An ultrasound research interface for a clinical system.

Under a contract with the National Cancer Institute, we have developed a research interface to an ultrasound system. This ultrasound research interface (URI) is an optional feature providing several basic capabilities not normally available on a clinical scanner. The URI can store high-quality beamformed radio-frequency data to file for off-line processing. Also, through an integrated user interface, the user is provided additional control over the B-mode receive aperture and color flow ensemble size. A third major capability is the ability to record and playback macro files. In this paper, we describe the URI and illustrate its use on three research examples: elastography, computed tomography, and spatial compounding.

Biomedical Research↗

Observer efficiency in discrimination tasks simulating malignant and benign breast lesions imaged with ultrasound.

We investigate and extend the ideal observer methodology developed by Smith and Wagner to detection and discrimination tasks related to breast sonography. We provide a numerical approach for evaluating the ideal observer acting on radio frequency (RF) frame data, which involves inversion of large nonstationary covariance matrices, and we describe a power-series approach to computing this inverse. Considering a truncated power series suggests that the RF data be Wiener-filtered before forming the final envelope image. We have compared human performance for Wiener-filtered and conventional B-mode envelope images using psychophysical studies for 5 tasks related to breast cancer classification. We find significant improvements in visual detection and discrimination efficiency in four of these five tasks. We also use the Smith-Wagner approach to distinguish between human and processing inefficiencies, and find that generally the principle limitation comes from the information lost in computing the final envelope image.

Algorithms↗

An ultrasound research interface for a clinical system.

Under a contract with the National Cancer Institute, we have developed a research interface to an ultrasound system. This ultrasound research interface (URI) is an optional feature providing several basic capabilities not normally available on a clinical scanner. The URI can store high-quality beamformed radio-frequency data to file for off-line processing. Also, through an integrated user interface, the user is provided additional control over the B-mode receive aperture and color flow ensemble size. A third major capability is the ability to record and playback macro files. In this paper, we describe the URI and illustrate its use on three research examples: elastography, computed tomography, and spatial compounding.

Biomedical Research↗

Optimizing multicompression approaches to elasticity imaging.

Breast lesion visibility in static strain imaging ultimately is noise limited. When correlation and related techniques are applied to estimate local displacements between two echo frames recorded before and after a small deformation, target contrast increases linearly with the amount of deformation applied. However, above some deformation threshold, decorrelation noise increases more than contrast such that lesion visibility is severely reduced. Multicompression methods avoid this problem by accumulating displacements from many small deformations to provide the same net increase in lesion contrast as one large deformation but with minimal decorrelation noise. Unfortunately, multicompression approaches accumulate echo noise (electronic and sampling) with each deformation step as contrast builds so that lesion visibility can be reduced again if the applied deformation increment is too small. This paper uses signal models and analysis techniques to develop multicompression strategies that minimize strain image noise. The analysis predicts that displacement variance is minimal in elastically homogeneous media when the applied strain increment is 0.0035. Predictions are verified experimentally with gelatin phantoms. For in vivo breast imaging, a strain increment as low as 0.0015 is recommended for minimum noise because of the greater elastic heterogeneity of breast tissue.

Algorithms↗

Efficient array beam forming by spatial filtering for ultrasound B-mode imaging.

This paper proposes an efficient array beam-forming method using spatial matched filtering (SMF) for ultrasonic imaging. In the proposed method, ultrasonic waves are transmitted from an array subaperture with fixed transmit focus as in conventional array imaging. At receive, radio frequency echo signals from each receive channel are passed through a spatial matched filter that is constructed based on the system transmit-receive spatial impulse response. The filtered echo signals are then summed without time delays. The filter concentrates and spatially registers the echo energy from each element so that the pulse-echo impulse response of the summed output is focused with acceptably low side lobes. Analytical beam pattern analysis and simulation results using a linear array show that this spatial filtering method can improve lateral resolution and contrast-to-noise ratio as compared with conventional dynamic receive focusing (DRF) methods. Experimental results with a linear array are consistent but point out the need to address additional practical issues. Spatial filtering is equivalent to synthetic aperture methods that dynamically focus on both transmit and receive throughout the field of view. In one common example of phase aberrations, the SMF method was degraded to a degree comparable to conventional DRF methods.

Computer Simulation↗

Modeling and phantom studies of ultrasonic wall shear rate measurements using coded pulse excitation.

Wall shear rate (WSR) is the derivative of blood velocity with respect to vessel radius at the endothelial cell (EC) surface. The product of WSR and blood viscosity is the wall shear stress (WSS) that has been identified as an important factor for atherosclerosis development. High echo signal-to-noise ratio (eSNR) and high spatial resolution are crucial for minimizing the errors in WSR estimates. By transmitting coded pulses with time-bandwidth product greater than one, high eSNR from weak blood scatter can be achieved without increasing instantaneous power or sacrificing spatial resolution. This paper summarizes a series of measurements in a straight tube (5-mm diameter), constant velocity flow phantom using a 10 MHz transducer (60% bandwidth, f/1.5) imaged with a 72 degrees Doppler angle, 125 MHz sampling frequency and 1 kHz pulse repetition frequency. Measurements were made using a frequency-modulated (FM) code, phase-modulated (PM) codes, and uncoded broadband and narrow band pulse transmissions. Both simulation and experimental results show that coded-pulse excitation increases accuracy and precision in WSR estimation for laminar flow over a broad range of peak velocity values when compared to standard pulsing techniques in noise-limited conditions (eSNR < 30 dB). The code sequence and its length are selected to balance range lobe suppression with eSNR and echo coherence enhancements to minimize WSR errors. In our study, the combination of an eight bit Optimal coded pulse with a Wiener compression filter yielded the highest WSR estimation performance.

Animals↗

Thyroid gland tumor diagnosis at US elastography.

PURPOSE: To prospectively evaluate the elastographic appearance of thyroid gland tumors and explore the potential sensitivity and specificity of ultrasonographic (US) elastography for differentiating benign and malignant tumors, with histopathologic analysis as the reference standard. MATERIALS AND METHODS: The study was institutional review board approved, and each patient gave written informed consent. Fifty-two thyroid gland lesions (22 malignant, 30 benign) in 31 consecutive patients (six men, 25 women; mean age, 49.7 years +/- 14.7 [standard deviation]) were examined with real-time elastography in the elasticity imaging mode implemented on a clinical US scanner modified for research. In addition, the radiofrequency echo data stored during US were exported from the scanner and used for off-line strain image reconstruction. All elastograms were evaluated for the lesion visibility, relative brightness, and margin regularity and definition by using a four-point scale. In addition, normal thyroid gland tissue and thyroid gland tumor strains were measured on off-line processed elastograms, and the thyroid gland-to-tumor strain ratio (ie, strain index) was calculated. The potential of elastographic criteria for the diagnosis of thyroid gland cancer was evaluated with univariate analysis and multivariate logistic regression. Qualitative variables were compared by using the chi2 test, and quantitative variables were compared by using the Mann-Whitney U test. P < .05 was considered to indicate significance. RESULTS: A strain index value greater than 4 on off-line processed elastograms was the strongest independent predictor of thyroid gland malignancy (P < .001); this criterion had 96% specificity and 82% sensitivity. Two other elastographic criteria, which were evaluated on real-time elastograms--a margin regularity score higher than 3 (88% specificity, 36% sensitivity) and a tumor area ratio higher than 1 (92% specificity, 46% sensitivity)--also were associated with malignancy (P < .05). However, the usefulness of these criteria was not considered to be high because of their low sensitivity. CONCLUSION: Elastography is a promising imaging technique that can assist in the differential diagnosis of thyroid cancer.

Adult↗

Detection performance theory for ultrasound imaging systems.

A rigorous statistical theory for characterizing the performance of medical ultrasound systems for lesion detection tasks is developed. A design strategy for optimizing ultrasound systems should be to adjust parameters for maximum information content, which is obtained by maximizing the ideal observer performance. Then, given the radio-frequency data, image and signal processing algorithms are designed to extract as much diagnostically relevant information as possible. In this paper, closed-form and low-contrast approximations of ideal observer performance are derived for signal known statistically detection tasks. The accuracy of the approximations are tested by comparing with Monte Carlo techniques. A metric borrowed and modified from photon imaging, Generalized Noise Equivalent Quanta, is shown to be a useful and measurable target-independent figure of merit when adapted for ultrasound systems. This theory provides the potential to optimize design tradeoffs for detection tasks. For example it may help us understand how to push the limits of specific features, such as spatial resolution, without significantly compromising overall detection performance.

Algorithms↗

Coded pulse excitation for ultrasonic strain imaging.

Decorrelation strain noise can be significantly reduced in low echo-signal-to-noise (eSNR) conditions using coded excitation. Large time-bandwidth-product (>30) pulses are transmitted into tissue mimicking phantoms with 2.5-mm diameter inclusions that mimic the elastic properties of breast lesions. We observed a 5-10 dB improvement in eSNR that led to a doubling of the depth of focus for strain images with no reduction of spatial resolution. In high eSNR conditions, coded excitation permits the use of higher carrier frequencies and shorter correlation windows to improve the attainable spatial resolution for strain relative to that obtained with conventional short pulses. This paper summarizes comparative studies of strain imaging in noise-limited conditions obtained by short pulses and four common aperiodic codes (chirp, Barker, suboptimal, and Golay) as a function of attenuation, eSNR and applied strain. Imaging performance is quantified using SNR for displacement (SNRd), local modulation transfer function (LMTF), and contrast-to-noise ratio for strain (CNRepsilon). We found that chirp and Golay codes are the most robust for imaging soft tissue deformation using matched filter decoding. Their superior performance is obtained by balancing the need for low-range lobes, large eSNR improvement, and short-code duration.

Animals↗

Viscoelastic imaging of breast tumor microenvironment with ultrasound.

Imaging systems are most effective for detection and classification when they exploit contrast mechanisms specific to particular disease processes. A common example is mammography, where the contrast depends on local changes in cell density and the presence of microcalcifications. Unfortunately the specificity for classifying malignant breast disease is relatively low for many current diagnostic techniques. This paper describes a new ultrasonic technique for imaging the viscoelastic properties of breast tissue. The mechanical properties of glandular breast tissue, like most biopolymers, react to mechanical stimuli in a manner specific to the microenvironment of the tissue. Elastic properties allow noninvasive imaging of desmoplasia while viscous properties describe metabolism-dependent features such as pH. These ultrasonic methods are providing new tools for studying disease mechanisms as well as improving diagnosis.

Animals↗

Ultrasound elastography based on multiscale estimations of regularized displacement fields.

Elasticity imaging is based on the measurements of local tissue deformation. The approach to ultrasound elasticity imaging presented in this paper relies on the estimation of dense displacement fields by a coarse-to-fine minimization of an energy function that combines constraints of conservation of echo amplitude and displacement field continuity. The multiscale optimization scheme presents several characteristics aimed at improving and accelerating the convergence of the minimization process. This includes the nonregularized initialization at the coarsest resolution and the use of adaptive configuration spaces. Parameters of the energy model and optimization were adjusted using data obtained from a tissue-like phantom material. Elasticity images from normal in vivo breast tissue were subsequently obtained with these parameters. Introducing a smoothness constraint into motion field estimation helped solve ambiguities due to incoherent motion, leading to elastograms less degraded by decorrelation noise than the ones obtained from correlation-based techniques.

Algorithms↗

Linear approach to axial resolution in elasticity imaging.

Thus far axial resolution in elasticity imaging has been addressed only empirically. No clear analytical approaches have emerged because the estimator is non-linear in the data, correlation functions are nonstationary, and system responses vary spatially. This paper describes a linear systems approach based on a small-strain impulse approximation that results in the derivation of a local impulse response (LIR) and local modulation transfer function (LMTF). Closed-form solutions for strain LIR are available to provide new insights on the role of instrumentation and processing on axial strain resolution. Novel phantom measurements are generated to validate results. We found that the correlation window determines axial resolution in most practical situations, but that the the same system properties that determine B-mode resolution ultimately limit elasticity imaging.

Animals↗

Ideal observer model for detection of blood perfusion and flow using ultrasound.

An ideal observer model is developed for the task of detecting blood perfusing or flowing through tissue. The ideal observer theory relies on a linear systems model that describes tissue and blood object functions and electronic noise as random processes. When aliasing is minimal, the system is characterized by a quantity similar to Noise-Equivalent Quanta used in photon imaging modalities. A simple 1-D model is used to illustrate the effect of the system and object parameters on task performance. Velocity and decorrelation are seen to be advantageous for detection. Aliasing can degrade performance. The ideal observer model provides a framework for assessing the performance of Power Doppler ultrasound systems, and may aid in their design.

Algorithms↗

On the ultrasonic properties of tendon.

The strong dependence of tendon echogenicity on insonation angle is explored by analyzing echo spectra. Combining echo spectra with high-resolution images from several modalities reveals that fluid spaces surrounding fascicles and bundles are likely sources of ultrasonic scatter. Mathematical models of tendon structure are proposed to explain how the anisotropic microstructure of tendon gives rise to angle-dependent echogenicity. Echo spectra from spontaneously damaged equine tendon samples were compared with normal equine tendon and found to exhibit a dramatic decrease in anisotropic properties that appears to be related to the spatial organization and type of collagen generated during repair. Variation in echo spectra with insonation angle is a robust indicator of mechanical damage.

Anisotropy↗

Linear system models for ultrasonic imaging: application to signal statistics.

Linear equations for modeling echo signals from shift-variant systems forming ultrasonic B-mode, Doppler, and strain images are analyzed and extended. The approach is based on a solution to the homogeneous wave equation for random inhomogeneous media. When the system is shift-variant, the spatial sensitivity function--defined as a spatial weighting function that determines the scattering volume for a fixed point of time--has advantages over the point-spread function traditionally used to analyze ultrasound systems. Spatial sensitivity functions are necessary for determining statistical moments in the context of rigorous image quality assessment, and they are time-reversed copies of point-spread functions for shift variant systems. A criterion is proposed to assess the validity of a local shift-invariance assumption. The analysis reveals realistic situations in which in-phase signals are correlated to the corresponding quadrature signals, which has strong implications for assessing lesion detectability. Also revealed is an opportunity to enhance near- and far-field spatial resolution by matched filtering unfocused beams. The analysis connects several well-known approaches to modeling ultrasonic echo signals.

Computer Simulation↗

Adaptive clutter rejection filtering in ultrasonic strain-flow imaging.

This paper introduces strain-flow imaging as a potential new technique for investigating vascular dynamics and tumor biology. The deformation of tissues surrounding pulsatile vessels and the velocity of fluid in the vessel are estimated from the same data set. The success of the approach depends on the performance of a digital filter that must separate echo signal components caused by flow from tissue motion components that vary spatially and temporally. Eigenfilters, which are an important tool for naturally separating signal components adaptively throughout the image, perform very well for this task. The method is examined using two tissue-mimicking flow phantoms that provide stationary and moving clutter associated with pulsatile flow.

Algorithms↗

Microparticle column geometry in acoustic stationary fields.

Particles suspended in a fluid will experience forces from stationary acoustic fields. The magnitude of the force depends on the time-averaged energy density of the field and the material properties of the particles and fluid. Forces acting on known particles smaller than 20 microm were studied. Within a 500 kHz acoustic beam generated by a plane-piston circular source, observations were made of the geometry of the particle column that is formed. Varying the acoustic energy altered the column width in a manner predicted by equations for the primary acoustic radiation force from scattering of particles in the long-wavelength limit. The minimum pressures required to trap gas, solid, and liquid particles in a water medium at room temperature were also estimated to within 12%. These results highlight the ability of stationary acoustic fields from a plane-piston radiator to impose nano-Newton-scale forces onto fluid particles with properties similar to biological cells, and suggest that it is possible to accurately quantify these forces.

Acoustics↗

Vascular elasticity from regional displacement estimates.

A recently-developed ultrasonic technique for measuring elastic properties of vascular tissue is evaluated using computer simulations, phantom and in vivo human measurements. A time sequence of displacement images is measured over the cardiac cycle to describe the spatial and temporal patterns of deformation surrounding arteries. This information is combined with a mathematical model to estimate an elastic modulus. Computer simulations of ultrasonic echo data from deformed tissues are analyzed to define a signal processing approach. Measurements in flow phantoms, with and without vessel-simulating channel walls, provide an assessment of the accuracy and precision of this technique for vascular elasticity measurements. Finally, preliminary results for the stiffness index (beta) in a study group of healthy human volunteers are compared with previously reported data. We find that careful measurement technique is required to control measurement variability.