Adrenal lesions: attenuation measurement differences between CT scanners.

PURPOSE: To retrospectively compare unenhanced computed tomographic scans of the same adrenal lesion obtained with two different manufacturers' multidetector scanners to assess whether there are differences in attenuation measurements. MATERIALS AND METHODS: The study was approved by the local ethical committee, which waived patient consent, and was conducted in compliance with HIPAA. Electronic searching revealed patients with adrenal nodules scanned with both a Siemens 16-detector row scanner and one of eight GE Medical Systems multi-detector row scanners between January 2000 and September 2004 without the use of intravenous contrast material. Lesions were characterized by using histologic findings, fat content, or size stability. Size stability for 6 months was required unless both scans were obtained within 21 days of each other. Two radiologists independently measured lesion attenuation for regression analysis. Lesions considered benign (< or = 10 HU) on one scan and indeterminate (> 10 HU) on the other were separately analyzed, and technical parameters of scanning were compared. RESULTS: There were 47 patients (27 men, 20 women; age range, 40-86 years; mean age, 64 years) with four metastases, 42 adenomas, and one myelolipoma (long-axis length, 10-85 mm; mean, 24 mm). GE scans were obtained with four-detector row scanners (n = 32), an eight-detector row scanner (n = 2), and 16-detector row scanners (n = 13). Correlation between the two readers was 0.99 for both Siemens and GE scan attenuation measurements. The slope of regression lines for both readers plotting GE attenuation (y-axis) against Siemens attenuation (x-axis) was less than 1, which indicated a slight but statistically significant tendency for GE scans to have lower attenuations than do Siemens scans. For both readers, there were more lesions indeterminate (> 10 HU) on Siemens scans but benign (< or = 10 HU) on GE scans than the reverse (McNemar test, P < .02 for reader 1, not significant for reader 2). Average Siemens and GE scan technical parameters were similar. CONCLUSION: There are only slight differences in attenuation of adrenal nodules measured on scans obtained with different scanners.

Adrenal Gland Neoplasms↗

Evaluation of living renal donors: accuracy of three-dimensional 16-section CT.

PURPOSE: To retrospectively assess the sensitivity and specificity of three-dimensional (3D) 16-section computed tomography (CT) in the evaluation of vessels, pelvicalyceal system, and ureters in living renal donors, with surgical findings as the reference standard. MATERIALS AND METHODS: This was a HIPAA-compliant study. Institutional review board approval was obtained for the review of subjects' medical records and data analysis, with waiver of informed consent. Forty-six renal donors (18 men, 28 women; mean age, 42 years) were examined with 16-section CT. Two blinded reviewers independently studied renal vascular and urographic anatomy of each donor CT scans by fist using 3D images alone, then transverse images alone, and finally transverse and 3D data set. Image quality, degree of diagnostic confidence, and time used for review were recorded. Sensitivity and specificity were calculated. RESULTS: For 3D images, transverse images, and transverse in conjunction with 3D data sets, the respective sensitivity and specificity of CT in evaluation of accessory arteries by reviewer 1 were 100% and 100%, 89% and 100%, and 100% and 100%, and those by reviewer 2 were 89% and 97%, 89% and 100%, and 89% and 100%; the respective sensitivity and specificity in evaluation of venous anomalies by reviewer 1 were 100% and 98%, 100% and 98%, and 100% and 98%, and those by reviewer 2 were 100% and 98%, 100% and 95%, and 100% and 98%. For focused comprehensive assessment of renal donors with 3D scans alone, a reviewer on average (average of reviewers 1 and 2) used 2.4 minutes per scan, demonstrated full confidence in 93%, and rated the quality as excellent in 76%. CONCLUSION: For focused assessment of renal vascular and urographic anatomy, review of 3D data set alone provides high sensitivity and specificity with regard to findings seen at surgery.

Adult↗

Adrenal lesions: characterization with fused PET/CT image in patients with proved or suspected malignancy--initial experience.

PURPOSE: To retrospectively evaluate the accuracy of the fused positron emission tomographic (PET)/computed tomographic (CT) image for characterization of adrenal lesions in patients who have proved malignancy or are suspected of having malignancy. MATERIALS AND METHODS: Institutional review board approval was received for this retrospective HIPAA-compliant study, and informed consent was waived. Forty-one adrenal lesions in 38 patients (21 men, 17 women; mean age, 66 years; range, 37-86 years) were evaluated with PET/CT. Of the 41 lesions, nine were assumed to be malignant with documentation of enlargement (n = 8) or reduction in size in response to treatment (n = 1), and 32 were assumed to be benign with documentation of stability for 6 months (n = 31) or with confirmation with biopsy results (n = 1). The PET examination findings were positive when adrenal lesion maximum standardized uptake values (SUVs) exceeded hepatic maximum SUVs. CT contrast medium washout analysis was used to further characterize two lesions with PET findings positive for malignancy. The t test was used to assess significant (P < .05) differences between fluorine 18 fluorodeoxyglucose (FDG) uptake of benign lesions and that of malignant lesions. RESULTS: At PET/CT, findings for all malignant lesions were positive (mean adrenal lesion-liver activity ratio, 4.04; range, 1.53-17.08). Of the 32 benign lesions, most (30 of 32) had activity less than that of the liver (mean ratio, 0.66; range, 0.22-0.94). PET/CT demonstrated sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 100%, 93.8%, 81.8%, 100%, and 95.1%, respectively. Incorporating contrast material-enhanced CT with delayed imaging increased specificity to 100% because two lesions with PET findings positive for malignancy were characterized as benign. There was a significant difference between maximum SUV (P < .05) and the ratio of adrenal lesion-liver FDG activity (P < .001) in benign versus malignant adrenal lesions. CONCLUSION: PET/CT provides a powerful combination of functional and attenuation information for adrenal lesion characterization. All malignant lesions were detected at PET/CT, with no false-negative results.

Adrenal Gland Neoplasms↗

Adrenocortical carcinoma: contrast washout characteristics on CT.

OBJECTIVE: The purpose of this study was to characterize pathologically proven adrenocortical carcinoma by examination of washout attenuation characteristics on contrast-enhanced CT images. CONCLUSION: Adrenocortical carcinoma has relative contrast retention on delayed contrast-enhanced CT. All tumors in this series had a relative percentage washout less than 40%, a finding consistent with malignant disease.

Adrenal Cortex Neoplasms↗

Distinguishing benign from malignant adrenal masses: multi-detector row CT protocol with 10-minute delay.

PURPOSE: To retrospectively evaluate the accuracy of precontrast attenuation, relative percentage washout (RPW), and absolute percentage washout (APW) in distinguishing benign from malignant adrenal masses at multi-detector row computed tomography (CT). MATERIALS AND METHODS: This HIPAA-compliant retrospective study had institutional review board approval; the need for informed consent was waived. One hundred twenty-two adrenal masses were evaluated in 99 patients (51 men, 48 women; age range, 37-86 years) who had undergone CT performed according to the study protocol and who either were given a pathologic diagnosis or underwent follow-up imaging. Unenhanced images were obtained before administration of 120 mL of an intravenous contrast agent with a 75-second scan delay. Delayed images were obtained after 10 minutes. RPW and APW were computed. Receiver operating characteristic (ROC) analysis was performed to compare mean attenuation and both RPW and APW. Analysis was first performed with the exclusion of pheochromocytomas, myelolipomas, and cysts. Precontrast attenuation criteria specific for benignity or malignancy were determined, and ROC analysis of results for the entire nonpheochromocytoma group was then performed. RESULTS: By using an RPW of 37.5% and excluding cysts and myelolipomas, all malignant lesions were detected with a sensitivity of 100% (17 of 17 lesions) and a specificity of 95% (90 of 95 lesions). Area under the binomial ROC curve (A(z)) values were 0.912, 0.985, and 0.892 for precontrast attenuation, RPW, and APW, respectively. Precontrast attenuation of less than 0 or more than 43 HU indicated benign and malignant entities, respectively. Incorporation of these criteria into the APW analysis yielded a sensitivity of 100% (17 of 17 lesions) and a specificity of 98% (93 of 95 lesions) for a threshold washout value of 52.0%. This attenuation-corrected APW generated the greatest A(z) value (ie, 0.988). Combining all the information available from the protocol yielded a sensitivity of 100% (17 of 17 lesions) and a specificity of 98% (98 of 100 lesions) for differentiating benign from malignant masses. CONCLUSION: Precontrast attenuation of less than 0 HU supercedes the washout profile in the evaluation of an individual adrenal mass. Noncalcified, nonhemorrhagic adrenal lesions with precontrast attenuation of more than 43 HU should be considered suspicious for malignancy.

Adrenal Gland Diseases↗

Detection of urinary tract stones at low-radiation-dose CT with z-axis automatic tube current modulation: phantom and clinical studies.

PURPOSE: To evaluate depiction of urinary tract calculi at computed tomography (CT) with a z-axis modulation technique at various noise indexes to reduce radiation dose and preserve image quality. MATERIALS AND METHODS: Sixteen radiopaque kidney stones (2.5-19.2 mm in diameter) were embedded in the collecting systems of two bovine kidneys immersed in a water bath. A kidney phantom was made by placing the kidneys in an elliptical Plexiglas phantom (32 x 20 x 20 cm) filled with physiologic saline. The phantom was scanned at 16-detector row CT with a fixed tube current (300 mA) and z-axis modulation at noise indexes of 14, 20, 25, 35, and 50; remaining imaging parameters were held constant. Two abdominal radiologists reviewed images from most to least noisy. Images were evaluated for presence of stones and size, site, and attenuation value of each stone. Readers also graded conspicuity and margins of each stone on a five-point scale. In addition, follow-up studies of 22 patients (mean age, 46 years; range, 26-57 years; male-female ratio, 14:8) with kidney and ureteral stones who underwent CT with z-axis modulation (noise index, 14 and 20) were evaluated in the same manner. Statistical analysis was performed with the Student t test, Wilcoxon signed rank test, and kappa test of interobserver agreement. Institutional review board approval was obtained, and informed consent was not needed. RESULTS: In the phantom study, all 16 stones were identified on images obtained with a fixed tube current and z-axis modulation at noise indexes of 14, 20, and 25 (with a reduction in radiation dose of up to 77% compared with that of fixed tube current scanning). Three stones (<5 mm) were not visualized with z-axis modulation at noise indexes of 35 and 50. No significant difference was shown for conspicuity of kidney stones in 22 patients who underwent CT with z-axis modulation (with a 43%-66% reduction in radiation dose) when compared with results of previous fixed tube current studies (P > .05). CONCLUSION: Kidney stones (< or =2.5 mm) can be adequately depicted with the z-axis modulation technique, with a 56%-77% reduction in radiation dose. In patients with urinary tract stones, the technique results in a 43%-66% reduction in radiation dose at noise indexes of 14 and 20 without compromising stone depiction.

Adult↗

Metallic prosthesis: technique to avoid increase in CT radiation dose with automatic tube current modulation in a phantom and patients.

The institutional review board approved this Health Insurance Portability and Accountability Act-compliant study protocol, with waiver of informed consent. The purpose of the study was to retrospectively evaluate the combined automatic tube current modulation technique in patients with orthopedic metallic prostheses. Five hundred abdominal-pelvic computed tomographic (CT) studies performed with combined modulation technique were reviewed to identify nine patients with metallic prostheses (mean age, 66 years; range, 35-86 years; male-female ratio, 5:4). On the basis of age and transverse abdominal images, these patients were matched with nine others with no metallic prostheses (mean age, 56 years; range, 36-72 years; male-female ratio, 4:5) who were control patients. Images were graded for extent and severity of streak artifacts (grade 1, streak artifact present but not substantially compromising evaluation of adjacent structures; grade 2, streak artifact present and slightly compromising evaluation of adjacent structures; and grade 3, streak artifact present and severely compromising evaluation of adjacent structures). Student t test was performed for statistical analysis. There was no difference in mean effective tube current-time product between study and control patients (P > .49). With automatic tube current modulation, an increase in CT dose caused by metallic prostheses can be successfully avoided.

Adult↗

CT images of abdomen and pelvis: effect of nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics.

The purpose of this study was to retrospectively assess the effect of a postprocessing nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics in abdominal and pelvic computed tomographic (CT) images. Institutional review board approved the HIPAA-compliant study protocol; informed consent was waived. Abdominal and pelvic CT images (40 patients; male-female ratio, 20:20; age range, 28-86 years) at 5-mm (n = 20) and 2-mm (n = 20) section thicknesses were postprocessed with the algorithm at three noise reduction levels. Image noise at the level of porta hepatis and acetabulum was evaluated with a five-point scale (1, no or minimal noise; 5, unacceptable noise), and presence and number of lesions and conspicuity were assessed. Statistical analysis was performed (Wilcoxon signed rank test, analysis of variance). Significant noise reduction was noted at all three levels with the algorithm (P < .05). Reduction in image contrast was noted with only one noise reduction level (P < .0001). The algorithm improves image noise without affecting lesion conspicuity and detection on low-dose abdominal and pelvic CT images.

Adult↗

Do metallic endoprostheses increase radiation dose associated with automatic tube-current modulation in abdominal-pelvic MDCT? A phantom and patient study.

OBJECTIVE: Our objective was to assess the effect of orthopedic metallic prostheses on radiation dose associated with MDCT using z-axis automatic tube-current modulation and a fixed tube current in a phantom and patient study. CONCLUSION: Z-modulation is associated with a 34.1% increase in the mean tube current-time product and no change in the extent of streak artifacts in patients with a metallic prosthesis, compared with patients without a prosthesis. However, compared with the fixed-tube-current technique, z-modulation is associated with a 28.9% decrease in the mean tube current-time product.

Adult↗

Strategies for CT radiation dose optimization.

Recent technologic advances have markedly enhanced the clinical applications of computed tomography (CT). While the benefits of CT exceed the harmful effects of radiation exposure in patients, increasing radiation doses to the population have raised a compelling case for reduction of radiation exposure from CT. Strategies for radiation dose reduction are difficult to devise, however, because of a lack of guidelines regarding CT examination and scanning techniques. Various methods and strategies based on individual patient attributes and CT technology have been explored for dose optimization. It is the purpose of this review article to outline basic principles of CT radiation exposure and emphasize the need for CT radiation dose optimization based on modification of scanning parameters and application of recent technologic innovations.

Adult↗

Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters.

PURPOSE: To assess the effect of noise reduction filters on detection and characterization of lesions on low-radiation-dose abdominal computed tomographic (CT) images. MATERIALS AND METHODS: Low-dose CT images of abdominal lesions in 19 consecutive patients (11 women, eight men; age range, 32-78 years) were obtained at reduced tube currents (120-144 mAs). These baseline low-dose CT images were postprocessed with six noise reduction filters; the resulting postprocessed images were then randomly assorted with baseline images. Three radiologists performed independent evaluation of randomized images for presence, number, margins, attenuation, conspicuity, calcification, and enhancement of lesions, as well as image noise. Side-by-side comparison of baseline images with postprocessed images was performed by using a five-point scale for assessing lesion conspicuity and margins, image noise, beam hardening, and diagnostic acceptability. Quantitative noise and contrast-to-noise ratio were obtained for all liver lesions. Statistical analysis was performed by using the Wilcoxon signed rank test, Student t test, and kappa test of agreement. RESULTS: Significant reduction of noise was observed in images postprocessed with filter F compared with the noise in baseline nonfiltered images (P =.004). Although the number of lesions seen on baseline images and that seen on postprocessed images were identical, lesions were less conspicuous on postprocessed images than on baseline images. A decrease in quantitative image noise and contrast-to-noise ratio for liver lesions was noted with all noise reduction filters. There was good interobserver agreement (kappa = 0.7). CONCLUSION: Although the use of currently available noise reduction filters improves image noise and ameliorates beam-hardening artifacts at low-dose CT, such filters are limited by a compromise in lesion conspicuity and appearance in comparison with lesion conspicuity and appearance on baseline low-dose CT images.

Adult↗

Pheochromocytoma: an imaging chameleon.

Pheochromocytomas are rare catecholamine-secreting tumors with many clinical and imaging manifestations. They may produce overwhelming cardiovascular crises if the diagnosis is not made or if appropriate treatment is delayed. It is thus important to recognize both their characteristic and atypical imaging appearances. Pheochromocytomas are encountered, sometimes unexpectedly, across a range of imaging modalities. They are characteristically solid, hypervascular masses with high signal intensity on T2-weighted magnetic resonance (MR) images. A wide spectrum of imaging appearances is seen, however, and pheochromocytomas may mimic other adrenal lesions, both benign and malignant. They may be dark on T2-weighted MR images, in contrast to their more classic bright T2-weighted appearance. Other atypical features include fatty, hemorrhagic, cystic, and calcific changes. Pheochromocytomas may contain sufficient fat to be mistaken for an adenoma at computed tomography (CT) or MR imaging. They may also demonstrate rapid contrast material washout and be mistaken for an adenoma owing to their deenhancement profile; however, their washout pattern can be inconsistent. The appearance of pheochromocytomas at radionuclide imaging is also unpredictable. These characteristics at CT, MR imaging, and scintigraphy pose diagnostic challenges, since they allow pheochromocytomas to mimic many other adrenal masses. Pheochromocytoma is an important, often clinically occult neoplasm with devastating consequences if overlooked. Radiologists must be aware of the various forms that pheochromocytomas can assume at imaging.

Adrenal Gland Neoplasms↗

Low-dose CT of the abdomen: evaluation of image improvement with use of noise reduction filters pilot study.

A prospective assessment of improvement in image quality at low-radiation-dose computed tomography (CT) of the abdomen by using noise reduction filters was performed. CT images acquired at standard and 50% reduced tube current were processed with six noise reduction filters and evaluated by three radiologists for image noise, sharpness, contrast, and overall image quality in terms of abdominal organ depiction. Quantitative image noise and contrast-to-noise ratio were measured. Baseline low-dose CT images were significantly worse than standard-dose CT images (P <.05). A statistically significant reduction of noise in low-dose images processed with three filters was noted. In conclusion, use of noise reduction filters decreased image noise at low-dose CT.

Aged↗