PubMed Health⌕ Search

Biomedical subjects

Michael Gaitan

Publications and source records attributed to Michael Gaitan.

8 recordsLinked to original sources

Cellular immobilization within microfluidic microenvironments: dielectrophoresis with polyelectrolyte multilayers.

The development of biomimetic microenvironments will improve cell culture techniques by enabling in vitro cell cultures that mimic in vivo behavior; however, experimental control over attachment, cellular position, or intercellular distances within such microenvironments remains challenging. We report here the rapid and controllable immobilization of suspended mammalian cells within microfabricated environments using a combination of electronic (dielectrophoresis, DEP) and chemical (polyelectrolyte multilayers, PEMS) forces. While cellular position within the microsystem is rapidly patterned via intermittent DEP trapping, persistent adhesion after removal of electronic forces is enabled by surface treatment with PEMS that are amenable to cellular attachment. In contrast to DEP trapping alone, persistent adhesion enables the soluble microenvironment to be systematically varied, facilitating the use of soluble probes of cell state and enabling cellular characterization in response to various soluble stimuli.

Animals↗

Facilitating the culture of mammalian nerve cells with polyelectrolyte multilayers.

When neuron-like cells (NLCs) derived from pluripotent embryonal carcinoma cells (P19) are cultured on bare tissue culture substrates, they require a monolayer of fibroblast cells to exhibit normal neurite outgrowth, behavior typical of neuronal cultures. However, substrate treatment with polyelectrolyte multilayers (PEMs) composed of poly(allylamine hydrochloride) (PAH) and poly(styrenesulfonic acid) (PSS) significantly improved these cultures. Cell morphology was more spread, indicative of healthy cells, and direct attachment of neuronal cell bodies to the treated surface was observed. Neuronal outgrowth across the surface was not dependent on an underlying fibroblast monolayer with the PEMs surface treatment. Additionally, the PEMs surface treatment can be used to condition various surfaces, facilitating neuronal cultures on surfaces which are natively hydrophilic (tissue culture polystyrene) or hydrophobic (poly(dimethylsiloxane), PDMS). Microfluidic networks were used to micropattern the PEMs onto PDMS, resulting in confined regions of cellular attachment and directed neuronal outgrowth. The ability of PEMs to encourage NLC attachment without supporting cells to a variety of surfaces and surface geometries greatly simplifies neuronal culture methodology and enables neuronal investigations in new environments.

Animals↗

Capillarity induced solvent-actuated bonding of polymeric microfluidic devices.

Rapid, robust, and economical fabrication of fluidic microchannels is of fundamental importance for the successful development of disposable lab-on-a-chip devices. In this work, we present a solvent-actuated bonding method for fabricating polymeric microfluidic devices at room temperature. A PMMA sheet with an imprinted microchannel was clamped to a blank PMMA sheet, and then 80 +/- 5 muL of acetone (bonding solvent) was introduced at one end of the fluidic channel and aspirated out at the other end. As the solvent moved down the channel, capillary forces drew a fraction of the solvent into the interstitial space between the two polymeric substrates. After aspiration, the assembly was incubated in the clamp for 5 min for effective bond formation. The quantity of the bonding solvent, its water content and flow rate, along with residence time in the channel were found to have significant impact on the bond quality and the channel integrity. Microfluidic electrophoretic separations of a 400-base DNA ladder were performed in devices fabricated using this method in less than 8 min with efficiencies routinely between 2 x 10(6) and 3 x 10(6) plates/m. The simplicity and economy of this technique make it amenable for automation and mass production, which could make polymeric substrates more attractive for single-use chemical analysis devices.

Journal Article↗

Surface modification of poly(methyl methacrylate) for improved adsorption of wall coating polymers for microchip electrophoresis.

The development of rapid and simple wall coating strategies for high-efficiency electrophoretic separation of DNA is of crucial importance for the successful implementation of miniaturized polymeric DNA analysis systems. In this report, we characterize and compare different methods for the chemical modification of poly(methyl methacrylate) (PMMA) surfaces for the application of wall coating polymers. PMMA surfaces coated with 40 mol% diethylacrylamide and 60 mol% dimethylacrylamide are compared to the PMMA surfaces first oxidized and then coated with hydroxypropylmethyl-cellulose or poly(vinyl alcohol) (PVA). PMMA oxidation was accomplished with UV/ozone or an aqueous solution of HNO(3) to yield hydrogen-bond donors for the spontaneous adsorption of the coating polymers. Contact angle measurements of UV/ozone exposed PMMA surfaces indicate increase in hydrophilicity, and polymer coated surfaces show a strong dependence on the coating polymer and the oxidation method. Fast and repeatable electrophoretic separations of a 10-base and 20-base DNA ladder were performed in PMMA micro CE devices. All analyses were completed in less than 10 min, resulting in the number of theoretical plates as high as 583 000 in a 7.7 cm long separation channel. The duration of UV/ozone treatment was found to have a considerable impact on separation performance. The microchips irradiated with UV for 10 min and coated with PVA as well as the microchips treated with HNO(3) and coated with HPMC were found to have the best separation performance. These results demonstrate facile and robust methods for the surface modification of PMMA enabling low-cost single use devices for electrophoretic DNA separations.

Acrylamides↗

Fabrication of polymer microfluidic systems by hot embossing and laser ablation.

Fabrication of microfluidic channels in common commercially available thermoplastic materials can be easily accomplished using hot embossing or ultraviolet (UV) laser ablation. Hot embossing involves replication of a microfluidic network in a polymer substrate from a stamp (or template) fabricated in silicon or metal. UV laser ablation is performed by either exposing the polymer substrate through a mask or by using a laser direct-write process. The resulting polymer microfluidic channels are most often sealed with another polymer piece using thermal bonding or solvent bonding to complete the fabrication procedure. Unlike their silicon and glass counterparts, polymer microfluidic systems can be fabricated by these methods in less than 1 h, making the materials attractive for both research prototyping and commercialization.

Equipment Design↗

Micropatterning neuronal cells on polyelectrolyte multilayers.

This paper describes an approach to adhere retinal cells on micropatterned polyelectrolyte multilayer (PEM) lines adsorbed on poly(dimethylsiloxane) (PDMS) surfaces using microfluidic networks. PEMs were patterned on flat, oxidized PDMS surfaces by sequentially flowing polyions through a microchannel network that was placed in contact with the PDMS surface. Polyethyleneimine (PEI) and poly(allylamine hydrochloride) (PAH) were the polyions used as the top layer cellular adhesion material. The microfluidic network was lifted off after the patterning was completed and retinal cells were seeded on the PEM/PDMS surfaces. The traditional practice of using blocking agents to prevent the adhesion of cells on unpatterned areas was avoided by allowing the PDMS surface to return to its uncharged state after the patterning was completed. The adhesion of rat retinal cells on the patterned PEMs was observed 5 h after seeding. Cell viability and morphology on the patterned PEMs were assayed. These materials proved to be nontoxic to the cells used in this study regardless of the number of stacked PEM layers. Phalloidin staining of the cytoskeleton revealed no apparent morphological differences in retinal cells compared with those plated on polystyrene or the larger regions of PEI and PAH; however, cells were relatively more elongated when cultured on the PEM lines. Cell-to-cell communication between cells on adjacent PEM lines was observed as interconnecting tubes containing actin that were a few hundred nanometers in diameter and up to 55 microm in length. This approach provides a simple, fast, and inexpensive method of patterning cells onto micrometer-scale features.

Animals↗

Controlled vesicle self-assembly in microfluidic channels with hydrodynamic focusing.

Traditional liposome preparation methods are based on mixing of bulk phases, leading to inhomogeneous chemical and/or mechanical conditions during formation; hence liposomes are often polydisperse in size and lamellarity. Here we show the formation of liposomes that encapsulate reagents in a continuous two-phase flow microfluidic network with precision control of size from 100 to 300 nm by manipulation of liquid flow rates. We demonstrate that by creating a solvent-aqueous interfacial region in a microfluidic format that is homogeneous and controllable on the length scale of a liposome, we can facilitate the fine control of liposome size and polydispersity.

Fluoresceins↗

Liposomes as signal amplification reagents for bioassays in microfluidic channels.

Liposomes with encapsulated carboxyfluorescein were used in an affinity-based assay to provide signal amplification for small-volume fluorescence measurements. Microfluidic channels were fabricated by imprinting in a plastic substrate material, poly(ethylene terephthalate glycol) (PETG), using a silicon template imprinting tool. Streptavidin was linked to the surface through biotinylated-protein for effective immobilization with minimal nonspecific adsorption of the liposome reagent. Lipids derivatized with biotin were incorporated into the liposome membrane to make the liposomes reactive for affinity assays. Specific binding of the liposomes to microchannel walls, dependence of binding on incubation time, and nonspecific adsorption of the liposome reagent were evaluated. The results of a competitive assay employing liposomes in the microchannels are presented.

Electrophoresis, Capillary↗