PubMed Health⌕ Search

Biomedical subjects

Michael C Fitzgerald

Publications and source records attributed to Michael C Fitzgerald.

24 records · Page 2Linked to original sources

Identification and validation of a potential lung cancer serum biomarker detected by matrix-assisted laser desorption/ionization-time of flight spectra analysis.

Many abnormalities detected in the thorax by routine conventional imaging studies are benign, yet all require further evaluation because of the concern for cancer. To address this deficiency and develop a serum biomarker for lung cancer, we designed a matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) based platform to display the proteins present in the serum of patients with or without lung cancer, and then challenged the scientific community to analyze these data with the aim of determining specific ion signal differences among the resulting spectra. The most statistically significant ion peak identified by the various analysis algorithms that differentiated the serum of patients with lung cancer from the serum of individuals without lung cancer was found at m/z 11,702. We identified the protein responsible for this ion peak as serum amyloid A (SAA; M(r) = 11,682.7) by partial purification followed by in-gel digestion and peptide mapping. By enzyme-linked immunosorbent assay, we showed SAA to be present at 286 ng/mL in the serum of cancer patients vs. 34.1 ng/mL in the serum of individuals without cancer. These data suggest that the combination of MALDI-TOF MS and computer analysis can be a powerful tool in the search for serum biomarkers of lung cancer and other diseases.

Adenocarcinoma↗

A new H/D exchange- and mass spectrometry-based method for thermodynamic analysis of protein-DNA interactions.

The application of SUPREX (stability of unpurified proteins from rates of H/D exchange) to the thermodynamic analysis of protein-DNA complexes is described. A series of five model protein-DNA complexes involving two known DNA binding proteins, Arc repressor and CopG, were analyzed in order to determine the accuracy, precision, and generality of the SUPREX technique for quantifying the strength of protein-DNA interactions. For protein-DNA complexes that reversibly unfold in a two-state manner, we demonstrate that reasonably precise Kd values in agreement with those determined by conventional techniques can be determined by SUPREX. In the case of protein-DNA complexes that are not well modeled by a two-state unfolding mechanism, we find that relative binding affinities can be determined in the SUPREX experiment.

Bacterial Proteins↗

A general mass spectrometry-based assay for the quantitation of protein-ligand binding interactions in solution.

A new method that utilizes matrix-assisted laser desorption/ionization (MALDI) mass spectrometry and exploits the hydrogen/deuterium (H/D) exchange properties of proteins was developed for measuring the thermodynamic properties of protein-ligand complexes in solution. Dissociation constants (Kd values) determined by the method for five model protein-ligand complexes that included those with small molecules, nucleic acids, peptides, and other proteins were generally in good agreement with Kd values measured by conventional methods. Important experimental advantages of the described method over existing methods include: the ability to make measurements in a high-throughput and automated fashion, the ability to make measurements using only picomole quantitities of protein, and the ability to analyze either purified or unpurified protein-ligand complexes.

Animals↗

A stable dimer in the pH-induced equilibrium unfolding of the homo-hexameric enzyme 4-oxalocrotonate tautomerase (4-OT).

4-Oxalocrotonate tautomerase (4-OT) is a multimeric, bacterial enzyme comprised of 6 identical 62-amino acid subunits, which associate under native conditions to form a homo-hexameric structure stabilized entirely by noncovalent interactions. We have previously shown that the GuHCl-induced equilibrium unfolding of 4-OT at pH 8.5 is well modeled as a two-state process involving only hexamer and unfolded monomer; and we have obtained spectroscopic evidence that intermediate state(s) is (are) populated in the equilibrium unfolding reaction at pHs 6.0 and 7.4 [Silinski, P., Allingham, M. J., and Fitzgerald, M. C. (2001) Biochemistry 40, 4493-4502]. Here, we report on the pH-induced equilibrium unfolding of 4-OT using size-exclusion chromatography (SEC), far-UV-circular dichroism (CD) spectroscopy, and catalytic activity measurements over the pH range from 1.5 to 10.1. Our results indicate that the native hexamer of 4-OT is the predominant species in solution at pHs > or =6.2, that a partially folded dimeric state of 4-OT is stabilized in solution at pH 4.8, and that the enzyme is largely denatured in strongly acidic solutions (pH < or =3.1). GuHCl-induced equilibrium unfolding studies on 4-OT at pH 4.8 indicate that the folded 4-OT dimer populated at this pH is stabilized by 11.7 kcal.mol(-1). The results of biophysical studies on a fluorescent analogue of the enzyme, 4-OT(F50Y), and the results of UV photo-cross-linking studies on a synthetically derived 4-OT analogue, 4-OT(P1Bpa), suggest the polypeptide chains in the 4-OT dimer are nativelike in structure with the exception of their C-termini.

Catalysis↗

Thermodynamic stability measurements on multimeric proteins using a new H/D exchange- and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry-based method.

We recently reported on a new H/D exchange- and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry-based technique, termed SUPREX, that removes several important limitations associated with measuring the thermodynamic stability of proteins. In contrast to conventional spectroscopy-based techniques for characterizing the equilibrium unfolding behavior of proteins, SUPREX is amenable to the thermodynamic analysis of both purified and unpurified proteins using mg to ng quantities of material. Here we report on the application of SUPREX to the analysis of multimeric protein systems. Included in this work are the SUPREX results we obtained in studies on six model multimeric proteins including the GCN4p1 dimer, the coil-V(a)L(d) trimer, the 4-oxalocrotonate tautomerase (4-OT) hexamer, the Trp repressor (TrpR) dimer, the Arc repressor (ArcR) dimer, and an ArcR mutant (the (DOA20)ArcR) dimer which contained two destabilizing mutations including an Asp to Ala mutation at position 20 and an amide to ester bond mutation between amino acid (aa) residues 19 and 20. As part of the work described here, we present a new method for the analysis of SUPREX data that is generally applicable to both monomeric and multimeric protein systems. Our results on the model proteins in this study indicate that this new method can be used to determine folding free energies for proteins with the accuracy and precision of conventional spectroscopy-based methods.

Bacterial Proteins↗

High-throughput screening assay for the tunable selection of protein ligands.

Here, we describe a new protein-ligand binding assay that is amenable to high-throughput screening applications. The assay involves the use of SUPREX (stability of unpurified proteins from rates of H/D exchange), a new H/D exchange and mass spectrometry-based technique we recently developed for the quantitative analysis of protein-ligand binding interactions. As part of this work, we describe a new high-throughput SUPREX protocol, and we demonstrate that this protocol can be used to efficiently screen peptide ligands in a model combinatorial library for binding to a model protein system, the S-protein. The high-throughput SUPREX protocol developed here is generally applicable to a wide variety of protein ligands, including DNA, small molecules, metals, and other proteins. On the basis of the results of the model study in this work, one person with access to one MALDI mass spectrometer should be able to screen approximately 10 000 compounds per 24-h period using the protocol described here. With full automation and the use of a commercially available MALDI mass spectrometer optimized for high-throughput analyses, we estimate that the SUPREX-based assay described here could be used to screen on the order of 100 000 ligands per day.

Automation↗