Michael R Descour

Publications and source records attributed to Michael R Descour.

8 recordsLinked to original sources

Design, assembly, and optical bench testing of a high-numerical-aperture miniature injection-molded objective for fiber-optic confocal reflectance microscopy.

The design, analysis, assembly methods, and optical-bench test results for a miniature injection-molded plastic objective lens used in a fiber-optic confocal reflectance microscope are presented. The five-lens plastic objective was tested as a stand-alone optical system before its integration into a confocal microscope for in vivo imaging of cells and tissue. Changing the spacing and rotation of the individual optical elements can compensate for fabrication inaccuracies and improve performance. The system performance of the miniature objective lens is measured by use of an industry-accepted slanted-edge modulation transfer function (MTF) metric. An estimated Strehl ratio of 0.61 and a MTF value of 0.66 at the fiber-optic bundle Nyquist frequency have been obtained. The optical bench testing system is configured to permit interactive optical alignment during testing to optimize performance. These results are part of an effort to demonstrate the manufacturability of low-cost, high-performance biomedical optics for high-resolution in vivo imaging. Disposable endoscopic microscope objectives could help in vivo confocal microscopy technology mature to permit wide-scale clinical screening and detection of early cancers and precancerous lesions.

Computer-Aided Design↗

Removal of ghost images by using tilted element optical systems with polynomial surfaces for aberration compensation.

A novel solution to problematic ghost images is implemented by using tilted lens elements with polynomial surfaces. Tilting the lens surfaces sends reflections out of the imaging path. The nonrotationally symmetric polynomial surfaces correct aberrations caused by tilts. The complex lens surfaces are fabricated by using gray-scale lithographic patterning of hybrid solgel glass.

Artifacts↗

Eye-movement study and human performance using telepathology virtual slides: implications for medical education and differences with experience.

A core skill in diagnostic pathology is light microscopy. Remarkably little is known about human factors that affect the proficiency of pathologists as light microscopists. The cognitive skills of pathologists have received relatively little attention in comparison with the large literature on human performance studies in radiology. One reason for this lack of formal visual search studies in pathology has been the physical restrictions imposed by the close positioning of a microscope operator's head to the microscope's eyepieces. This blocks access to the operator's eyes and precludes assessment of the microscopist's eye movements. Virtual slide microscopy now removes this barrier and opens the door for studies on human factors and visual search strategies in light microscopy. The aim of this study was to assess eye movements of medical students, pathology residents, and practicing pathologists examining virtual slides on a digital display monitor. Whole histopathology glass slide digital images, so-called virtual slides, of 20 consecutive breast core biopsy cases were used in a retrospective study. These high-quality virtual slides were produced with an array-microscope equipped DMetrix DX-40 ultrarapid virtual slide processor (DMetrix, Tucson, Ariz). Using an eye-tracking device, we demonstrated for the first time that when a virtual slide reader initially looks at a virtual slide his or her eyes are very quickly attracted to regions of interest (ROIs) within the slide and that these ROIs are likely to contain diagnostic information. In a matter of seconds, critical decisions are made on the selection of ROIs for further examination at higher magnification. We recorded: (1) the time virtual slide readers spent fixating on self-selected locations on the video monitor; (2) the characteristics of the ways the eyes jumped between fixation locations; and (3) x and y coordinates for each virtual slide marking the sites the virtual slide readers manually selected for zooming to higher ROI magnifications. We correlated the locations of the visually selected fixation locations and the manually selected ROIs. Viewing profiles were identified for each group. Fully trained pathologists spent significantly less time (mean, 4.471 seconds) scanning virtual slides when compared to pathology residents (mean, 7.148 seconds) or medical students (mean, 11.861 seconds), but had relatively prolonged saccadic eye movements (P < .0001). Saccadic eye movements are defined as eye movements between fixation locations. On the other hand, the pathologists spent significantly more time than trainees dwelling on the 3 locations they subsequently chose for zooming. Unlike either the medical students or the residents, the pathologists frequently choose areas for viewing at higher magnification outside of areas of foveal (central) vision. Eye movement studies of scanning pathways (scan paths) may be useful for developing eye movement profiles for individuals and for understanding the difference in performances between novices and experts. They may also be useful for developing new visual search strategies for rendering diagnoses on telepathology virtual slides.

Biopsy↗

Sorting method to extend the dynamic range of the Shack-Hartmann wave-front sensor.

We propose a simple and powerful algorithm to extend the dynamic range of a Shack-Hartmann wave-front sensor. In a conventional Shack-Hartmann wave-front sensor the dynamic range is limited by the f-number of a lenslet, because the focal spot is required to remain in the area confined by the single lenslet. The sorting method proposed here eliminates such a limitation and extends the dynamic range by tagging each spot in a special sequence. Since the sorting method is a simple algorithm that does not change the measurement configuration, there is no requirement for extra hardware, multiple measurements, or complicated algorithms. We not only present the theory and a calculation example of the sorting method but also actually implement measurement of a highly aberrated wave front from nonrotational symmetric optics.

Algorithms↗

An array microscope for ultrarapid virtual slide processing and telepathology. Design, fabrication, and validation study.

This paper describes the design and fabrication of a novel array microscope for the first ultrarapid virtual slide processor (DMetrix DX-40 digital slide scanner). The array microscope optics consists of a stack of three 80-element 10 x 8-lenslet arrays, constituting a "lenslet array ensemble." The lenslet array ensemble is positioned over a glass slide. Uniquely shaped lenses in each of the lenslet arrays, arranged perpendicular to the glass slide constitute a single "miniaturized microscope." A high-pixel-density image sensor is attached to the top of the lenslet array ensemble. In operation, the lenslet array ensemble is transported by a motorized mechanism relative to the long axis of a glass slide. Each of the 80 miniaturized microscopes has a lateral field of view of 250 microns. The microscopes of each row of the array are offset from the microscopes in other rows. Scanning a glass slide with the array microscope produces seamless two-dimensional image data of the entire slide, that is, a virtual slide. The optical system has a numerical aperture of N.A.= 0.65, scans slides at a rate of 3 mm per second, and accrues up to 3,000 images per second from each of the 80 miniaturized microscopes. In the ultrarapid virtual slide processing cycle, the time for image acquisition takes 58 seconds for a 2.25 cm2 tissue section. An automatic slide loader enables the scanner to process up to 40 slides per hour without operator intervention. Slide scanning and image processing are done concurrently so that post-scan processing is eliminated. A virtual slide can be viewed over the Internet immediately after the scanning is complete. A validation study compared the diagnostic accuracy of pathologist case readers using array microscopy (with images viewed as virtual slides) and conventional light microscopy. Four senior pathologists diagnosed 30 breast surgical pathology cases each using both imaging modes, but on separate occasions. Of 120 case reads by array microscopy, there were 3 incorrect diagnoses, all of which were made on difficult cases with equivocal diagnoses by light microscopy. There was a strong correlation between array microscopy vs. "truth" diagnoses based on surgical pathology reports. The kappa statistic for the array microscopy vs. truth was 0.96, which is highly significant (z=10.33, p <0.001). There was no statistically significant difference between rates of agreement with truth between array microscopy and light microscopy (z=0.134, p >0.05). Array microscopy and light microscopy did not differ significantly with respect to the number/percent of correct decisions rendered (t=0.552, p=0.6376) or equivocal decisions rendered (t=2.449, p=0.0917). Pathologists rated 95.8% of array microscopy virtual slide images as good or excellent. None were rated as poor. The mean viewing time for a DMetrix virtual slide was 1.16 minutes. The DMetrix virtual slide processor has been found to reduce the virtual slide processing cycle more than 10 fold, as compared with other virtual slide systems reported to date. The virtual slide images are of high quality and suitable for diagnostic pathology, second opinions, expert opinions, clinical trials, education, and research.

Equipment Design↗

Phase grating design for a dual-band snapshot imaging spectrometer.

Infrared spectral features have proved useful in the identification of threat objects. Dual-band focal-plane arrays (FPAs) have been developed in which each pixel consists of superimposed midwave and long-wave photodetectors [Dyer and Tidrow, Conference on Infrared Detectors and Focal Plane Arrays (SPIE, Bellingham, Wash., 1999), pp. 434-440]. Combining dual-band FPAs with imaging spectrometers capable of interband hyperspectral resolution greatly improves spatial target discrimination. The computed-tomography imaging spectrometer (CTIS) [Descour and Dereniak, Appl. Opt. 34, 4817-4826 (1995)] has proved effective in producing hyperspectral images in a single spectral region. Coupling the CTIS with a dual-band detector can produce two hyperspectral data cubes simultaneously. We describe the design of two-dimensional, surface-relief, computer-generated hologram dispersers that permit image information in these two bands simultaneously.

Journal Article↗

Design of a high-numerical-aperture miniature microscope objective for an endoscopic fiber confocal reflectance microscope.

An endoscopic confocal microscope requires a high-performance, miniaturized microscope objective. We present the design of a miniature water-immersion microscope objective that is approximately 10 times smaller in length than a typical commercial objective. The miniature objective is 7 mm in outer diameter and 21 mm in length (from object to image). It is used in a fiber confocal reflectance microscope. The miniature microscope objective has a numerical aperture of 1.0, a field of view of 250 microm, and a working distance of 450 microm. It delivers diffraction-limited performance at lambda = 1064 nm. Micrometer-level resolution has been experimentally demonstrated.

Endoscopes↗

Direct photolithographic deforming of organomodified siloxane films for micro-optics fabrication.

Direct photolithographic deforming of hybrid glass films is used to fabricate optical structures. The structure is fabricated in polyethylene-oxide-acrylate modified hybrid glass films with (1) binary and gray-scale photomasks using a mercury UV-lamp exposure and (2) maskless UV-laser patterning. Fabrication of isolated lenslets, lens arrays, and gratings is presented, including the associated exposure patterns. The hybrid glass material yields light-induced deformation peak-to-valley (p.v.) heights up to 12.8 microm with mercury UV-lamp exposure and p.v. deformation heights up to 6.8 microm with 365-nm UV-laser exposure. The fabricated lenslets' surface data are presented as Zernike-polynomial fit coefficients. Material synthesis and processing-related aspects are examined to understand and control the material's deformation under exposure. The hybrid glass material exhibits a maximum spectral extinction coefficient of 1.6 x 10(-3) microm(-1) at wavelengths ranging from 450 to 2,200 nm and has a refractive index of 1.52 at 632.8 nm. The fabricated structures exhibit rms surface roughness between 1 and 5 nm.

Journal Article↗