PubMed Health⌕ Search

Biomedical subjects

Michael E Hyde

Publications and source records attributed to Michael E Hyde.

9 recordsLinked to original sources

AFM studies of metal deposition: instantaneous nucleation and the growth of cobalt nanoparticles on boron-doped diamond electrodes.

In situ atomic force microscopy (AFM) is used to study the growth of cobalt nuclei on a boron doped diamond electrode under potentiostatic control. The rate of growth of the nuclei at the electrode surface is monitored using AFM as a function of time at different deposition potentials. The nucleation of cobalt nuclei is found to be "instantaneous" and the growth of the nuclei is shown to be kinetically rather than diffusionally controlled over periods of tens and hundreds of seconds. At very short times (<10 seconds) the kinetics of nucleation are apparent.

Journal Article↗

4-Nitrobenzylamine partially intercalated into graphite powder and multiwalled carbon nanotubes: characterization using X-ray photoelectron spectroscopy and in situ atomic force microscopy.

We report the characterization of partial intercalation of 4-nitrobenzylamine (4-NBA) into edge-plane or edge-plane-like defect sites on the surface of both graphite powder and "bamboo-like" multiwalled carbon nanotubes (MWCNTs) using X-ray photoelectron spectroscopy (XPS). By comparing the XPS spectra of 4-NBA derivatized graphite powder and MWCNTs with that of graphite powder treated with benzylamine in a similar fashion, we conclude that benzylamine itself does not undergo partial intercalation. Using in situ atomic force microscopy, we are able to observe the partial intercalation of 4-NBA into an edge-plane-like "step" defect on the surface of a highly ordered pyrolytic graphite crystal in real time. Together these observations provide further evidence for the partial intercalation of 4-NBA and lead us to propose a new hypothesis to explain this phenomenon.

Journal Article↗

Electrochemical cell for surface analysis.

We present a simple cost-effective design for an HOPG electrode that is well suited to voltammetric experiments accompanied by surface analysis. The utility of the electrode is demonstrated by an AFM study on the morphology of electrodeposited MoO2 nanowires. The design can be applied to a wide range of electrode materials.

Journal Article↗

The detection of nitrate using in-situ copper nanoparticle deposition at a boron doped diamond electrode.

Electrochemical deposition from a 0.1 M sodium sulphate solution, containing Cu2+ (adjusted to pH 3 with hydrochloric acid) produced a well defined copper nanoparticle deposit on the surface of a boron doped diamond electrode. Changing conditions such as potential (-0.8, -1.0 and -1.2 V), time (5, 2 and 0.5 s) and concentration of Cu2+ (500, 250 and 100 microM) was found to give copper nanoparticles of varying size and particle density. The electrocatalytic properties of the copper surface towards nitrate reduction were explored. An in-situ copper nanoparticle production method was developed for the detection of nitrate; this involves electrodeposition, followed by linear sweep voltammetry for the reduction of nitrate and then application of a stripping potential to renew the electrode surface. The linear sweep was discovered to have homogenised the size of the nanoparticles but their number density was still dependant on the initial conditions of deposition. Some particles were still present at the surface after the stripping potential had been applied but repetitions of the procedure showed these did not have an effect on subsequent deposits. Optimisation of the method lead to applying a deposition potential of -0.8 V, at a BDD electrode for 5 s in a 0.1 M sodium sulphate solution (pH 3) containing 100 microM Cu2+ followed by a linear sweep at 1 V/s; this yielded a limit of detection of 1.5 microM nitrate. The analytical applicability of the technique was evaluated for nitrate detection in a natural mineral water sample and was found to agree well with that stated by the manufacturer.

Journal Article↗

Anodic stripping voltammetry of arsenic(III) using gold nanoparticle-modified electrodes.

A novel method for the detection of arsenic(III) in 1 M HCl at a gold nanoparticle-modified glassy carbon electrode has been developed. The gold nanoparticles were electrodeposited onto the glassy carbon electrode via a potential step from +1.055 to -0.045 V vs SCE for 15 s from 0.5 M H2SO4 containing 0.1 mM HAuCl4. The resulting electrode surfaces were characterized with both AFM and cyclic voltammetry. Anodic stripping voltammetry of arsenic(III) on the modified electrode was performed. After optimization, a LOD of 0.0096 ppb was obtained with LSV.

Arsenic↗

Fabrication, characterisation and voltammetric studies of gold amalgam nanoparticle modified electrodes.

The tabrication, characterisation, and electroanalytical application of gold and gold amalgam nanoparticles on glassy carbon electrodes is examined. Once the deposition parameters for gold nanoparticle electrodes were optimised, the analytical utility of the electrodes was examined in CrIII electroanalysis. It was found that gold nanoparticle modified (Au-NM) electrodes possess higher sensitivity than gold macroelectrodes. In addition, gold amalgam nanoparticle modified (AuHg-NM) electrodes were fabricated and characterised. The response of those electrodes was recorded in the presence of important environmental analytes (heavy metal cations). It was found AuHg-NM electrodes demonstrate a unique voltammetric behaviour and can be applied for electroanalysis when enhanced sensitivity is crucial.

Carbon↗

Sonoelectroanalysis: investigation of bismuth-film-modified glassy carbon electrodes.

Bismuth-modified glassy carbon electrodes have been investigated for their suitability in sonoelectroanalysis. The stability of the bismuth film to the application of ultrasound was assessed via voltammetric and atomic force microscopy (AFM) studies which revealed little ablation at powers up to an intensity of 130 W cm(-2) delivered from a 25-kHz sonic horn. Furthermore, bismuth-film-modified glassy carbon electrodes were evaluated for the sonoelectroanalytical quantification of zinc and cadmium. Detection limits of 2 x 10(-7) M and 6 x 10(-9) M respectively were found after a 60-s deposition time via an acoustically assisted deposition protocol.

Journal Article↗