The effect of the z-flying focal spot (zFFS) technology was evaluated by simulations and measurements with respect to resolution and artifact behavior for a 64-slice spiral cone-beam computed tomography (CT) scanner. The zFFS alternates between two z-positions of the X-ray focal spot, acquiring two slices per detector row, which results in double sampling in the z-direction. We implemented a modified reconstruction that is able to obtain images as they would be without zFFS. A delta phantom equipped with a thin gold disc was used to measure slice sensitivity profiles (SSP), and a high-contrast bar phantom was used to quantify the resolution in the x/z-plane with and without zFFS. The zFFS decreases the full width at half maximum (FWHM) of the SSPs by a factor of about 1.4. The double z-sampling allows the separation of 0.4 mm bars in the z-direction compared with 0.6 mm in the case without zFFS. The zFFS effectively reduces windmill artifacts in the reconstructed images while maintaining the transverse resolution, even at the largest available pitch value of 1.5.

Artifacts↗

Multithreaded cardiac CT.

Phase-correlated CT, as it is used for cardiac imaging, is the most popular and the most important but also the most demanding special CT application in the clinical routine, today. Basically, it fulfills the four-dimensional imaging task of depicting a quasiperiodically moving object at any desired motion phase with significantly reduced motion artifacts. Although image quality with phase-correlated reconstruction is far better than with standard reconstruction, there are motion artifacts remaining and improvements of temporal resolution are required. As a well-known alternative to simply decreasing rotation time, we consider a spiral cone-beam CT scanner that has G x-ray guns and detectors mounted. We call this a multisource or a multithreaded CT scanner. Aiming for improved temporal resolution the relative temporal resolution tau, which measures the fraction of a motion period that enters the image, is studied as a function of the motion rate (heart rate) and the degree of scan overlap (pitch value) for various configurations. The parameters to optimize are the number of threads G and the interthread parameters delta alpha and delta z, which are the angular and the longitudinal separation between adjacent threads, respectively. To demonstrate the improvements approximate image reconstruction of multithreaded raw data is performed by using a generalization of the extended parallel back projection cone-beam reconstruction algorithm [Med. Phys. 31(6), 1623-1641 (2004)] to the case of multithreaded CT. Reconstructions of a simulated cardiac motion phantom and of simulated semi-antropomorphic phantoms are presented for two and three threads and compared to the single-threaded case to demonstrate the potential of multithreaded cardiac CT. Patient data were acquired using a clinical double-threaded CT scanner to validate the theoretical results. The optimum angle delta alpha between the tubes is 90 degrees for a double-threaded system, and for triple-threaded scanners it is 60 degrees or 120 degrees. In all cases, delta z = 0 results as an optimum, which means that the threads should be mounted in the same transversal plane. However, the dependency of the temporal resolution on delta z is very weak and a longitudinal separation delta z not = 0 would not deteriorate image quality. The mean temporal resolution achievable with an optimized multithreaded CT scanner is a factor of G better than the mean temporal resolution obtained with a single-threaded scanner. The standard reconstructions showed decreased cone-beam artifacts with multithreaded CT compared to the single-threaded case. Our phase-correlated reconstructions demonstrate that temporal resolution is significantly improved with multithreaded CT. The clinical patient data confirm our results.

Algorithms↗

Extended parallel backprojection for standard three-dimensional and phase-correlated four-dimensional axial and spiral cone-beam CT with arbitrary pitch, arbitrary cone-angle, and 100% dose usage.

We have developed a new approximate Feldkamp-type algorithm that we call the extended parallel backprojection (EPBP). Its main features are a phase-weighted backprojection and a voxel-by-voxel 180 degrees normalization. The first feature ensures three-dimensional (3-D) and 4-D capabilities with one and the same algorithm; the second ensures 100% detector usage (each ray is accounted for). The algorithm was evaluated using simulated data of a thorax phantom and a cardiac motion phantom for scanners with up to 256 slices. Axial (circle and sequence) and spiral scan trajectories were investigated. The standard reconstructions (EPBPStd) are of high quality, even for as many as 256 slices. The cardiac reconstructions (EPBPCI) are of high quality as well and show no significant deterioration of objects even far off the center of rotation. Since EPBPCI uses the cardio interpolation (CI) phase weighting the temporal resolution is equivalent to that of the well-established single-slice and multislice cardiac approaches 180 degrees CI, 180 degrees MCI, and ASSRCI, respectively, and lies in the order of 50 to 100 ms for rotation times between 0.4 and 0.5 s. EPBP appears to fulfill all required demands. Especially the phase-correlated EPBP reconstruction of cardiac multiple circle scan data is of high interest, e.g., for dynamic perfusion studies of the heart.

Algorithms↗