PubMed Health⌕ Search

Biomedical subjects

Michael E Moseley

Publications and source records attributed to Michael E Moseley.

At least 19 recordsLinked to original sources

Identifying systematic errors in quantitative dynamic-susceptibility contrast perfusion imaging by high-resolution multi-echo parallel EPI.

Several obstacles usually confound a straightforward perfusion analysis using dynamic-susceptibility contrast-based magnetic resonance imaging (DSC-MRI). In this work, it became possible to eliminate some of these sources of error by combining a multiple gradient-echo technique with parallel imaging (PI): first, the large dynamic range of tracer concentrations could be covered satisfactorily with multiple echo times (TE) which would otherwise result in overestimation of image magnitude in the presence of noise. Second, any bias from T(1) relaxation could be avoided by fitting to the signal magnitude of multiple TEs. Finally, with PI, a good tradeoff can be achieved between number of echoes, brain coverage, temporal resolution and spatial resolution. The latter reduces partial voluming, which could distort calculation of the arterial input function. Having ruled out these sources of error, a 4-fold overestimation of cerebral blood volume and flow remained, which was most likely due to the completely different relaxation mechanisms that are effective in arterial voxels compared with tissue. Hence, the uniform tissue-independent linear dependency of relaxation rate upon tracer concentration, which is usually assumed, must be questioned. Therefore, DSC-MRI requires knowledge of the exact dependency of transverse relaxation rate upon tracer concentration in order to calculate truly quantitative perfusion maps.

Brain↗

Efficient simulation of magnetic resonance imaging with Bloch-Torrey equations using intra-voxel magnetization gradients.

The process of image formation in magnetic resonance imaging (MRI) can be simulated by means of an iterative solution of Bloch-Torrey equations. This is a useful accessory to analyze the influence of sample properties, sequence parameters and hardware specifications on the MRI signal. In this paper, a computer algorithm is presented which is based on calculating partial derivatives of the magnetization vector. This technique allows more efficient simulation than summation of isochromats (the latter being commonly employed for this purpose) and, as a result, the effect of diffusion on the MRI signal can be calculated iteratively. A detailed description of the algorithm is given, and its feasibility for different applications is studied. It is shown that the algorithm is most applicable to simulating the effect of field perturbations, i.e. intra-voxel dephasing, but is also useful for other typical imaging experiments and the simulation of diffusion weighting.

Algorithms↗

Longitudinal changes in white matter following ischemic stroke: a three-year follow-up study.

Information on longitudinal changes in white matter after stroke is limited. The aim of the present study was to quantitatively investigate longitudinal changes in the microstructural integrity of non-lesioned white matter at 1-3 years following ischemic stroke. In a sample of 80 ischemic stroke patients, we obtained diffusion tensor imaging (DTI) measures of fractional anisotropy (FA), an apparent measure of white matter integrity, in radiologically normal-appearing white matter at baseline and 3 years of follow-up. Mixed model regression analysis results showed a significant improvement in FA from baseline during the first 2 years of follow-up that stabilized by the third year of follow-up. These results demonstrate a long-term improvement in apparent white matter integrity following ischemic stroke that continues, at least, into the second year following the insult.

Aged↗

Burning down the brewery: establishing and evacuating an ancient imperial colony at Cerro Baul, Peru.

Before the Inca reigned, two empires held sway over the central Andes from anno Domini 600 to 1000: the Wari empire to the north ruled much of Peru, and Tiwanaku to the south reigned in Bolivia. Face-to-face contact came when both colonized the Moquegua Valley sierra in southern Peru. The state-sponsored Wari incursion, described here, entailed large-scale agrarian reclamation to sustain the occupation of two hills and the adjacent high mesa of Cerro Baúl. Monumental buildings were erected atop the mesa to serve an embassy-like delegation of nobles and attendant personnel that endured for centuries. Final evacuation of the Baúl enclave was accompanied by elaborate ceremonies with brewing, drinking, feasting, vessel smashing, and building burning.

Agriculture↗

High-resolution diffusion-weighted imaging with interleaved variable-density spiral acquisitions.

PURPOSE: To develop a multishot magnetic resonance imaging (MRI) pulse sequence and reconstruction algorithm for diffusion-weighted imaging (DWI) in the brain with submillimeter in-plane resolution. MATERIALS AND METHODS: A self-navigated multishot acquisition technique based on variable-density spiral k-space trajectory design was implemented on clinical MRI scanners. The image reconstruction algorithm takes advantage of the oversampling of the center k-space and uses the densely sampled central portion of the k-space data for both imaging reconstruction and motion correction. The developed DWI technique was tested in an agar gel phantom and three healthy volunteers. RESULTS: Motions result in phase and k-space shifts in the DWI data acquired using multishot spiral acquisitions. With the two-dimensional self-navigator correction, diffusion-weighted images with a resolution of 0.9 x 0.9 x 3 mm3 were successfully obtained using different interleaves ranging from 8-32. The measured apparent diffusion coefficient (ADC) in the homogenous gel phantom was (1.66 +/- 0.09) x 10(-3) mm2/second, which was the same as measured with single-shot methods. The intersubject average ADC from the brain parenchyma of normal adults was (0.91 +/- 0.01) x 10(-3) mm2/second, which was in a good agreement with the reported literature values. CONCLUSION: The self-navigated multishot variable-density spiral acquisition provides a time-efficient approach to acquire high-resolution diffusion-weighted images on a clinical scanner. The reconstruction algorithm based on motion correction in the k-space data is robust, and measured ADC values are accurate and reproducible.

Adult↗

Limitations of apparent diffusion coefficient-based models in characterizing non-gaussian diffusion.

Diffusion in complex heterogeneous structures, for example, the neural fiber system, is non-gaussian. Recently, several methods have been introduced to address the issue of non-gaussian diffusion in multifiber systems. Some are based on apparent diffusion coefficient (ADC) analysis; and some are based on q-space analysis. Here, using a simple mathematic derivation, ADC-based models are shown to be mathematically self-inconsistent in the presence of non-gaussian diffusion. Monte Carlo simulation on restricted diffusion is applied to demonstrate the poor data fitting that can result from ADC-based models. Specific comparisons are performed between two generalized diffusion tensor imaging methods: one of them is based on ADC analysis, and the other is shown to be consistent with q-space formalism. The issue of imaging asymmetric microstructures is also investigated. Signal phase and spin exchange are necessary to resolve multiple orientations of an asymmetric structure.

Anisotropy↗

Simultaneous phase correction and SENSE reconstruction for navigated multi-shot DWI with non-cartesian k-space sampling.

Phase-navigated multi-shot acquisition and parallel imaging are two techniques that have been applied to diffusion-weighted imaging (DWI) to diminish distortions and to enhance spatial resolution. Specifically, sensitivity encoding (SENSE) has been combined with single-shot echo planar imaging (EPI). Thus far, it has been difficult to apply parallel imaging methods, like SENSE, to multi-shot DWI because motion-induced phase error varies from shot to shot and interferes with sensitivity encoding. Although direct phase subtraction methods have been introduced to correct this phase error, they generally are not suitable for SENSE reconstruction, and they cannot remove all the motion artifacts even if the phase error is fully known. Here, an effective algorithm is proposed to correct the motion-induced phase error using an iterative reconstruction. In this proposed conjugate-gradient (CG) algorithm, the phase error is treated as an image encoding function. Given the complex perturbation terms, diffusion-weighted images can be reconstructed using an augmented sensitivity map. The mathematical formulation and image reconstruction procedures of this algorithm are similar to the SENSE reconstruction. By defining a dynamic composite sensitivity, the CG phase correction method can be conveniently incorporated with SENSE reconstruction for the application of multi-shot SENSE DWI. Effective phase correction and multi-shot SENSE DWI (R = 1 to 3) are demonstrated on both simulated and in vivo data acquired with PROPELLER and SNAILS.

Algorithms↗

Foundations of advanced magnetic resonance imaging.

During the past decade, major breakthroughs in magnetic resonance imaging (MRI) quality were made by means of quantum leaps in scanner hardware and pulse sequences. Some advanced MRI techniques have truly revolutionized the detection of disease states and MRI can now-within a few minutes-acquire important quantitative information noninvasively from an individual in any plane or volume at comparatively high resolution. This article provides an overview of the most common advanced MRI methods including diffusion MRI, perfusion MRI, functional MRI, and the strengths and weaknesses of MRI at high magnetic field strengths.

Animals↗

Reduction in levels of matrix metalloproteinases and increased expression of tissue inhibitor of metalloproteinase-2 in response to mild hypothermia therapy in experimental stroke.

OBJECT: Mild hypothermia is a robust neuroprotectant, and the results of prospective clinical trials have indicated that it may improve neurological outcome in certain instances. One aspect of this protection has been associated with the prevention of blood-brain barrier (BBB) disruption. Matrix metalloproteinases (MMPs) have been implicated in BBB disruption because they can degrade the extracellular matrix. In this study the authors explored the relationship between hypothermia and MMPs and whether BBB preservation resulting from mild hypothermia therapy is due to alterations in MMP expression. METHODS: Rats were subjected to middle cerebral artery occlusion for 2 hours; the animals were maintained in a state of normothermia or mild hypothermia (33 degrees C) immediately after the onset of ischemia. The animals' brains were collected 2, 6, and 24 hours after ischemia began. Contrast-enhanced T1-weighted magnetic resonance imaging was performed at 24 hours to assess the extent of BBB disruption. Consistent with prior reports, areas of BBB disruption detected on T1-weighted images were smaller in the brains of rats maintained in a state of hypothermia (normothermia group 8.6 +/- 3% of the brain; hypothermia group 0.2 +/-0.1% of the brain; p < 0.01). Expression of both MMP-2 and MMP-9 at the transcriptional and translational levels was reduced in hypothermic brains at 6 hours and 24 hours after ischemic injury. Matrix metalloproteinase-9 was primarily localized to cells of monocytic origin but was also observed in neurons and astrocytes. Matrix metalloproteinase-2 was found in some neurons and astrocytes but not in inflammatory cells. In addition, hypothermia increased the levels of the endogenous MMP inhibitor, tissue inhibitor of metalloproteinases-2. CONCLUSIONS: The authors conclude that mild hypothermia attenuates BBB disruption, decreases MMP expression, and suppresses MMP activity.

Animals↗

Southern Peru desert shattered by the great 2001 earthquake: implications for paleoseismic and paleo-El Nino-Southern Oscillation records.

In the desert region around the coastal city of Ilo, the great southern Peru earthquake of June 23, 2001 (8.2-8.4 moment magnitude), produced intense and widespread ground-failure effects. These effects included abundant landslides, pervasive ground cracking, microfracturing of surficial hillslope materials, collapse of drainage banks over long stretches, widening of hillside rills, and lengthening of first-order tributary channels. We have coined the term "shattered landscape" to describe the severity of these effects. Long-term consequences of this landscape shattering are inferred to include increased runoff and sediment transport during postearthquake rainstorms. This inference was confirmed during the first minor postearthquake rainstorm there, which occurred in June and July of 2002. Greater amounts of rainfall in this desert region have historically been associated with El Niño events. Previous studies of an unusual paleoflood deposit in this region have concluded that it is the product of El Niño-generated precipitation falling on seismically disturbed landscapes. The effects of the 2001 earthquake and 2002 rainstorm support that conclusion.

Desert Climate↗

Characterizing non-Gaussian diffusion by using generalized diffusion tensors.

Diffusion tensor imaging (DTI) is known to have a limited capability of resolving multiple fiber orientations within one voxel. This is mainly because the probability density function (PDF) for random spin displacement is non-Gaussian in the confining environment of biological tissues and, thus, the modeling of self-diffusion by a second-order tensor breaks down. The statistical property of a non-Gaussian diffusion process is characterized via the higher-order tensor (HOT) coefficients by reconstructing the PDF of the random spin displacement. Those HOT coefficients can be determined by combining a series of complex diffusion-weighted measurements. The signal equation for an MR diffusion experiment was investigated theoretically by generalizing Fick's law to a higher-order partial differential equation (PDE) obtained via Kramers-Moyal expansion. A relationship has been derived between the HOT coefficients of the PDE and the higher-order cumulants of the random spin displacement. Monte-Carlo simulations of diffusion in a restricted environment with different geometrical shapes were performed, and the strengths and weaknesses of both HOT and established diffusion analysis techniques were investigated. The generalized diffusion tensor formalism is capable of accurately resolving the underlying spin displacement for complex geometrical structures, of which neither conventional DTI nor diffusion-weighted imaging at high angular resolution (HARD) is capable. The HOT method helps illuminate some of the restrictions that are characteristic of these other methods. Furthermore, a direct relationship between HOT and q-space is also established.

Anisotropy↗

Self-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging.

A fat-saturated twice-refocused spin echo sequence was implemented on a GE Signa 1.5-T whole-body system for diffusion-weighted imaging. Data were acquired using an analytically designed interleaved variable-density (VD) spiral readout trajectory. This flexible design algorithm allowed real-time prescription on the scanner. Each interleaf of the VD spiral oversampled the center of k-space. The oversampling provided an inherent motion compensation capability. The resultant diffusion-weighted images showed good quality without any retrospective motion correction. An iterated motion correction algorithm was developed to further reduce the signal cancellation artifact caused by motion-induced phase error. In this algorithm, a low-resolution phase map was estimated using the oversampled data in the center of k-space in order to correct for phase error in image space. In vivo diffusion tensor imaging (DTI) studies were performed on the brains of healthy volunteers. High-quality isotropic diffusion-weighted images, trace maps, and FA maps from axial, sagittal, and coronal slices were obtained using a VD spiral readout trajectory with matrix size 256 x 256. To our knowledge, this was also the first time in vivo 512 x 512 DTI results were reported.

Algorithms↗

An MRA study of vascular stenosis in a pig model using CH3-DTPA-Gd (NMS60) and Gd-DTPA.

PURPOSE: This study used an experimental arterial stenosis model in pigs to evaluate the utility of a new medium-weight MRI contrast agent, NMS60 (a synthetic oligomeric Gd complex containing three Gd(3+) atoms, molecular weight of 2158 Da) compared to Gd-DTPA for contrast-enhanced MRA. MATERIALS AND METHODS: We used six male white hybrid pigs. Under anesthesia, one femoral artery was exposed and an inflatable cuff placed around it. The cuff was tightened around the vessel until 80-90% stenosis was achieved using digital subtraction angiography as a guide. Animals were then immediately transferred to the MRI scanner and images acquired pre- and postcontrast injection (0.1 or 0.2 mmol Gd/kg Gd-DTPA or NMS60, as a rapid bolus) using high-resolution and dynamic MRA. RESULTS: The dynamic MRA scans acquired during contrast bolus injection clearly showed the stenosed femoral artery as a segment of close to zero enhancement during the arterial phase of the bolus transit, while on the high-resolution scans the stenosis was difficult to detect due to venous signal contamination. The signal-to-noise at peak enhancement on the dynamic scans was significantly greater with 0.1 mmol Gd/kg NMS60 compared to 0.1 mmol Gd/kg Gd-DTPA (14.6 vs. 9.9, P < .05) and not significantly greater than 0.2 mmol Gd/kg (14.6 vs. 12.8). DISCUSSION AND CONCLUSION: This new medium-weight contrast agent demonstrated significantly greater enhancement than Gd-DTPA and may be valuable to aid detection of vascular stenosis in humans.

Angiography, Digital Subtraction↗

Diffusion-weighted MR imaging in acute ischemia: value of apparent diffusion coefficient and signal intensity thresholds in predicting tissue at risk and final infarct size.

BACKGROUND AND PURPOSE: Identifying tissue at risk for infarction is an important goal of stroke imaging. This study was performed to determine whether pixel-based apparent diffusion coefficient (ADC) and signal intensity ratio are helpful diffusion-weighted (DW) imaging metrics to predict tissue at risk for infarction. METHODS: Twelve patients presenting with acute hemispheric strokes underwent DW imaging within 7 hours of symptom onset. Region of interest (ROI), pixel-based ADC, and signal intensity analyses were performed at initial DW imaging to assess area of infarct growth, final infarct area, and normal tissue. RESULTS: Pixel-based analysis was less accurate than ROI-based analysis for evaluating infarct growth or final infarct with ADC, ADC ratio, and signal intensity ratios. In pixel-based analysis, signal intensity ratios were better than ADCs or ADC ratios for identifying tissue at risk (accuracy, 67.4%) and for predicting final infarct (accuracy, 79.9%). Linear regression analysis demonstrated a strong correlation between lesion volume on quantitative DW images or ADC maps and final infarct volume (P < .001). When receiver operating characteristic (ROC) curves were used to determine optimal cutoffs for ADC and DW image values, the region of infarct growth was significantly correlated with only the mismatch between initial qualitative DW image and quantitative DW image signal intensity ratio (cutoff value, 1.19; R = 0.652; P = .022). CONCLUSION: Pixel-based thresholds applied to ADC or DW image signal intensity maps were not accurate prognostic measures of tissue at risk. Quantitative DW images or ADC maps may provide added information not obtained by visual inspection of the qualitative DW image map.

Acute Disease↗

Influence of arterial input function on hypoperfusion volumes measured with perfusion-weighted imaging.

BACKGROUND AND PURPOSE: The arterial input function (AIF) is critical in determining hemodynamic parameters quantitatively with bolus-tracking MRI. We studied the effect of varying the location of measurement of AIF on the volume of hypoperfusion. We compared the volumes of hypoperfusion obtained with different AIFs with the final ischemic lesion volume. METHODS: We included 13 patients with acute cerebral ischemia in the anterior circulation who underwent diffusion- (DWI) and perfusion (PWI)-weighted imaging within 8 hours after symptom onset and exhibited DWI lesion expansion between baseline and follow-up. AIF was measured at 4 locations: near both middle cerebral arteries (MCAs), in MCA branches adjacent to the largest DWI abnormality, and at the same level on the opposite hemisphere. Hypoperfusion lesion volumes were compared with the DWI volume at follow-up. RESULTS: Large variations in PWI lesion size were found with different AIF locations. The largest PWI lesions were found when AIF was measured at the contralateral MCA. Smaller PWI lesions were found when AIF was measured in the other locations. There was no significant difference between PWI lesion area at baseline and follow-up DWI lesion when AIF was measured at the contralateral MCA. The other PWI lesions significantly underestimated follow-up DWI lesion size. CONCLUSIONS: AIF is an important determinant of the size of hypoperfusion lesions measured with PWI. PWI lesion volumes determined with AIF from the contralateral MCA are associated with follow-up lesion volume.

Acute Disease↗

Single breath-hold diffusion-weighted imaging of the abdomen.

PURPOSE: To generate high quality diffusion-weighted images (DWI) and corresponding isotropic ADC maps of the abdomen with full organ (kidneys) coverage in a single breath-hold. MATERIALS AND METHODS: DWI was performed in 12 healthy subjects with an asymmetric, spin-echo, single-shot EPI readout on a system with high performance gradients (40 mT/minute). The isotropic diffusion coefficient was measured from maps and SNR was determined for both diffusion-weighted and reference images in the liver, spleen, pancreas, and kidneys. In six patients, single-axis diffusion encoding along three orthogonal axes (12 NEX) was employed to assess anisotropic diffusion in kidneys. RESULTS: This technique yielded images of quality and resolution which compares favorably to that of prior work. SNR ranged from 27.0 in liver to 44.1 in kidneys for the diffusion-weighted images, and from 19.6 in liver to 39.0 in kidneys in reference images. ADCs obtained in the renal medulla, renal cortex, liver, spleen, and pancreas were (2091 +/- 55) x 10(-6), (2580 +/- 53) x 10(-6), (1697 +/- 52) x 10(-6), (1047 +/- 82) x 10(-6), and (2605 +/- 168) x 10(-6) mm(2)/second, respectively (mean +/- SE). Apparent diffusion coefficient (ADC) in the renal medulla and cortex were significantly different by paired t-test (P = 4.22 x 10(-10)). Renal medulla and cortex yielded anisotropy indices (AI) of 0.129 and 0.067, respectively. CONCLUSIONS: 1) Single-shot SE EPI DWI in the abdomen with this technique provides high quality images and maps with full organ coverage in a single breath-hold; 2) ADCs obtained in the renal medulla and cortex are significantly different; and 3) diffusion within the renal medulla is moderately anisotropic.

Abdomen↗

In vivo MR tractography using diffusion imaging.

Diffusion in structured tissue, such as white matter or muscle, is anisotropic. MR diffusion tensor imaging (DTI) measures anisotropy per pixel and provides the directional information relevant for MR tractography or fiber tracking in vivo. MR tractography is non-invasive, relatively fast, and can be repeated multiple times without destructing important tissue. Moreover, the combination with other MR images is relatively simple. In this paper, the basic principles of tractography are presented. Different tracking methods with varying degrees of complexity are introduced and their potential strengths and weaknesses are discussed. Clinical applications and different strategies for evaluating the fidelity of tracking results are reviewed.

Anisotropy↗

Line scan diffusion imaging of the spine.

BACKGROUND AND PURPOSE: Recent findings suggest that diffusion-weighted imaging might be an important adjunct to the diagnostic workup of disease processes in the spine, but physiological motion and the challenging magnetic environment make it difficult to perform reliable quantitative diffusion measurements. Multi-section line scan diffusion imaging of the spine was implemented and evaluated to provide quantitative diffusion measurements of vertebral bodies and intervertebral disks. METHODS: Line scan diffusion imaging of 12 healthy study participants and three patients with benign vertebral compression fractures was performed to assess the potential of line scan diffusion imaging of the spinal column. In a subgroup of six participants, multiple b-value (5-3005 s/mm(2)) images were obtained to test for multi-exponential signal decay. RESULTS: All images were diagnostic and of high quality. Mean diffusion values were (230 +/- 83) x 10(-6) mm(2)/s in the vertebral bodies, (1645 +/- 213) x 10(-6) mm(2)/s in the nuclei pulposi, (837 +/- 318) x 10(-6) mm(2)/s in the annuli fibrosi and ranged from 1019 x 10(-6) mm(2)/s to 1972 x 10(-6) mm(2)/s in benign compression fractures. The mean relative intra-participant variation of mean diffusivity among different vertebral segments (T10-L5) was 2.97%, whereas the relative difference in mean diffusivity among participants was 7.41% (P <.0001). The estimated measurement precision was <2%. A bi-exponential diffusion attenuation was found only in vertebral bodies. CONCLUSION: Line scan diffusion imaging is a robust and reliable method for imaging the spinal column. It does not suffer as strongly from susceptibility artifacts as does echo-planar imaging and is less susceptible to patient motion than are other multi-shot techniques. The different contributions from the water and fat fractions need to be considered in diffusion-weighted imaging of the vertebral bodies.

Adult↗