PubMed Health⌕ Search

Biomedical subjects

Michael R Bailey

Publications and source records attributed to Michael R Bailey.

15 recordsLinked to original sources

Use of a bovine eye lens for observation of HIFU-induced lesions in real-time.

Study of coagulative lesion formation by high intensity focused ultrasound (HIFU) in tissue usually requires performing a sequence of experiments under different exposure conditions followed by tissue sectioning. This paper, inspired by the pioneering work of Frederic L. Lizzi, reports on the use of the bovine eye lens as a laboratory model to observe visually the development of HIFU-induced lesions. The first part of this work describes the measurement of the lens shape, density, sound speed and attenuation. The measured values were within the range of previously published values. In the second part, HIFU-induced lesion development was observed in real-time and compared with good agreement with theoretical simulation. Theoretical modeling included acoustic propagation, absorptive heating and thermal dose, as well as the experimentally measured lens characteristics. Thus, the transparent eye lens can be used as a laboratory phantom to facilitate the understanding of HIFU treatment in other tissues.

Acoustics↗

Effects of nonlinear propagation, cavitation, and boiling in lesion formation by high intensity focused ultrasound in a gel phantom.

The importance of nonlinear acoustic wave propagation and ultrasound-induced cavitation in the acceleration of thermal lesion production by high intensity focused ultrasound was investigated experimentally and theoretically in a transparent protein-containing gel. A numerical model that accounted for nonlinear acoustic propagation was used to simulate experimental conditions. Various exposure regimes with equal total ultrasound energy but variable peak acoustic pressure were studied for single lesions and lesion stripes obtained by moving the transducer. Static overpressure was applied to suppress cavitation. Strong enhancement of lesion production was observed for high amplitude waves and was supported by modeling. Through overpressure experiments it was shown that both nonlinear propagation and cavitation mechanisms participate in accelerating lesion inception and growth. Using B-mode ultrasound, cavitation was observed at normal ambient pressure as weakly enhanced echogenicity in the focal region, but was not detected with overpressure. Formation of tadpole-shaped lesions, shifted toward the transducer, was always observed to be due to boiling. Boiling bubbles were visible in the gel and were evident as strongly echogenic regions in B-mode images. These experiments indicate that nonlinear propagation and cavitation accelerate heating, but no lesion displacement or distortion was observed in the absence of boiling.

Acrylic Resins↗

A step-by-step procedure to aid the assessment of intake and doses from measurement data.

The interpretation of bioassay data to assess intakes and doses depends not only on the biokinetic model used but also on the choice of parameter values made by the assessor. Therefore, it is understandable that different assessors will draw different conclusions from the same datasets even if the same models are used. A systematic step-by-step procedure is proposed for the assessment of cases with comprehensive data in which the time of intake is known. The aims are to promote harmonisation of dose assessments and to assist in obtaining the best available assessment of intake and dose from the monitoring data. The procedure is illustrated by means of an example reported recently in the literature. The case which involves a 6 y follow-up of a subject who inhaled (241)Am, is somewhat unusual in that there are comprehensive in vivo measurements, but few excretion data. The rate at which activity is absorbed from lungs to blood can be one of the largest sources of uncertainty in any inhalation assessment, and significantly improved fits to the measurement data were obtained by choosing appropriate values for the relevant parameters. 'The best estimate' of the resulting effective dose in this case was higher by a factor of approximately 2 or 3, respectively, than those obtained assuming ICRP default values for Type M or Type S.

Administration, Inhalation↗

Ultracal-30 gypsum artificial stones for research on the mechanisms of stone breakage in shock wave lithotripsy.

Artificial stones are used in research on the mechanisms of stone breakage in shock wave lithotripsy (SWL) and in assessing lithotripter performance. We have adopted Ultracal-30 gypsum as a model, finding it suitable for SWL studies in vitro, acute animal experiments in which stones are implanted in the kidney, and as a target to compare the in vitro performance of intracorporeal lithotripters. Here we describe the preparation of U-30 stones, their material properties, shock wave (SW) breakage characteristics, and methods used for quantitation of stone fragmentation with this model. Ultracal-30 gypsum cement was mixed 1:1 with water, cast in plastic multi-well plates, then, the stones were liberated by dissolving the plastic with chloroform and stored under water. Stone breakage in SWL was assessed by several methods including measures of the increase in projected surface area of SW-treated stones. Breakage of hydrated stones showed a linear increase in fragment area with increased SW-number and SW-voltage. Stones stored in water for an extended time showed reduced fragility. Dried stones could be rehydrated so that breakage was not different from stones that had never been dry, but stones rehydrated for less than 96 h showed increased fragility to SWs. The physical properties of U-30 stones place them in the range reported for natural stones. U-30 stones in vitro and in vivo showed equivalent response to SW-rate, with approximately 200% greater fragmentation at 30 SW/min compared to 120 SW/min, suggesting that the mechanisms of SW action are similar under both conditions. U-30 stones provide a convenient, reproducible model for SWL research.

Calcium Sulfate↗

Cavitation detection during shock-wave lithotripsy.

A system was built to detect cavitation in pig kidney during shock-wave lithotripsy (SWL) with a Dornier HM3 lithotripter. Active detection using echo on B-mode ultrasound, and passive cavitation detection using coincident signals on confocal orthogonal receivers, were used to interrogate the renal collecting system (urine) and the kidney parenchyma (tissue). Cavitation was detected in urine immediately upon shock-wave (SW) administration in urine or urine plus X-ray contrast agent but, in native tissue, cavitation required hundreds of SWs to initiate. Localization of cavitation was confirmed by fluoroscopy, sonography and by thermally marking the kidney using the passive cavitation detection receivers as high-intensity focused ultrasound sources. Cavitation collapse times in tissue and native urine were about the same, but less than in urine after injection of X-ray contrast agent. The finding that cavitation occurs in kidney tissue is a critical step toward determining the mechanisms of tissue injury in SWL.

Animals↗

A suppressor to prevent direct wave-induced cavitation in shock wave therapy devices.

Cavitation plays a varied but important role in lithotripsy. Cavitation facilitates stone comminution, but can also form an acoustic barrier that may shield stones from subsequent shock waves. In addition, cavitation damages tissue. Spark-gap lithotripters generate cavitation with both a direct and a focused wave. The direct wave propagates as a spherically diverging wave, arriving at the focus ahead of the focused shock wave. It can be modeled with the same waveform (but lower amplitude) as the focused wave. We show with both simulations and experiments that bubbles are forced to grow in response to the direct wave, and that these bubbles can still be large when the focused shock wave arrives. A baffle or "suppressor" that blocks the propagation of the direct wave is shown to significantly reduce the direct wave pressure amplitude, as well as direct wave-induced bubble growth. These results are applicable to spark-gap lithotripters and extracorporeal shock wave therapy devices, where cavitation from the direct wave may interfere with treatment. A simple direct-wave suppressor might therefore be used to improve the therapeutic efficacy of these devices.

Acoustics↗

The relation between cavitation and platelet aggregation during exposure to high-intensity focused ultrasound.

Our previous study showed that high-intensity focused ultrasound (HIFU) is capable of producing "primary acoustic hemostasis" in the form of ultrasound (US)-induced platelet activation, aggregation and adhesion to a collagen-coated surface. In the current study, 1.1 MHz continuous-wave HIFU was used to investigate the role of cavitation as a mechanism for platelet aggregation in samples of platelet-rich plasma. A 5 MHz passive cavitation detector was used to monitor cavitation activity and laser aggregometry was used to measure platelet aggregation. Using spatial average intensities from 0 to 3350 W/cm2, the effects of HIFU-induced cavitation on platelet aggregation were investigated by enhancing cavitation activity through use of US contrast agents and by limiting cavitation activity through use of an overpressure system. Our results show that increased cavitation activity lowers the intensity threshold to produce platelet aggregation and decreased cavitation activity in the overpressure system raises the intensity threshold for platelet aggregation.

Albumins↗

Dual-pulse lithotripter accelerates stone fragmentation and reduces cell lysis in vitro.

Lithotripsy is a common effective treatment for kidney stones. However, focal volumes are often larger than stones, and surrounding tissue is often injured. Our goal was to test in vitro a new lithotripter consisting of two opposing, confocal and simultaneously triggered electrohydraulic sources. The pulses superimpose at the common focus, resulting in pressure doubling and enhanced cavitation growth in a localized, approximately 1-cm wide volume. Model gypsum stones and human erythrocytes were exposed to dual pulses or single pulses. At the focus, model stones treated with 100 dual pulses at a charging voltage of 15 kV broke into 8 times the number of fragments as stones treated with 200 single pulses at 18 kV. At axial positions 2 and 4 cm away from the focus, lysis of erythrocytes was reduced or equivalent for dual pulses vs. single pulses. Hence, in half the time, dual pulses increased comminution at the focus without increasing injury in surrounding regions.

Erythrocytes↗

Cavitation bubble cluster activity in the breakage of kidney stones by lithotripter shockwaves.

BACKGROUND AND PURPOSE: There is strong evidence that cavitation bubble activity contributes to stone breakage and that shockwave-bubble interactions are involved in the tissue trauma associated with shockwave lithotripsy. Cavitation control may thus be a way to improve lithotripsy. MATERIALS AND METHODS: High-speed photography was used to analyze cavitation bubble activity at the surface of artificial and natural kidney stones during exposure to lithotripter shockwaves in vitro. RESULTS: Numerous individual bubbles formed on the surfaces of stones, but these bubbles did not remain independent but rather combined to form clusters. Bubble clusters formed at the proximal and distal ends and at the sides of stones. Each cluster collapsed to a narrow point of impact. Collapse of the proximal cluster eroded the leading face of the stone, and the collapse of clusters at the sides of stones appeared to contribute to the growth of cracks. Collapse of the distal cluster caused minimal damage. CONCLUSION: Cavitation-mediated damage to stones is attributable, not to the action of solitary bubbles, but to the growth and collapse of bubble clusters.

Calcium Sulfate↗

Kidney damage and renal functional changes are minimized by waveform control that suppresses cavitation in shock wave lithotripsy.

PURPOSE: In studies to understand better the role of cavitation in kidney trauma associated with shock wave lithotripsy we assessed structural and functional markers of kidney injury when animals were exposed to modified shock waves (pressure release reflector shock pulses) that suppress cavitation. Experiments were also performed in isolated red blood cells, an in vitro test system that is a sensitive indicator of cavitation mediated shock wave damage. MATERIALS AND METHODS: We treated 6-week-old anesthetized pigs with shock wave lithotripsy using an unmodified HM3 lithotriptor (Dornier Medical Systems, Marietta, Georgia) fitted with its standard brass ellipsoidal reflector (rigid reflector) or with a pressure release reflector insert. The pressure release reflector transposes the compressive and tensile phases of the lithotriptor shock pulse without otherwise altering the positive pressure or negative pressure components of the shock wave. Thus, with the pressure release reflector the amplitude of the incident shock wave is not changed but cavitation in the acoustic field is stifled. The lower pole of the right kidney was treated with 2,000 shocks at 24 kV. Glomerular filtration rate, renal plasma flow and tubular extraction of para-aminohippurate were measured in the 2 kidneys 1 hour before and 1 and 4 hours after shock wave lithotripsy, followed by the removal of each kidney for morphological analysis. In vitro studies assessed shock wave induced lysis to red blood cells in response to rigid or pressure release reflector shock pulses. RESULTS: Sham shock wave lithotripsy had no significant effect on kidney morphology, renal hemodynamics or para-aminohippurate extraction. Shock waves administered with the standard rigid reflector induced a characteristic morphological lesion and functional changes that included bilateral reduction in renal plasma flow, and unilateral reduction in the glomerular filtration rate and para-aminohippurate extraction. When the pressure release reflector was used, the morphological lesion was limited to hemorrhage of vasa recta vessels near the tips of renal papillae and the only change in kidney function was a decrease in the glomerular filtration rate at the 1 and 4-hour periods in shock wave treated kidneys. Red blood cell lysis in vitro was significantly lower with the pressure release reflector than with the rigid reflector. CONCLUSIONS: These data demonstrate that shock wave lithotripsy damage to the kidney is reduced when cavitation is suppressed. This finding supports the idea that cavitation has a prominent role in shock wave lithotripsy trauma.

Animals↗

In vitro sonoluminescence and sonochemistry studies with an electrohydraulic shock-wave lithotripter.

Sonoluminescence and sonochemistry from a cavitation field generated by an electrohydraulic shock-wave lithotripter were investigated as functions of spark discharge voltage (13 to 21 kV) and pulse-repetition frequency (PRF) (0.5 to 2.0 Hz). Sonochemical activity, measured with an iodide dosimeter, increased with both voltage and PRF. Sonoluminescence was measured in an acoustically matched light-tight box. The envelope of the light intensity was measured in a temporally gated region extending from the initial arrival of the shock wave (resulting in bubble compression) to the final inertial collapse of the bubble cloud, which follows hundreds of micros after passage of the shock wave. The initial compression resulted in greater sonoluminescence emissions, suggesting that the initial bubble compression due to the leading positive pressure spike from the lithotripter generated higher temperatures than the inertial collapse of the bubble. These unexpected results are consistent with some recent calculations in which the vapor pressure of the liquid limits compressional heating.

Acoustics↗

Prefocal alignment improves stone comminution in shockwave lithotripsy.

BACKGROUND: The Dornier HM-3 machine continues to be one of the most effective lithotripters in use. However, tissue damage occurs in most, if not all, shockwave lithotripsy (SWL) treatments. Cavitation appears to contribute to desired stone comminution as well as to undesired tissue damage. Studies of cavitation in electrohydraulic shockwave lithotripters indicate that the greatest cavitation activity occurs, not at the geometric focus, F2, but at a site proximal to F2 by 1 to 3 cm. In clinical practice, however, stones are aligned with F2. MATERIALS AND METHODS: In vitro stone comminution, hemolysis, and free-radical production were assessed along the focal axis, and pig kidneys treated with SWL in vivo were sectioned to determine the extent of hemorrhagic injury along the focal axis. Model gypsum stones received 200 shockwaves in vitro at 18 kV. RESULTS: At F2, the average number of fragments >1.5 mm was 1.3 +/- 0.5, and the weight loss was 11.3 +/- 1.1%. At 2 cm from F2 (F2-2 cm), these values increased to 4 +/- 2.8 and 16.1 +/- 4.2%, respectively. Samples of 10% hematocrit blood were similarly exposed. Hemolysis was equivalent at F2-2 cm (14.7 +/- 2.3%) and F2 (15.2 +/- 3%) but decreased significantly at all other positions. Samples of iodine solution received 1500 shockwaves at 20 kV. Hydroxyl radical production was greatest at F2-2 cm (0.384 +/- 0.035 microM) and decreased significantly distal to this position. The volume of tissue injury in pig kidneys was greatest with prefocal shockwave exposure. CONCLUSION: Stone comminution may be achieved more rapidly without greater tissue damage by a simple shift in stone alignment to F2-2 cm.

Animals↗

Effect of overpressure and pulse repetition frequency on cavitation in shock wave lithotripsy.

Cavitation appears to contribute to tissue injury in lithotripsy. Reports have shown that increasing pulse repetition frequency [(PRF) 0.5-100 Hz] increases tissue damage and increasing static pressure (1-3 bar) reduces cell damage without decreasing stone comminution. Our hypothesis is that overpressure or slow PRF causes unstabilized bubbles produced by one shock pulse to dissolve before they nucleate cavitation by subsequent shock pulses. The effects of PRF and overpressure on bubble dynamics and lifetimes were studied experimentally with passive cavitation detection, high-speed photography, and B-mode ultrasound and theoretically. Overpressure significantly reduced calculated (100-2 s) and measured (55-0.5 s) bubble lifetimes. At 1.5 bar static pressure, a dense bubble cluster was measured with clinically high PRF (2-3 Hz) and a sparse cluster with clinically low PRF (0.5-1 Hz), indicating bubble lifetimes of 0.5-1 s, consistent with calculations. In contrast to cavitation in water, high-speed photography showed that overpressure did not suppress cavitation of bubbles stabilized on a cracked surface. These results suggest that a judicious use of overpressure and PRF in lithotripsy could reduce cavitation damage of tissue while maintaining cavitation comminution of stones.

Equipment Design↗