Hydrothermal growth of mesoporous SBA-15 silica in the presence of PVP-stabilized Pt nanoparticles: synthesis, characterization, and catalytic properties.

A novel high surface area heterogeneous catalyst based on solution phase colloidal nanoparticle chemistry has been developed. Monodisperse platinum nanoparticles of 1.7-7.1 nm have been synthesized by alcohol reduction methods and incorporated into mesoporous SBA-15 silica during hydrothermal synthesis. Characterization of the Pt/SBA-15 catalysts suggests that Pt particles are located within the surfactant micelles during silica formation leading to their dispersion throughout the silica structure. After removal of the templating polymer from the nanoparticle surface, Pt particle sizes were determined from monolayer gas adsorption measurements. Infrared studies of CO adsorption revealed that CO exclusively adsorbs to atop sites and red-shifts as the particle size decreases suggesting surface roughness increases with decreasing particle size. Ethylene hydrogenation rates were invariant with particle size and consistent with a clean Pt surface. Ethane hydrogenolysis displayed significant structure sensitivity over the size range of 1-7 nm, while the apparent activation energy increased linearly up to a Pt particle size of approximately 4 nm and then remained constant. The observed rate dependence with particle size is attributed to a higher reactivity of coordinatively unsaturated surface atoms in small particles compared to low-index surface atoms prevalent in large particles. The most reactive of these unsaturated surface atoms are responsible for ethane decomposition to surface carbon. The ability to design catalytic structures with tunable properties by rational synthetic methods is a major advance in the field of catalyst synthesis and for the development of accurate structure-function relationships in heterogeneous reaction kinetics.

Journal Article↗

Automatic selection of the optimal cardiac phase for gated three-dimensional coronary x-ray angiography.

RATIONALE AND OBJECTIVES: For the reconstruction of the coronary arteries from rotational angiography data, a crucial point is the selection of the optimal cardiac phase for data reconstruction. To avoid time-consuming interactive selection of the optimal cardiac phase by visual inspection of multiple high-resolution data sets reconstructed at different cardiac phases, an automatic approach for deriving optimal reconstruction windows is attractive. MATERIALS AND METHODS: This paper presents a new approach to fully automatic selection of the optimal cardiac phase for image reconstruction. It is based on the analysis of a four-dimensional data set of the region of interest reconstructed at low-spatial resolution utilizing an image quality index, which quantifies the image quality of a single three-dimensional reconstructed volume. The derived image quality index utilizes the histogram information of a single temporal snapshot as a quality measure for the vessel reconstruction. The proposed technique was applied to 16 projection data sets obtained in eight pigs. RESULTS: Experiments to evaluate the proposed method based on user-defined image quality parameters serving as ground truth, showed a relatively high correlation (>84%) for high-quality (c(phi) > 0.95) images. CONCLUSION: An image-based technique is introduced, which is able to determine the optimal cardiac phase for 3D-RCA fully automatically. The proposed method was successfully applied to 16 data sets obtained in a total of 8 porcine models.

Algorithms↗

Three-dimensional X-ray coronary angiography in the porcine model: A feasibility study.

RATIONALE AND OBJECTIVES: Three-dimensional high-spatial-resolution angiograms of the coronary arteries were acquired with an electrocardiogram-gated three-dimensional rotational angiography technique on an interventional X-ray system. MATERIALS AND METHODS: During selective injection of contrast material in the left and right coronary artery, projection images were obtained in eight pigs during a continuous rotation of the X-ray gantry over an angular range of 180 degrees within 8 seconds. RESULTS: Three-dimensional tomographic reconstruction depicted the proximal, medial, and distal sections of the main arteries as well as the main bifurcations in multiple cardiac phases in all animals. CONCLUSIONS: For the first time, this feasibility study shows that a three-dimensional angiogram of the coronary arteries can be obtained intraprocedurally in a conventional interventional suite by means of tomographic reconstruction from projection images.

Algorithms↗

Motion-compensated and gated cone beam filtered back-projection for 3-D rotational X-ray angiography.

This paper presents a method to reconstruct moving objects from cone beam X-ray projections acquired during a single rotational run using a given motion vector field. The method is applicable to voxel driven cone-beam filtered back-projection reconstruction approaches. Here, a formulation based on the algorithm of Feldkamp, Davis, and Kress (FDK) is presented. The motion correction is applied during the back-projection step by shifting the voxel to be reconstructed according to the motion vector field. The method is applied to three-dimensional (3-D) rotational X-ray angiography. Projections from a beating coronary heart phantom are simulated. Motion-compensated reconstructions with varying accuracy of the applied motion field are carried out for a late diastolic heart phase and compared to the reconstruction obtained with the standard FDK-method from projections of the corresponding motion-free model in the same heart phase. Furthermore, gated reconstructions are calculated by weighting the projections according to their cardiac phase without using a motion vector field. Different gating window widths are applied, and the reconstructions are compared. Using the correct motion field with the motion-compensated reconstruction, the image quality of the standard reconstruction from the corresponding motion-free coronary model can almost be recovered. The reconstructed image quality stays acceptable if the accuracy of the motion field sampling points is better than 1 mm. The gated reconstructions with a window width of 15%-20% of the cardiac cycle lead to superior results compared to nearest neighbor gating, especially for histogram based visualization and analysis. The motion-compensated reconstructions provide sharp images of the coronaries far surpassing the image quality of gated reconstructions.

Algorithms↗

CEnPiT: helical cardiac CT reconstruction.

Computer tomography (CT) scanners with an increasing number of detector rows offer the potential of shorter scanning times. Nevertheless, the reconstruction problem becomes more challenging, since cone beam artifacts are likely to enter. Here, we consider helical cardiac CT. We analyze how a relationship can be established between exact reconstruction algorithms and the demand to perform a cardiac gating. Utilizing the redundancies requires the consideration of all kinds of Radon planes. For the reconstruction algorithm proposed here, we separate the data into two parts. The first part contains contributions of Radon planes, which are measured with a large number of redundancies. The second part contains the remaining contributions. As it turns out, the second part contributes rather to the low-frequency contents of trans-axial slices. Therefore, we propose to perform a gated back-projection only for the first part, while the second part is back-projected in an ungated way. Data from the complete source trajectory are employed in the reconstruction process in contrary to conventional helical cardiac reconstruction methods. Moreover, all different types of Radon planes are taken into account in the reconstruction, though an ECG-dependent cardiac gating is applied. The reconstruction results, which we present for clinical and simulated data, demonstrate the high potential of CEnPiT for helical cardiac CT with large cone angle systems.

Algorithms↗

Reconstruction of blood propagation in three-dimensional rotational X-ray angiography (3D-RA).

This paper presents a framework of non-interactive algorithms for the mapping of blood flow information to vessels in 3D-RA images. With the presented method, mapping of flow information to 3D-RA images is done automatically without user interaction. So far, radiologists had to perform this task by extensive image comparisons and did not obtain visualizations of the results. In our approach, flow information is reconstructed by forward projection of vessel pieces in a 3D-RA image to a two-dimensional projection series capturing the propagation of a short additional contrast agent bolus. For accurate 2D-3D image registration, an efficient patient motion compensation technique is introduced. As an exemplary flow-related quantity, bolus arrival times are reconstructed for the vessel pieces by matching of intensity-time curves. A plausibility check framework was developed which handles projection ambiguities and corrects for noisy flow reconstruction results. It is based on a linear programming approach to model the feeding structure of the vessel. The flow reconstruction method was applied to 12 cases of cerebral stenoses, AVMs and aneurysms, and it proved to be feasible in the clinical environment. The propagation of the injected contrast agent was reconstructed and visualized in three-dimensional images. The flow reconstruction method was able to visualize different types of useful information. In cases of stenosis of the middle cerebral artery (MCA), flow reconstruction can reveal impeded blood flow depending on the severeness of the stenosis. With cases of AVMs, flow reconstruction can clarify the feeding structure. The presented methods handle the problems imposed by clinical demands such as non-interactive algorithms, patient motion compensation, short reconstruction times, and technical requirements such as correction of noisy bolus arrival times and handling of overlapping vessel pieces. Problems occurred mainly in the reconstruction and segmentation of 3D-RA images in cases of complex AVMs. The concentration of injected contrast agent was often not sufficient to provide highly contrasted vessels in 3D-RA images. Another segmentation-related problem is known as 'kissing vessels' [19]. Kissing vessel artifacts introduce artificial vessel junctions and thereby distort the feeding structure of the vessel. This may finally cause implausible flow reconstruction results and inverse flow directions in vessel segments. We are currently planning to validate our reconstruction results using particle imaging velocimetry (PIV). PIV experiments with phantoms, for which the true flow parameters are known, will allow for the assessment of the accuracy of our contrast agent based method. In the context of computational fluid dynamics techniques, the potential of the presented flow reconstruction method is high. Flow reconstruction results based on the presented method could be used both as boundary conditions for simulations and as a reference for the validation of simulation results. Computational fluid dynamics provide useful information such as arterial wall shear stress and complex flow patterns in aneurysms.

Algorithms↗

Automatic determination of minimal cardiac motion phases for computed tomography imaging: initial experience.

Low motion phases for cardiac computed tomography reconstructions are currently detected manually in a user-dependent selection process which is often time consuming and suboptimal. The concept of motion maps was recently introduced to achieve automatic phase selection. This pilot study compared the accuracy of motion-map phase selection to that with manual iterative selection. The study included 20 patients, consisting of one group with low and one with high heart rate. The technique automatically derives a motion strength function between multiple low-resolution reconstructions through the cardiac cycle, with periods of lowest difference between neighboring phases indicating minimal cardiac motion. A high level of agreement was found for phase selection achieved with the motion map approach compared with the manual iterative selection process. The motion maps allowed automated quiescent phase detection of the cardiac cycle in 85% of cases, with best results at low heart rates and for the left coronary artery. They can also provide additional information such as the presence of breathing artifacts. Motion maps show promise as a rapid off-line tool to automatically detect quiescent cardiac phases in a variety of patients.

Adult↗

Precise control of the Pt nanoparticle size by seeded growth using EO13PO30EO13 triblock copolymers as protective agents.

Here, we report an efficient way to produce homogeneous Pt nanoparticles within a well-defined size range (3.5-6.6 nm) as a result of the seeded growth procedure using Pluronic L64 polymer capping agent. First, small seeds (3.5 nm) were prepared by the reduction of H2PtCl6.6H2O in water with NaBH4 in the presence of the capping poly(ethylene oxide)13-poly(propylene oxide)30-poly(ethylene oxide)13 triblock copolymer at room temperature. Additional anionic Pt salt was then introduced under flowing H2 to obtain larger nanoparticles.

Journal Article↗

Noninvasive coronary angiography with 16-detector row CT: effect of heart rate.

PURPOSE: To evaluate the effect of heart rate on the quality of coronary angiograms obtained with 16-detector row computed tomography (CT) by using temporally enhanced three-dimensional (3D) approaches. MATERIALS AND METHODS: The local ethics committee approved the study, and informed consent was obtained from all patients. Fifty patients underwent coronary CT angiography (heart rate range, 45-103 beats per minute). Raw data from helical CT and electrocardiography (ECG) were saved in a combined data set. Retrospectively ECG-gated images were reconstructed at preselected phases (50% and 80%) of the cardiac cycle. A 3D voxel-based approach with cardiac phase weighting was used for reconstruction. Testing for correlation between heart rate, cardiac phase reconstruction window, and image quality was performed with Kruskal-Wallis analysis. Image quality (freedom from cardiac motion-related artifacts) was referenced against findings at conventional angiography in a secondary evaluation step. Regression analysis was performed to calculate heart rate thresholds for future beta-blocker application. RESULTS: A significant negative correlation was observed between heart rate and image quality (r = 0.80, P < .001). Motion artifact-free images were available for 44 (88%) patients and were achieved consistently at a heart rate of 80 or fewer beats per minute (n = 39). Best image quality was achieved at 75 or fewer beats per minute. Segmental analysis revealed that 97% of arterial segments (diameter > or = 1.5 mm according to conventional angiography) were assessable at 80 or fewer beats per minute. Premature ventricular contractions and rate-contained arrhythmia did not impede diagnostic assessment of the coronary arteries in 10 (83%) of the 12 patients affected. CONCLUSION: Motion-free coronary angiograms can be obtained consistently with 16-detector row CT scanners and adaptive multicyclic reconstruction algorithms in patients with heart rates of less than 80 beats per minute.

Adult↗

Artifact analysis and reconstruction improvement in helical cardiac cone beam CT.

With the introduction of cone beam (CB) scanners, cardiac volumetric computed tomography (CT) imaging has the potential to become a noninvasive imaging tool in clinical routine for the diagnosis of various heart diseases. Heart rate adaptive reconstruction schemes enable the reconstruction of high-resolution volumetric data sets of the heart. Artifacts, caused by strong heart rate variations, high heart rates and obesity, decrease the image quality and the diagnostic value of the images. The image quality suffers from streak artifacts if suboptimal scan and reconstruction parameters are chosen, demanding improved gating techniques. In this paper, an artifact analysis is carried out which addresses the artifacts due to the gating when using a three-dimensional CB cardiac reconstruction technique. An automatic and patient specific cardiac weighting technique is presented in order to improve the image quality. Based on the properties of the reconstruction algorithm, several assessment techniques are introduced which enable the quantitative determination of the cycle-to-cycle transition smoothness and phase homogeneity of the image reconstruction. Projection data of four patients were acquired using a 16-slice CBCT system in low pitch helical mode with parallel electrocardiogram recording. For each patient, image results are presented and discussed in combination with the assessment criteria.

Algorithms↗

Image stacking with entropy values in conventional angiography: initial experience.

The entropy method for stacking a series of angiographic images is presented and compared with the maximum opacity method, which is already established. The entropy method comprises calculation of the entropy of the time course for each image pixel. This accentuates image areas where a contrast agent bolus is passing. Quantitative analysis of the contrast-to-noise ratio and qualitative analysis of 11 cases were performed, the latter by eight independent viewers. Results indicate that the entropy images show more vascular detail in small peripheral vessels and increased contrast-to-noise ratio by up to a factor of 1.97 compared with maximum opacity images.

Adult↗

Real-time adaptive filtering for projection reconstruction MR fluoroscopy.

Magnetic resonance (MR) imaging has faced a dramatic increase in real-time capabilities over the last years. However, the application of fast pulse sequences still suffers from low signal-to-noise ratios (SNRs), which can be the limiting factor for the actual acquisition speed. In MR fluoroscopy, filtering along the time and/or spatial domain can be applied to increase the image quality. In this paper, a projection-based noise filter is presented that significantly enhances the SNR in projection reconstruction (PR) fluoroscopy without apparent loss of resolution in the reconstructed images. In contrast to an imaged-based approach, this method allows a very efficient computational implementation. The filter algorithm was implemented on a digital signal processor and was applied to real-time processing during PR fluoroscopy. A quantitative analysis of the improvement in SNR and results for different fluoroscopic MR applications are given. Apart from MR fluoroscopy, the proposed technique has the potential to be applied to low dose computed tomography fluoroscopy.

Algorithms↗