PubMed Health⌕ Search

Biomedical subjects

Michael Mix

Publications and source records attributed to Michael Mix.

9 recordsLinked to original sources

[Image reconstruction and quantification in emission tomography].

Radionuclide tomographic imaging has substantially benefited from the introduction of statistical image reconstruction. Although the main concepts of these iterative algorithms were published decades ago, their widespread use in clinical routine only became available with faster computers for image processing in the last few years. This article gives an overview of data acquisition and iterative reconstruction in emission tomography, deals with the popular maximum likelihood algorithm, and describes the basics of the maximum a posteriori reconstruction. Prerequisites and corrections necessary for quantification are discussed in the second part of the article on the basis of positron emission tomography. Improvements in technical equipment are expected to stimulate future research into image reconstruction.

Humans↗

Positron emission tomography-measured abnormal responses of myocardial blood flow to sympathetic stimulation are associated with the risk of developing cardiovascular events.

OBJECTIVES: We sought to assess prospectively whether patients with normal coronary angiograms but with impaired myocardial blood flow (MBF) increases to cold pressor testing (CPT) are at increased risk for cardiovascular events. BACKGROUND: Invasive angiographic assessments of coronary vasomotor function have demonstrated an impairment of endothelium-related coronary flow increases to independently predict future cardiovascular events. It is unknown whether noninvasive positron emission tomography (PET)-measured MBF alterations to sympathetic stimulation with CPT are associated with the risk of developing cardiovascular events. METHODS: A total of 72 patients (44 men, 28 women, age 58 +/- 8 years) referred for diagnostic cardiac catheterization were studied. Myocardial blood flow was measured in absolute units with (13)N-ammonia using PET, at baseline and during CPT in each patient. Cardiovascular events (cardiovascular death, acute coronary syndrome, myocardial infarction, percutaneous transluminal coronary angioplasty, coronary artery bypass grafting, ischemic stroke, or peripheral revascularization) were assessed as clinical outcome parameters over a mean follow-up period of 66 +/- 8 months. Patients were assigned to three groups: group 1, patients with >/=40% increase in MBF (%DeltaMBF), n = 22; group 2, patients with >0 and <40% increases in MBF, n = 32; and group 3, patients with decreases in MBF (</=0%), n = 18. RESULTS: During follow-up, one of the group 1 patients developed a cerebral stroke. In group 2, 15 cardiovascular events occurred in 9 patients and in group 3, 7 patients experienced 9 cardiovascular events (p </= 0.0001, univariate by log-rank test). Impaired MBF increases in group 2 and group 3 were associated with a significantly higher incidence of cardiovascular events by Kaplan-Meier analysis (p = 0.033, log-rank test). After adjusting for known coronary risk factors, MBF responses to CPT revealed a nonsignificant trend to be independently associated with a higher incidence for cardiovascular events (p = 0.065, multivariate by Cox regression model). CONCLUSIONS: Noninvasive PET-measured impaired MBF increases to sympathetic stimulation are associated with the risk of developing cardiovascular events.

Ammonia↗

Can body volume be determined by PET?

PURPOSE: To avoid dependence on body weight, the standardised uptake value (SUV) in positron emission tomography (PET) can instead be normalised to the lean body mass (LBM), which can be determined from body volume and mass. This study was designed to answer the following questions: Firstly, can the total body volume in principle be determined using PET? Secondly, is the precision of this measurement comparable to that achieved using an established standard method. METHODS: Ten patients were examined during oncological whole-body PET examinations. The whole-body volume of the patients was determined from the transmission scan in PET. Air displacement plethysmography with BOD POD was used for comparison as the standard method of volume determination. RESULTS: In all patients, the whole-body volumes could be determined using PET and the standard method. Bland and Altman [23] analysis for agreement between the volumes determined by the two methods (presentation of differences vs means) revealed a very small difference of -0.14 l. With a mean patient volume of 71.81+/-15.93 l, the relative systematic error is only <0.1%. On this basis, equality of the volume values determined by the two methods can be assumed. CONCLUSION: PET can be used as a supplementary method for experimental determination of whole-body volume and total body fat in tumour patients. The fat content can be used to calculate the LBM and to determine body weight-independent SUVs (SUV(LBM)).

Anthropometry↗

Chronic inflammation and impaired coronary vasoreactivity in patients with coronary risk factors.

BACKGROUND: The goal of this study was to examine a possible association between systemic microinflammation, as reflected by C-reactive protein (CRP) serum levels, and coronary vasomotion in patients with coronary risk factors but with angiographically normal coronary arteries. METHODS AND RESULTS: Coronary vasomotor function was studied in response to cold pressor testing (CPT) in 71 patients with normal angiograms. In all patients, CPT-induced changes in epicardial luminal area (LA; mm2) were assessed with quantitative angiography. Within 20 days, myocardial blood flow (MBF) responses to CPT were measured (mL x g(-1) x min(-1)) noninvasively with 13N-ammonia and PET imaging. The CPT-induced mean changes in LA and in MBF in patients with elevated CRP (> or =0.5 mg/dL) were significantly impaired compared with patients presenting with CRP levels within normal range (<0.5 mg/dL) (DeltaLA, -1.09+/-0.86 versus 0.45+/-0.63 mm2; DeltaMBF, 0.06+/-0.18 versus 0.44+/-0.31 mL x g(-1) x min(-1); P<0.0001, respectively). Coronary LA changes and MBF responses to CPT were inversely correlated with CRP serum levels (r=-0.84 and r=-0.63; P<0.0001). Lastly, regression analysis revealed a significant correlation between the changes in LA and MBF during CPT for patients with elevated CRP levels and those for patients with normal CRP levels (r=0.56 and r=0.66; P<0.001). CONCLUSIONS: These findings suggest a direct association between systemic microinflammation and altered coronary vasomotor function of both the epicardial conductance and the arteriolar resistance vessels.

Aged↗

PET-measured responses of MBF to cold pressor testing correlate with indices of coronary vasomotion on quantitative coronary angiography.

UNLABELLED: The aims of this study were to determine whether responses in myocardial blood flow (MBF) to the cold pressor testing (CPT) method noninvasively with PET correlate with an established and validated index of flow-dependent coronary vasomotion on quantitative angiography. METHODS: Fifty-six patients (57 +/- 6 y; 16 with hypertension, 10 with hypercholesterolemia, 8 smokers, and 22 without coronary risk factors) with normal coronary angiograms were studied. Biplanar end-diastolic images of a selected proximal segment of the left anterior descending artery (LAD) (n = 27) or left circumflex artery (LCx) (n = 29) were evaluated with quantitative coronary angiography in order to determine the CPT-induced changes of epicardial luminal area (LA, mm(2)). Within 20 d of coronary angiography, MBF in the LAD, LCx, and right coronary artery territory was measured with (13)N-ammonia and PET at baseline and during CPT. RESULTS: CPT induced on both study days comparable percent changes in the rate x pressure product (%DeltaRPP, 37% +/- 13% and 40% +/- 17%; P = not significant [NS]). For the entire study group, the epicardial LA decreased from 5.07 +/- 1.02 to 4.88 +/- 1.04 mm(2) (DeltaLA, -0.20 +/- 0.89 mm(2)) or by -2.19% +/- 17%, while MBF in the corresponding epicardial vessel segment increased from 0.76 +/- 0.16 to 1.03 +/- 0.33 mL x min(-1) x g(-1) (DeltaMBF, 0.27 +/- 0.25 mL x min(-1) x g(-1)) or 36% +/- 31% (P <or= 0.0001). However, in normal controls without coronary risk factors (n = 22), the epicardial LA increased from 5.01 +/- 1.07 to 5.88 +/- 0.89 mm(2) (19.06% +/- 8.9%) and MBF increased from 0.77 +/- 0.16 to 1.34 +/- 0.34 mL x min(-1) x g(-1) (74.08% +/- 23.5%) during CPT, whereas patients with coronary risk factors (n = 34) revealed a decrease of epicardial LA from 5.13 +/- 1.48 to 4.24 +/- 1.12 mm(2) (-15.94% +/- 12.2%) and a diminished MBF increase (from 0.76 +/- 0.20 to 0.83 +/- 0.25 mL x min(-1) x g(-1) or 10.91% +/- 19.8%) as compared with controls (P < 0.0001, respectively), despite comparable changes in the RPP (P = NS). In addition, there was a significant correlation (r = 0.87; P <or= 0.0001) between CPT-related percent changes in LA on quantitative angiography and in MBF as measured with PET. CONCLUSION: The observed close correlation between an angiographically established parameter of flow-dependent and, most likely, endothelium-mediated coronary vasomotion and PET-measured MBF further supports the validity and value of MBF responses to CPT as a noninvasively available index of coronary circulatory function.

Blood Flow Velocity↗

Coronary vasoregulation in patients with various risk factors in response to cold pressor testing: contrasting myocardial blood flow responses to short- and long-term vitamin C administration.

OBJECTIVES: We sought to determine whether abnormal myocardial blood flow (MBF) responses to the cold pressor test (CPT) in patients with various risk factors may involve different mechanisms that could lead to varying responses of short- and long-term administration of antioxidants. BACKGROUND: There is a growing body of evidence that increased vascular production of reactive oxygen species markedly reduces the bioavailability of endothelium-derived nitric oxide, leading to impaired vasodilator function. It is unknown whether increased oxidative stress is the prevalent mechanism underlying endothelial dysfunction in patients with different coronary risk factors. METHODS: Fifty patients with normal coronary angiograms were studied. The MBF responses to CPT was determined by means of positron emission tomography before and after intravenous infusion of 3 g vitamin C or saline (placebo), as well as after 3 months and 2 years of 2 g vitamin C or placebo supplementation daily. RESULTS: In hypertensive patients, the change in MBF (DeltaMBF) was not modified significantly by short-term vitamin C administration challenges (0.20 +/- 0.20 ml/g/min; p = NS) but was significantly increased after three months and two years of treatment with vitamin C versus baseline (0.58 +/- 0.27 and 0.63 +/- 0.17 vs. 0.14 +/- 0.18 ml/g/min; both p < or = 0.001). In smokers, DeltaMBF in response to CPT was significantly increased after short-term vitamin C infusion and long-term vitamin C treatment (0.52 +/- 0.10, 0.54 +/- 0.13, 0.50 +/- 0.07 vs. -0.08 +/- 0.10 ml/g/min; all p < or = 0.001). In hypercholesterolemic patients, no improvement in DeltaMBF during CPT was observed after short- and long-term vitamin C treatment (0.05 +/- 0.14, 0.08 +/- 0.18, 0.02 +/- 0.19 vs. 0.08 +/- 0.16 ml/g/min; p = NS). The CPT-induced DeltaMBF in hypertensive patients and smokers after follow-up was significant as compared with placebo and control subjects (p < or = 0.001). CONCLUSIONS: The present study revealed marked heterogeneous responses in MBF changes to short- and long-term vitamin C treatment in patients with various risk factors, which highlights the quite complex nature underlying abnormal coronary vasomotion.

Antioxidants↗

Non-invasive differentiation of pancreatic lesions: is analysis of FDG kinetics superior to semiquantitative uptake value analysis?

The diagnostic utility of fluorine-18 2-deoxy-D-glucose positron emission tomography (FDG PET) for the non-invasive differentiation of focal pancreatic lesions originating from cancer or chronic pancreatitis by combined visual image interpretation and semiquantitative uptake value analysis has been documented. However, in clinical routine some misdiagnosis is still observed. This is because there is potential overlap between the semiquantitative uptake values obtained for active inflammatory lesions and cancer. Therefore, this prospective study was undertaken to test the hypothesis that analysis of dynamic kinetics of focal pancreatic lesions based on FDG PET may more accurately determine the benign or malignant nature of such lesions. Thirty patients (56+/-17 years) were studied dynamically with FDG PET for a period of 60-90 min. Patients were assigned to one of four groups: control, acute pancreatitis, chronic pancreatitis or pancreatic cancer. Two observers, blinded to the clinical data, analysed the time-activity curves of FDG kinetics based on region of interest analysis. The diagnosis predicted by FDG PET was compared with the result of histological examination of the surgical specimen. Analysis of FDG kinetics revealed significant differences in the shape of the time-activity curve for controls, pancreatic cancer and inflammatory disease. Surprisingly, there was no significant difference in the time-activity curve shape for chronic pancreatitis and acute pancreatitis; this is, however, not a clinical issue. Furthermore, acquisition time (60 min vs 90 min) did not affect interpretation of the time-activity curve, so that scanning time may be regularly shortened to 60 min. Interobserver agreement was 1. Based on these findings, non-invasive differentiation between pancreatic cancer and chronic pancreatitis was correctly predicted in all cases, as confirmed by histology. In addition, the specificity was increased compared with that obtained from standardised uptake value analysis. Non-invasive differentiation between pancreatic cancer and chronic pancreatitis may best be achieved based on a dynamic FDG PET study including kinetic analysis. This approach yields results superior to those obtained from a semiquantitative analysis of pancreatic lesions.

Acute Disease↗

3D-Cardiac-PET. A Recommendable Clinical Alternative to 2D-Cardiac-PET?

The objective of this study was to test the clinical practicability of a 3D-cardiac-positron emission tomography(PET) procedure. During preoperative viability diagnostics of the myocardium with fluorine-18-fluorodeoxyglucose(18F-FDG)PET, comparative recordings were made in 2D (ECAT Exact) and 3D Mode (Quest). Ten patients (2 women, 8 men, ages 34-72 years) with coronary artery disease and a known myocardial infarction in the history were examined. Both examinations were made on the same day following single FDG injection. In 9 of the 10 cases, 3 independent examiners arrived at the same diagnoses from the 2D and 3D recordings, whereby only one-third the activity used for 2D exposures was required for 3D acquisition. In one case, the 3D recording showed no accumulation around the anterior wall near the apex, in spite of demonstrated, albeit limited, viability in the 2D mode. The cause of this discrepant finding is assumed to lie in equipment/uptake and patient-related differences in the test configuration. In summary, 3D acquisition offers a promising alternative to 2D recordings in the viability diagnostics of the myocardium based on a considerable reduction in radiation exposure for patients and personnel, as well as reduction in the costs for radiopharmaceuticals. Further evaluation of the method in broader studies would appear necessary.

Journal Article↗

Myocardial viability in patients with ischemic cardiomyopathy-evaluation by 3-D integration of myocardial scintigraphic data--and coronary angiographic data.

PURPOSE: To determine the prevalence of viable myocardium in patients with ischemic cardiomyopathy and, to evaluate the value of three-dimensional (3-D) fusion imaging of myocardial scintigraphic and angiographic data to assign coronary artery lesions to the corresponding viable and nonviable myocardial territory. PROCEDURES: In 105 patients, the combination of perfusion and metabolic imaging with (201)thallium ((201)TI) single-photon emission computed tomography (SPECT) and 2-deoxy-2-[(18)F]fluoro-D-glucose (FDG) positron emission tomography (PET) determined viability in dysfunctional myocardium. In addition, the value of 3-D scintigraphic fusion imaging was assessed in these patients. RESULTS: Based on the presence of viable dysfunctional myocardium, 54% of patients with ischemic cardiomyopathy may be considered for coronary revascularization. In 31 of 105 patients, the 3-D fusion imaging was estimated to be helpful in the diagnostic and interpretative process. CONCLUSION: In patients with end-stage coronary artery disease scintigraphic imaging is most important in the decision-making process. Three-dimensional fusion imaging may add important information in approximately 30% of these patients.

Aged↗