3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent.

The purpose of this study was to assess the feasibility of contrast-enhanced 3D perfusion MRI and MR angiography (MRA) of pulmonary embolism (PE) in pigs using a single injection of the blood pool contrast Gadomer. PE was induced in five domestic pigs by injection of autologous blood thrombi. Contrast-enhanced first-pass 3D perfusion MRI (TE/TR/FA: 1.0 ms/2.2 ms/40 degrees; voxel size: 1.3 x 2.5 x 4.0 mm3; TA: 1.8 s per data set) and high-resolution 3D MRA (TE/TR/FA: 1.4 ms/3.4 ms/40 degrees; voxel size: 0.8 x 1.0 x 1.6 mm3) was performed during and after a single injection of 0.1 mmol/kg body weight of Gadomer. Image data were compared to pre-embolism Gd-DTPA-enhanced MRI and post-embolism thin-section multislice CT (n = 2). SNR measurements were performed in the pulmonary arteries and lung. One animal died after induction of PE. In all other animals, perfusion MRI and MRA could be acquired after a single injection of Gadomer. At perfusion MRI, PE could be detected by typical wedge-shaped perfusion defects. While the visualization of central PE at MRA correlated well with the CT, peripheral PE were only visualized by CT. Gadomer achieved a higher peak SNR of the lungs compared to Gd-DTPA (21 +/- 8 vs. 13 +/- 3). Contrast-enhanced 3D perfusion MRI and MRA of PE can be combined using a single injection of the blood pool contrast agent Gadomer.

Animals↗

Time-resolved contrast-enhanced three-dimensional pulmonary MR-angiography: 1.0 M gadobutrol vs. 0.5 M gadopentetate dimeglumine.

PURPOSE: To compare contrast characteristics and image quality of 1.0 M gadobutrol with 0.5 M Gd-DTPA for time-resolved three-dimensional pulmonary magnetic resonance angiography (MRA). MATERIALS AND METHODS: Thirty-one patients and five healthy volunteers were examined with a contrast-enhanced time-resolved pulmonary MRA protocol (fast low-angle shot [FLASH] three-dimensional, TR/TE = 2.2/1.0 msec, flip angle: 25 degrees, scan time per three-dimensional data set = 5.6 seconds). Patients were randomized to receive either 0.1 mmol/kg body weight (bw) or 0.2 mmol/kg bw gadobutrol, or 0.2 mmol/kg bw Gd-DTPA. Volunteers were examined three times, twice with 0.2 mmol/kg bw gadobutrol using two different flip angles and once with 0.2 mmol/kg bw Gd-DTPA. All contrast injections were performed at a rate of 5 mL/second. Image analysis included signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements in lung arteries and veins, as well as a subjective analysis of image quality. RESULTS: In patients, significantly higher SNR and CNR were observed with Gd-DTPA compared to both doses of gadobutrol (SNR: 35-42 vs.17-25; CNR 33-39 vs. 16-23; P < or = 0.05). No relevant differences were observed between 0.1 mmol/kg bw and 0.2 mmol/kg bw gadobutrol. In volunteers, gadobutrol and Gd-DTPA achieved similar SNR and CNR. A significantly higher SNR and CNR was observed for gadobutrol-enhanced MRA with an increased flip angle of 40 degrees. Image quality was rated equal for both contrast agents. CONCLUSION: No relevant advantages of 1.0 M gadobutrol over 0.5 M Gd-DTPA were observed for time-resolved pulmonary MRA in this study. Potential explanations are T2/T2*-effects caused by the high intravascular concentration when using high injection rates.

Adult↗

MR-guided intravascular procedures: real-time parameter control and automated slice positioning with active tracking coils.

PURPOSE: To implement and optimize a real-time pulse sequence and user interface to perform intravascular interventions using active catheter tracking. MATERIALS AND METHODS: In magnetic resonance (MR)-guided interventions, small radio-frequency coils can be used to rapidly determine the device position (active tracking). In this work, active catheter tracking was combined with a dedicated real-time pulse sequence and user interface. The pulse sequence offered the imaging contrasts fast low angle shot (FLASH), true Fast imaging with steady state precession (TrueFISP), and projection MR digital subtraction angiography (MR-DSA), which could be selected by the radiologist from within the scanner room at any time during the intervention. Automatic slice positioning was added to the real-time pulse sequence so that the location of the tracking coils defined the image slice position and orientation. The technique was assessed in phantoms and animal experiments. RESULTS: At a reaction time of 24 msec and a frame rate of three images per second, the movement of an active intravascular catheter could be monitored in the aorta and the renal arteries of a pig. With interactive contrast and orientation changes, the renal vasculature could be assessed by a fully MR-guided catheterization in less than 10 minutes. CONCLUSION: With carefully designed active catheters, a dedicated user interface, and an optimized pulse sequence intravascular interventions can successfully be performed by a single operator from within the MR scanner room.

Animals↗

MR coil design for simultaneous tip tracking and curvature delineation of a catheter.

In active catheter tracking, small RF coils are attached to the catheter for localization. For interactive catheter steering at vessel branchings, it is necessary to visualize not only a single point near the catheter tip but also the entire shape and orientation of the catheter's distal end. Therefore, a 35-mm-long twisted-pair RF coil was added to a 5 French intravascular catheter with a single tip-tracking coil. With the use of small nonmagnetic electronic components at the catheter tip, and a special switching circuitry outside the catheter, the coil assembly could be operated in two different modes. During MRI, the tip-tracking coil was detuned so that the MR signal was received by the visualization coil only. During tracking, detuning was switched off and the MR signal was predominantly received by the more sensitive tracking coil. The catheter was used in combination with a MR pulse sequence with automatic slice positioning so that the current imaging slice was always placed at the position of the catheter tip. Phantom and animal experiments showed that the catheter tip is better visualized with the combined approach than with a tracking coil alone.

Animals↗

Semiquantitative fast flow velocity measurements using catheter coils with a limited sensitivity profile.

Flow measurements can be used to quantify blood flow during MR-guided intravascular interventional procedures. In this study, a fast flow measurement technique is proposed that quantifies flow velocities in the vicinity of a small RF coil attached to an intravascular catheter. Since the small RF coil receives signal from only a limited volume around the catheter, a spatially nonselective signal reception is employed. To enhance signal from flowing blood, and suppress unwanted signal contributions from static material, a slice-selective RF excitation is used. At a velocity sensitivity of 150 cm/s, a temporal resolution of 2 x TR = 10.2 ms can be achieved. The flow measurement is combined with an automatic slice positioning to facilitate measurements during interventional procedures. The influence of the catheter position in the blood vessel on the velocity measurement was analyzed in simulations. For blood vessels with laminar flow, the simulation showed a systematic deviation between catheter measurement and true flow between -15% and 80%. In four animal experiments, the catheter velocity measurement was compared with results from a conventional ECG-triggered 2D phase-contrast (PC) technique. The shapes of the velocity time curves in the abdominal aorta were nearly identical to the conventional measurements. A relative scaling factor of 0.69-1.19 was found between the catheter velocity measurement and the reference measurement, which could be partly explained by the simulation results.

Animals↗

Renal disease: value of functional magnetic resonance imaging with flow and perfusion measurements.

PURPOSE: To differentiate healthy kidneys from diseased kidneys, we propose a combined magnetic resonance (MR) examination that includes measurements of renal arterial blood flow and parenchymal perfusion. MATERIALS AND METHODS: A total of 130 kidneys (patients/healthy volunteers: 83/47) were examined using renal artery MR flow measurements and renal parenchymal perfusion measurements, as well as contrast-enhanced MR angiography. Cine phase-contrast-flow measurements were performed using an ECG-gated fast low angle shot pulse sequence; perfusion was measured with an arterial spin labeling flow-sensitive alternating inversion recovery technique. Contrast-enhanced MR angiography was performed with a fast 3D gradient echo sequence in a single breath hold. For evaluation, kidneys were divided into groups based on nephrologic diagnosis of the patient. Recursive partitioning and Wilcoxon rank-sum tests were used to separate the different groups. RESULTS: Significant differences in mean renal artery flow and parenchymal perfusion were found in kidneys with renal artery stenosis as well as parenchymal disease as compared with healthy kidneys. Using a classification tree derived from the recursive partitioning, a specificity of 99% and sensitivity of 69% with a positive/negative predictive value of 97%/84% was achieved for the separation of healthy kidneys from kidneys with vascular, parenchymal or combined disease. The overall accuracy was 88%. CONCLUSION: The combination of cine PC flow measurements and MR perfusion measurements offers a comprehensive assessment of both renovascular and renoparenchymal disease and provide a noninvasive approach to differentiate between these kidneys and normal kidneys.

Adult↗

Contrast-enhanced three-dimensional pulmonary perfusion magnetic resonance imaging: intraindividual comparison of 1.0 M gadobutrol and 0.5 M Gd-DTPA at three dose levels.

RATIONALE AND OBJECTIVES: To compare 1.0 M gadobutrol and 0.5 M Gd-DTPA for contrast-enhanced three-dimensional pulmonary perfusion magnetic resonance imaging (3D MRI). MATERIALS AND METHODS: Ten healthy volunteers (3 females; 7 males; median age, 27 years; age range, 18-31 years) were examined with contrast-enhanced dynamic 3D MRI with parallel acquisition technique (FLASH 3D; reconstruction algorithm: generalized autocalibrating partially parallel acquisitions; acceleration factor: 2; TE/TR/alpha: 0.8/1.9 milliseconds/40 degrees; FOV: 500 x 375 mm; matrix: 256 x 86; slab thickness: 180 mm; 36 partitions; voxel size: 4.4 x 2 x 5 mm; TA: 1.48 seconds). Twenty-five consecutive data sets were acquired after intravenous injection of 0.025, 0.05, and 0.1 mmol/kg body weight of gadobutrol and Gd-DTPA. Quantitative measurements of peak signal-to-noise ratios (SNR) of both lungs were performed independently by 3 readers. Bolus transit times through the lungs were assessed from signal intensity time curves. RESULTS: The peak SNR in the lungs was comparable between gadobutrol and Gd-DTPA at all dose levels (15.7 vs. 15.5 at 0.1 mmol/kg bw; 12.9 vs. 12.5 at 0.05 mmol/kg bw; 7.6 vs. 8.9 at 0.025 mmol/kg bw). A dose of 0.1 mmol/kg achieved the highest peak SNR compared with all other dose levels (P < 0.05). A higher peak SNR was observed in gravity dependent lung (P < 0.05). Despite different injection volumes, transit times of the contrast bolus did not differ between both agents. CONCLUSION: Higher concentrated gadolinium chelates offer no advantage over standard 0.5 M Gd-DTPA for contrast-enhanced 3D MRI of lung perfusion.

Adolescent↗

Renal embolization: feasibility of magnetic resonance-guidance using active catheter tracking and intraarterial magnetic resonance angiography.

RATIONALE AND OBJECTIVES: Magnetic resonance (MR)-guidance of endovascular interventions offers various advantages, including the absence of ionizing radiation, excellent soft tissue contrast, and multiplanar and functional imaging capabilities. The objective of this study was to assess the feasibility of MR-guided renal embolization using active catheter tracking with automatic slice positioning and intraarterial contrast-enhanced MR angiography (MRA). MATERIALS AND METHODS: MR-guided embolization of 16 kidneys was attempted in 15 pigs using real-time tracking of active 5-Fr. catheters. Embolization was monitored by selective intraarterial projection MRA. Intraarterial three-dimensional (3D) MRA was used for the assessment of embolization results. Additional pathologic correlation was available in 2 animals. The image quality of intraarterial 3D contrast-enhanced-MRA was rated by an independent radiologist who was not involved in the animal experiments. RESULTS: Active catheter tracking with automatic slice positioning allowed reliable catheter guidance and catheterization of the renal artery in all animals. Embolization was successful in all kidneys (11 left, 5 right), as verified by intraarterial 3D contrast-enhanced MRA (ce-MRA) and/or pathology. The image quality of intraarterial 3D ce-MRA was rated excellent in 10 animals, moderate in 4 animals, and poor in 1 animal. CONCLUSION: Renal embolization using active catheter tracking and intraarterial ce-MRA is feasible. Selective intraarterial ce-MRA allows the assessment of blood supply and organ perfusion before, during, and after therapeutic interventions, thereby complementing MR-guided endovascular interventions.

Animals↗

Asbestos-related pleural disease: value of dedicated magnetic resonance imaging techniques.

OBJECTIVES: We sought to compare respiratory-gated high-spatial resolution magnetic resonance imaging (MRI) and radial MRI with ultra-short echo times with computed tomography (CT) in the diagnosis of asbestos-related pleural disease. METHODS: Twenty-one patients with confirmed long-term asbestos exposure were examined with a CT and a 1.5-T MR unit. High-resolution respiratory-gated T2w turbo-spin-echo (TSE), breath-hold T1w TSE, and contrast-enhanced fat-suppressed breath-hold T1w TSE images with an inplane resolution of less than 1 mm were acquired. To visualize pleural plaques with a short T2* time, a pulse sequence with radial k-space-sampling was used (TE = 0.5 milliseconds) before and after administration of Gd-DTPA. CT and MR images were assessed by 4 readers for the number and calcification of plaques, extension of pleural fibrosis, extrapleural fat, detection of mesothelioma and its infiltration into adjacent tissues, and detection of pleural effusion. Observer agreement was studied with the use of kappa statistics. RESULTS: The MRI protocol allowed for differentiation between normal pleura and pleura with plaques. Interobserver agreement was comparable for MRI and CT in detecting pleural plaques (median kappa = 0.72 for MRI and 0.73 for CT) and significantly higher with CT than with MRI for detection of plaque calcification (median kappa 0.86 for CT and 0.72 for MRI; P = 0.03). Median sensitivity of MRI was 88% for detection of plaque calcification compared with CT. For assessment of pleural thickening, pleural effusion, and extrapleural fat, interobserver agreement with MRI was significantly higher than with CT (median kappa 0.71 and 0.23 for pleural thickening, 0.87 and 0.62 for pleural effusion, and 0.7 and 0.56 for extrapleural fat, respectively; P < 0.05). For detection of mesothelioma, median kappa was 0.63 for MRI and 0.58 for CT. CONCLUSION: High-resolution MR sequences and radial MRI achieve a comparable interobserver agreement in detecting pleural plaques and even a higher interobserver agreement in assessing pleural thickening, pleural effusion, and extrapleural fat when compared with CT.

Aged↗

Retroviral capsid determinants of Fv1 NB and NR tropism.

The specificity determinants for susceptibility to resistance by the Fv1 n and b alleles map to amino acid 110 of the murine leukemia virus CA protein. To study the interaction between Fv1 and CA, we examined changes in CA resulting in the loss of susceptibility to Fv1 resistance in naturally occurring NB- and NR-tropic viruses. A variety of amino acid changes affecting Fv1 tropism were identified, at CA positions 82, 92 to 95, 105, 114, and 117, and they all were mapped to the apparent exterior of virion-associated CA. These amino acids may form a binding surface for Fv1.

Alleles↗

Regional lung perfusion: assessment with partially parallel three-dimensional MR imaging.

PURPOSE: To evaluate partially parallel three-dimensional (3D) magnetic resonance (MR) imaging for assessment of regional lung perfusion in healthy volunteers and patients suspected of having lung cancer or metastasis. MATERIALS AND METHODS: Seven healthy volunteers and 20 patients suspected of having lung cancer or metastasis were examined with 3D gradient-echo MR imaging with partially parallel image acquisitions (fast low-angle shot 3D imaging; repetition time msec/echo time msec, 1.9/0.8; flip angle, 40 degrees; acceleration factor, two; number of reference k-space lines for calibration, 24; field of view, 500 x 440 mm; matrix, 256 x 123; slab thickness, 160 mm; number of partitions, 32; voxel size, 3.6 x 2.0 x 5.0 mm(3); acquisition time, 1.5 seconds) after administration of 0.1 mmol/kg of gadobenate dimeglumine. In volunteers, 3D MR perfusion data sets were assessed for topographic and temporal distribution of regional lung perfusion. Sensitivity, specificity, accuracy, and positive and negative predictive values for perfusion MR imaging for detecting perfusion abnormalities in patients were calculated, with conventional radionuclide perfusion scintigraphy as the standard of reference. Interobserver and intermodality agreement was determined by using kappa statistics. RESULTS: Topographic analysis of lung perfusion in volunteers revealed a significantly higher signal-to-noise ratio (SNR) of up to 327% in gravity-dependent lung areas. Temporal analysis similarly revealed much shorter lag time to peak enhancement in gravity-dependent lung areas. In patients, perfusion MR imaging achieved high sensitivity (88%-94%), specificity (100%), and accuracy (90%-95%) for detection of perfusion abnormalities. Interobserver agreement (kappa = 0.86) was very good and intermodality agreement (kappa = 0.69-0.83) was good to very good for detection of perfusion defects. A significant difference (P <.0001) in SNR was observed between normally perfused lung (14 +/- 7 [SD]) and perfusion defects (7 +/- 4) in patients. CONCLUSION: Partially parallel MR imaging with high spatial and temporal resolution allows assessment of regional lung perfusion and has high diagnostic accuracy for detecting perfusion abnormalities.

Adult↗

High-resolution three-dimensional MR angiography of rodent tumors: morphologic characterization of intratumoral vasculature.

PURPOSE: To evaluate high-resolution three-dimensional MR angiography (MRA) for the visualization and morphologic characterization of intratumoral vasculature. MATERIALS AND METHODS: Two subcutaneous rodent tumor models (human skin carcinoma HaCaT-ras-A-5RT3 grown in nude mice and rat prostate carcinoma R3327-AT1 grown in Copenhagen rats) were examined with a clinical 1.5 T MR-system. For MRA a dedicated high-resolution three-dimensional gradient echo pulse sequence with a voxel size of 166 x 206 x 320 microm(3) was performed after injection of Gadomer-17. The image analysis included a correlation of intratumoral vessels with histology. Signal intensity measurements were performed in the vena cava, the tumor underlying muscle, and in various regions of the tumor. Signal-to-noise-ratios (SNR) and contrast-to-noise-ratios (CNR) were calculated from this measurement. RESULTS: High-resolution MRA allowed a clear distinction of intratumoral blood vessels. The mouse tumor model tended to be strongly vascularized with several intratumoral blood vessels clearly displayed by MRA. When correlated with histology, these intratumoral blood vessels had a size in the range of 300 to 400 microm. In contrast, rat tumors had only sparse capillary intratumoral blood vessels that could only be demonstrated by histology. In both tumor models, dilated blood vessels were observed in the subcutaneous tissue near the tumor. In general, areas with a strong contrast enhancement correlated with viable, well vascularized tumor regions, whereas non-enhancing tumor areas correlated with tumor necrosis or hypoxic areas. CONCLUSION: High-resolution three-dimensional MRA allows the visualization of intratumoral vasculature in rodent models. With minimal hardware and software modifications, high-resolution MRA could be performed on a clinical 1.5 T MRI scanner. Morphologic characterization of intratumoral blood vessels could add important insights into the process of tumor angiogenesis.

Animals↗

Quantification of renal perfusion using an intravascular contrast agent (part 1): results in a canine model.

In this work absolute values of regional renal blood volume (rRBV) and flow (rRBF) are assessed by means of contrast-enhanced (CE) MRI using an intravascular superparamagnetic contrast agent. In an animal study, eight foxhounds underwent dynamic susceptibility-weighted MRI upon injection of contrast agent. Using principles of indicator dilution theory and deconvolution analysis, parametric images of rRBV, rRBF, and mean transit time (MTT) were computed. For comparison, whole-organ blood flow was determined invasively by means of an implanted flow probe, and the weight of the kidneys was evaluated postmortem. A mean rBV value of 28 ml/100 g was found in the renal cortex, with a corresponding mean rBF value of 524 ml/100 g/min and an average MTT of about 3.4 s. Although there was a systematic difference between the absolute blood flow values determined by MRI and the ultrasonic probe, a significant correlation (r(s) = 0.72, P < 0.05) was established. The influence of the arterial input function (AIF), T(1) relaxation effects, and repeated measurements on the precision of the perfusion quantitation is discussed.

Animals↗

Quantification of renal perfusion abnormalities using an intravascular contrast agent (part 2): results in animals and humans with renal artery stenosis.

The interrelation between the morphologic degree of renal artery stenosis and changes in parenchymal perfusion is assessed using an intravascular contrast agent. In seven adult foxhounds, different degrees of renal artery stenosis were created with an inflatable clamp implanted around the renal artery. Dynamic susceptibility-weighted gradient-echo imaging was used to measure signal-time curves in the renal artery and the renal parenchyma during administration of 1.5 mg/kg BW of an intravascular ultrasmall particle iron oxide (USPIO) contrast agent. From the dynamic series, regional renal blood volume (rRBV), regional renal blood flow (rRBF), and mean transit time (MTT) were calculated. The morphologic degree of stenosis was measured in the steady state using a high-resolution 3D contrast-enhanced (CE) MR angiography (MRA) sequence (voxel size = 0.7 x 0.7 x 1 mm(3)). Five patients with renoparenchymal damage due to long-standing renal artery stenosis were evaluated. In the animal stenosis model, cortical perfusion remained unchanged for degrees of renal artery stenosis up to 80%. With degrees of stenoses > 80%, cortical perfusion dropped to 151 +/- 54 ml/100 g of tissue per minute as compared to a baseline of 513 +/- 76 ml/100 g/min. In the patients, a substantial difference in the cortical perfusion of more than 200 +/- 40 ml/100 g/min between the normal and the ischemic kidneys was found. The results show that quantitative renal perfusion measurements in combination with 3D-CE-MRA allow the functional significance of a renal artery stenosis to be determined in a single MR exam. Differentiation between renovascular and renoparenchymal disease thus becomes feasible.

Angiography, Digital Subtraction↗

[Automatic slice tracking in interventional magnetic resonance imaging].

Magnetic resonance imaging (MRI) is ideally suited to monitor minimally invasive operations with catheters or needles, since it offers both a superior soft-tissue contrast and the possibility to perform functional tests. In the present study, small radio-frequency coils were attached to the instruments in order to localize the MR-invisible instruments. The implementation of active instrument tracking is described on the basis of the example of active catheter tracking. In this case, the current position information of the instrument is used to automatically position the MRI slice at the catheter location. In combination with a user interface, the interventional radiologist is offered the possibility to perform vascular interventions from within the MR scanner room. At image update rates of approximately 3 Hz, tracking and placement of catheters in vascular structures are possible with interactive switching of slice orientation and image contrast. In an animal model, the technique was successfully used to selectively visualize the abdominal vessels and their branches under MRI guidance.

Animals↗