Quality of life after vagus nerve stimulation for intractable epilepsy: is seizure control the only contributing factor?

We assessed the impact of vagus nerve stimulation on a cohort of patients with intractable epilepsy. A 1-year prospective trial of vagus nerve stimulation for intractable epilepsy was done in 26 patients. Seizure frequency, anti-epileptic drugs, and quality of life were assessed using QOLIE-89, ELDQOL, and a Likert scale of impact of treatment. Seizures were reduced by more than 50% in 19% of the patients, by less than 50% in 46%, and were unchanged in 35% of them. Antiepileptic drugs were reduced in 43% of the patients. There was a significant improvement in the mean overall QOLIE-89 score and other measures of quality of life, but these did not correlate with changes in seizure frequency. Subjective improvement occurred in 84% of the patients. The quality of life improves in some patients following vagus nerve stimulation for intractable epilepsy. The favorable effects of this treatment may be attributable to additional factors besides seizure control which in this study was modest.

Adaptation, Psychological↗

Left ventricular outflow tract mean systolic acceleration as a surrogate for the slope of the left ventricular end-systolic pressure-volume relationship.

OBJECTIVE: The goal of this study was to analyze left ventricular outflow tract systolic acceleration (LVOT(Acc)) during alterations in left ventricular (LV) contractility and LV filling. BACKGROUND: Most indexes described to quantify LV systolic function, such as LV ejection fraction and cardiac output, are dependent on loading conditions. METHODS: In 18 sheep (4 normal, 6 with aortic regurgitation, and 8 with old myocardial infarction), blood flow velocities through the LVOT were recorded using conventional pulsed Doppler. The LVOT(Acc) was calculated as the aortic peak velocity divided by the time to peak flow; LVOT(Acc) was compared with LV maximal elastance (E(m)) acquired by conductance catheter under different loading conditions, including volume and pressure overload during an acute coronary occlusion (n = 10). In addition, a clinically validated lumped-parameter numerical model of the cardiovascular system was used to support our findings. RESULTS: Left ventricular E(m) and LVOT(Acc) decreased during ischemia (1.67 +/- 0.67 mm Hg.ml(-1) before vs. 0.93 +/- 0.41 mm Hg.ml(-1) during acute coronary occlusion [p < 0.05] and 7.9 +/- 3.1 m.s(-2) before vs. 4.4 +/- 1.0 m.s(-2) during coronary occlusion [p < 0.05], respectively). Left ventricular outflow tract systolic acceleration showed a strong linear correlation with LV E(m) (y = 3.84x + 1.87, r = 0.85, p < 0.001). Similar findings were obtained with the numerical modeling, which demonstrated a strong correlation between predicted and actual LV E(m) (predicted = 0.98 [actual] -0.01, r = 0.86). By analysis of variance, there was no statistically significant difference in LVOT(Acc) under different loading conditions. CONCLUSIONS: For a variety of hemodynamic conditions, LVOT(Acc) was linearly related to the LV contractility index LV E(m) and was independent of loading conditions. These findings were consistent with numerical modeling. Thus, this Doppler index may serve as a good noninvasive index of LV contractility.

Acceleration↗

A new dynamic three-dimensional digital color doppler method for quantification of pulmonary regurgitation: validation study in an animal model.

OBJECTIVES: The purpose of the present study was to validate a newly developed three-dimensional (3D) digital color Doppler method for quantifying pulmonary regurgitation (PR), using an animal model of chronic PR. BACKGROUND: Spectral Doppler methods cannot reliably be used to assess pulmonary regurgitation. METHODS: In eight sheep with surgically created PR, 27 different hemodynamic states were studied. Pulmonary and aortic electromagnetic (EM) probes and meters were used to provide reference right ventricular (RV) forward and pulmonary regurgitant stroke volumes. A multiplane transesophageal probe was placed directly on the RV and aimed at the RV outflow tract. Electrocardiogram-gated and rotational 3D scans were performed for acquiring dynamic 3D digital velocity data. After 3D digital Doppler data were transferred to a computer workstation, the RV forward and pulmonary regurgitant flow volumes were obtained by a program that computes the velocity vectors over a spherical surface perpendicular to the direction of scanning. RESULTS: Pulmonary regurgitant volumes and RV forward stroke volumes computed by the 3D method correlated well with those by the EM method (r = 0.95, mean difference = 0.51 +/- 1.89 ml/beat for the pulmonary regurgitant volume; and r = 0.91, mean difference = -0.22 +/- 3.44 ml/beat for the RV stroke volume). As a result of these measurements, the regurgitant fractions derived by the 3D method agreed well with the reference data (r = 0.94, mean difference = 2.06 +/- 6.11%). CONCLUSIONS: The 3D digital color Doppler technique is a promising method for determining pulmonary regurgitant volumes and regurgitant fractions. It should have an important application in clinical settings.

Animals↗

Direct quantification of transmitral flow volume with dynamic 3-dimensional digital color Doppler: a validation study in an animal model.

Accurately quantifying transmitral flow volume is clinically important not only as a measure of cardiac output, but also as a value from which to subtract aortic flow, for determining the severity of mitral regurgitation. However, controversy exists over the accuracy of pulsed Doppler for mitral flow quantification because of the complexity of mitral flow geometry and dynamic changes in flow profile and flow area. To explore the feasibility of directly quantifying transmitral flow volume with a newly developed dynamic 3-dimensional digital color Doppler technique, this in vivo experimental study was conducted to validate the method. Eight open chest sheep were imaged with a multiplane transesophageal (TEE) probe placed on the heart for digital 3-dimensional gated acquisition of mitral inflow over a 180-degree acquisition. The digital velocity data were contour detected for flow area after computing the velocity vectors and flow profile perpendicular to a spherical 3-dimensional surface across the mitral annulus. Flow areas and actual velocities were then integrated in time and space and the resulting flow volumes were compared with those obtained by a reference electromagnetic flowmeter on the aorta for 26 steady hemodynamic states. The flow volumes correlated closely to the electromagnetic references (y = 0.87x + 2.49, r = 0.92, SEE = 1.9 Ml per beat). Our study shows that transmitral flow volume can be accurately determined in vivo by this dynamic 3-dimensional digital color Doppler flow quantification method.

Animals↗

Quantitative assessment of left ventricular perfusion defects using real-time three-dimensional myocardial contrast echocardiography.

Quantitative assessment of perfusion defects with myocardial contrast echocardiography can be a valuable tool in the evaluation of patients with coronary artery disease. However, the use of 2-dimensional echocardiography for this purpose is limited to a restricted number of imaging planes. Real-time 3-dimensional echocardiography (RT3D) is a novel technique that provides instantaneous volumetric images. The aim of this study was to validate the use of RT3D for the quantitative assessment of myocardial perfusion defects in a model of acute coronary occlusion. To this end, 20 sheep underwent acute ligation of the left anterior descending (n = 14) or the posterior branch of the circumflex (n = 6) artery under general anesthesia. The RT3D images were obtained after left atrial injection of the contrast agent EchoGen (perflenapent emulsion; 0.8-1 mL). Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. The mass of the entire left ventricle and of the underperfused myocardial region were measured after death. Blinded off-line calculation of left ventricular (LV) mass and perfusion-defect mass from RT3D images were performed using an interactive aided-manual tracing technique. Total LV mass ranged from 68 to 141 g (mean plus minus SD: 92 +/- 24 g). The mass of the perfusion defect ranged from 0 to 43 g (mean +/- SD: 16 +/- 9 g) or 0 to 36% of total LV mass (mean +/- SD: 18% +/- 9%). The RT3D estimation of total LV mass strongly correlated with the anatomic measurement (r = 0.91; y = -2.54 + 1.04x; standard error of the estimate [SEE] = 11.9 g). The RT3D calculation of the mass of underperfused myocardium also strongly correlated with the anatomic measurement, both in absolute terms (r = 0.96; y = 2.01 + 0.87x; SEE = 2.2 g) and when expressed as percentage of total LV mass (r = 0.96; y = 0.11 + 1.02x; SEE = 2.8%). Hence, RT3D with myocardial contrast opacification accurately predicts the amount of underperfused myocardium in an animal model of acute coronary occlusion. This technique may therefore be useful for the quantitative assessment of myocardial perfusion defects in patients with coronary artery disease.

Animals↗

Quantitative analysis of aortic regurgitation: real-time 3-dimensional and 2-dimensional color Doppler echocardiographic method--a clinical and a chronic animal study.

BACKGROUND: For evaluating patients with aortic regurgitation (AR), regurgitant volumes, left ventricular (LV) stroke volumes (SV), and absolute LV volumes are valuable indices. AIM: The aim of this study was to validate the combination of real-time 3-dimensional echocardiography (3DE) and semiautomated digital color Doppler cardiac flow measurement (ACM) for quantifying absolute LV volumes, LVSV, and AR volumes using an animal model of chronic AR and to investigate its clinical applicability. METHODS: In 8 sheep, a total of 26 hemodynamic states were obtained pharmacologically 20 weeks after the aortic valve noncoronary (n = 4) or right coronary (n = 4) leaflet was incised to produce AR. Reference standard LVSV and AR volume were determined using the electromagnetic flow method (EM). Simultaneous epicardial real-time 3DE studies were performed to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV), and LVSV by subtracting LVESV from LVEDV. Simultaneous ACM was performed to obtain LVSV and transmitral flows; AR volume was calculated by subtracting transmitral flow volume from LVSV. In a total of 19 patients with AR, real-time 3DE and ACM were used to obtain LVSVs and these were compared with each other. RESULTS: A strong relationship was found between LVSV derived from EM and those from the real-time 3DE (r = 0.93, P <.001, mean difference (3D - EM) = -1.0 +/- 9.8 mL). A good relationship between LVSV and AR volumes derived from EM and those by ACM was found (r = 0.88, P <.001). A good relationship between LVSV derived from real-time 3DE and that from ACM was observed (r = 0.73, P <.01, mean difference = 2.5 +/- 7.9 mL). In patients, a good relationship between LVSV obtained by real-time 3DE and ACM was found (r = 0.90, P <.001, mean difference = 0.6 +/- 9.8 mL). CONCLUSION: The combination of ACM and real-time 3DE for quantifying LV volumes, LVSV, and AR volumes was validated by the chronic animal study and was shown to be clinically applicable.

Adult↗

A validation study of aortic stroke volume using dynamic 4-dimensional color Doppler: an in vivo study.

OBJECTIVE: To explore the feasibility of directly quantifying transaortic stroke volume with a newly developed dynamic 3-dimensional (3D) color Doppler flow measurement technique, an in vivo experimental study was performed. BACKGROUND: Traditional methods for flow quantification require geometric assumptions about flow area and flow profiles. Accurate quantification of flow across the aortic valve is clinically important as a means of estimating cardiac output. METHODS: Eight open-chest sheep were scanned with apical epicardial placement of a 7 to 4 MHz multiplane transesophageal probe scanning parallel to aortic flow and running on an ATL HDI 5000 system. An electromagnetic flow meter implanted on the ascending aorta was used as reference. Thirty different hemodynamic conditions were studied after steady states were obtained in the animals by administration of blood, angiotensin, and sodium nitroprusside. Electrocardiogram-gated digital color 3D velocity data were acquired for each of the 30 steady states. The aortic stroke volumes were computed by temporal and spatial integration of flow areas and actual velocities across a projected surface perpendicular to the direction of flow, at a level just below the aortic valve. RESULTS: There was close correlation between the 3D color Doppler calculated aortic stroke volumes and the electromagnetic data (r = 0.91, y = 0.96x + 1.01, standard error of the estimate = 2.6 mL/beat). CONCLUSION: Our results showed that dynamic 3D color Doppler measurements obtained in an open-chest animals provide the basis for accurate, geometry-independent quantitative evaluation of the aortic flow. Therefore, 3D digital color Doppler flow computation could potentially represent an important method for noninvasively determining cardiac output in patients.

Animals↗

Pulmonary venous flow determinants of left atrial pressure under different loading conditions in a chronic animal model with mitral regurgitation.

BACKGROUND: The aim of our study was to quantitatively compare the changes and correlations between pulmonary venous flow variables and mean left atrial pressure (mLAP) under different loading conditions in animals with chronic mitral regurgitation (MR) and without MR. METHODS: A total of 85 hemodynamic conditions were studied in 22 sheep, 12 without MR as control (NO-MR group) and 10 with MR (MR group). We obtained pulmonary venous flow systolic velocity (Sv) and diastolic velocity (Dv), Sv and Dv time integrals, their ratios (Sv/Dv and Sv/Dv time integral), mLAP, left ventricular end-diastolic pressure, and MR stroke volume. We also measured left atrial a, x, v, and y pressures and calculated the difference between v and y pressures. RESULTS: Average MR stroke volume was 10.6 +/- 4.3 mL/beat. There were good correlations between Sv (r = -0.64 and r = -0.59, P <.01), Sv/Dv (r = -0.62 and r = -0.74, P <.01), and mLAP in the MR and NO-MR groups, respectively. Correlations were also observed between Dv time integral (r = 0.61 and r = 0.57, P <.01) and left ventricular end-diastolic pressure in the MR and NO-MR groups. In velocity variables, Sv (r = -0.79, P <.001) was the best predictor of mLAP in both groups. The sensitivity and specificity of Sv = 0 in predicting mLAP 15 mm Hg or greater were 86% and 85%, respectively. CONCLUSION: Pulmonary venous flow variables correlated well with mLAP under altered loading conditions in the MR and NO-MR groups. They may be applied clinically as substitutes for invasively acquired indexes of mLAP to assess left atrial and left ventricular functional status.

Animals↗

Proteomic technologies to study diseases of the lymphatic vascular system.

Now that the human genome has been mapped, a new challenge has emerged: deciphering the various products of individual genes. Consequently, new proteomic technologies are being developed to monitor and identify protein function and interactions responsible for the total activities of the cell. The application of these new proteomic technologies to study cellular activities, will lead to a faster sample throughput and increased sensitivity for the detection of individual proteins, thus providing major opportunities for the discovery of new biomarkers for the early detection of protein alterations associated with the progression of the disease state.

Animals↗

Dietary administration of colesevelam hydrochloride does not affect fertility or reproductive performance in rats.

Colesevelam hydrochloride (HCl) (WelChol; Sankyo Pharma) is a novel, highly potent, bile acid-binding polymer used for the treatment of hypercholesterolemia. The primary aim of this study was to determine the effects of dietarily administered colesevelam HCl on fertility and reproductive performance parameters. To assess these effects, sexually mature Sprague-Dawley rats were randomized to one of five treatment groups: feed alone, feed plus control article (SigmaCell), or feed plus colesevelam HCl 200, 1000, or 2000 mg/kg/day. Male and female rats were administered the appropriate group agent for 28 and 15 days, respectively, and were subsequently paired together for cohabitation and mating. Females continued to receive the test agent in their dietary formulation through presumed gestation day (GD) 7. Presumed pregnant females underwent cesarean section on GD 20. Food consumption rate, body weight, gross necropsy, and standard preclinical tests for reproduction and fertility were performed for each test animal. No statistically significant differences were found between control and drug-treated groups for any tested endpoints of reproduction. All animals placed in cohabitation successfully mated. Uterine and litter end points were unaffected by dosages of colesevelam HCl as high as 2000 mg/kg/day. There were no significant differences between treatment group litter averages in the number of corpora lutea, implantation sites, litter size, live fetuses, body weights, early/late resorptions, and the number of dams with viable fetuses. In addition, no external alterations of fetal morphology were attributable to treatment with colesevelam HCl when administered up to the embryo implantation stage. In male animals, no significant differences were found between the colesevelam HCl and control study groups in the average caudal epididymal sperm count or sperm concentration, total number of motile and nonmotile sperm, and the total percentage of motile sperm. Based on these data, colesevelam HCl does not have any significant adverse reproductive or fertility effects in rats, even when administered at doses approximately 30 times greater than the approved clinical dose.

Administration, Oral↗

Evaluation of heat shock protein 70 as a biomarker of environmental stress in Fucus serratus and Lemna minor.

Heat shock proteins (Hsps) are known to be induced in response to short-term stress. The present study aimed to evaluate the potential of Hsp70 as a biomarker of stress produced by increased temperature, osmotic pressure, and exposure to cadmium and sodium chloride in marine macroalgae and fresh water plant species. An indirect competitive enzyme-linked immunosorbent assay (IC-ELISA) was developed with a working range of 0.025-10 microg ml(-1) using a monoclonal antibody raised against purified Hsp70 of Phaseolus aureus (mung bean). Fucus serratus (toothed wrack), Chondrus crispus (Stackhouse or Carrageen moss), Ulva lactuca (sea lettuce) and Lemna minor (common duckweed) sample extracts were stressed for up to 24 h and then tested in the IC-ELISA. The presence of Hsp70 and cross-reactivity of the monoclonal antibody was confirmed by Western blot. The heat shock response was confirmed in each species using a 2-h 42 degrees C treatment. Following heat shock, Hsp70 concentrations increased to a peak at 2 h (F. serratus) or 4 h (L. minor), after which concentrations decreased. Osmotic and cadmium stresses also resulted in elevated Hsp70 concentrations in samples of F. serratus and L. minor when compared with unstressed controls. In both, osmotic and metal stress, the production of Hsp70 increased to a maximum and subsequently decreased as the stressor levels increased. Results suggest that Hsp70 IC-ELISA could potentially be applied to the detection of stress in these aquatic species, although it would probably be most effective when used in conjunction with other measurements to provide a stressor-specific biomarker profile or fingerprint.

Antibodies, Monoclonal↗