Magnetic resonance lung function--a breakthrough for lung imaging and functional assessment? A phantom study and clinical trial.

BACKGROUND: Chronic lung diseases are a major issue in public health. A serial pulmonary assessment using imaging techniques free of ionizing radiation and which provides early information on local function impairment would therefore be a considerably important development. Magnetic resonance imaging (MRI) is a powerful tool for the static and dynamic imaging of many organs. Its application in lung imaging however, has been limited due to the low water content of the lung and the artefacts evident at air-tissue interfaces. Many attempts have been made to visualize local ventilation using the inhalation of hyperpolarized gases or gadolinium aerosol responding to MRI. None of these methods are applicable for broad clinical use as they require specific equipment. METHODS: We have shown previously that low-field MRI can be used for static imaging of the lung. Here we show that mathematical processing of data derived from serial MRI scans during the respiratory cycle produces good quality images of local ventilation without any contrast agent. A phantom study and investigations in 85 patients were performed. RESULTS: The phantom study proved our theoretical considerations. In 99 patient investigations good correlation (r = 0.8; p < or = 0.001) was seen for pulmonary function tests and MR ventilation measurements. Small ventilation defects were visualized. CONCLUSION: With this method, ventilation defects can be diagnosed long before any imaging or pulmonary function test will indicate disease. This surprisingly simple approach could easily be incorporated in clinical routine and may be a breakthrough for lung imaging and functional assessment.

Adolescent↗

Quantitative lung perfusion mapping at 0.2 T using FAIR True-FISP MRI.

Perfusion measurements in lung tissue using arterial spin labeling (ASL) techniques are hampered by strong microscopic field gradients induced by susceptibility differences between the alveolar air and the lung parenchyma. A true fast imaging with steady precession (True-FISP) sequence was adapted for applications in flow-sensitive alternating inversion recovery (FAIR) lung perfusion imaging at 0.2 Tesla and 1.5 Tesla. Conditions of microscopic static field distribution were assessed in four healthy volunteers at both field strengths using multiecho gradient-echo sequences. The full width at half maximum (FWHM) values of the frequency distribution for 180-277 Hz at 1.5 Tesla were more than threefold higher compared to 39-109 Hz at 0.2 Tesla. The influence of microscopic field inhomogeneities on the True-FISP signal yield was simulated numerically. Conditions allowed for the development of a FAIR True-FISP sequence for lung perfusion measurement at 0.2 Tesla, whereas at 1.5 Tesla microscopic field inhomogeneities appeared too distinct. Perfusion measurements of lung tissue were performed on eight healthy volunteers and two patients at 0.2 Tesla using the optimized FAIR True-FISP sequence. The average perfusion rates in peripheral lung regions in transverse, sagittal, and coronal slices of the left/right lung were 418/400, 398/416, and 370/368 ml/100 g/min, respectively. This work suggests that FAIR True-FISP sequences can be considered appropriate for noninvasive lung perfusion examinations at low field strength.

Adolescent↗

A comparative evaluation of a RARE-based single-shot pulse sequence for diffusion-weighted MRI of musculoskeletal soft-tissue tumors.

The purpose of this study was to evaluate the feasibility of a centric-reordered modified rapid acquisition with relaxation enhancement (mRARE) sequence for single-shot diffusion-weighted magnetic resonance imaging (DWI) of soft-tissue tumors in the musculoskeletal system. In the evaluation of this sequence, DWI was performed in a liquid phantom, in excised human tumor samples embedded in bovine muscle, and in nine patients suffering from different types of soft-tissue tumors. The measurements were compared to DWI using a spin-echo sequence and a single-shot echo planar imaging (EPI) sequence. The phantom measurements in water and dimethyl sulfoxide showed a difference of less than 5% when comparing the apparent diffusion coefficients (ADCs) determined by the mRARE sequence and the two other techniques. Comparing mRARE and EPI, the differences in the ADCs were about 10% in the excised tumor tissue and, typically, about 15% in vivo. ADCs between 0.8 x 10(-3) mm2/s and 1.4 x 10(-3) mm2/s, depending on the tumor type, were found in solid tumor tissue; in cystic tumor areas, ADCs greater than 2.0 x 10(-3) mm2/s were determined with the mRARE and the EPI sequences. Diffusion-weighted images of the mRARE sequence were less distorted than those acquired with the single-shot EPI sequence, and provided more anatomic information, since the muscle and fat signals were considerably higher.

Aged↗

MR imaging of lung parenchyma at 0.2 T: evaluation of imaging techniques, comparative study with chest radiography and interobserver analysis.

The purpose of this study was to evaluate low-field MR imaging of the lung parenchyma in comparison with postero-anterior (PA) and lateral chest radiographs (CR). One hundred one prospectively randomized patients who had received routine CR were additionally examined with magnetic resonance imaging (MRI) at 0.2 T. Utilized sequences were: constructive interference in steady state (CISS), true fast imaging in steady state precession (True-FISP) and T1-weighted spin-echo (T1SE). Consensus reading of two observers was performed for CR. Three other observers analyzed hardcopies of the MRI examinations for each sequence independently. The individual results for the comparisons between the sequences and CR were calculated using kappa coefficients with their corresponding confidence intervals. Additionally, an interobserver analysis was performed. The proportions of agreement for the three sequences compared with CR were high, with 0.93 for CISS, 0.89 for True-FISP and 0.91 for T1SE. The kappa coefficients and the corresponding confidence intervals were 0.81 [0.68; 0.95] for CISS, 0.72 [0.57; 0.88] for True-FISP and 0.78 [0.65; 0.92] for T1SE. Concerning CISS, differences between MRI and CR were mainly related to advantages resulting from cross-sectional imaging. The smallest 95% lower confidence bound of the three kappa measures for comparing the MR readers with each other was 0.97, indicating a high interobserver agreement. Low-field MRI of the lung parenchyma using the CISS sequence is well comparable with chest radiography and demonstrates slight advantages resulting from the cross-sectional imaging technique.

Adult↗

Assessment of the skeletal status by MR relaxometry techniques of the lumbar spine: comparison with dual X-ray absorptiometry.

PURPOSE: To measure lumbar spine T2*, T2, T2' and T1 MR relaxometry parameters and compare them with lumbar spine bone mineral density (BMD) in a group of postmenopausal women. MATERIALS AND METHODS: Lumbar spine T2*, T2, T2' and T1 MR relaxometry parameters and BMD values were assessed in 101 postmenopausal women (mean age: 61.8 +/- 7.1 (1 S.D.) years); of them 63 referred to as control subjects (group A, BMD T-scores > or = -2.5 S.D.) and 38 as osteoporotic (group B, BMD T-scores < -2.5 S.D.). All magnetic resonance imaging (MRI) examinations were performed on an 1.5 T imaging system using: (a) a 2D single slice multi echo (32 echoes) gradient echo (MEGRE) sequence (TR/TE1/TE32/FA: 160/2.7/74.93 ms/25 degrees for the T2* measurement, (b) a respiratory gated 2D single slice Multi Echo (16 echoes) Spin Echo (MESE) sequence (TR/TE1/TE16/FA: 2000-2500/22.5/360 ms/90 degrees) for the T2 measurement and (c) a 2D single slice multi TI (18 repeats) turbo Fast Low Angle Shot (turbo FLASH) sequence (TR/TE/TI1/TI16/FA: 11/4.2/10/5000 ms/10 degrees) for the T1 measurement. T2' was calculated from its definition equation: (1/T2' = 1/T2* - 1/T2). Lumbar spine BMD was assessed using DXA. RESULTS: All measured parameters showed statistically significant differences between groups A and B (from P < 0.05 to <0.001). All parameters showed significant associations with subject's age ranging from r = 0.245 (P < 0.05) for the T2 up to r = 0.377 (P < 0.001) for the T2*. All parameters showed significant associations with subject's BMD measurements ranging from r = -0.184 (P < 0.05) for the R1 = (1/T1) up to r = -0.345 (P < 0.0005) for the T2. CONCLUSION: Among the MR relaxometry parameters studied, T2* and T2 showed better discrimination of patients with osteoporosis from control subjects.

Absorptiometry, Photon↗

Steady-state free precession projection MRI as a potential alternative to the conventional chest X-ray in pediatric patients with suspected pneumonia.

Magnetic resonance imaging of the lung tissue is thought to be hardly possible due to physical limitations especially the low proton density, susceptibility, and motion artifacts. The objective of our study was to evaluate and refine a very fast MR technique at a low field strength which overcomes the limitations in MR lung imaging. Thirty-five investigations were performed in 30 pediatric patients with suspected pneumonia. The MR investigations were performed in coronal slice orientation without cardiac or respiratory triggering in a low-field MR system. An optimized true fast imaging with steady precession sequence was applied. The MR images and the corresponding conventional chest radiographs were evaluated. The examination time per slice was 1.6 s. No motion artifacts could be observed. The signal-to-noise ratio for pulmonary parenchyma ranged from 4.9 to 7.1. All pathological findings of the chest X-ray images were correctly identified by the MRI (kappa=0.82-0.85). Effusions as well as small pneumonic infiltrates were more precisely detected by the MRI investigation (kappa=0.82) as compared with X-ray. Low-field projection MRI is a promising alternative to pediatric chest X-ray. Due to its short examination time, it overcomes the physical limits of usual MRI methods and provides comparable diagnostic information.

Child↗

Pulmonary diffusing capacity: assessment with oxygen-enhanced lung MR imaging preliminary findings.

PURPOSE: To determine differences in the signal intensity (SI) time courses at oxygen-enhanced magnetic resonance (MR) lung imaging in healthy volunteers and patients with pulmonary diseases and to correlate these differences with pulmonary diffusing capacity. MATERIALS AND METHODS: Seventeen patients with pulmonary diseases and 11 healthy volunteers underwent oxygen-enhanced MR imaging while they breathed room air and 100% oxygen. A turbo spin-echo sequence with global or section-selective inversion pulses was used. For postprocessing, SI slope maps during the breathing of 100% oxygen were calculated. Mean SI slope and SI change values were compared with the diffusing capacity of the lung for carbon monoxide (DLCO). RESULTS: The SI slopes were significantly different for patients and volunteers (P < or = .05, Mann-Whitney U test). Linear correlations were detected between the DLCO and SI slopes for the section-selective inversion pulse (r(2) = 0.81) and the global inversion pulse (r(2) = 0.74). A lower correlation was associated with the SI change for the section-selective pulse (r(2) = 0.04; global pulse, r(2) = 0.81). Regional differences were seen in the SI slope and SI change maps. These differences correlated with findings on radiographs and computed tomographic scans. CONCLUSION: The SI slope during the breathing of 100% oxygen allows spatially resolved assessment of the pulmonary diffusion capacity.

Adult↗