Geometry of human ribs pertinent to orthopedic chest-wall reconstruction.

Orthopedic reconstruction of blunt chest trauma can aid restoration of pulmonary function to reduce the mortality associated with serial rib fractures and flail chest injuries. Contemporary chest wall reconstruction requires contouring of generic plates to the complex surface geometry of ribs. This study established a biometric foundation to generate specialized, anatomically contoured osteosynthesis hardware for rib fracture fixation. On human cadaveric ribs three through nine, the surface geometry pertinent to anatomically conforming osteosynthesis plates was characterized by quantifying the apparent rib curvature C(A), the longitudinal twist alpha(LT) along the diaphysis, and the unrolled curvature C(U). In addition, the rib cross-sectional geometry pertinent to intramedullary fixation strategies was characterized in terms of cross-section height, width, area, and cortex thickness. The rib surface exhibited a curvature C(A) ranging from 3.8 m(-1) in the anteromedial section of rib seven to 17.3 m(-1) in the posterior section of rib three. All ribs had in common a longitudinal twist alpha(LT), ranging from 41-60 degrees. The unrolled curvature C(U) decreased gradually from ribs three to five, and increased gradually with reversed orientation from rib six to nine. The cross-sectional area remained constant along the rib diaphysis. However, the medullary canal increased in size from 29.9 mm(2) posteriorly to 41.2 mm(2) in anterior rib segments. Results of this biometric rib characterization describe a novel strategy for intraoperative plate contouring and provide a foundation for the development of specialized rib osteosynthesis strategies.

Bone Plates↗

Malrotation in total knee arthroplasty: effect on tibial cortex strain captured by laser-based strain acquisition.

BACKGROUND: Malrotation of the tibial and femoral components has been recognized to be a clinical complication affecting the performance and durability of total knee arthroplasty. This study used a novel strain acquisition technique to determine the effect of tibio-femoral component malrotation on tibial torque and strain distribution of the proximal tibial cortex with a cemented fixed-bearing posterior-stabilized knee. METHODS: Using electronic speckle pattern interferometry, strain on the proximal tibia of human cadaveric knees was obtained in response to 1500N axial loading for neutrally aligned tibial and femoral components, and for 10 degrees internal and external malrotation between the tibial and femoral components. Local strain gage measurements were combined with full-field optical strain measurements to quantify effects on tibial cortex strain and strain distributions caused by the 10 degrees malrotations. In addition, tibial torque was measured for incremental degrees of tibio-femoral malrotation. FINDINGS: Tibio-femoral malrotations as small as 2 degrees caused tibial torque in excess of 4 Nm. At 10 degrees malrotation, tibial torque significantly increased to over 8 Nm (P<0.001) as compared to neutrally aligned components. Local strain gage results significantly increased from 500 muepsilon to 632 muepsilon compressive strain in response to 10 degrees external malrotation, and to 1000 muepsilon compressive strain in response to 10 degrees internal malrotation. Full-field optical strain reports yielded the highest strain of 2153 muepsilon for 10 degrees internal malrotation 30 mm below the joint line. INTERPRETATION: Laser-based strain measurement technology provides novel capabilities to capture cortex strain fields. The sensitivity of cortex strain and torsion to small amounts of tibio-femoral malrotation may explain factors contributing to aseptic implant loosening of the tibial component.

Aged↗

A mobile-bearing knee prosthesis can reduce strain at the proximal tibia.

Mobile and fixed-bearing knee prostheses are likely to generate distinct strain gradients in the proximal tibia. The resulting strain distribution in the proximal tibia governs bone remodeling and affects implant integration and stability. We determined the effects of fixed and mobile-bearing total knee prostheses on strain distribution at the proximal tibia. This mobile-bearing prosthesis was evaluated in cadaveric specimens under axial and torsional loading. Strain on the proximal tibial cortex was measured with rosette strain gages and an optical full-field strain acquisition system. Tibial torsion in response to combined axial and torsional loading was documented. There was no difference in cortex strain between the fixed and the mobile-bearing prostheses under 1.5 kN axial loading. Superimposing 10 degrees tibial internal rotation induced 22% less compressive strain in the mobile-bearing prosthesis compared with the fixed-bearing prosthesis. Under 10 degrees tibial external rotation, the mobile-bearing prosthesis induced 33% less compressive strain than the fixed-bearing prosthesis. Optically acquired strain fields showed peak compressive strain at the anteromedial aspect 30 mm below the joint line. The mobile-bearing prosthesis reduced torque in the proximal tibia during knee rotation by 68-73% compared with the fixed-bearing prosthesis. Our data suggest that the particular mobile-bearing prosthesis tested potentially reduces elevated strain levels in the proximal tibia.

Aged↗

Pediatric femoral fractures: a systematic review of 2422 cases.

BACKGROUND: The incidence of femoral fractures in children comprise 20 per 100,000 yearly in the United States and Europe. The treatment of femoral shaft fractures in the pediatric population remains controversial. The child's age often directs the management. Nonoperative treatment options include functional treatment for the very young, Pavlic harness, skin or skeletal traction, and spica casting. Operative treatment options include closed reduction and external fixation, open reduction and internal plate fixation, closed reduction and minimally invasive plate osteosynthesis (MIPO), and closed reduction and intramedullary nailing with either flexible or rigid nails. The effect of operative versus nonoperative treatment has been the focus of several comparative studies. OBJECTIVE: To determine the effect of different treatment options on the rate of union, malunion, leg-length discrepancy (LLD), complications, and outcome after femoral shaft fractures in children.

Adolescent↗

Knee stability after articulated external fixation.

BACKGROUND: Articulated external fixation has been proposed as a method to protect ligament reconstructions while allowing aggressive and early postoperative rehabilitation after knee dislocation. However, the ability of these fixators to protect and stabilize the knee joint has not been clearly determined. HYPOTHESIS: Articulated external fixation can reduce anteroposterior translation in the cruciate-deficient knee and reduce cruciate ligament strain in cases of intact or reconstructed ligaments. STUDY DESIGN: Controlled laboratory study. METHODS: Knee stability was assessed by 3 standard clinical stability tests (Lachman, anterior drawer, and posterior drawer) on 7 human cadaveric lower extremities. Instrumented forces of 100 N were applied to the tibia to measure cruciate ligament forces and tibiofemoral displacement in intact and cruciate-deficient specimens with and without articulated external fixation to determine the degree to which a fixator can protect cruciate ligaments and stabilize the knee. Articulated external fixation was applied using monolateral and bilateral fixators to comparatively analyze the effectiveness of each construct. Statistical analysis was performed using 2-tailed, paired Student t tests. RESULTS: Application of the monolateral articulated external fixator to specimens with intact ligaments significantly reduced cruciate ligament forces by 1.0 N (P = .011), 1.7 N (P = .046), and 1.4 N (P = .009) for Lachman, anterior drawer, and posterior drawer tests, respectively. In the cruciate ligament-deficient knees, the application of a monolateral fixator significantly reduced tibiofemoral translation by 49%, 70%, and 46% for Lachman, anterior drawer, and posterior drawer tests, respectively. No significant differences between the monolateral and bilateral fixator frames, in terms of ligament protection and joint stabilization, were observed. CONCLUSION AND CLINICAL RELEVANCE: Articulated external fixation of the knee can reduce stress in the cruciate ligaments after multiligament reconstructions and can decrease anteroposterior translation in the cruciate-deficient knee.

Aged↗

Lag screws for hip fracture fixation: Evaluation of migration resistance under simulated walking.

Previous mechanical studies concerning cut-out of lag screws for pertrochanteric hip fractures have relied on static or dynamic uniaxial loading regimens to induce construct failure by varus collapse and superior cut-out. However, the hip is loaded in a multiplanar, dynamic manner during normal gait. We designed a hip implant performance simulator (HIPS) system to evaluate lag screw cut-out under multiplanar loading representative of normal gait. Five surrogate pertrochanteric fracture specimens with lag screw fixation were loaded up to 20,000 cycles using a biaxial rocking motion (BRM) gait simulation protocol. Another five specimens were loaded using a standard uniaxial loading protocol. The BRM loading group exhibited combined varus collapse (5.4+/-2.9 degrees ) and backward rotation (7.2+/-2.8 degrees ). The uniaxial loading group exhibited four times less varus collapse (1.4+/-1.1 degrees ) as compared to the BRM group, and only negligible rotation. For correlation of lag screw migration in surrogate specimens to that in native bone, six human cadaveric specimens were subjected to BRM loading. The degree of varus collapse (8.5+/-7.7 degrees ) and rotation (7.2+/-6.4 degrees ) in cadaveric specimens were comparable to that in surrogate specimens, with the surrogate specimens showing significantly less variability. The results demonstrate that accounting for clinically realistic multiplanar loading vectors significantly affects implant migration, and therefore should be considered when evaluating the fixation strength of hip screw implants.

Biomechanical Phenomena↗

Depth-dependent strain of patellofemoral articular cartilage in unconfined compression.

This biomechanical study reports strain gradients in patellofemoral joint cross-sections of seven porcine specimens in response to 1% unconfined axial compression subsequent to specific amounts of off-set strain. Strain distributions were quantified with a customized laser-based electronic speckle pattern interferometry (ESPI) system in a non-contact manner, delivering high-resolution, high-sensitivity strain maps over entire patellofemoral cartilage cross-sections. Strain reports were evaluated to determine differences in strain magnitudes between the superficial, middle, and deep cartilage layers in femoral and patellar cartilage. In addition, the effect of 5%, 10%, 15%, and 20% off-set strain on depth-dependent strain gradients was quantified. Regardless of the amount of off-set strain, the superficial layer of femoral cartilage absorbed the most strain, and the deep layer absorbed the least strain. These depth-dependent strain gradients were most pronounced for 5% off-set strain, at which the superficial layer absorbed on average 5.7 and 23.7 times more strain as compared to the middle and deep layers, respectively. For increased off-set strain levels, strain gradients became less pronounced. At 20% off-set strain, differences in layer-specific strain were not statistically significant, with the superficial layer showing a 1.4 fold higher strain as the deep layer. Patellar cartilage exhibited similar strain gradients and effects of off-set strain, although the patellar strain was on average 19% larger as compared to corresponding femoral strain reports. This study quantified for the first time continuous strain gradients over patellofemoral cartilage cross-sections. Next to provision of a detailed functional characterization of normal diarthrodial joints, this novel experimental approach holds considerable attraction to investigate joint degenerative processes.

Animals↗

Emergent stabilization of pelvic ring injuries by controlled circumferential compression: a clinical trial.

BACKGROUND: Pelvic ring injuries are associated with a high incidence of mortality mainly due to retroperitoneal hemorrhage. Early stabilization is an integral part of hemorrhage control. Temporary stabilization can be provided by a pelvic sheet, sling, or an inflatable garment. However, these devices lack control of the applied circumferential compression. We evaluated a pelvic circumferential compression device (PCCD), which allows for force-controlled circumferential compression. In a prospective clinical trial, we documented how this device can provide effective reduction of open-book type pelvic injuries without causing overcompression of lateral compression type injuries. METHODS: Sixteen patients with pelvic ring injuries were enrolled. Pelvic fractures were temporarily stabilized with a PCCD until definitive stabilization was provided. Anteroposterior pelvic radiographs were obtained before and after PCCD application, and after definitive stabilization. These radiographs were analyzed to quantify pelvic reduction due to the PCCD in comparison to the quality of reduction after definitive stabilization. Results were stratified into external rotation and internal rotation fracture patterns. RESULTS: In the external rotation group, the PCCD significantly reduced the pelvic width by 9.9 +/- 6.0%. This reduction closely approximated the 10.0 +/- 4.1% reduction in pelvic width achieved by definitive stabilization. In the internal rotation group, the PCCD did not cause significant overcompression. No complications were observed. CONCLUSIONS: A PCCD can effectively reduce pelvic ring injuries. It poses a minimal risk for overcompression and complications as compared with reduction alternatives that do not provide a feedback on the applied reduction force.

Adolescent↗

Hinged external fixation of the knee: intrinsic factors influencing passive joint motion.

OBJECTIVE: To measure changes in knee kinematics after the application of articulated external fixators along a previously described knee flexion/extension axis and 16 specific "off-axis" fixator hinge configurations. DESIGN: Cadaver, biomechanical study. SETTING: Biomechanics laboratory. PARTICIPANTS: Nine fresh cadaver knee specimens. INTERVENTION: Each specimen was mounted on a custom-built frame that constrained the knee to move about a fixed flexion/extension axis. Passive knee motion was induced, and the resulting flexion moment was measured. Data were collected for the on-axis fixator position and 16 distinct rotational and translational off-axis positions. In addition, effects of tibial translation and rotation were investigated. MAIN OUTCOME: Range of motion (ROM) attainable within a moment envelope of +/-1 N-m and average energy required to impart movement. RESULTS: The average ROM for unconstrained knees was 122 degree. Constraining the knee to rotation around an on-axis aligned hinge significantly reduced the ROM by 35% to 79 degree. The 5-mm posterior translated hinge was the only alignment to show on average a slightly larger ROM (86 degree) than the on-axis hinge. All other hinge alignments showed decreased average ROM compared with the on-axis position. Tibiofemoral alignments significantly affected the obtainable ROM for the on-axis aligned hinge. CONCLUSION: It was not possible to replicate precisely the complex kinematics of the knee using a single axis fixator over the entire ROM. Using the axis of rotation previously defined in the literature, however, it was possible to obtain a limited ROM of the knee without placing excessive forces on the periarticular structures.

Aged↗

A laboratory model to evaluate cutout resistance of implants for pertrochanteric fracture fixation.

OBJECTIVES: To establish a laboratory model of implant cutout, which can evaluate the effect of implant design on cutout resistance in a clinically realistic "worst case" scenario. SETTING: Orthopaedic biomechanics laboratory. DESIGN: Implant cutout was simulated in an unstable pertrochanteric fracture model, which accounted for dynamic loading, osteoporotic bone, and a defined implant offset. For model characterization, lag screw cutout was simulated in human cadaveric specimens and in polyurethane foam surrogates. Subsequently, foam surrogates were used to determine differences in cutout resistance between 2 common lag screws (dynamic hip screw, Gamma) and 2 novel blade-type implant designs (dynamic helical hip system, trochanteric fixation nail). MAIN OUTCOME MEASURES: Implant migration was continuously recorded with a spatial motion tracking system as a function of the applied loading cycles. In addition, the total number of loading cycles to cutout failure was determined for specific load amplitudes. RESULTS: Implant migration in polyurethane surrogates closely correlated with that in cadaveric specimens, but yielded higher reproducibility and consistent cutout failure. The cutout model was able to delineate significant differences in cutout resistance between specific implant designs. At any of 4 load amplitudes (0.8 kN, 1.0 kN, 1.2 kN, 1.4 kN) dynamic hip screw lag screws failed earliest. The gamma nail lag screw could sustain significantly more loading cycles than the dynamic hip screw. Of all implants, trochanteric fixation nail implants demonstrated the highest cutout resistance. CONCLUSIONS: Implant design can significantly affect the fixation strength and cutout resistance of implants for pertrochanteric fracture fixation. The novel cutout model can predict differences in cutout resistance between distinct implant designs.

Aged↗

Noninvasive reduction of open-book pelvic fractures by circumferential compression.

OBJECTIVES: To determine the efficacy and optimal application parameters of circumferential compression to reduce external rotation-type pelvic fractures. DESIGN: Biomechanical investigation on human cadaveric specimens. SETTING: Biomechanics laboratory. INTERVENTION: Partially stable and unstable external rotation injuries of the pelvic ring (OTA classification 61-B1 and 61-C1) were created in seven human cadaveric specimens. A prototype pelvic strap was applied subsequently at three distinct transverse levels around the pelvis. Circumferential pelvic compression was induced by gradual tensioning of the strap to attempt complete reduction of the symphysis diastasis. MAIN OUTCOME MEASUREMENTS: Pelvic reduction was evaluated with respect to strap tension and the strap application site. The effect of circumferential compression on intraperitoneal pressure and skin-strap interface pressure was measured. RESULTS: A successive increase in circumferential compression consistently induced a gradual decrease in symphysis diastasis. An optimal strap application site was determined, at which circumferential compression most effectively yielded pelvic reduction. The minimum strap tension required to achieve complete reduction of symphysis diastasis was determined to be 177 +/- 44 Newtons and 180 +/- 50 Newtons in the partially stable and unstable pelvis, respectively. CONCLUSIONS: Application of circumferential compression to the pelvic soft tissue envelope with a pelvic strap was an efficient means to achieve controlled reduction of external rotation-type pelvic fractures. This study derived application parameters with direct clinical implication for noninvasive emergent management of traumatic pelvic ring disruptions.

Aged↗