PubMed Health⌕ Search

Biomedical subjects

Michael Isaacson

Publications and source records attributed to Michael Isaacson.

2 recordsLinked to original sources

On-chip micro-biosensor for the detection of human CD4(+) cells based on AC impedance and optical analysis.

The current study was undertaken to fabricate a small micro-electrode on-chip to rapidly detect and quantify human CD4(+) cells in a minimal volume of blood through impedance measurements made with simple electronics that could be battery operated implemented in a hand held device. The micro-electrode surface was non-covalently modified sequentially by incubation with solutions of protein G', human albumin, monoclonal mouse anti-human CD4, and mouse IgG. The anti-human CD4 antibody served as the recognition and capture molecule for CD4(+) cells present in human blood. The binding of these biomolecules to the micro-electrodes was verified by impedance and cyclic voltammetry measurements. An increase in impedance was detected for each layer of protein adsorbed onto the micro-electrode surface. This process was shown to be highly repeatable. Increased impedance was measured when CD4(+) cells were captured on the micro-electrode, and the impedance also increased as the number of captured cells increased. Fluorescence microscopy of captured cells immunolabeled with anti-human CD4, CD8, and CD19 antibodies, and the nuclear label DAPI, confirmed that only CD4(+) cells were captured. The results were highly dependent on the specimen preparation method used. We conclude that the on-chip capture system can efficiently quantify the number of CD4(+) cells.

Biosensing Techniques↗

Controlling cellular reactive responses around neural prosthetic devices using peripheral and local intervention strategies.

While chronic use of indwelling micromachined neural prosthetic devices has great potential, the development of reactive responses around them results in a decrease in electrode function over time. Since the cellular events responsible for these responses may be anti-inflammatory in nature, we have tested the effectiveness of dexamethasone and cyclosporin A as potential drugs for developing intervention strategies following insertion of single-shank micromachined silicon devices. Peripheral injection of dexamethasone was effective in attenuating increased expression of glial fibrillary acidic protein and astrocyte hyperplasia observed during both initial- and sustained-reactive responses observed at one and six weeks post insertion, respectively. Peripheral injection of cyclosporin A had no positive effect. If anything, application of this drug increased the early reactive response. Effectiveness of local release of dexamethasone in rat neocortex was tested by inserting ribbons of poly (ethyl-vinyl) acetate containing 35% (w/w) dexamethasone. Initial concentrations of dexamethasone were similar to those obtained by peripheral injection. Local drug release provided continued control of cellular reactive responses during the six-week study period. These results demonstrate that peripheral delivery of dexamethasone can be used to control reactive responses and that local drug delivery by slow-release from biocompatible polymers may be a more effective method of drug intervention. Incorporating these strategies on micromachined devices may provide an intervention strategy that will insure the chronic functioning of electrodes on intracortical neuroprosthetic devices.

Animals↗