PubMed Health⌕ Search

Biomedical subjects

Michael Stracher

Publications and source records attributed to Michael Stracher.

3 recordsLinked to original sources

Pseudoaneurysm associated with multiple osteochondromatosis.

The authors present a case of a 12-year-old boy with a known family history of multiple hereditary exostoses who presented with knee swelling. Physical examination and subsequent workup revealed a pseudoaneurysm associated with an osteochondroma. We present this interesting case and review the literature.

Aneurysm, False↗

A biomechanical comparison of a dorsal 3.5-mm T-plate and a volar fixed-angle plate in a model of dorsally unstable distal radius fractures.

OBJECTIVES: To compare the biomechanical stability of internal fixation of extra-articular, dorsally unstable distal radius fractures fixed by 1 of 2 methods, either a standard dorsal nonlocked T-plate or a volar locked fixed-angle plate. DESIGN: Biomechanical cadaveric study. SETTING: Biomechanical testing laboratory. INTERVENTION: In 6 matched pairs of fresh-frozen cadaveric specimens, a simulated unstable extra-articular distal radius fracture was created. The fractures were stabilized with either a dorsal 3.5-mm stainless steel T-plate or a titanium locked volar fixed-angle plate. Specimens were axially loaded at 5 points (centrally, volarly, dorsally, radially, and ulnarly) and then cyclically loaded for 5000 cycles with an 80 N central load. Postcyclical loading, specimens were once again axially loaded at the 5 points. MAIN OUTCOME MEASURES: Initial fixation stiffness and stiffness after midaxial cyclical loading was compared at the 5 points. RESULTS: With the volar locked fixed-angle plate, fixation was significantly stiffer than with the dorsal nonlocked T-plate for ulnar and volar loading in single-cycle testing. After cyclic loading, the locked volar fixed-angle plate maintained more of its initial stiffness than the dorsal nonlocked T-plate. The dorsal 3.5-mm stainless steel T-plate's stiffness when dorsally loaded significantly decreased after cyclical loading. CONCLUSIONS: The volar locked fixed-angle plate maintained a greater percentage of its initial stiffness after cyclic loading compared to the dorsal nonlocked plate. Also, the volar locked plate was stiffer than the dorsal nonlocked plate for all loading configurations tested except when subjected to a dorsally applied eccentric load.

Adult↗

Boxer's Knuckle.

Tear of the dorsal capsule of a finger metacarpophalangeal joint is an uncommon injury that should be differentiated from an injury to the sagittal fibers of the extensor hood. While the latter injury can often be treated nonoperatively, a dorsal capsular injury usually requires surgery, particularly in athletes who are disabled by the injury.

Journal Article↗