PubMed Health⌕ Search

Biomedical subjects

Michael A Patak

Publications and source records attributed to Michael A Patak.

4 recordsLinked to original sources

Gradient-enhanced volume rendering: an image processing strategy to facilitate whole small bowel imaging with MRI.

MRI of the small bowel with positive contrast from orally administered contrast agent is a promising non-invasive imaging method. The aim of our study was to introduce small bowel MRI in a display format that clinicians are accustomed to and that maximizes the amount of information visualized on a single image. Twelve healthy volunteers, median age 32 years (range 18-49 years) participated in the study. A mixture of 20 ml Gd-DOTA (Dotarem), 0.8 g/kg body weight psyllium fibre (Metamucil) and 1.2 l water were sequentially administered over a period of 4 h. Imaging was performed on a 1.5 T unit (Philips Gyroscan, Intera). Fat-saturated, 3D, gradient echo imaging was performed while the patient was in apnea (30 s). Bowel motion was reduced with 40 mg intravenously administered scopolamine (Buscopan). A 3D, gradient-enhanced, volume rendering technique was applied to the 3D data sets. Standard projections [left anterior oblique (LAO), right anterior oblique (RAO), supine and prone] resembling conventional enteroclysis were successfully generated within fewer than 10 min processing time. Reconstructions were reproducible and provided an entire overview of the small bowel. In addition thin-slab volume rendering allowed an overlap-free display of individual structures. Positive contrast from orally administered contrast agent, combined with a gradient enhanced volume rendering method, allows the reconstruction of the small bowel in a pattern resembling conventional double-contrast enteroclysis. Segmental display without overlay is possible.

Adolescent↗

Small bowel motility assessment with magnetic resonance imaging.

PURPOSE: To assess primarily the feasibility of magnetic resonance imaging (MRI) as a tool to monitor small bowel peristaltic motion and secondarily to validate this technique by demonstrating drug-induced motility changes. MATERIALS AND METHODS: After a standardized oral preparation of Ispaghula husk (Metamucil) and meglumine gadoterate (Gd-DOTA; Dotarem), 10 volunteers underwent dynamic MRI using a two-dimensional turbofast field echo (TFE) sequence with a slice repetition time of 500 msec. Intraluminal cross-sectional caliber changes over time were assessed allowing quantification of the peristaltic frequencies and amplitudes of the small gut on various regions of interest. Pharmacologically induced alterations of the peristaltic motion after spasmolytics and gastrokinetic motion enhancers were investigated. RESULTS: Small bowel diameter measurement resulted in a peristalsis of 10.96 (SD = +/-2.51) waves per minute, oscillating regularly with mean amplitudes of 6.65 mm (SD = +/-1.15 mm). Peristaltic frequency in normal individuals is consistent with that observed with other techniques. Intravenous administration of scopolamine butylbromide (= hyoscine butylbromide/Buscopan) resulted in small bowel paralysis within 21.3 seconds (SD = +/-2.8 seconds). Prokinetic effect of intravenous metoclopramide (Paspertin) after Buscopan paralysis was tested in one volunteer, characterized by a slow recovery of peristalsis, which propagated from the proximal to the distal segments and enhanced contraction amplitudes. CONCLUSION: Dynamic MRI allows observing and quantifying small bowel peristalsis, characterizing motion patterns, and monitoring the effects of interfering factors such as drugs.

Adolescent↗

Multidetector row CT of the small bowel.

Multidetector row CT (MDCT) has become an imaging technique of choice to study routinely the small bowel. Thin collimation and fast scanning allow coverage of the entire abdomen within a single suspended respiration phase allowing the use of multiple enhancement phases after intravenous contrast administration. MDCT of the small bowel can identify and stage most of the common diseases of the small bowel. MDCT is changing the paradigm for diagnosing small bowel disease by becoming the first diagnostic line for almost all small bowel diseases. MDCT has the needed sensitivity and specificity, the availability, and the safety for a front-line diagnostic method.

Contrast Media↗

High-resolution magnetic resonance angiography of hands with timed arterial compression (tac-MRA).

Timed arterial compression (tac) of blood flow can be achieved by inflation of a blood-pressure cuff. We postulated that this technique might improve contrast-enhanced magnetic resonance angiography (MRA) of the arteries of the hands. We studied eight volunteers and six patients with occlusive arterial disease of the hands with standard MRA and tac-MRA. Compared with standard MRA, acquisition time was extended with the blood-pressure cuff by a factor of four, leading to quadrupled image resolution (512x1024). Furthermore, flow-related artifacts were not seen. Tac-MRA permits visualisation of the peripheral arterial system in finer detail than that achieved with standard MRA.

Adult↗