Mechanism of diastolic mitral regurgitation in candidates for cardiac resynchronization therapy.

It was hypothesized that restricted diastolic leaflet motion is implicated not only in the mechanism of systolic mitral regurgitation (MR) but also in the mechanism of diastolic MR observed in patients with severe heart failure. Cardiac resynchronization therapy (CRT) can oppose increased mitral leaflet tethering by increasing transmitral pressure, thereby providing an opportunity to explore this hypothesis. A total of 26 consecutive candidates for CRT with diastolic MR were compared with 26 candidates without diastolic MR. Maximal diastolic mitral leaflet opening and inflow direction and measures of mitral valve apparatus (i.e., mitral annular diameters, calculated mitral annular area, and tethering distance) were assessed from the apical 4-chamber view before and during CRT. There were no significant differences in New York Heart Association functional class, ejection fraction, QRS duration, PR interval, systolic MR grade, or 2-dimensional geometry of the mitral valve apparatus between the groups. Patients with diastolic MR had more restricted maximal diastolic leaflet openings (54 degrees +/- 17 degrees vs 71 degrees +/- 11 degrees , p = 0.003) and substantially smaller inflow angles (66 degrees +/- 7 degrees vs 79 degrees +/- 9 degrees , p = 0.0003) compared with patients without diastolic MR. After the institution of CRT, diastolic MR was eliminated in all patients, although there were no significant changes in any of the parameters of mitral valve apparatus. In conclusion, abnormal mitral valve tethering is a constitutive element of the mechanism of diastolic MR in patients with left ventricular dysfunction. Its acute resolution after CRT does not seem to be caused by changes in mitral valve geometry but rather by an increase in transmitral closing forces.

Cardiac Pacing, Artificial↗

Clinical surveillance of a tined, bipolar, silicone-insulated ventricular pacing lead.

AIMS: This study assesses short- and long-term performance of the S80TB ventricular lead manufactured by Sorin Biomedica, Italy. METHODS AND RESULTS: Three hundred and thirty leads were implanted and had complete follow-up with us for a minimum of 60 months or up to failure, removal, and/or patient death (mean 40 months, range: 1 day to 81 months). Thirty-two patients (9.6%) had spontaneous lead-related complications: 7 (2.1%) occurred during the first week; 25 (7.6%) had chronic complications, of which 20 (6.1%) necessitated re-operations; 3 (0.9%) were lead material failures. Of the 110 re-operations (90 pacemaker replacements and 20 operations due to complications), 7 additional cases (6.4%) were complicated by unique connector damage that occurred during disconnection of the lead from the connector block. The Kaplan-Meier estimated 5-year lead survival free of lead material failure and free of any significant lead complication were 97.9 and 87%, respectively. CONCLUSION: The S80TB lead demonstrates an acceptable rate of acute and chronic spontaneous complications and very few lead material failures over 5 years of follow-up. However, there seems to be a relatively high incidence of connector damage during disconnection from the connector block. Extra caution is required during those procedures in patients with this lead.

Adult↗

Improvement of congestive heart failure by upgrading of conventional to resynchronization pacemakers.

AIMS: To compare the clinical response of patients with right ventricular apical pacing (RVAP) upgraded to cardiac resynchronization therapy (CRT) to that of previously nonpaced heart failure (HF) patients who had de novo CRT implantation. BACKGROUND: The role of CRT in patients with wide QRS and HF due to RVAP is less well established than in other CRT candidates. METHODS: Ninety-eight consecutive patients with CRT were studied (mean age 70, mean ejection fraction 0.23). Group A: patients having RVAP prior to CRT implantation (n = 25), group B: patients without prior RVAP (n = 73). Clinical and echocardiographic parameters were recorded prior to, and 3 months after, CRT implantation. RESULTS: Group A patients had a wider QRS at baseline compared to group B (203 +/- 32 ms vs 163 +/- 30 ms respectively, P < 0.001), and a shorter 6-minute walking distance (222 +/- 118 m vs 362 +/- 119 m, respectively, P < 0.005). Otherwise, clinical and echocardiographic parameters were not different. At follow up, group A patients had an average 0.7 +/- 0.5 decrease in their NYHA functional class, compared to 0.3 +/- 0.7 in group B patients (P < 0.05). Six-minute walking distance increased by 93 +/- 113 m in group A, versus 36 +/- 120 m in group B (P = 0.22). There was no difference in echocardiographic response to CRT between the groups. CONCLUSIONS: HF patients with prior RVAP demonstrate clinical improvement after upgrading to CRT that is comparable, and in some aspects, even better than that observed in HF patients with native conduction delay who undergo de novo CRT implantation.

Aged↗

Radiofrequency ablation of atrioventricular nodal reentry tachycardia: a 14 year experience with 901 patients at the Tel Aviv Sourasky Medical Center.

BACKGROUND: Atrioventricular nodal reentry tachycardia is the most frequent cause of regular, paroxysmal supraventricular tachycardia. Radiofrequency ablation of the slow pathway has been recommended as first-line therapy for curing AVNRT. OBJECTIVES: To report a 14 year experience of RFA of the slow pathway in patients with AVNRT treated in our laboratory. METHODS: A total of 901 consecutive patients (aged 9-92, mean 50.8 +/- 18.2 years) underwent RFA of the slow pathway. All patients had sustained AVNRT induced with or without intravenous administration of isoproterenol. A standard electrophysiologic method with three diagnostic and one ablation catheter was used in 317 patients (35.2%); in the remaining 584 patients (64.8%), only two electrode catheters (one diagnostic, one ablation) were used ("two-catheter approach"). RESULTS: Catheter ablation of the slow pathway abolished AVNRT induction in 877 patients (97.3%). In 14 patients (1.6%) the procedure was discontinued while in 10 (1.1%) the procedure failed. In 864 patients (95.9%) there were no complications. Transient or permanent AV block occurred during the procedure in 31 patients (3.4%), of whom 8 (0.9%) eventually required pacemaker insertion (n = 7) or upgrade of a previously implanted WI pacemaker (n = 1) during the month following the procedure. The number of catheters used did not significantly affect the rate of results or complications of the ablation procedure. The success and complication rates remained stable over the years, although a significant trend for increased age and associated heart disease was observed during the study period. CONCLUSIONS: The results of this single-center large study, which included patients with a wide age range, showed results similar to those of previous studies. The use of a "two-catheter approach" (one diagnostic and one ablation) was as effective and safe as a multi-catheter approach.

Adolescent↗

Atrial fibrillation in dobutamine stress echocardiography.

OBJECTIVES: To describe the incidence of atrial fibrillation induced by dobutamine stress echocardiography and characterize patients at risk of developing atrial fibrillation, by constructing a simple validated risk score index. DESIGN: An observational study using prospectively collected data. METHODS: 3800 consecutive patients in sinus rhythm undergoing dobutamine stress echocardiography were randomly divided to a case (2/3) and test group (1/3). Associations of predetermined demographic, clinical, electrocardiographic and echocardiographic variables were calculated in patients with and without atrial fibrillation induced by dobutamine stress echocardiography in the case group. Logistic regression analysis determined significant independent risk predictors, a scoring index was constructed and validated on the test group. RESULTS: There was a 2% incidence of dobutamine stress echocardiography-induced atrial fibrillation in the study population. Risk predictors of atrial fibrillation included: a history of atrial fibrillation (2 points), increased left atrial diameter, right bundle branch block, decreased rest heart rate and hypertension (1 point each). The case subgroup low-risk patients (score 0-2) had a 1% risk, moderate-risk patients (score 3) a 2.7% and high-risk patients (score 4-6) a 14.5% risk of developing atrial fibrillation during dobutamine stress echocardiography. The rates in the test subgroup were 1%, 3.8% and 15.3%, respectively. CONCLUSION: Atrial fibrillation during dobutamine stress echocardiography is not common, the risk of developing atrial fibrillation during dobutamine stress echocardiography can be predicted by using a simple risk score system comprised of clinical, electrocardiographic and rest echocardiographic variables, which may be of help when planning a dobutamine stress echocardiography test in selected cases.

Aged↗

Physical determinants of systolic murmur intensity in aortic stenosis.

We investigated which physical parameter has the greatest impact on the perceived loudness of a systolic murmur in aortic stenosis. Loudness of murmur in aortic stenosis correlated best with peak momentum transfer--and thus with body size--so that loud murmurs predict severe disease less reliably in larger patients.

Aged↗

Prior exercise training improves the outcome of acute myocardial infarction in the rat. Heart structure, function, and gene expression.

OBJECTIVES: The aim of this research was to investigate the structural, functional, and molecular features of the remodeling heart in prior swim-trained infarcted rats. BACKGROUND: Physical exercise training is a known protective factor against cardiovascular morbidity and mortality. The structural and molecular aspects underlying this protection in the remodeling heart have not been investigated. METHODS: After seven weeks of swimming exercise training, rats underwent surgical ligation of the left coronary artery followed by a four-week sedentary period. Untrained control rats underwent the same surgical protocol. Left ventricular function was assessed by echocardiography four weeks after infarction, and hearts were sampled for histological and molecular analysis. Ribonucleic acid from the surviving left ventricle was analyzed by complementary deoxyribonucleic acid arrays followed by Northern blotting or quantitative reverse transcription polymerase chain reaction of selected messenger ribonucleic acids (mRNAs). RESULTS: Scar area was 1.6-fold smaller (p = 0.0002), arteriolar density was 1.7-fold higher (p = 0.0002), and left ventricular shortening fraction was 1.9-fold higher (p = 0.003) in the exercise-trained compared with sedentary hearts. Eleven genes whose expression level varied by at least +/-1.5-fold distinguished the prior exercised rats from their sedentary counterparts. Compared with sedentary, the exercised hearts displayed 9- and 2.4-times lower levels of atrial natriuretic peptide and aldolase mRNA (p = 0.03 and 0.04, respectively), and a 2.7- and 1.9-fold higher abundance of cytochrome c-oxidase and fatty acid binding protein, respectively (p < 0.03, each). CONCLUSIONS: Swimming exercise training before acute myocardial infarction reduces scar size, increases arteriole density, and manifests adaptation of stress- and energy-metabolism-related genes that may contribute to the improved heart function observed during remodeling.

Adenosine Triphosphatases↗

Association of intentional changes in body weight with coronary heart disease event rates in overweight subjects who have an additional coronary risk factor.

Despite evidence that weight loss improves the severity of coronary heart disease (CHD) risk factors, a direct association between weight loss and CHD incidence has not been demonstrated. In 1994-2001, the authors conducted an observational study of intentional weight loss as related to CHD incidence among patients recruited from a network of clinics in Israel who received nutritional counseling from a dietitian to support the medical recommendation to lose weight. Subjects were outpatients aged 50-75 years with a body mass index of > or =27 kg/m(2), without CHD or cancer but with at least one risk factor for CHD in addition to overweight. Outcomes were documented over 4 years by repeated weight measurements and by medical record verification. Among 1,669 patients, 224 (13.4%) incidents of CHD were recorded. For subjects who underwent at least 6 months of dietetic counseling, the risk-factor-adjusted odds ratio for CHD incidence associated with a weight loss of 4.5 kg (the median level of weight loss) was 0.57 (95% confidence interval: 0.39, 0.84). In this, the largest known study of its type reported to date, intentional weight loss from a 6-month diet predicted lower incidence of CHD over 4 years.

Aged↗

Impact of left ventricular filling properties on the benefit of exercise training in patients with advanced chronic heart failure secondary to ischemic or nonischemic cardiomyopathy.

This study examined left ventricular (LV) filling properties and exercise hemodynamics noninvasively before and after an exercise training program in patients with chronic heart failure (HF). Although exercise training did not improve LV filling properties in patients with advanced HF, LV filling properties determined the hemodynamic benefit attainable from exercise in this patient group.

Chronic Disease↗

Long-term performance of screw-in atrial pacing leads: a randomized comparison of J-shaped and straight leads.

OBJECTIVE: In this prospective, randomized, control study we compared performance of J-shaped (JL) and straight atrial leads (SL) with active (screw-in) fixation mechanism, over a 5-year follow-up period. SUBJECTS AND METHODS: A total of 208 consecutive patients were randomized for implantation with a Medtronic 4568 JL model (n = 103) versus a Medtronic 4068 SL model (n = 105), and all lead-related measurements and complications were recorded. RESULTS: Lead-related complications occurred in JL and SL with similar frequency (6% and 9%, respectively, P = 0.45). Lead dislodgment occurred in 8 (7.8%) cases in SL versus none in JL (P = 0.004). Lead malfunction and excessive pacing thresholds without macrodislodgment occurred more frequently in JL (11; 10.7%) than in SL (4; 3.8%), P = 0.055. Lead material failure (insulation break) occurred only once in SL at the 5-year checkup. Most complications occurred during the first year after implantation. Other events occurred in both leads with similar frequency and included: death in 39 and 35, loss of follow-up in 8 and 6, and development of atrial fibrillation in 9 and 15 patients, respectively. Of those who completed follow-up, lead impedance and pacing threshold increased significantly in both groups. P wave decreased in SL but not in JL. CONCLUSION: More dislocations occurred in SL, but were counterbalanced by more lead malfunctions and excessive pacing thresholds in the JL group. Both leads demonstrated minor deterioration in electrical measurements during follow-up, with only 1 case of lead material failure in SL. Overall, both groups demonstrated favorable lead performance throughout follow-up.

Aged↗

Programmable multiple pacing configurations help to overcome high left ventricular pacing thresholds and avoid phrenic nerve stimulation.

BACKGROUND: High left ventricular pacing (LVP) thresholds and phrenic nerve stimulation (PNS) are common problems with cardiac resynchronization (CRT). Newer systems capable of multiple LVP configurations may help overcome these problems without the need for reoperation. METHODS: CRT systems capable of multiple LVP configurations (Guidant models H155 and H145) were implanted in 43 patients (study group). An additional 49 patients (control group) received CRT systems (Guidant, Medtronic, Biotronik, St. Jude Medical, various models) lacking this feature. RESULTS: Overall, acute high (> or =2.5 V/0.5 ms) LVP thresholds were encountered in 13 (30%) of the study group, and 25 (50%) of control group patients (P = 0.03). PNS was encountered in 5 (12%) of the study group and 12 (24%) of control group patients (P = 0.13). All cases of high LVP thresholds and PNS in the study group were managed by switching to a different LVP configuration, while high thresholds remained in control group patients, and PNS was managed by replacing the lead. The CS lead was successfully placed in a lateral branch in 95% of study group, compared to only 77% of control group patients (P = 0.004). CONCLUSIONS: Multiple LVP configurations were clinically useful in a significant number of patients undergoing CRT system implantation by helping to overcome high LVP thresholds and PNS, and by providing more flexibility in placing the LV lead.

Aged↗

Upper limit of vulnerability determination during implantable cardioverter-defibrillator placement to minimize ventricular fibrillation inductions.

The defibrillation threshold (DFT) and upper limit of vulnerability (ULV) were determined using step-down protocols in 50 patients who underwent implantable cardioverter-defibrillator placement or testing. The sensitivity and specificity of each ULV energy level was assessed for detecting an increased DFT, correlation of the DFT and ULV, and optimal shock timing for ULV determination. A ULV <10 or 11 J (failure to induce ventricular fibrillation with 10- to 11-J shocks) was 100% predictive of an acceptable DFT and may be sufficient to exclude unacceptable DFTs in 60% of implantable cardioverter-defibrillator recipients. All 4 shocks used to scan the peak of the T wave during ULV testing were necessary for accurate ULV determination.

Aged↗

Association of left ventricular filling parameters assessed by pulsed wave Doppler and color M-mode Doppler echocardiography with left ventricular pathology, pulmonary congestion, and left ventricular end-diastolic pressure.

Among 90 consecutive patients with various degrees of left ventricular (LV) dysfunction (normal patients, LV hypertrophy, LV ejection fraction <50%, and <30%), the mitral valve pulse-wave E/A ratio showed a characteristic U-shaped curve with increasing severity of LV dysfunction. In contrast, there was a significant progressive decrease in flow propagation velocity of the E-wave (Vp) and a significant increase in E/Vp values with increasing severity of LV dysfunction. The E/Vp ratio was the best predictor of pulmonary congestion, and in a subgroup of patients who underwent cardiac catheterization, it was the only significant predictor of LV end-diastolic pressure.

Adolescent↗

Long-term prognostic significance of left atrial volume in acute myocardial infarction.

OBJECTIVES: The aim of this study was to evaluate the significance of increased left atrial (LA) volume determined within the first 48 h of admission as a long-term predictor of outcome in patients with acute myocardial infarction (MI). BACKGROUND: The LA volume reflects left ventricular (LV) diastolic properties. Whereas other LV Doppler diastolic characteristics are influenced by acute changes in LV function, LA volume is stable and reflects diastolic properties before MI. METHODS: Clinical and echocardiographic parameters were prospectively collected in 395 consecutive patients with acute MI. Patients with LA volume index (LAVI) >32 ml/m(2) (normal + 2 standard deviations) were compared with those with LAVI <==32 ml/m(2). Independent clinical and echocardiographic prognostic risk factors for five years' mortality were determined by the Cox proportional hazard model. RESULTS: Left atrial volume index >32 ml/m(2) was found in 63 patients (19%) who had a higher incidence of congestive heart failure on admission (24% vs. 12%, p < 0.01), a higher incidence of mitral regurgitation, increased LV dimensions, and reduced LV ejection fraction when compared with patients with LAVI <==32 ml/m(2). Their five-year mortality rate was 34.5% versus 14.2% (p < 0.001). Significant independent risk predictors of five years' mortality were age (10 years) (odds ratio [OR] 1.45; 95% confidence interval [CI]1.14 to 1.86), Killip class >/=2 on admission (OR 2.30; 95% CI 1.29 to 4.09), LAVI >32 ml/m(2) (OR 2.22; 95% CI 1.25 to 3.96), diabetes (OR 1.94; 95% CI 1.15 to 3.28), and LV restrictive filling pattern (OR 1.89; 95% CI 1.09 to 3.31). CONCLUSIONS: In patients with acute MI, increased LA volume, determined within the first 48 h of admission, is an independent predictor of five-year mortality with incremental prognostic information to clinical and echocardiographic data.

Aged↗

A novel form of familial bidirectional ventricular tachycardia.

We evaluated a family with 30 members, 3 of whom had incessant polymorphous and bidirectional ventricular tachycardia (VT) that was electrocardiographically similar to that described in other familial polymorphic VT series; the VT was unrelated to exercise and asymptomatic. More subtle, but morphologically similar, ventricular arrhythmias were detected in 3 other family members. Genes related to intracellular calcium transport were specifically excluded.

Adult↗

Long-term outcome of patients who received implantable cardioverter defibrillators for stable ventricular tachycardia.

INTRODUCTION: Evidence is inconclusive concerning the role of implantable cardioverter defibrillators (ICDs) to treat patients with hemodynamically stable ventricular tachycardia (VT). The goal of this study was to estimate future risk of unstable ventricular arrhythmias in patients who received ICDs for stable VT. METHODS AND RESULTS: We reviewed complete ICD follow-up data from 82 patients (age 66.1 +/- 11.3 years; left ventricular ejection fraction 32.3%+/- 11.2%; mean +/- SD) who received ICDs for stable VT. During the follow-up period of 23.6 +/- 21.5 months (mean +/- SD), 15 patients (18%) died, and 10 (12%) developed unstable ventricular arrhythmia, 8 of whom had the unstable arrhythmia as the first arrhythmia after ICD placement. Estimated 2- and 4-year survival in the whole group was 80% and 74%, respectively. Estimated 2- and 4-year probability of any VT and unstable VT was 67% and 77% and 11% and 25%, respectively. There were no differences in age, ejection fraction, sex, underlying heart disease, cycle length, symptoms, baseline electrophysiologic study results, or QRS characteristics of qualifying VT between patients who developed unstable ventricular arrhythmia and patients who did not. Twenty-nine patients (35%) had at least one inappropriate shock, and 11 (13%) underwent further surgery for ICD-related complications. CONCLUSION: Patients who present with hemodynamically stable VT are at risk for subsequent unstable VT. ICD treatment offers potential salvage of patients with stable VT who subsequently develop unstable VT/ventricular fibrillation, although complications and inappropriate shocks are considerable. No predictors could be found for high and low risk for unstable arrhythmias. These findings support ICD treatment for stable VT survivors.

Aged↗

A missense mutation in CASQ2 is associated with autosomal recessive catecholamine-induced polymorphic ventricular tachycardia in Bedouin families from Israel.

Catecholamine-induced polymorphic ventricular tachycardia (CPVT) is characterized by episodes of syncope, seizures or sudden death, in response to physical activity or emotional stress, and affects mainly young children with morphologically normal hearts. We have recently described an autosomal recessive form of the disorder in seven families from a Bedouin tribe in the north of Israel, and mapped the disease-causing gene to chromosome 1p13-1p21. Direct sequencing of the calsequestrin 2 (CASQ2), a candidate gene from within the linkage interval, revealed a negatively charged aspartic acid change to a positively charged histidine at position 307 of the protein. CASQ2 serves as the major calcium reservoir within cardiac myocytes. This mutation occurs in a highly conserved residue of the protein. The implication of the calcium release cascade in this disease, may lead to a better understanding of the pathophysiologic events underlying ventricular tachycardia, and to the use of drugs directly involved in intracellular calcium control for the treatment of the CPVT patients.

Adolescent↗

Use of automatic threshold tracking function with non-low polarization leads: risk for algorithm malfunction.

The AutoCapture (AC) function of new pacemakers (PM) from St Jude Medical (SJM) was originally recommended for use with low polarization (LP) ventricular leads only.However, recent reports have encouraged the use of the AC function with various leads, including those lacking a special LP design. The objective of this study was to analyze the reliability and safety of the AC algorithm application with different types of pacing leads. The study group comprised 30 consecutive patients with AC PMs connected to three different types of non-LP leads. Ten patients with SJM LP leads served as the control group. The study protocol included a complete AC function test using four different pulse widths (PW). The pacing threshold was independently assessed by a manual/semiautomatic check. Erratic behavior of polarization measurements with increasing PWs was demonstrated in 43% (n = 13) of the study group. Invalid polarization measurements resulted in erroneous algorithm recommendation to apply AC function in 17% (n = 5) of the study patients. Subsequent AC function activation lead to incorrect threshold determination due to missed noncapture in three patients. AC function should be applied with caution with non-LP leads. "Off label" use of these leads may cause erroneous polarization signal measurements which, in some cases, may result in incorrect pacing threshold determination, rendering a potential risk to dependent patients.

Algorithms↗