PubMed Health⌕ Search

Biomedical subjects

Michael L G Joy

Publications and source records attributed to Michael L G Joy.

3 recordsLinked to original sources

Current density imaging and electrically induced skin burns under surface electrodes.

The origin of electrical burns under gel-type surface electrodes is a controversial topic that is not well understood. To investigate the phenomenon, we have developed an excised porcine skin-gel model, and used low-frequency current density imaging (LFCDI) to determine the current density (CD) distribution through the skin before and after burns were induced by application of electrical current (200 Hz, 70% duty cycle, 20-35 mA monophasic square waveform applied to the electrodes for 30-135 min). The regions of increased CD correlate well with the gross morphological changes (burns) observed. The measurement is sensitive enough to show regions of high current densities in the pre-burn skin, that correlate with areas were burn welts were produced, thus predicting areas where burns are likely to occur. Statistics performed on 28 skin patches revealed a charge dependency of the burn areas and a relatively uniform distribution. The results do not support a thermal origin of the burns but rather electro-chemical mechanisms. We found a statistically significant difference between burn area coverage during anodic and cathodic experiments.

Animals↗

Measurement of thoracic current flow in pigs for the study of defibrillation and cardioversion.

Although defibrillation has been in clinical use for more than 50 years, the complete current flow distribution inside the body during a defibrillation procedure has never been directly measured. This is due to the lack of appropriate imaging technology to noninvasively monitor the current flow inside the body. The current density imaging (CDI) technique, using a magnetic resonance (MR) imager, provides a new approach to this problem [Scott et al. (1991)]. CDI measures the local magnetic field generated by the current and calculates the current density by computing its curl. In this study, CDI was used to measure current density at all points within a postmortem pig torso during an electrical current application through defibrillation electrodes. Furthermore, current flow information was visualized along the chest wall and within the chest cavity using streamline analysis. As expected, some of the highest current densities were observed in the chest wall. However, current density distribution varied significantly from one region to another, possibly reflecting underlying heterogeneous tissue conductivity and anisotropy. Moreover, the current flow analysis revealed many complex and unexpected current flow patterns that have never been observed before. This study has, for the first time, noninvasively measured the volume current measurement inside the pig torso.

Animals↗

Why does MTR change with neuronal depolarization?

T1 and T2 relaxation, and magnetization transfer (MT) of the rat brain were measured during experimentally induced spreading depression (SD). All measured MR parameters changed during SD: T1 relaxation increased by approximately 13%, whereas the T2 increase was substantially larger (88%). MT results showed an MT ratio (MTR) decrease of 9%. The lack of change in the MT exchange rate indicated that the MT processes between water and macromolecular protons are not affected by neuronal depolarization. The observed decrease in MTR was only caused by changes in T1 and T2 relaxation.

Animals↗