Clinical approach to a child with abdominal pain who might have appendicitis.

Appendicitis can usually be diagnosed on completion of a history and physical examination (abdominal pain, vomiting, right lower quadrant tenderness and guarding), although laboratory evaluation with a urinalysis and white blood cell count can be of assistance. In the few cases where doubt remains, plain films of the chest and abdomen can be helpful. Whether and when further imaging is indicated remains controversial. We reviewed reports of studies published since 2003 in which the sensitivity and specificity of CT and sonography for diagnosing appendicitis were determined. Sonography had an average sensitivity of 87.1% and an average specificity of 89.2% in the nine studies reported during that period. The average sensitivity of CT was 90.8% in 11 studies during that period, and there was an average specificity of 94.2% in 10 studies. We also looked at data from 299 patients who underwent appendectomies at our hospital. Of the appendices removed, only 10.7% did not have appendicitis. In many cases, CT or US imaging data were available in the form of reports or images or both from outside institutions. CT and US images were also available from our institution when the diagnosis was in question. This is how patients present in the real world-with studies that might not be the best, might not have been indicated, and might not have images available for another interpretation. Among patients operated on with neither CT nor US images, 10.9% did not have appendicitis. Among those in whom US imaging had been performed, 11.1% were negative for appendicitis, and among those in whom CT had been performed, 9.7% were negative. Although these studies were necessary because they were performed in patients whose diagnosis was the most difficult, it is in every patient's best interest to have a thorough examination by a surgeon prior to having a CT scan.

Abdominal Pain↗

Totally minimally invasive robot-assisted unstented pyeloplasty using the Zeus Microwrist Surgical System: an animal study.

BACKGROUND: Minimally invasive pyeloplasty is a difficult procedure even for an expert laparoscopic surgeon. The major difficulty is associated with the limitations of intracorporeal suturing and knot tying. Surgical robots, which hold minimally invasive surgical instruments, have wrists and provide tremor filtration and motion scaling that might be expected to facilitate complex procedures in newborns. METHODS: Seven survival piglets (4.0-7.5 kg) underwent a totally minimally invasive robot-assisted unstented pyeloplasty employing the Zeus Robotic Microwrist System. The ureter was transected at the level of the ureteropelvic junction and 8 mm was resected. The unstented anastomosis was fashioned with running suture and intracorporeal knot tying. The animals were recovered and intravenous urography was performed at 1 month. After sacrifice, the anastomosis and the kidney were evaluated grossly and histologically for leak, caliber, and healing. RESULTS: All animals survived the procedure without postoperative complications. The mean robotic setup time was 19 minutes (range, 10-30 min), mean anastomosis time 51 minutes (range, 39-63 min), and mean total operation time 76 minutes (range, 57-87 min). The urography showed hydronephrosis in the first animal. The other 6 animals had no abnormalities. Histopathology demonstrated severe hydronephrosis in the first pig and moderate hydronephrosis in the sixth and seventh. All other animals had no sign of hydronephrosis. All anastomoses were well healed and intact. CONCLUSIONS: Robot-assisted laparoscopic pyeloplasty is a technically feasible procedure with acceptable morbidity in an animal model. The robotic technology enhances surgical dexterity and precision. Robotic assistance can increase the applicability of minimally invasive surgery to complex procedures in children.

Anastomosis, Surgical↗

Using quantitative methods to improve the diagnostic workup for abdominal pain in children.

INTRODUCTION: The differential diagnosis of abdominal pain in children can be challenging. We applied quantitative decision-making methods to this process and sought to determine if their use provided measurable benefit. METHODS: After obtaining institutional review board approval, we recorded key elements of the history, physical examination, laboratory, and imaging evaluations along with the cost and the time spent in the emergency department (ED) for children presenting with abdominal pain. Initially, data were collected (group 1, n = 1366 patients) and then presented to the ED pediatricians. For subsequent patients, ED physicians received a sheet specific to that patient's age and sex reporting the most common diagnoses and the elements of the evaluation that had proven most useful (group 2, n = 624 patients). We compared the difference in length of stay and costs before and after intervention, between study groups, by age groups, and separately by sex using a 2-factor analysis of variance. RESULTS: The diagnostic workup cost less in boys aged 2 to 12 years after the intervention. In boys and girls older than 12 years, the cost trended lower. DISCUSSION: This study demonstrates that ED physicians equipped with specific information were able to complete their diagnostic evaluation of children presenting with abdominal pain at a lower cost.

Abdominal Pain↗

Computer-assisted, robot-enhanced open microsurgery in an animal model.

BACKGROUND: Computer-assisted, robot-enhanced surgery improves laparoscopic and thoracoscopic surgery through tremor filtration, motion scaling, articulation, and improved ergonomics. Surgeons perform many open cases under magnification that magnifies the tremor present in all surgeons' hands, so the tremor filtration and motion scaling of robotic surgery may improve microsurgery. Our goal was to compare microvascular anastomoses performed with a robot-enhanced technique with a standard technique. METHODS: We performed end-to-end anastomoses in 1-mm rat femoral arteries with interrupted 10-0 suture. We compared the anastomotic time, patency, and leak rates between traditional microsurgery techniques (by hand) and a robot-enhanced technique using the Zeus robotic surgery system (Computer Motion, Goleta, California). The surgeon used an operative microscope for visualization in both techniques. RESULTS: We performed 30 anastomoses by hand and 31 with Zeus. We observed a remarkable degree of tremor filtration in the robot-enhanced cases. Anastomotic times for both techniques demonstrated a learning curve. Anastomoses done by hand (mean time, 17.2 minutes) were significantly faster than those done with Zeus (mean time, 27.6 minutes) (P = 0.0006). All anastomoses from both groups were patent, and none leaked after 3 minutes. CONCLUSION: The Zeus system is effective at performing complex, open, microsurgery tasks in vivo. There was no measurable benefit from the remarkable tremor filtration and motion scaling offered by robot-enhanced surgery.

Anastomosis, Surgical↗

Laparoscopic Morgagni hernia repair in children using robotic instruments.

BACKGROUND: Robotic surgery enhances minimally invasive surgery through tremor filtration, motion scaling, indexed movement, articulation, and improved ergonomics. We report 2 cases of computer- assisted, robot-enhanced, laparoscopic repair of Morgagni hernia in a 23-month-old weighing 10.2 kg and a 5-year-old weighing 21.6 kg. METHODS: Four 5 mm trocars were used to gain access to the abdomen. In the first case, standard laparoscopic instruments were used to dissect the liver from the rim of the defect and then reduce the hernia. In the second, robotic instruments were used for this dissection. In both cases, the robot- enhanced instruments were used to close the hernia defects with interrupted, nonabsorbable suture, using intracorporeal knot tying. RESULTS: Both cases were completed laparoscopically without a patch. The robotic system took 9 minutes to set up and drape. The average operative time was 227 minutes. The older child tolerated oral intake the day of surgery and went home the following day. The younger child tolerated oral intake and went home on postoperative day 2. CONCLUSION: Robot-assisted laparoscopic Morgagni hernia repair is feasible.

Child, Preschool↗

Postoperative outcomes of extremely low birth-weight infants with necrotizing enterocolitis or isolated intestinal perforation: a prospective cohort study by the NICHD Neonatal Research Network.

OBJECTIVE: Purposes of this study were: 1) to compare mortality and postoperative morbidities (intra-abdominal abscess, wound dehiscence, and intestinal stricture) in extremely low birth weight (ELBW) infants who underwent initial laparotomy or drainage for necrotizing enterocolitis (NEC) or isolated intestinal perforation (IP); 2) to determine the ability to distinguish NEC from IP preoperatively and the importance of this distinction on outcome measures; and 3) to evaluate the association between extent of intestinal disease determined at operation and outcome measures. BACKGROUND: ELBW infants who undergo operation for NEC or IP have a postoperative, in-hospital mortality rate of approximately 50%. Whether to perform laparotomy or drainage initially is controversial. Also unknown is the importance of distinguishing NEC from IP and the current ability to make this distinction based on objective data available prior to operation. METHODS: A prospective, multicenter cohort study of 156 ELBW infants at 16 neonatal intensive care units (NICU) within the NICHD Neonatal Research Network. RESULTS: Among the 156 enrolled infants, 80 underwent initial peritoneal drainage and 76 initial laparotomy. Mortality rate was 49% (76 of 156). Ninety-six patients had a preoperative diagnosis of NEC and 60 had presumed IP. There was a high level of agreement between the presumed preoperative diagnosis and intraoperative diagnosis in patients undergoing initial laparotomy (kappa = 0.85). The relative risk for death with a preoperative diagnosis of NEC (versus IP) was 1.4 (95% confidence interval, 0.99-2.1, P = 0.052). The overall incidence of postoperative intestinal stricture was 10.3%, wound dehiscence 4.4%, and intra-abdominal abscess 5.8%, and did not significantly differ between groups undergoing initial laparotomy versus initial drainage. CONCLUSIONS: Survival to hospital discharge after operation for NEC or IP in ELBW neonates remains poor (51%). Patients with a preoperative diagnosis of NEC have a relative risk for death of 1.4 compared with those with a preoperative diagnosis of IP. A distinction can be made preoperatively between NEC and IP based on abdominal radiographic findings and the patient's age at operation. Future randomized trials that compare laparotomy versus drainage would likely benefit from stratification of treatment assignment based on preoperative diagnosis.

Drainage↗

Congenital diaphragmatic hernia: associated anomalies and antenatal diagnosis. Outcome-related variables at two Detroit hospitals.

This retrospective study reviews the medical records of 77 fetuses and babies with congenital diaphragmatic hernia (CDH) referred to two hospitals in Detroit from 1986 through 2000. The aims were to examine the effects on outcome of multiple variables, especially the type of CDH, associated anomalies, and ultrasound prognostic parameters. Ultrasound measurements of head (HC), chest (CC), and abdominal circumferences (AC) were obtained from videotapes. ANOVA and chi-square analysis were used to determine statistical significance between groups and proportions. Eighty-nine percent (65/73) of pregnancies resulted in live births, and 54% (35/65) of patients survived past 30 days. Liveborn patients with low APGAR scores were less likely to survive. Forty-three percent (30/70) had major associated anomalies, with cardiac anomalies constituting about 52% (33/64) of the major associated anomalies. Seventy percent of patients with isolated CDH survived versus 36% of patients with both CDH and cardiac anomalies. Sixty-seven percent (8/12) of fetuses antenatally diagnosed before 25 weeks of gestation survived past 30 days of birth. The survival rate of right-sided CDH with liver herniation was 80% (8/10), compared with 29% (4/14) for left-sided CDH with liver herniation (p=0.088). There was a significant linear relationship (r=0.603, p =0.029) between CC/AC and CC/HC among patients with CDH; survivors had higher CC/AC and CC/HC values than nonsurvivors. These results support the utility of CC/AC and CC/HC measurements and the presence of liver herniation as important prognostic factors that can be used in antenatal counseling and in planning clinical trials.

Abnormalities, Multiple↗

Robotics in pediatric surgery: perspectives for imaging.

Robotic surgery will give surgeons the ability to perform essentially tremorless microsurgery in tiny spaces with delicate precision and may enable procedures never before possible on children, neonates, and fetuses. Collaboration with radiologists, engineers, and other scientists will permit refinement of image-guided technologies and allow the realization of truly remarkable concepts in minimally invasive surgery. While robotic surgery is now in clinical use in several surgical specialties (heart bypass, prostate removal, and various gastrointestinal procedures), the greatest promise of robotics lies in pediatric surgery. We will briefly review the history and background of robotic technology in surgery, discuss its present benefits and uses and those being explored, and speculate on the future, with attention to the current and potential involvement of imaging modalities and the role of image guidance.

Diagnostic Imaging↗

Computer-assisted robot-enhanced laparoscopic fundoplication in children.

BACKGROUND/PURPOSE: Robotic surgery improves laparoscopic surgery through a more natural interface, tremor filtration, motion scaling, and additional degrees of freedom of the instruments. Here, the authors report that experience with robot-assisted fundoplication in children. METHODS: The authors have performed 15 laparoscopic fundoplications with the Zeus Robotic Surgery System and retrospectively reviewed prospectively collected data on set-up time, operating time, and outcome. RESULTS: All cases were completed successfully: one Heller myotomy with Dor fundoplication and 14 Nissen fundoplications. Patients ranged from 2 months to 18 years old (mean, 4.3 years) and from 3.4 kg to 37.7 kg (mean, 13.0 kg). There were no technical errors, equipment errors, or conversions. There were no complications in the first 30 days after surgery. The operating time declined from 323 minutes for the first case to 180 minutes for the last (mean, 195 minutes). The 14th case was the shortest at 123 minutes. Setting up the robotic surgery system took an average of 11 minutes. The surgeons perceived benefits of greater ease and confidence in suture placement and knot tying. CONCLUSIONS: The authors have successfully used surgical robots for gastric fundoplication at a pediatric teaching hospital. Our experience with this operation has shown the additional dexterity that the robot provides and will pave the way to more complex procedures.

Adolescent↗

Raman spectroscopy for neoplastic tissue differentiation: a pilot study.

BACKGROUND: Several changes occur during the transformation of normal tissue to neoplastic tissue. Such changes in molecular composition can be detected by Raman spectroscopy. Raman spectroscopy is a nondestructive method of measuring these changes, which suggests the possibility of real-time diagnosis during medical procedures. METHODS: This study seeks to evaluate the ability of Raman spectra to distinguish tissues. The Raman signatures of normal kidney, lung, and liver tissue samples from pigs and rats were characterized in vitro. Further, a human neuroblastoma and a hepatoblastoma, obtained at resection were also studied. RESULTS: The Raman spectra of the animal samples of kidney, liver, and lung are distinctly different in the intensity distribution of the Raman peaks. Further, the spectra of a given organ from pigs and rats, although similar, were different enough to distinguish between the 2 animals. In the patient tissues, the Raman spectra of normal liver, viable tumor, and fibrotic hepatoblastoma were very different. Fibrotic tissue showed a greater concentration of carotenoids, whereas viable tissue was rich in proteins and nucleic acids. The normal tissue showed both components. Similar differences were also seen in the neuroblastoma tissue. CONCLUSIONS: The results of this study show the potential use of Raman spectroscopy in clinical diagnosis.

Animals↗

Robotically assisted esophago-esophagostomy in newborn pigs.

PURPOSE: Repair of esophageal atresia and tracheoesophageal fistula (TEF) in the newborn is challenging when done as an open procedure but only a few surgeons have attempted this with minimally invasive surgery (MIS). Surgical robots that hold MIS instruments have wrists and provide tremor filtration and motion scaling, which might be expected to facilitate complex procedures in small spaces such as an esophageal anastomosis in a newborn. METHODS: Seven newborn pigs weighing 2 to 3 kg were used as a model. The authors performed an esophageal resection and end-to-end anastomosis using the Zeus Microwrist Robotic Surgical System. The authors monitored the following data-Zeus robotic set-up time, operating time, esophageal dissection time, and anastomosis time. After 1 month, the animals were anesthetized to perform esophagram and than were killed. RESULTS: In these very small animals the space available for performing an anastomosis is very limited, approximately 2 cm3. Two pigs each died 18 days postoperatively. One animal could not eat and died during esophageal dilation. The second pig died of unrelated enteritis. Neither had evidence of anastomotic leak at autopsy. The esophagram of the 5 pigs that survived for 30 days showed no narrowing or proximal dilation in 2. In 3 there was some stenosis requiring dilation. Histopathology was done on each operated animal. Two of the anastomoses were well healed, and 5 showed only focal small ulceration. CONCLUSIONS: Robotic assistance facilitates an MIS approach to the upper esophagus even in the limited space of the infant chest.

Anastomosis, Surgical↗

Robot-enhanced fetoscopic surgery.

BACKGROUND: Fetoscopic surgery carries with it less maternal morbidity than open fetal surgery. Robotic surgery facilitates endoscopic surgery through tremor filtration, motion scaling, indexed movement, articulation, and improved ergonomics. The goal of the authors was to explore using a robotic surgery platform in a fetal animal model. METHODS: Using the Zeus Robotic Surgery System (Computer Motion, Santa Barbara, CA), fetoscopic surgery in pregnant sheep was performed using a variety of techniques: uterus exteriorized or totally percutaneous and with liquid or gas insufflation. Using the percutaneous technique and gas insufflation, the authors created and sutured fetal skin and fascial defects. The ewes were recovered and killed 2 weeks postoperatively, and autopsies were performed on them and their fetuses. RESULTS: In the exteriorized uterus model, instrument movement was unpredictable and fluid leaked. In the fluid environment, clouding of the visual field and difficulty in immobilizing the fetus were major difficulties. In the survival model, 4 of the 6 fetuses survived to autopsy at 2 weeks and showed good healing grossly and histologically. CONCLUSIONS: The Zeus Robotic Surgery System can be used for fetoscopic surgery in a sheep model. The percutaneous approach with a nitrous oxide environment is the most effective. Advantages of robotic surgery may be applicable in fetoscopic surgery, but further work in a primate model is required.

Animals↗

Central venous catheter sepsis in surgical newborns.

We examined central venous catheter (CVC) sepsis in newborn surgical patients, as this group appeared to have a higher incidence of this complication. During a 3-year period 79 patients on the surgical service required a tunneled, cuffed, Broviac CVC. Nineteen patients (24% or 9.9 episodes per 1000 catheter days) had proven sepsis and 8 (10% or 1.9/1000 catheter days) had suspected sepsis. An intestinal stoma was definitely related to CVC sepsis ( p<0.001). Other risk factors included lower gestational age, more operations, and younger age at first stoma. Temperature, white blood cell (WBC) count, and platelet count did not correlate with CVC sepsis. We found no better indicator of CVC sepsis than the presentation of an ill child. Certainly temperature, WBC, and platelet count are not reliable indicators. Surgeons have little control over the factors that were found to be related to CVC sepsis. It would appear reasonable from these results to maintain a high index of suspicion in the high-risk groups, to use peripherally inserted central catheters (PIC lines) as the first line of long-term vascular access, and to bring CVCs out of a nonabdominal site, perhaps the scalp, in patients with stomas.

Catheterization, Central Venous↗

Anterior bridging bronchus.

Previously reported patients with a bridging bronchus (BB) presented with respiratory distress. In addition, each patient had one or more associated anomalies. All but two patients progressed to cardiopulmonary failure and death. We describe a case of an anterior BB without associated anomalies, who did well without operative intervention. This patient presented with a cough at 6 months of age. Chest X-ray was normal, but due to suspicion of foreign body aspiration, bronchoscopy was performed, which revealed a third bronchus at the carina. Bronchography demonstrated the anatomy of the BB. The patient has continued to do well without further intervention.

Bronchi↗

Robotics and the pediatric surgeon.

Surgical robots are enabling devices for minimally invasive (laparoscopic) surgery (MIS). They use a computer to enhance a surgeon's skills as hand movements are transmitted to robotic arms. The computer filters tremor, which becomes important at high magnifications of 10 to 15 times available in MIS. It also provides motion scaling so that large hand movements are converted to very small movements of the robotic arm. The robotic arms also have wrists that make suturing and knot tying far more accurate and efficient. Surgical robots are currently used clinically for procedures such as MIS Nissen fundoplication, cholecystectomy, and splenectomy. Laboratory experience indicates that they may provide advantages for newborn procedures such as portoenterostomy for biliary atresia and repair of esophageal atresia and tracheoesophageal fistula. They have a potential for making possible MIS procedures, which can only be done open now, and for introducing entirely new procedures as well as for the performance of procedures by operators distant from the patient.

Age Factors↗

Robotic surgery: an update.

Minimally invasive surgery techniques have revolutionized surgery. Robotic surgery may be the next revolution in surgical technology. Robotics coupled with minimally invasive surgery and microscopic surgery provides the potential to do more complex and more precise tasks. Robotic surgery offers tremor filtration, motion scaling, indexed movements, additional degrees of freedom, and improved ergonomics. We explore robotic history, the present surgical technology, the current clinical cases and research, and the future of robotics. We will look specifically at the birth and progress of our own problem.

Humans↗