) and the transmit focal depth, and speckle reduction are discussed. The proposed technique is also compared with the parallel adaptive receive compensation algorithm and shown to produce a better improvement in image quality.

Algorithms↗

Improved synthetic aperture focusing technique with applications in high-frequency ultrasound imaging.

Synthetic aperture focusing using a virtual source was used previously to increase the penetration and to extend the depth of focus in high-frequency ultrasonic imaging. However, the performance of synthetic aperture focusing is limited by its high sidelobes. In this paper, an adaptive weighting technique based on a focusing-quality index is introduced to suppress the sidelobes. The focusing-quality index is derived from the spatial spectrum of the scan-line data along the mechanical scan direction (i.e., the synthetic aperture direction) after focusing delays relative to the virtual source have been applied. The proposed technique is of particular value in high-frequency ultrasound in which dynamic focusing using array transducers is not yet possible. Experimental ultrasound data from a 50-MHz imaging system with a single-crystal transducer (f-number = 2) are used to demonstrate the efficacy of the proposed technique on both wire targets and speckle-generating objects. An in vivo experiment also is performed on a mouse to further demonstrate the effectiveness. Both 50-MHz fundamental imaging and 50-MHz tissue harmonic imaging are tested. The results clearly demonstrate the effectiveness in sidelobe reduction and background-noise suppression for both imaging modes. The principles, experimental results, and implementation issues of the new technique are described in this paper.

Algorithms↗

A digital ultrasonic system for small animal imaging.

In this paper, a 50 MHz digital ultrasonic imaging system designed for small animals and its applications to mouse embryos and tumors are presented. Utilizing the programmability of a fully digital system, several advanced imaging techniques are developed and implemented. A synthetic aperture focusing technique is implemented to increase the penetration and extend the depth of focus of a mechanical scan system using a high frequency single crystal transducer. An adaptive weighting technique is introduced to further reduce the sidelobes and enhance image contrast. Experimental results demonstrate efficacy of the proposed two-step adaptive focusing technique. For flow imaging, several flow estimation algorithms are evaluated. Simulations and flow phantom experiments show that the butterfly search technique offers superior flow imaging performance particularly when the SNR is low and the pulse bandwidth is high. The system is tested by imaging mouse embryos and microcirculation of a mouse tumor in vivo. It is demonstrated that the system is capable of simultaneously acquiring B-mode, color Doppler mode and power Doppler mode small animal images. The system set-up, adaptive focusing technique, flow estimation algorithms and imaging results are shown.

Algorithms↗

Adaptive imaging using the generalized coherence factor.

Sound-velocity inhomogeneities degrade both spatial and contrast resolutions. This paper proposes a new adaptive imaging technique that uses the generalized coherence factor (GCF) to reduce the focusing errors resulting from the sound-velocity inhomogeneities. The GCF is derived from the spatial spectrum of the received aperture data after proper receive delays have been applied. It is defined as the ratio of the spectral energy within a prespecified low-frequency range to the total energy. It is demonstrated that the low-frequency component of the spectrum corresponds to the coherent portion of the received data, and that the high-frequency component corresponds to the incoherent portion. Hence, the GCF reduces to the coherence factor defined in the literature if the prespecified low-frequency range is restricted to dc only. In addition, the GCF is also an index of the focusing quality and can be used as a weighting factor for the reconstructed image. The efficacy of the GCF technique is demonstrated for focusing errors resulting from the sound-velocity inhomogeneities. Simulations and real ultrasound data are used to evaluate the efficacy of the proposed GCF technique. The characteristics of the GCF, including the effects of the signal-to-noise ratio and the number of channels, are also discussed. The GCF technique also is compared with the correlation-based technique and the parallel adaptive receive compensation algorithm; the improvement in image quality obtained with the proposed technique rivals that of the latter technique. In the presence of a displaced phase screen, this proposed technique also outperforms the correlation-based technique. Computational complexity and implementation issues also are addressed.

Algorithms↗

Improved Fourier-transform-based parallel receive beam formation.

A Fourier transform (FT)-based technique for forming parallel receive beams has been previously employed to increase the imaging frame rate in ultrasonic imaging. However, the image quality in FT-based parallel reconstruction is degraded because differences in range focusing delays are ignored and a wide transmit beam needs to be used. In this paper, an adaptive weighting technique based on a focusing-quality index is used to reduce the sidelobes of the FT-derived parallel receive beams. The focusing-quality index is derived from the spatial spectrum of the received aperture data after the receive delays have been applied. Since the spatial spectrum of the baseband aperture data is also used to approximate receive beams in FT-based parallel reconstruction, the adaptive weighting technique can be directly combined with the FT-based technique for forming parallel receive beams with only a slight increase in system complexity. Real ultrasound data are used to demonstrate the efficacy of the proposed technique on both wire targets and speckle-generating objects. The results clearly demonstrate the effectiveness in reducing the sidelobes. In addition, the image background noise is suppressed. The principles, experimental results, and the extension of the proposed technique to 3D ultrasound imaging are described in this paper.

Fourier Analysis↗

Elastic modulus measurements of human liver and correlation with pathology.

Viral hepatitis causes fibrosis in the liver and may change mechanical properties of the liver. To evaluate the impact of fibrosis on elastic properties of human liver and to investigate potential benefits of ultrasonic elasticity imaging, 19 fresh human liver samples and 1 hepatic tumor (focal nodular hyperplasia) sample obtained during operations were studied. Simple 1-D estimates based on the cyclic compression-relaxation method were performed. Elastic modulus values were derived from the predetermined strain (controlled by a step motor system) and the stress values (measured by an electronic balance). Each specimen subsequently received histologic examination and a grade of liver fibrosis was scored from 0 to 5. Results show that the elastic modulus values were on the order of several hundreds to thousands of Pascals. The elastic modulus generally increased with the fibrosis grade, although some discrepancies existed at the middle grades of fibrosis (scores 1 to 3). The correlation between the fibrosis score and the elastic modulus was significant (p < 0.01) based on the statistical analysis using the Pearson correlation method. In addition, the relation between the elastic modulus and the fibrosis grade generally exhibited a quadratic trend. It was concluded that severity of fibrosis had a good correlation with stiffness of the liver. Results also indicated that the elasticity imaging of the liver may provide significant clinical values if the elastic modulus can be accurately measured.

Elasticity↗

Three-dimensional imaging of skin melanoma in vivo by dual-wavelength photoacoustic microscopy.

Dual-wavelength reflection-mode photoacoustic microscopy is used to noninvasively obtain three-dimensional (3-D) images of subcutaneous melanomas and their surrounding vasculature in nude mice in vivo. The absorption coefficients of blood and melanin-pigmented melanomas vary greatly relative to each other at these two optical wavelengths (764 and 584 nm). Using high-resolution and high-contrast photoacoustic imaging in vivo with a near-infrared (764-nm) light source, the 3-D melanin distribution inside the skin is imaged, and the maximum thickness of the melanoma (approximately 0.5 mm) is measured. The vascular system surrounding the melanoma is also imaged with visible light (584 nm) and the tumor-feeding vessels found. This technique can potentially be used for melanoma diagnosis, prognosis, and treatment planning.

Acoustics↗