Respiratory protection from isocyanate exposure in the autobody repair and refinishing industry.

This study, part of the Survey of Painters and Repairers of Auto bodies by Yale (SPRAY), evaluated the effectiveness of respiratory protection against exposure to aliphatic polyisocyanates. A total of 36 shops were assessed for respiratory protection program completeness; 142 workers were measured for respirator fit factor (FF) using PortaCount Plus respirator fit tester. Twenty-two painters from 21 shops were sampled using NIOSH method 5525 to determine the workplace protection factor (WPF) of negative pressure, air-purifying half-facepiece respirators equipped with organic vapor cartridges and paint prefilters during spray-painting and priming activities. Only 11 shops (30%) had written respiratory protection programs. Eighty percent of all fit tested workers passed the test on the first try with FF >or= 100, and 92% passed the second test after respirator use training. Overall geometric mean (GM) FF was 1012 for all fit tested workers. Significant differences on pass rate (92% vs. 72%) and on FF (1990 vs. 736) were found between previously fit tested workers vs. nontested workers. Twenty-nine WPF samples were collected. The outside facepiece GM concentration of total isocyanate group (NCO) was 378.4 micro g NCO/m(3) with 96% concentrations exceeding the U.K. short-term exposure limit, 70 micro g NCO/m(3), but no in-facepiece concentrations exceeded the limit. The GM WPF of total NCO was 319 (GSD 4) and the 5th percentile was 54. WPF of total NCO was positively correlated with the duration of painting task. FF positively correlated with WPF when FF was 450. We conclude that negative pressure, air-purifying half-facepiece respirators equipped with organic vapor cartridges and paint prefilters provide effective protection against isocyanate exposure in spray and priming operations if workers are properly trained and fitted.

Adult↗

A laboratory investigation of the effectiveness of various skin and surface decontaminants for aliphatic polyisocyanates.

Isocyanates may cause contact dermatitis and respiratory sensitization leading to asthma. Dermal exposure to aliphatic isocyanates in auto body shops is very common. However, little is known about the effectiveness of available commercial products used for decontaminating aliphatic polyisocyanates. This experimental study evaluated the decontamination effectiveness of aliphatic polyisocyanates for several skin and surface decontaminants available for use in the auto body industry. The efficiency of two major decontamination mechanisms, namely (i) consumption of free isocyanate groups via chemical reactions with active hydrogen components of the decontaminant and (ii) physical removal processes such as dissolution were studied separately for each decontaminant. Considerable differences were observed among surface decontaminants in their rate of isocyanate consumption, of which those containing free amine groups performed the best. Overall, Pine-Sol(R) MEA containing monoethanolamine was the most efficient surface decontaminant, operating primarily via chemical reaction with the isocyanate group. Polypropylene glycol (PPG) had the highest physical removal efficiency and the lowest reaction rate with isocyanates. All tested skin decontaminants performed similarly, accomplishing decontamination primarily via physical processes and removing 70-80% of isocyanates in one wiping. Limitations of these skin decontaminants are discussed and alternatives presented. In vitro testing using animal skins and in vivo testing with field workers are being conducted to further assess the efficiency and identify related determinants.

Automobiles↗

Polyisocyanates in occupational environments: a critical review of exposure limits and metrics.

BACKGROUND: Determination of polyisocyanates is important because they are a major contributor of exposure to the isocyanate functional group in many workplace environments and are capable of inducing sensitization and asthma. However, with multiple different measurement metrics in use, comparison of isocyanate exposure data between studies and development of occupational exposure limits (OELs) for polyisocyanates is difficult. METHODS: An analysis of existing problems in the measurement and regulation of isocyanates is presented based on the published analytical, toxicological, and regulatory literature, and the authors' own analytical data and experience with isocyanates. RESULTS: This analysis supports a need for standardization of isocyanate measurement metrics and provides a framework for the development of an OEL for polyisocyanates. CONCLUSIONS: The total isocyanate group (microg NCO/m(3)) is recommended as the most feasible and practical metric (unit) by which to express polyisocyanate exposures for research, control, and regulatory purposes. The establishment of a comprehensive isocyanate OEL that simplifies the current agent-by-agent approach and expands coverage to polyisocyanates is also recommended.

Air Pollutants, Occupational↗

Isocyanate vapor-induced antigenicity of human albumin.

BACKGROUND: The bioreactivity of isocyanate, a leading cause of occupational asthma, has led to uncertainty regarding the chemical's antigenicity and mechanisms that elicit immunopathology. OBJECTIVE: To understand better the biologically relevant antigenic forms of hexamethylene diisocyanate (HDI), commonly used in the auto body industry. METHODS: Human albumin was exposed to HDI vapors through a novel approach designed to model the air-liquid interface of the human airway. Vapor HDI-exposed albumin was characterized by electrophoresis, chemical substitution analysis, mass spectrometry, and serology studies on auto body shop workers (N=203) and HDI asthmatics (N=11). RESULTS: HDI vapors caused significant changes in the shape and/or charge of human albumin, which differed from albumin exposed to liquid phase HDI, with lower isocyanate substitution ratios and distinct electrophoretic mobility. Specific sites of vapor HDI conjugation to albumin were identified at His(247) and Lys(414). Vapor HDI-exposed albumin was specifically recognized by the humoral arm of the human immune system, with a strong dependence on albumin as the carrier. Vapor HDI-exposed albumin-specific IgG titers were significantly associated with HDI exposure (P=.001), and specific IgE was detectable in 55% (6/11) of isocyanate asthmatics versus 1.5% (3/203) of exposed healthy workers. Parallel studies using HDI-exposed albumin conjugates produced by previously published methods showed less significant associations of HDI-specific IgG and IgE with exposure and disease, respectively. CONCLUSION: HDI-albumin conjugates produced by novel vapor phase exposure methods may be more physiologically relevant than those produced by previously published methods and of greater utility in characterizing the immune responses associated with HDI exposure and asthma.

Albumins↗

Isocyanate exposures in autobody shop work: the SPRAY study.

Isocyanates, known to cause respiratory sensitization and asthma, are widely used in automotive refinishing where exposures to aliphatic polyisocyanates occur by both inhalation and skin contact. The work reported here, the characterization of isocyanate exposure in the autobody industry, was part of an epidemiologic study of workers in 37 autobody shops in Connecticut. This article describes workplaces, tasks, and controls, and outlines the frequency, duration, and intensity of isocyanate exposures. Personal air samples taken outside of respirators had median concentrations of 66.5 microg NCO/m3 for primer, 134.4 microg (NCO)/m3 for sealer, and 358.5 microg NCO/m3 for clearcoat. Forty-eight percent of primer, 66% of sealer, and 92% of clearcoat samples exceeded the United Kingdom Health and Safety Executive guideline for isocyanate, though none exceeded the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit for monomer. Nonisocyanate-containing primers and sealers are used in more than half the shops, but nonisocyanate clearcoats are rare. Eighty-two percent of personal samples taken within a spray booth exceeded the U.K. guideline: 81% of those in downdraft spray booths, 74% in semidowndraft booths, and 92% in crossdraft booths. Only 8% of shops reported that spraying is done exclusively in spray booths. All painters wore some type of respirator. In 30% of shops, painters used supplied air respirators; the rest relied on half face organic vapor cartridge respirators with N95 overspray pads. All shops provided some type of gloves, usually latex, not recommended for isocyanate protection. Despite improvements in autobody shop materials, practices, and controls, there are still opportunities for substantial exposures to isocyanates.

Air Pollution, Indoor↗

Truncating the dose range for methacholine challenge tests: three occupational studies.

The methacholine challenge test protocol was assessed in the reanalysis of three occupational studies. We evaluated the impact of truncating the range of methacholine on responsiveness, as defined by slope and PC(20). In original analysis, reactivity was similar for apprentices and auto body shop workers, whereas boilermakers were more responsive. Truncating high concentrations did not change the classification of subjects with PC(20) <8 or 16 in any population. However, when responsiveness was measured by slope, the mean responsiveness increased, from -7.9 to -15.3 for apprentices and -7.2 to -10.0 for auto-body shop workers. Results support the American Thoracic Society's recommended maximum of 16 mg/ml and provide evidence that extending the dose range beyond that does not increase sensitivity, whereas stopping before 16 may exaggerate response. Furthermore, to ensure validity, neither slope nor PC(20) should be extrapolated beyond data.

Adult↗

Urinary hexane diamine to assess respiratory exposure to hexamethylene diisocyanate aerosol: a human inhalation study.

The use of urinary hexane diamine (HDA) as a biomarker to assess human respiratory exposure to hexamethylene diisocyanate (HDI) aerosol was evaluated. Twenty-three auto body shop workers were exposed to HDI biuret aerosol for two hours using a closed exposure apparatus. HDI exposures were quantified using both a direct-reading instrument and a treated-filter method. Urine samples collected at baseline, immediately post exposure, and every four to five hours for up to 20 hours were analyzed for HDA using gas chromatography and mass spectrometry. Mean urinary HDA (microg/g creatinine) sharply increased from the baseline value of 0.7 to 18.1 immediately post exposure and decreased rapidly to 4.7, 1.9 and 1.1, respectively, at 4, 9, and 18 hours post exposure. Considerable individual variability was found. Urinary HDA can assess acute respiratory exposure to HDI aerosol, but may have limited use as a biomarker of exposure in the workplace.

Adolescent↗