Comments on total platinum concentration and platinum oxidation states in body fluids, tissue, and explants from women exposed to silicone and saline breast implants by IC-ICPMS.

The paper by Lykissa and Maharaj (Lykissa, E. D.; Maharaj, S. V. M. Anal. Chem. 2006, 78, 2925-2933) comes to two main conclusions: platinum is found at elevated levels in women who have received breast implants, and the platinum is present in unusual oxidation states. The authors make clear their view that these are very surprising and disturbing results, both because of the quantity of platinum found and the association between higher oxidation states of platinum and toxicity of various types (sensitization-contact dermatitis, carcinogencity, among others). However, the conclusions arrived at by the authors are unsupported by the Experimental Section of the paper and the data that are reported there, and contravene the well-established chemistry of platinum.

Body Fluids↗

Platinum in silicone breast implants.

Silicone elastomers are widely used in implantable devices, including silicone breast implants. These rubbers are generally formed/cured using platinum-catalyzed hydrosilylation. The current scientific literature on the chemistry of platinum is reviewed, as it applies to the use of platinum catalysts for cure of silicone elastomers destined for use in silicone breast implants. These discussions serve as a basis to examine the recent literature describing release of platinum into tissues adjacent to silicone breast implants, the chemical nature of the platinum present in breast implants and the possible association between platinum and clinical outcomes.

Breast Implants↗

Elaboration of silica colloid/polymer hybrid support for oligonucleotide synthesis.

One way to increase the sensitivity of DNA diagnostic assays developed on microarrays is to improve the solid phase that allows the extraction of the target from a biological sample, before detection. Two parameters are influencing the performances of this capture step: (i) the specific surface area being offered for the capture and (ii) the number and the accessibility of oligonucleotide probes immobilized on the surface. In this context, we have developed an attractive approach which fulfills these two points. Our strategy was to elaborate a new material of high specific surface area, suitable to serve as support for both solid-phase oligonucleotide synthesis and in vitro diagnostic assay. This material has consisted of aggregates of colloidal amino-silica nanoparticles covalently linked by poly(ethylene oxide) (PEO) arms. The aggregation of amino-silica particles in the presence of reactive bis-isocyanate PEO was achieved in a controlled manner. The aggregate size and structure were examined by microscopy. The specific surface area of this material was measured by nitrogen adsorption technique. The composition of aggregate was studied by thermogravimetry and X-ray photoelectron spectroscopy. Then, this material has been successfully used as support for oligonucleotide synthesis of high yield and purity. The resulting system will be further evaluated in a diagnostic assay on a microarray.

Adsorption↗

Inhibitor screening using immobilized enzyme reactor chromatography/mass spectrometry.

We describe the coupling of capillary-scale monolithic enzyme reactor columns directly to a tandem mass spectrometer for screening of enzyme inhibitors. A two-channel nanoLC system is used to continuously infuse substrate or substrate/inhibitor mixtures through the column, allowing continuous variation of inhibitor concentration by simply altering the ratio of flow from the two pumps. In the absence of inhibitor, infusion of substrate leads to formation of product, and both substrate and product ions can be simultaneously monitored in a quantitative manner by MS/MS. The presence of inhibitor leads to a decrease in product and an increase in substrate concentration in the column eluent. Knowing the product/substrate ratio and the total analyte concentration (P + S), the concentration of product eluting, and hence the relative enzyme activity, can be determined. Both IC50 and KI values can then be obtained by direct MS detection of the effect of inhibitors on relative activity. Inhibitor screening is demonstrated using reusable, sol-gel derived, monolithic capillary columns containing adenosine deaminase, directly interfaced to ESI-MS/MS. On-column enzyme activity was assessed by monitoring inosine and adenosine elution. It is shown that the method can be used for automated screening of the effects of compound mixtures on ADA activity and to determine the KI value of the known inhibitor, erythro-9-(2-hydroxy-3-nonyl)adenine, even when the compound is present within a mixture.

Adenosine Deaminase↗

Capillary-scale monolithic immunoaffinity columns for immunoextraction with in-line laser-induced fluorescence detection.

A bimodal meso/macroporous monolithic silica capillary column containing an entrapped antibody was prepared by a biocompatible sol-gel process and used for nanoflow immunoaffinity chromatography and immunoextraction studies. Stationary phases were prepared by combining the protein-compatible silane precursor diglycerylsilane with an aqueous solution containing 10,000 Da poly(ethylene glycol) and the antibody. An analytical method was developed that was capable of determining both the dissociation constant and binding site content for the anti-fluorescein antibody within the stationary phase. The assay showed that while the antibody residing in macropores was easily removed, approximately 20% of initially loaded antibody remained active and accessible after several washes, consistent with the antibody being entrapped within the mesopores of the sol-gel matrix. The dissociation constants for fluorescein binding to the anti-fluorescein antibody were similar in solution and in the meso/macroporous silica, indicating that the entrapped antibody retained its native conformation within such a matrix. The mixture was loaded into a 250-microm-i.d. fused-silica capillary where the polymer phase separated from the silica followed by gelation of the silica. The capillary-scale immunoaffinity columns could be operated at low back pressure using a syringe pump and were capable of performing chromatographic separations that were dependent on the presence of the antibody within the stationary phase. Such columns could also be operated using in-line laser-induced fluorescence detection. The use of the capillary-scale monolithic columns for on-column immunoextraction and preconcentration is also demonstrated.

Journal Article↗

Capillary-scale frontal affinity chromatography/MALDI tandem mass spectrometry using protein-doped monolithic silica columns.

Frontal affinity chromatography (FAC) interfaced with electrospray mass spectrometry (ESI-MS) has been reported as a potential method for screening of compound mixtures against immobilized target proteins. However, the interfacing of bioaffinity columns to ESI-MS requires that the eluent that passes through the protein-loaded column have a relatively low ionic strength to produce a stable spray. Such low ionic strength solvents can cause serious problems with protein stability and may also affect binding constants and lead to high nonspecific binding to the column. Herein, we report on the interfacing of bioaffinity columns to matrix-assisted laser desorption/ionization (MALDI) MS/MS as a new platform for FAC/MS studies. Capillary columns containing a monolithic silica material with entrapped dihydrofolate reductase were used for frontal affinity chromatography of small-molecule mixtures. The output from the column was combined with a second stream containing alpha-cyano-hydoxycinnamic acid in methanol and was deposited using a nebulizer-assisted electrospray method onto a conventional MALDI plate that moved relative to the column via a computer-controlled x-y stage, creating a semipermanent record of the FAC run. The use of MALDI MS/MS allowed for buffers with significantly higher ionic strength to be used for FAC studies, which reduced nonspecific binding of ionic compounds and allowed for better retention of protein activity over multiple runs. Following deposition, MALDI analysis required only a fraction of the chromatographic run time, and the deposited track could be rerun multiple times to optimize ionization parameters and allow signal averaging to improve the signal-to-noise ratio. Furthermore, high levels of potential inhibitors could be detected via MALDI with limited ion suppression effects. Both MALDI- and ESI-based analysis showed similar retention of inhibitors present in compound mixtures when using identical ionic strength conditions. The results show that FAC/MALDI-MS should provide advantages over FAC/ESI-MS for high-throughput screening of compound mixtures.

Automation↗

Highly active, lipase silicone elastomers.

Lipase Candida rugosa was entrapped in silicone rubber via condensation-cure room temperature vulcanization of silanol-terminated poly(dimethylsiloxane) with tetraethyl orthosilicate as a crosslinker, to give a highly active silicone-enzyme elastomer. The effect on enzyme activity of addition of water and hydrophilic polymeric moieties based on poly(ethylene oxide) 2 was examined, as were crosslinker concentration, enzyme concentration, and elastomer thickness. It was demonstrated that lipase is most active in silicone elastomers and more active in silicone oils than simple hydrocarbons. Crosslink density in these elastomers was not an important factor in the reactivity of the rubber. However, the addition of hydrophilic species prior to elastomer formation decreased the efficiency both of the dispersion of the enzyme and the resulting activity of the elastomer. This effect could be moderated by prior exposure of the lipase to silicone oil. Thus, hydrophobic silicones play a protective/activating role for lipase.

Biocompatible Materials↗

Protein repellant silicone surfaces by covalent immobilization of poly(ethylene oxide).

Polydimethylsiloxane elastomers were surface modified with passivating polyethylene oxide (PEO) polymers of different molecular weights, both monofunctional and bifunctional. Following the introduction of Si-H groups on the surfaces by acid-catalyzed equilibration in the presence of polymethylhydrosiloxane, the PEO was linked by platinum-catalyzed hydrosilylation. ATR-FTIR, X-ray photoelectron spectroscopy (XPS) and water contact angle results confirmed that the PEO was successfully grafted to the silicone rubber. Atomic force microscopy and XPS suggested that surface coverage with PEO was very high on the modified surfaces but not complete. The protein-resistant properties of the PEO-modified surfaces were demonstrated by measuring the adsorption of fibrinogen from both buffer and plasma. Fibrinogen adsorption from buffer to the PEO-modified surfaces was reduced by more than 90% compared with controls.

Adhesiveness↗

Immobilization of heparin on a silicone surface through a heterobifunctional PEG spacer.

A novel method of immobilizing heparin on a silicone surface through a heterobifunctional PEG spacer was used yield well defined surfaces with highly active surface immobilized heparin and low non-specific protein adsorption. The heparin surface density achieved using this technique was 0.68 microg/cm2. Sessile drop water contact angles showed increased hydrophilicity of the silicone surface after PEG modification and a further decrease in the contact angles following the grafting of heparin. High specificity for ATIII with little fibrinogen adsorption was noted in plasma adsorption studies. This ATIII adsorption was mediated by the heparin layer, since surfaces modified with PEG only did not adsorb significant quantities of AT. The thrombin resistance of the heparin modified surfaces was demonstrably greater as measured by a chromogenic thrombin generation assay. The results suggest that the heterbifunctional PEG linker results in a high density of active heparin on the surfaces.

Adsorption↗

Surface properties of PEO-silicone composites: reducing protein adsorption.

Silicone-based polymers with reduced protein adsorption were successfully prepared by incorporating mono- or bifunctional poly(ethylene oxide) (PEO) derivatives, respectively, into PDMS during rubber formation using classic room temperature vulcanization chemistry. Characterization of the films by water contact-angle measurements and XPS showed that the PEO was present on the film surface, with greater amounts of PEO at the interface modified with monofunctional PEO. Scanning electron microscopy showed the PEO domains segregated into regular zigzag patterns on the PEO-modified surfaces. Significant reductions in the adsorption of fibrinogen, albumin and lysozyme were observed on both PEO-modified surfaces, although the monofunctional PEO surfaces performed much better in this regard. The reductions in protein adsorption were comparable for all three proteins on both surfaces, suggesting that molecular mass of the protein is not a significant factor in determining the magnitude of protein deposition. Western blot studies showed that the adsorption of proteins from plasma to the monofunctional PEO-modified surfaces was also significantly reduced and surprisingly selective, with very few bands noted relative to the control surfaces and those modified with bifunctional PEO.

Adsorption↗

Siloxane-supported organometallic compounds and their catalytic activities for the hydrosilylation of vinylsilanes and dienes.

Two different classes of silicone-modified ligands were prepared: nitrile derivatives, 4'-[3-(organosilyl)propoxy]biphenyl-4-carbonitrile R'3SiC3H6OC6H4C6H4CN (R'3Si- = a: Me3SiOSiMe2-, b: (Me(3)SiO)2SiMe-, c: Me3SiO(Me2SiO)3SiMe2-, d: Me3SiO(Me2SiO)25SiMe2-); and, pyridine derivatives, isonicotinic acid 2-methoxy-4-[3-(organosilyl)propyl]phenyl ester R'3SiC3H6Ph(O)MeOCOC5H4N . Compounds and were bound to Pd and Pt using ligand substitution reactions with organometallic precursors to give (R3SiC3H6OC6H4C6H4CN)2PdCl2, (R3SiC3H6OC6H4C6H4CN)2PtCl2 and (R3SiC3H6C6H3(OMe)OC(O)C5H4N)PtCl2(eta(2)-1-octene). The polydimethylsiloxane (PDMS)-supported Pt and Pd compounds and had excellent solubility in both organic solvents and polysiloxanes. All the Pt compounds exhibited good catalytic activity for hydrosilylation of vinylsilanes. The PDMS-supported Pd compound also was effective catalyst for hydrosilylation of a diene, isoprene, with 1,1,1,3,3-pentamethyldisiloxane MM(H) to produce the 1,4-adduct Me3SiOSiMe2CH2CH=CMeCH2-H as a major product.

Journal Article↗

Entrapment of Src protein tyrosine kinase in sugar-modified silica.

A novel sugar-modified silica has been used to entrap for the first time a protein tyrosine kinase (PTK). Silane precursors bearing covalently attached gluconamide moieties were used in combination with the biocompatible precursor diglycerylsilane (DGS) to generate sol-gel derived silica that was able to encapsulate highly active Src PTK and preserve the activity of the enzyme over multiple uses. The relative activity of the enzyme was assayed using a LANCE based fluorescence resonance energy transfer method involving time-gated detection of fluorescence from a europium labeled antiphosphotyrosine antibody and Cy5 labeled streptavidin upon mutual binding to biotinylated phosphopeptides. Using this detection method, with the antibody and streptavidin external to the sol-gel matrix, it was possible to detect the phosphorylation of peptides with molecular weights of up to 2300 Da using the entrapped enzyme in N-(3-triethoxysilylpropyl)gluconamide (GLTES) doped glasses. Src kinase-doped glasses, derived from precursors such as tetramethyl orthosilicate, tetraethyl orthosilicate, or DGS that did not contain GLTES, provided no detectable enzyme activity. The addition of 1 mM ATP to the GLTES/DGS sol before the encapsulation of the protein increased the activity of the enzyme in the resulting gel, likely through a ligand-based stabilization mechanism. The use of such a system for determination of PTK activity and inhibition is demonstrated, setting the stage for the development of chromatographic and microarray based methods for the screening of kinase inhibitors.

Fluorescence↗

Evaluating formation and growth mechanisms of silica particles using fluorescence anisotropy decay analysis.

At present, there is no direct experimental evidence that primary silica particles, which exist only transiently for a few seconds during the Stöber silica synthesis, can be stable in aqueous solutions. In the present work, we show that primary silica particles are formed spontaneously after the dissolution of diglycerylsilane (DGS) in aqueous solutions and remain stable for prolonged periods of time. By using time-resolved fluorescence anisotropy (TRFA), we demonstrate that this unique property of DGS is ascribed to the slow kinetics of silica particle growth in diluted sols at pH approximately 9.0. The anisotropy decay of the cationic dye rhodamine 6G (R6G), which strongly adsorbs to silica oligomers and nanoparticles in DGS sols, could be fit to three components: a fast (picosecond) scale component associated with free R6G, a slower (nanosecond) rotational component associated with R6G bound to primary silica particles, and a residual (nondecaying) anisotropy component associated with R6G that was bound to secondary or larger particles that were unable to rotate on the time scale of the R6G emission lifetime (4 ns). The data show that, under conditions where fast hydrolysis is obtained, the initial size of the nuclei depends on the silica concentration, with larger nuclei being present in more concentrated sols, while the rate of growth of primary particles depends on both silica concentration and solution pH. At low silica concentrations and high pHs, it was possible to observe the growth of stable, nonaggregating primary silica particles by a mechanism involving rapid nucleation followed by monomer addition. The presence of stable primary particles was confirmed by atomic force microscopy (AFM) imaging. At higher silica concentrations and lower pHs, there was an increase in the initial size of the nuclei formed, which subsequently grew to a larger radius (> 4.5 nm) or aggregated with time, and in such cases, nucleation and aggregation occurred simultaneously in the early stage of silica formation. The data clearly show the power of time-resolved fluorescence anisotropy decay measurements for probing the growth of silica colloids and show that this method is useful for elucidating the mechanism of particle formation and growth in situ.

Journal Article↗

Ultrasensitive ATP detection using firefly luciferase entrapped in sugar-modified sol-gel-derived silica.

Firefly luciferase (FL) was entrapped in sol-gel-derived silica containing precursors based on covalent linkage of d-gluconolactone or d-maltonolactone to (aminopropyl)triethoxysilane to form N-(3-triethoxysilylpropyl)gluconamide or N-(3-triethoxysilylpropyl)maltonamide. The enzyme was active and stable in this material and showed catalytic constants close to those in solution. As little as 20 amol ATP could be detected with the entrapped FL, and the entrapped enzyme could be used over several cycles.

Adenosine Triphosphate↗

Protein-doped monolithic silica columns for capillary liquid chromatography prepared by the sol-gel method: applications to frontal affinity chromatography.

The development of bioaffinity chromatography columns that are based on the entrapment of biomolecules within the pores of sol-gel-derived monolithic silica is reported. Monolithic nanoflow columns are formed by mixing the protein-compatible silica precursor diglycerylsilane with a buffered aqueous solution containing poly(ethylene oxide) (PEO, MW 10,000) and the protein of interest and then loading this mixture into a fused-silica capillary (150-250-microm i.d.). Spinodal decomposition of the PEO-doped sol into two distinct phases prior to the gelation of the silica results in a bimodal pore distribution that produces large macropores (>0.1 microm), to allow good flow of eluent with minimal back pressure, and mesopores (approximately 3-5-nm diameter) that retain a significant fraction of the entrapped protein. Addition of low levels of (3-aminopropyl)triethoxysilane is shown to minimize nonselective interactions of analytes with the column material, resulting in a column that is able to retain small molecules by virtue of their interaction with the entrapped biomolecules. Such columns are shown to be suitable for pressure-driven liquid chromatography and can be operated at relatively high flow rates (up to 500 microL x min(-1)) or with low back pressures (<100 psi) when used at flow rates of 5-10 microL x min(-1). The clinically relevant enzyme dihydrofolate reductase was entrapped within the bioaffinity columns and was used to screen mixtures of small molecules using frontal affinity chromatography with mass spectrometric detection. Inhibitors present in compound mixtures were retained via bioaffinity interactions, with the retention time being dependent on both the ligand concentration and the affinity of the ligand for the protein. The results suggest that such columns may find use in high-throughput screening of compound mixtures.

Buffers↗

Fluorescence anisotropy in studies of solute interactions with covalently modified colloidal silica nanoparticles.

Time-resolved anisotropy decays of a fluorescent cationic solute, rhodamine 6G (R6G), in Ludox sols were measured to characterize the extent of the ionic binding of the probe to silica particles after modification of the surface with neutral or cationic silane coupling agents. The anisotropy decays provided direct evidence for distribution of the dye between the aqueous solution (picosecond decay component) and silica particles (nanosecond decay component and residual anisotropy component, which were attributed to the wobbling motion of dye on the silica surface and to the ionically bound probe, respectively). The dye was strongly adsorbed to unmodified silica nanoparticles, to the extent that less than 1% of the dye was present in the surrounding aqueous solution. Significant decreases in the degree of probe adsorption were obtained upon covalent modification of the silica with neutral or cationic silanes, with up to 80% of the probe being present in the aqueous solution in cases where the surface was coated with (3-aminopropyl)triethoxysilane. The addition of such agents also altered the fractional distribution between the nanosecond decay component and the residual anisotropy component in favor of the nanosecond component, indicative of weaker interactions between the dye and the modified surface (i.e., more wobbling motion). The data clearly show the power of time-resolved fluorescence anisotropy decay measurements for probing the modification of silica surfaces and should prove useful in characterization of new chromatographic stationary phases.

Adsorption↗