PubMed Health⌕ Search

Biomedical subjects

Michael Mutter

Publications and source records attributed to Michael Mutter.

4 recordsLinked to original sources

One hospital's journey toward reducing medication errors.

BACKGROUND: The Valley Hospital, a 451-bed acute care facility in Ridgewood, New Jersey, has made substantial progress in the reduction of medication administration errors. METHODS: Reduction in medication administration errors were accomplished through (1) becoming intimately familiar with the errors, including where, when, why, and how they were occurring; (2) establishing a nonpunitive environment and encouraging reporting of errors, including near-miss errors; (3) trending error report data to identify areas of concentrated errors in the medication use process; (4) simplifying and standardizing process steps; and (5) selecting the right technology to address error-prone steps in the hospital's systems. RESULTS: The establishment of a nonpunitive environment led to a dramatic increase in the number of nearmiss errors reported, and the information gained proved to be valuable and diagnostic. Establishing an interview process with the caregivers directly involved in occurrences enabled us to gather detailed information about errors. This forum led the way to an early understanding of human factors, system failures, and root cause analysis. Those errors were trended, addressed, and reduced through manual system changes and technological system developments designed to ensure the "five rights" of safe medication administration. CONCLUSIONS: Keeping on course requires constant and continuous review of medication use processes to ensure that they support instead of unnecessarily limit actual practices.

Hospital Bed Capacity, 300 to 499↗

Impact of prenatal diagnosis on the prevalence of live births with Down syndrome in the eastern half of Switzerland 1980-1996.

OBJECTIVES AND METHODS: To investigate the impact of prenatal diagnosis on trisomy 21 live births, we collected all prenatal and postnatal trisomy 21 cases (n = 1096) in the eastern half of Switzerland for the years 1980-1996. RESULTS: Despite increasing prenatal detection rates of trisomy 21 foetuses (an increase of 169% in the last 5 versus the first 5 years of the study period) and subsequent termination of pregnancies, the number of liveborn Down syndrome children remained constant. The reason is a shift towards a higher mean maternal age from 28 to 30 years between 1980 and 1996. If mean maternal age at delivery was considered, the observed increase of trisomy 21 conceptions matched well with the calculated figures. CONCLUSION: If the tendency to have pregnancies at a more advanced age continues and if the use of prenatal diagnosis does not increase, an increase in incidence of Down syndrome liveborns may be expected in the first decades of the 21st century.

Abortion, Induced↗

Life after phlebotomy deployment: reducing major patient and specimen identification errors.

In addition to establishing a non-punitive environment for reporting errors, and analyzing the root causes of errors, The Valley Hospital volunteered to be a beta test site for a barcode specimen management technology. As a result of implementing this positive patient and specimen identification system, the hospital has reduced its patient and specimen misidentification errors by 77 percent in the last year.

Blood Specimen Collection↗