PubMed Health⌕ Search

Biomedical subjects

Michael Lell

Publications and source records attributed to Michael Lell.

5 recordsLinked to original sources

Improvement of image quality of multislice spiral CT scans of the head and neck region using a raw data-based multidimensional adaptive filtering (MAF) technique.

The purpose was to evaluate the potential of the multidimensional adaptive filtering (MAF) technique by investigating its effects on image noise and image quality in multislice spiral CT (MSCT) examinations of the head and neck region. Fifty patients with head and neck tumors were examined using MSCT with a high resolution protocol. Reconstructions were performed using dedicated reconstruction software with a standard algorithm both without and with MAF using different modification. In all reconstructions, we measured the noise in seven different anatomical structures. The image quality and image noise were rated on a five-point scale. There was a significant (P<0.05) reduction in mean pixel noise in the reconstructions using MAF in comparison to the standard reconstructions, but there was no significant difference between the different modification fractions. With MAF the mean reduction in noise level was 60%, depending upon body shape and anatomical region. Independently from the used modification fraction, MAF led to a significant (P<0.05) improvement of image quality. In direct comparison of the different filter strength, the optimal image quality was achieved in the investigations with 15% MAF. The use of MAF facilitates the distinction of anatomical and pathological structures from artifacts in the supraclavicular fossae and the upper mediastinum, whereas the image quality of the upper portions of the neck remained unchanged. MAF improved image quality by reducing the noise level and removing noise structures without loss of image sharpness. This technique offers new perspectives to reduce the patient dose.

Adipose Tissue↗

COMPARE radiology: creating an interactive Web-based training program for radiology with multimedia authoring software.

RATIONALE AND OBJECTIVES: Computer-based training has two primary benefits: Content can be presented interactively, and students can choose the time, place, and pace of learning. As a subject of medical education, radiology lends itself particularly well to computer-based training because of its highly visual content. To improve the efficiency of radiology training at their institution, the authors decided to create an interactive Web-based training site. MATERIALS AND METHODS: Working with a group of medical students knowledgeable in multimedia authoring, the authors used authoring software to create "COMPARE Radiology," an interactive training program that follows the modality-based structure of the undergraduate curriculum for radiology at the University of Erlangen-Nuremberg, Erlangen, Germany, and at medical schools worldwide. RESULTS: The Web-based program offers cases and exercises in radiographic anatomy at different selectable levels of difficulty, allowing users to test and build their knowledge of radiology. Pathologic images are initially presented without any further information. Additional information (patient history, laboratory results, reports from other imaging studies, and normal images for comparison) can be retrieved selectively and successively. Further information regarding the diagnosis and pathologic findings can be found by following links to external Web sites. The COMPARE Radiology program content is extended and updated regularly. The program is subject to internal peer review and can be evaluated by the user online. CONCLUSION: The authors' experience shows that a highly interactive Web-based training program for radiology, tailored to the requirements of the target group, can be developed economically by a team of medical students using an advanced storing system, with the guidance of a radiologist and without the help of professionally trained computer experts.

Computer-Assisted Instruction↗

Anatomic site evaluation of the zygomatic bone for dental implant placement.

Thirty human zygomatic bone specimens (15 females mean age 81.60 +/- 11.38 years, 15 males, mean age 78.47 +/- 6.58 years) were examined by quantitative computed tomography and histomorphometry. The aim of the study was to assess the bone mineral density, the trabecular bone volume and the trabecular bone pattern factor. Moreover, the anterior-posterior and the medio-lateral dimensions and the estimated implant length within the zygomatic bone were determined. For quantitative computed tomography the specimens were scanned together with a bone mimicking anthropomorphic reference phantom. The bone mineral density was calculated for the specimens in the plane of the intended direction of the implant placement. Subsequently, with the sawing and grinding technique, the specimens were prepared in the same plane for histomorphometry. The trabecular bone mineral density was 369.95 +/- 188.80 mg/cm3 for the female and 398.94 +/- 99.11 mg/cm3 for the male specimens (P = 0.23). The male trabecular bone volume showed a value of 27.32 +/- 9.49%, while the female group reached a value of 19.99 +/- 7.60% (P = 0.23). The trabecular bone pattern factor was 1.2 x 10-2 +/- 1.28 mm-1 for the male and 1.02 +/- 0.96 mm-1 for the female specimens (P = 0.045). The study reveals that the zygomatic bone consists of trabecular bone with parameters that are unfavourable for implant placement. However, the success of implants placed in the zygomatic bone is secured by the employment of at least four cortical portions.

Aged↗

Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose).

In a controlled patient study we investigated the potential of attenuation-based on-line modulation of the tube current to reduce milliampere values (mAs) in CT examinations of children without loss of image quality. mAs can be reduced for non-circular patient cross sections without an increase in noise if tube current is reduced at those angular positions where the patient diameter and, consequently, attenuation are small. We investigated a technical approach with an attenuation-based on-line control for the tube current realised as a work-in-progress implementation. The CT projection data are analysed in real time to determine optimal mAs values for each projection angle. We evaluated mAs reduction for 100 spiral CT examinations with attenuation-based on-line modulation of the tube current in a group of children. Two radiologists evaluated image quality by visual interpretation in consensus. We compared the mAs values read from the CT scanner with preset mAs of a standard protocol. Four different scan regions were examined in spiral technique (neck, thorax, abdomen, thorax and abdomen). We found the mAs product to be reduced typically by 10-60% depending on patient geometry and anatomical regions. The mean reduction was 22.3% (neck 20%, thorax 23%, abdomen 23%, thorax and abdomen 22%). In general, no deterioration of image quality was observed. There was no correlation between the age and the mean mAs reduction in the different anatomical regions. By classifying the children respectively to their weight, there is a positive trend between increasing weight and mAs reduction. We conclude that mAs in spiral CT examinations of children can be reduced substantially by attenuation-based on-line modulation of the tube current without deterioration of image quality. Attenuation-based on-line modulation of tube current is efficient and practical for reducing dose exposure to children.

Adolescent↗

High-resolution, contrast-enhanced magnetic resonance angiography with elliptical centric k-space ordering of supra-aortic arteries compared with selective X-ray angiography.

BACKGROUND AND PURPOSE: The objective of this study was to evaluate the relative value of high-resolution, contrast-enhanced MR angiography (CE MRA) with elliptical centric k-space ordering compared with intra-arterial x-ray angiography for imaging carotid stenosis. METHODS: Thirty patients with suspected stenosis of the carotid arteries were examined with CE MRA (1.5-T scanner) and x-ray angiography (aortic arch survey and selective imaging of both common carotid arteries). For the first time, not only the extracranial carotid bifurcation but all the vessel segments from the aortic arch to the circle of Willis were assessed by independent investigators. RESULTS: For the internal carotid artery in the region of the extracranial carotid bifurcation, there was a very close correlation between CE MRA and x-ray angiography (sensitivity, 100%; specificity, 92%). The initially suspected overestimation of stenosis on CE MRA in 3 cases was ultimately revealed to be an underestimation on x-ray angiography. CE MRA showed slightly poorer imaging of the basal vessel segments at the level of the aortic arch (because of breathing artifacts) and the intracranial vessel segments (because of small vessel caliber and venous superimposition due to delayed sequence starts). CONCLUSIONS: The MRA technique described here provides reliable results in the diagnosis of carotid stenosis and is thus suitable for replacing the invasive conventional x-ray angiography method in most cases. Further technical developments with regard to spatial resolution are still required for improved visualization of small vessels (terminal carotid branches and intracranial vessels).

Aged↗