PubMed Health⌕ Search

Biomedical subjects

Michael R Gold

Publications and source records attributed to Michael R Gold.

At least 19 recordsLinked to original sources

Activation of the Rap GTPases in B lymphocytes modulates B cell antigen receptor-induced activation of Akt but has no effect on MAPK activation.

Signaling by the B cell antigen receptor (BCR) activates the Rap1 and Rap2 GTPases, putative antagonists of Ras-mediated signaling. Because Ras can activate the Raf-1/ERK pathway and the phosphatidylinositol 3-kinase (PI3K)/Akt pathway, we asked whether Rap activation limits the ability of the BCR to signal via these pathways. To do this, we blocked the activation of endogenous Rap1 and Rap2 by expressing the Rap-specific GTPase-activating protein RapGAPII. Preventing Rap activation had no effect on BCR-induced activation of ERK. In contrast, BCR-induced phosphorylation of Akt on critical activating sites was increased 2- to 3-fold when Rap activation was blocked. Preventing Rap activation also increased the ability of the BCR to stimulate Akt-dependent phosphorylation of the FKHR transcription factor on negative regulatory sites and decreased the levels of p27Kip1, a pro-apoptotic factor whose transcription is enhanced by FKHR. Moreover, preventing Rap activation reduced BCR-induced cell death in the WEHI-231 B cell line. Thus activation of endogenous Rap by the BCR limits BCR-induced activation of the PI3K/Akt pathway, opposes the subsequent inhibition of the FKHR/p27Kip1 pro-apoptotic module, and enhances BCR-induced cell death. Consistent with the idea that Rap-GTP is a negative regulator of the PI3K/Akt pathway, expressing constitutively active Rap2 (Rap2V12) reduced BCR-induced phosphorylation of Akt and FKHR. Finally, our finding that Rap2V12 can bind PI3K and inhibit its activity in a manner that depends upon BCR engagement provides a potential mechanism by which Rap-GTP limits activation of the PI3K/Akt pathway, a central regulator of B cell growth and survival.

Animals↗

Effect of an implantable cardioverter defibrillator with atrial detection and shock therapies on patient-perceived, health-related quality of life.

BACKGROUND: This study used a device (DDD implantable cardioverter defibrillator [ICD]) capable of delivering pacing and shock therapies to restore normal sinus rhythm in patients with atrial tachycardias or atrial fibrillation (AF). The purpose of this study was to assess the effect of the device on patient-perceived, health-related quality of life (QOL). METHODS: The DDD ICD was implanted in 267 patients with drug refractory, symptomatic AF from 45 centers across Europe, the United States, and Canada. Patients completed self-reported, validated QOL assessments at baseline and at 3- and 6-month follow-up visits (The Medical Outcomes Short Form 36 [SF-36] and the Symptom Checklist [SCL]). RESULTS: The mean age of the study group was 62 +/- 12 years, and 73% of the patients were male. A total of 150 patients completed SF-36 assessments, and 138 patients completed SCL assessments at all 3 times. Baseline scores were more impaired (P <.05) on most SF-36 scales compared with norms for a general population, but were similar to a comparison group of patients with AF who were referred to tertiary care centers. The role-physical, physical functioning, vitality, mental health, and social functioning scales all improved significantly with time (all P <.04). Similarly, symptom frequency and severity (SCL) also improved significantly from baseline to 6 months (both P <.01). Shock therapy was delivered in 86 of the 150 patients (57%) with complete SF-36 evaluations. There was no evidence that receiving shocks decreased the relative improvement in QOL associated with implantation of the device. CONCLUSIONS: In a 6-month period, QOL improves after implantation of a DDD ICD with atrial shock and pacing therapies. These improvements were not attenuated by receipt of shocks.

Atrial Fibrillation↗

Safety of a single successful conversion of ventricular fibrillation before the implantation of cardioverter defibrillators.

UNLABELLED: Multiple successful conversions of ventricular fibrillation (VF) at 10 J below the maximum output of implantable cardioverter defibrillator (ICD) have been recommended as a minimum device implantation criterion. This recommendation is based on the probabilistic properties of defibrillation that necessitates multiple shocks to establish an adequate safety margin for the conversion of subsequent spontaneous arrhythmias. We hypothesized that a single successful shock at a 14 J may suffice. METHODS AND RESULTS: The Low Energy Safety Study (LESS) enrolled 720 patients undergoing initial ICD implantation with a dual-coil transvenous lead and active pulse generator. At implant, an enhanced defibrillation threshold (DFT++) was determined by a rigorous protocol beginning at 14 J, and requiring at least 4 shocks. Fifty percent of all patients were then randomized to full output shock energy and the conversion rates for spontaneous ventricular tachyarrhythmias at rates > 200 beats/min were measured. There were 318 patients randomized to 31 J, of whom 254 were successfully defibrillated by an initial 14 J shock. During a mean follow-up of 24 +/- 12 months, 112 spontaneous VF episodes occurred in 31 patients. The combined conversion success of the first and second shock (when needed) did not differ between the subgroup of patients who were successfully defibrillated by an initial 14 J shock, regardless of the results of additional testing, and the whole cohort who underwent more systematic testing (97% vs 97%). All spontaneous episodes of VF were successfully treated during long-term follow-up. CONCLUSIONS: A first successful shock of 14 J may be a sufficient endpoint to allow the implantation of ICDs with the Triad lead configuration, when programming all shocks to 31 J.

Aged↗

Distal right ventricular coil position reduces defibrillation thresholds.

UNLABELLED: Distal RV Coil Position Reduces DFTs. INTRODUCTION: Understanding the factors that affect defibrillation thresholds (DFTs) has important implications both for optimization of defibrillation efficacy and for the design of new transvenous leads. The aim of this prospective study was to test the hypothesis that defibrillation efficacy is improved with the right ventricular (RV) coil in a distal position compared with a more proximal RV coil position. METHODS AND RESULTS: A novel defibrillation lead with three adjacent RV defibrillation coils (distal 0.8 cm, middle 3.7 cm, proximal 0.8 cm) was used for this study to permit comparison of DFTs with the proximal and distal RV coil positions without lead repositioning. In the distal RV configuration, the distal and middle RV coils were connected electrically as the anode for defibrillation. In the proximal RV configuration, the middle and proximal coils were the anode. A superior vena cava (SVC) coil and active can were connected electrically as the cathode (reversed polarity, RV-->Can+SVC). In each patient, the DFT was measured twice using a binary search protocol with the distal RV and proximal RV configurations, with the order of testing randomized. The study cohort consisted of 31 subjects (mean age 65 +/- 12 years, mean left ventricular ejection fraction 30% +/- 16%, 81% male predominance). The mean delivered energy (8.2 +/- 5.3 J vs 11.2 +/- 6.1 J), leading-edge voltage (335 +/- 109 V vs 393 +/- 118 V), and peak current (11.6 +/- 5.2 A vs 14.9 +/- 7.3 A) at DFT all were significantly lower with the distal RV configuration compared to the proximal RV configuration (P < 0.01 for all comparisons). CONCLUSION: DFTs are significantly reduced with the distal RV configuration compared to the proximal RV configuration. Defibrillation leads should be designed with the shortest tip to coil distance that can be achieved without compromising ventricular fibrillation sensing.

Aged↗

T wave alternans for ventricular arrhythmia risk stratification.

Sudden cardiac death remains one of the leading causes of death in western societies. Accordingly, the ability to identify patients at high risk of sudden cardiac death is important so that appropriate treatments can be used efficiently. Recently, T wave alternans (TWA) has emerged as a promising new test for such risk stratification. TWA is a heart rate-dependent measure of arrhythmia vulnerability, with maximal predictive accuracy at sustained, regular heart rates of 100 to 120 bpm. In the clinical setting, these conditions may be achieved by either exercise or atrial pacing. TWA has been shown to predict inducibility of ventricular tachycardia with programmed stimulation and also spontaneous arrhythmic events. TWA has been successfully applied to diverse populations, including patients with coronary artery disease, nonischemic cardiomyopathy, congestive heart failure, and implantable defibrillators. Despite these encouraging results, the role of TWA to guide clinical therapy still needs to be elucidated better.

Anti-Arrhythmia Agents↗

Relation of ejection fraction and inducible ventricular tachycardia to mode of death in patients with coronary artery disease: an analysis of patients enrolled in the multicenter unsustained tachycardia trial.

BACKGROUND: Fifty percent of deaths in patients with coronary disease occur suddenly. Although many factors correlate with increased mortality, there is little information regarding the influence of these factors on mode of death. As such, optimum methods to determine patients most likely to benefit from implantable defibrillator therapy are unclear. METHODS AND RESULTS: We analyzed the relation of ejection fraction and inducible ventricular tachyarrhythmias to mode of death in all 1791 patients enrolled in the Multicenter Unsustained Tachycardia Trial who did not receive antiarrhythmic therapy. Total mortality and arrhythmic deaths/cardiac arrests occurred more frequently in patients with ejection fraction <30% than in those with ejection fraction of 30% to 40%. The percentage of deaths classified as arrhythmic was similar in patients with ejection fraction <30% or > or =30%. The relative contribution of arrhythmic events to total mortality was significantly higher in patients with inducible tachyarrhythmia (58% of deaths in inducible patients versus 46% in noninducible patients, P=0.004). The higher percentage of events that were arrhythmic among patients with inducible tachyarrhythmia appeared more distinct among patients with an ejection fraction > or =30% (61% of events were arrhythmic among inducible patients with ejection fraction > or =30% and only 42% among noninducible patients, P=0.002). CONCLUSIONS: Both low ejection fraction and inducible tachyarrhythmias identify patients with coronary disease at increased mortality risk. Ejection fraction does not discriminate between modes of death, whereas inducible tachyarrhythmia identifies patients for whom death, if it occurs, is significantly more likely to be arrhythmic, especially if ejection fraction is > or =30%.

Canada↗

The human antimicrobial peptide LL-37 is a multifunctional modulator of innate immune responses.

The role of LL-37, a human cationic antimicrobial peptide, in the immune system is not yet clearly understood. It is a widely expressed peptide that can be up-regulated during an immune response. In this report, we demonstrate that LL-37 is a potent antisepsis agent with the ability to inhibit macrophage stimulation by bacterial components such as LPS, lipoteichoic acid, and noncapped lipoarabinomannan. We also demonstrate that LL-37 protects mice against lethal endotoxemia. In addition to preventing macrophage activation by bacterial components, we hypothesized the LL-37 may also have direct effects on macrophage function. We therefore used gene expression profiling to identify macrophage functions that might be modulated by LL-37. These studies revealed that LL-37 directly up-regulates 29 genes and down-regulated another 20 genes. Among the genes predicted to be up-regulated by LL-37 were those encoding chemokines and chemokine receptors. Consistent with this, LL-37 up-regulated the expression of chemokines in macrophages and the mouse lung (monocyte chemoattractant protein 1), human A549 epithelial cells (IL-8), and whole human blood (monocyte chemoattractant protein 1 and IL-8), without stimulating the proinflammatory cytokine, TNFalpha. LL-37 also up-regulated the chemokine receptors CXCR-4, CCR2, and IL-8RB. These findings indicate that LL-37 may contribute to the immune response by limiting the damage caused by bacterial products and by recruiting immune cells to the site of infection so that they can clear the infection.

Adjuvants, Immunologic↗

The Rap GTPases regulate B cell migration toward the chemokine stromal cell-derived factor-1 (CXCL12): potential role for Rap2 in promoting B cell migration.

Stromal cell-derived factor-1 (SDF-1) is a potent chemoattractant for B cells and B cell progenitors. Although the binding of SDF-1 to its receptor, CXCR4, activates multiple signaling pathways, the mechanism by which SDF-1 regulates cell migration is not completely understood. In this report we show that activation of the Rap GTPases is important for B cells to migrate toward SDF-1. We found that treating B cells with SDF-1 resulted in the rapid activation of both Rap1 and Rap2. Moreover, blocking the activation of Rap1 and Rap2 via the expression of a Rap-specific GTPase-activating protein significantly reduced the ability of B cells to migrate toward SDF-1. Conversely, expressing a constitutively active form of Rap2 increased SDF-1-induced B cell migration. Thus, the Rap GTPases control cellular processes that are important for B cells to migrate toward SDF-1.

Animals↗

The B cell antigen receptor regulates the transcriptional activator beta-catenin via protein kinase C-mediated inhibition of glycogen synthase kinase-3.

Beta-catenin is a transcriptional activator that is regulated by glycogen synthase kinase-3 (GSK-3). GSK-3 is constitutively active in unstimulated cells where it phosphorylates beta-catenin, targeting beta-catenin for rapid degradation. Receptor-induced inhibition of GSK-3 allows beta-catenin to accumulate in the cytoplasm and then translocate to the nucleus where it promotes the transcription of genes such as c-myc and cyclin D1. Wnt hormones, the best known regulators of beta-catenin, inhibit GSK-3 via the Disheveled protein. However, GSK-3 is also inhibited when it is phosphorylated by Akt, a downstream target of phosphatidylinositol 3-kinase (PI3K). We have previously shown that B cell Ag receptor (BCR) signaling leads to activation of PI3K and Akt as well as inhibition of GSK-3. Therefore, we hypothesized that BCR engagement would induce the accumulation of beta-catenin via a PI3K/Akt/GSK-3 pathway. We now show that BCR ligation causes an increase in the level of beta-catenin in the nuclear fraction of B cells as well as an increase in beta-catenin-dependent transcription. Direct inhibition of GSK-3 by LiCl also increased beta-catenin levels in B cells. This suggests that GSK-3 keeps beta-catenin levels low in unstimulated B cells and that BCR-induced inhibition of GSK-3 allows the accumulation of beta-catenin. Surprisingly, we found that the BCR-induced phosphorylation of GSK-3 on its negative regulatory sites, as well as the subsequent up-regulation of beta-catenin, was not mediated by Akt but by the phospholipase C-dependent activation of protein kinase C. Thus, the BCR regulates beta-catenin levels via a phospholipase C/protein kinase C/GSK-3 pathway.

Animals↗

Effect of implantable defibrillators on arrhythmic events and mortality in the multicenter unsustained tachycardia trial.

BACKGROUND: The Multicenter Unsustained Tachycardia Trial (MUSTT) was designed to evaluate an antiarrhythmic treatment strategy, including drugs and implantable defibrillators (ICDs), guided by electrophysiological (EP) testing. We performed several statistical analyses to assess the contribution of defibrillators to the observed treatment benefit. METHODS AND RESULTS: First, the effects of defibrillators were indirectly examined by comparing the randomized treatment arms (EP-guided therapy versus no antiarrhythmic therapy) within subgroups that varied according to ICD usage. Use of ICDs increased during the trial; hence, the randomized treatments were compared according to date of enrollment. There were also site-specific differences in ICD use; hence, the randomized arms were compared within groups of sites defined by level of ICD use. There was a distinct "dose response" in relation to ICD use. Where ICD use was high, EP-guided therapy produced significant reductions in arrhythmic death or cardiac arrest (P<0.004). Where ICD use was low, there was no benefit of EP-guided therapy. Finally, outcomes of EP-guided therapy patients who received an ICD were directly compared with outcomes of other patients using the Cox proportional hazards model with receipt of an ICD as a time-dependent covariate. Adjusted for other prognostic factors, patients who received an ICD had risk reductions of >70% in arrhythmic death or cardiac arrest and >50% in total mortality (P<0.001 for both end points). CONCLUSIONS: The benefit of EP-guided antiarrhythmic therapy observed in MUSTT was due to improved outcomes among patients who received an ICD but not among patients who received antiarrhythmic drugs.

Anti-Arrhythmia Agents↗

Activation and phosphatidylinositol 3-kinase-dependent phosphorylation of protein kinase C-epsilon by the B cell antigen receptor.

Protein kinase C (PKC) enzymes play an important role in B cell antigen receptor (BCR) signaling, linking the BCR to the activation of mitogen-activated protein kinases as well as the NF-kappa B, and AP-1 transcription factors. There are eleven different PKC isoforms, each of which is likely to have a unique set of substrates and hence a unique role in signal transduction. Although PKC-alpha, PKC-beta, PKC-delta, and PKC-zeta have been shown to be targets of BCR signaling, the full spectrum of PKC enzymes that are activated by the BCR remains to be determined. In this report, we show that PKC-epsilon is a target of BCR signaling. We found that PKC-epsilon is highly expressed in B cells and that BCR engagement causes PKC-epsilon to translocate from the cytosol to cellular membranes. This presumably reflects the binding of PKC-epsilon to its membrane-associated lipid activator, diacylglycerol. We also found that BCR engagement resulted in the phosphatidylinositol 3-kinase-dependent phosphorylation of PKC-epsilon. This modification may promote the full activation of PKC-epsilon. Activation of PKC-epsilon could be a key event in BCR signaling since PKC-epsilon has been strongly linked to cell survival and proliferation in other cell types.

Animals↗

Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: primary results from the Low Energy Safety Study (LESS).

BACKGROUND: Traditionally, a safety margin of at least 10 J between the maximum output of the pulse generator and the energy needed for ventricular defibrillation has been used because lower safety margins were associated with unacceptably high rates of failed defibrillation and sudden cardiac death. The Low Energy Safety Study (LESS) was a prospective, randomized assessment of the safety margin requirements for modern implantable cardioverter-defibrillator (ICD) systems. METHODS AND RESULTS: A total of 636 patients undergoing initial ICD implantation with a dual-coil lead and active pulse generator were evaluated. The defibrillation threshold (DFT) and enhanced DFT (DFT+ and DFT++) were measured using a modified step-down protocol. Conversion testing of induced ventricular fibrillation before discharge, at 3 months, and at 12 months was performed, as was randomization to chronic programming at either 2 steps above DFT++ or maximal output. The induced ventricular fibrillation data had conversion success rates of 91.4%, 97.9%, 99.1%, 99.6%, and 99.8% for safety margins of 0, 1, 2, 3, and 4 steps above the DFT++, respectively. A margin of 4 to 6 J was adequate to maintain high conversion success over time (98.9% before discharge versus 99.2% at 12 months; P=NS). Over a mean follow-up of 24+/-13 months, conversion of spontaneously occurring ventricular tachyarrhythmias >200 bpm was identical (97.3%), despite a safety margin difference of 5.2+/-1.1 J for the 2-step group versus 20.8+/-4.2 J for maximal output. CONCLUSIONS: With a rigorous implantation algorithm, a safety margin of about 5 J is adequate for safe implantation of modern ICD systems.

Aged↗

Effects of selective autonomic blockade on T-wave alternans in humans.

BACKGROUND: T-wave alternans (TWA) is an important noninvasive measure of ventricular arrhythmia vulnerability. This study tested the hypothesis that the autonomic nervous system influences TWA measurement in high-risk subjects with coronary artery disease. METHODS AND RESULTS: T-wave alternans was measured in 60 patients with coronary artery disease, left ventricular dysfunction, and inducible sustained ventricular tachycardia during electrophysiological studies. All patients had TWA measured at baseline with atrial pacing at 100 bpm (600 ms), 109 bpm (550 ms), and 120 bpm (500 ms). After a 10-minute recovery period, TWA was measured again after sympathetic blockade (esmolol, n=20), parasympathetic blockade (atropine, n=20), or no intervention (control subjects, n=20). The prevalence of significant TWA was unchanged compared with baseline after atropine infusion and in the control group. In contrast, the amplitude of TWA in the vector magnitude lead was significantly reduced after esmolol infusion (P<0.001), and the number of positive TWA tests was reduced by 50% (70% versus 35%, P<0.05). CONCLUSIONS: Our findings have important implications for the use of TWA to risk-stratify patients for life-threatening ventricular arrhythmias and provide a new potential mechanism for the reduction in sudden cardiac death conferred by beta-blockers among patients with coronary artery disease and congestive heart failure.

Adrenergic beta-Antagonists↗

CD40 signaling in B cells regulates the expression of the Pim-1 kinase via the NF-kappa B pathway.

The ability of CD40 signaling to regulate B cell growth, survival, differentiation, and Ig class switching involves many changes in gene expression. Using cDNA expression arrays and Northern blotting, we found that CD40 signaling increased the mRNA levels for pim-1, a protooncogene that encodes a serine/threonine protein kinase. Subsequent experiments showed that CD40 engagement also increased both Pim-1 protein levels and Pim-1 kinase activity in B cells. We then investigated the signaling pathways by which CD40 regulates Pim-1 expression and found that CD40 up-regulates Pim-1 primarily via the activation of NF-kappaB. Inhibiting the activation of NF-kappaB, either by treating cells with a chemical inhibitor, BAY11-7082, or by inducibly expressing a superrepressor form of IkappaBalpha, significantly impaired the ability of CD40 to increase Pim-1 protein levels. Because Pim-1 expression is associated with cell proliferation and survival, we asked whether this correlated with the ability of CD40 signaling to prevent anti-IgM-induced growth arrest in the WEHI-231 murine B cell line, a model for Ag-induced clonal deletion. We found that the anti-IgM-induced growth arrest in WEHI-231 cells correlated with a substantial decrease in Pim-1 levels. In contrast, culturing WEHI-231 cells with either anti-CD40 Abs or with the B cell mitogen LPS, both of which prevent the anti-IgM-induced growth arrest, also prevented the rapid decline in Pim-1 levels. This suggests that Pim-1 could regulate the survival and proliferation of B cells.

Animals↗