Intraoperative cortical surface characterization using laser range scanning: preliminary results.

OBJECTIVE: To present a novel methodology that uses a laser range scanner (LRS) capable of generating textured (intensity-encoded) surface descriptions of the brain surface for use with image-to-patient registration and improved cortical feature recognition during intraoperative neurosurgical navigation. METHODS: An LRS device was used to acquire cortical surface descriptions of eight patients undergoing neurosurgery for a variety of clinical presentations. Textured surface descriptions were generated from these intraoperative acquisitions for each patient. Corresponding textured surfaces were also generated from each patient's preoperative magnetic resonance tomograms. Each textured surface pair (LRS and magnetic resonance tomogram) was registered using only cortical surface information. Novel visualization of the combined surfaces allowed for registration assessment based on quantitative cortical feature alignment. RESULTS: Successful textured LRS surface acquisition and generation was performed on all eight patients. The data acquired by the LRS accurately presented the intraoperative surface of the cortex and the associated features within the surgical field-of-view. Registration results are presented as overlays of the intraoperative data with respect to the preoperative data and quantified by comparing mean distances between cortical features on the magnetic resonance tomogram and LRS surfaces after registration. The overlays demonstrated that accurate registration can be provided between the preoperative and intraoperative data and emphasized a potential enhancement to cortical feature recognition within the operating room environment. Using the best registration result from each clinical case, the mean feature alignment error is 1.7 +/- 0.8 mm over all cases. CONCLUSION: This study demonstrates clinical deployment of an LRS capable of generating textured surfaces of the surgical field of view. Data from the LRS was registered accurately to the corresponding preoperative data. Visual inspection of the registration results was provided by overlays that put the intraoperative data within the perspective of the whole brain's surface. These visuals can be used to more readily assess the fidelity of image-to-patient registration, as well as to enhance recognition of cortical features for assistance in comparing the neurotopography between magnetic resonance image volume and physical patient. In addition, the feature-rich data presented here provides considerable motivation for using LRS scanning to measure deformation during surgery.

Adult↗

A method to track cortical surface deformations using a laser range scanner.

This paper reports a novel method to track brain shift using a laser-range scanner (LRS) and nonrigid registration techniques. The LRS used in this paper is capable of generating textured point-clouds describing the surface geometry/intensity pattern of the brain as presented during cranial surgery. Using serial LRS acquisitions of the brain's surface and two-dimensional (2-D) nonrigid image registration, we developed a method to track surface motion during neurosurgical procedures. A series of experiments devised to evaluate the performance of the developed shift-tracking protocol are reported. In a controlled, quantitative phantom experiment, the results demonstrate that the surface shift-tracking protocol is capable of resolving shift to an accuracy of approximately 1.6 mm given initial shifts on the order of 15 mm. Furthermore, in a preliminary in vivo case using the tracked LRS and an independent optical measurement system, the automatic protocol was able to reconstruct 50% of the brain shift with an accuracy of 3.7 mm while the manual measurement was able to reconstruct 77% with an accuracy of 2.1 mm. The results suggest that a LRS is an effective tool for tracking brain surface shift during neurosurgery.

Algorithms↗

Compensating for intraoperative soft-tissue deformations using incomplete surface data and finite elements.

Image-guided liver surgery requires the ability to identify and compensate for soft tissue deformation in the organ. The predeformed state is represented as a complete three-dimensional surface of the organ, while the intraoperative data is a range scan point cloud acquired from the exposed liver surface. The first step is to rigidly align the coordinate systems of the intraoperative and preoperative data. Most traditional rigid registration methods minimize an error metric over the entire data set. In this paper, a new deformation-identifying rigid registration (DIRR) is reported that identifies and aligns minimally deformed regions of the data using a modified closest point distance cost function. Once a rigid alignment has been established, deformation is accounted for using a linearly elastic finite element model (FEM) and implemented using an incremental framework to resolve geometric nonlinearities. Boundary conditions for the incremental formulation are generated from intraoperatively acquired range scan surfaces of the exposed liver surface. A series of phantom experiments is presented to assess the fidelity of the DIRR and the combined DIRR/FEM approaches separately. The DIRR approach identified deforming regions in 90% of cases under conditions of realistic surgical exposure. With respect to the DIRR/FEM algorithm, subsurface target errors were correctly located to within 4 mm in phantom experiments.

Algorithms↗

Modality independent elastography (MIE): potential applications in dermoscopy.

The use of palpation information for skin disease characterization is not as commonly used as in other soft tissues, although mechanical differences within lesions have been noted. For example, regions of hyperkeratosis have the potential to transform into cancerous lesions and likely feature different material properties from those of surrounding normal tissue due to varying cytoarchitecture. As a result, the spatial distribution of lesion mechanical properties may serve to assist a diagnosis or enhance visualization of the complete extent of a cancerous region, i.e., accurate information regarding the margins of disease for surgical therapy. In this work, a multiresolution extension to a novel elastographic imaging method called Modality Independent Elastography (MIE) is used to characterize the mechanical properties of a skin-like phantom embedded with a mock stiff lesion. Simulation studies were also performed to investigate the potential for characterizing realistic melanoma lesions. Elasticity image reconstructions from the phantom experiments localized the stiff inclusion and had good correlation between the Young's modulus contrast ratio and experimental measurements from material testing. In addition, multiresolution MIE was shown to be a more robust framework than its single-resolution version. Results from the melanoma simulation demonstrate the potential for using multiresolution MIE with dermoscopic images.

Algorithms↗

Modality independent elastography (MIE): a new approach to elasticity imaging.

The correlation between tissue stiffness and health is an accepted form of organ disease assessment. As a result, there has been a significant amount of interest in developing methods to image elasticity parameters (i.e., elastography). The modality independent elastography (MIE) method combines a nonlinear optimization framework, computer models of soft-tissue deformation, and standard measures of image similarity to reconstruct elastic property distributions within soft tissue. In this paper, simulation results demonstrate successful elasticity image reconstructions in breast cross-sectional images acquired from magnetic resonance (MR) imaging. Results from phantom experiments illustrate its modality independence by reconstructing elasticity images of the same phantom in both MR and computed tomographic imaging units. Additional results regarding the performance of a new multigrid strategy to MIE and the implementation of a parallel architecture are also presented.

Algorithms↗

A new approach to elastography using mutual information and finite elements.

Historically, increased mechanical stiffness during tissue palpation exams has been associated with assessing organ health as well as with detecting the growth of a potentially life-threatening cell mass. As such, techniques to image elasticity parameters (i.e., elastography) have recently become of great interest to scientists. In this work, a new method of elastography will be introduced within the context of mammographic imaging. The elastography method proposed represents a non-rigid iterative image registration algorithm that varies material properties within a finite element model to improve registration. More specifically, regional measures of image similarity are used within an objective function minimization framework to reconstruct elasticity images of tissue stiffness. Numerical simulations illustrate: (1) the encoding of stiffness information within the context of a regional image similarity criterion, (2) the methodology for an iterative elastographic imaging framework and (3) elasticity reconstruction simulations. The real strength in this approach is that images from any modality (e.g., magnetic resonance, computed tomography, ultrasound. etc) that have sufficient anatomically-based intensity heterogeneity and remain consistent from a pre- to a post-deformed state could be used in this paradigm.

Adipose Tissue↗

Cortical surface registration for image-guided neurosurgery using laser-range scanning.

In this paper, a method of acquiring intraoperative data using a laser range scanner (LRS) is presented within the context of model-updated image-guided surgery. Registering textured point clouds generated by the LRS to tomographic data is explored using established point-based and surface techniques as well as a novel method that incorporates geometry and intensity information via mutual information (SurfaceMI). Phantom registration studies were performed to examine accuracy and robustness for each framework. In addition, an in vivo registration is performed to demonstrate feasibility of the data acquisition system in the operating room. Results indicate that SurfaceMI performed better in many cases than point-based (PBR) and iterative closest point (ICP) methods for registration of textured point clouds. Mean target registration error (TRE) for simulated deep tissue targets in a phantom were 1.0 +/- 0.2, 2.0 +/- 0.3, and 1.2 +/- 0.3 mm for PBR, ICP, and SurfaceMI, respectively. With regard to in vivo registration, the mean TRE of vessel contour points for each framework was 1.9 +/- 1.0, 0.9 +/- 0.6, and 1.3 +/- 0.5 for PBR, ICP, and SurfaceMI, respectively. The methods discussed in this paper in conjunction with the quantitative data provide impetus for using LRS technology within the model-updated image-guided surgery framework.

Adult↗

Incorporation of a laser range scanner into image-guided liver surgery: surface acquisition, registration, and tracking.

As image guided surgical procedures become increasingly diverse, there will be more scenarios where point-based fiducials cannot be accurately localized for registration and rigid body assumptions no longer hold. As a result, procedures will rely more frequently on anatomical surfaces for the basis of image alignment and will require intraoperative geometric data to measure and compensate for tissue deformation in the organ. In this paper we outline methods for which a laser range scanner may be used to accomplish these tasks intraoperatively. A laser range scanner based on the optical principle of triangulation acquires a dense set of three-dimensional point data in a very rapid, noncontact fashion. Phantom studies were performed to test the ability to link range scan data with traditional modes of image-guided surgery data through localization, registration, and tracking in physical space. The experiments demonstrate that the scanner is capable of localizing point-based fiducials to within 0.2 mm and capable of achieving point and surface based registrations with target registration error of less than 2.0 mm. Tracking points in physical space with the range scanning system yields an error of 1.4 +/- 0.8 mm. Surface deformation studies were performed with the range scanner in order to determine if this device was capable of acquiring enough information for compensation algorithms. In the surface deformation studies, the range scanner was able to detect changes in surface shape due to deformation comparable to those detected by tomographic image studies. Use of the range scanner has been approved for clinical trials, and an initial intraoperative range scan experiment is presented. In all of these studies, the primary source of error in range scan data is deterministically related to the position and orientation of the surface within the scanner's field of view. However, this systematic error can be corrected, allowing the range scanner to provide a rapid, robust method of acquiring anatomical surfaces intraoperatively.

Aged↗

Source localization using a current-density minimization approach.

Determining the location of cortical activity from electroencephalographic (EEG) data is important clinically. In this paper, a method is presented which uses the powerful optimization method of simulated annealing in conjunction with a finite-element-based model of the search domain for single-time slice solution of the EEG-inverse problem. The algorithm highlights a new objective function based on the current-density boundary integral associated with the finite-element formulation as the basis for parameter optimization. In two-dimensional experiments in a shallow tank containing saline, single dipoles are located within 2 mm. Simulations studying the algorithms response to structured noise are also presented. The new objective function is shown to take advantage of the natural framework associated with finite-elements and the results suggest that the approach is capable of resolving dipole locations in simulations and experiments.

Brain Mapping↗

In vivo quantification of retraction deformation modeling for updated image-guidance during neurosurgery.

The use of coregistered preoperative anatomical scans to provide navigational information in the operating room has greatly benefited the field of neurosurgery. Nonetheless, it has been widely acknowledged that significant errors between the operating field and the preoperative images are generated as surgery progresses. Quantification of tissue shift can be accomplished with volumetric intraoperative imaging; however, more functional, lower cost alternative solutions to this challenge are desirable. We are developing the strategy of exploiting a computational model driven by sparse data obtained from intraoperative ultrasound and cortical surface tracking to warp preoperative images to reflect the current state of the operating field. This paper presents an initial quantification of the predictive capability of the current model to computationally capture tissue deformation during retraction in the porcine brain. Performance validation is achieved through comparisons of displacement and pressure predictions to experimental measurements obtained from computed tomographic images and pressure sensor recordings. Group results are based upon a generalized set of boundary conditions for four subjects that, on average, account for at least 75% of tissue motion generated during interhemispheric retraction. Individualized boundary conditions can improve the degree of data-model match by 10% or more but warrant further study. Overall, the level of quantitative agreement achieved in these experiments is encouraging for updating preoperative images to reflect tissue deformation resulting from retraction, especially since model improvements are likely as a result of the intraoperative constraints that can be applied through sparse data collection.

Animals↗