PubMed Health⌕ Search

Biomedical subjects

Michael Terry

Publications and source records attributed to Michael Terry.

4 recordsLinked to original sources

Repair of palatal bone defects using osteogenically differentiated fat-derived stem cells.

BACKGROUND: Although autogenous bone grafting remains the standard in the reconstruction of bone defects, disadvantages may include limited amount of bone and donor-site morbidity. Tissue engineering approaches can potentially obviate these problems. Fat contains a population of stem cells that can be isolated and differentiated into various cell lines, including osteocytes, adipocytes, and myocytes, depending on the culture conditions. In this study, the authors used osteogenically differentiated fat-derived stem cells to repair rat palatal bone defects. METHODS: Fat-derived stem cells were isolated, differentiated into osteocytes in osteogenic medium, and seeded onto poly-L-lactic acid scaffolds. Rat palatal bone defects were surgically made and animals divided into four groups according to the type of implant for bone repair: group I, empty defect; group II, poly-L-lactic acid without cells; group III, poly-L-lactic acid with undifferentiated fat-derived stem cells; and group IV, poly-L-lactic acid with osteogenically differentiated fat-derived stem cells. Palates were harvested at 6 or 12 weeks after implantation (n = 8 per group at each time interval). Hematoxylin and eosin staining, immunohistochemical staining for osteocalcin, and histomorphometric measurements of new bone were performed. RESULTS: Defects in groups I, II, and III had no bone and were primarily filled with fibrous tissue. In contrast, there was substantial bone regeneration in group IV, which was statistically significant by histomorphometry compared with groups I, II, and III. Newly formed bone in group IV stained positive for osteocalcin. CONCLUSIONS: The authors successfully reconstructed palatal bone defects using absorbable three-dimensional scaffolds seeded with osteogenically differentiated fat-derived stem cells. This study demonstrates the feasibility of reconstructing bony defects with fat-derived stem cells.

Adipocytes↗

A dual closed-loop control system for mechanical ventilation.

OBJECTIVE: Closed-loop mechanical ventilation has the potential to provide more effective ventilatory support to patients with less complexity than conventional ventilation. The purpose of this study was to investigate the effectiveness of an automatic technique for mechanical ventilation. METHODS: Two closed-loop control systems for mechanical ventilation are combined in this study. In one of the control systems several physiological data are used to automatically adjust the frequency and tidal volume of breaths of a patient. This method, which is patented under US Patent number 4986268, uses the criterion of minimal respiratory work rate to provide the patient with a natural pattern of breathing. The inputs to the system include data representing CO2 and O2 levels of the patient as well as respiratory compliance and airway resistance. The I:E ratio is adjusted on the basis of the respiratory time constant to allow for effective emptying of the lungs in expiration and to avoid intrinsic positive end expiratory pressure (PEEP). This system is combined with another closed-loop control system for automatic adjustment of the inspired fraction of oxygen of the patient. This controller uses the feedback of arterial oxygen saturation of the patient and combines a rapid stepwise control procedure with a proportional-integral-derivative (PID) control algorithm to automatically adjust the oxygen concentration in the patient's inspired gas. The dual closed-loop control system has been examined by using mechanical lung studies, computer simulations and animal experiments. RESULTS: In the mechanical lung studies, the ventilation controller adjusted the breathing frequency and tidal volume in a clinically appropriate manner in response to changes in respiratory mechanics. The results of computer simulations and animal studies under induced disturbances showed that blood gases were returned to the normal physiologic range in less than 25 s by the control system. In the animal experiments understeady-state conditions, the maximum standard deviations of arterial oxygen saturation and the end-tidal partial pressure of CO2 were +/- 1.76% and +/- 1.78 mmHg, respectively. CONCLUSION: The controller maintained the arterial blood gases within normal limits under steady-state conditions and the transient response of the system was robust under various disturbances. The results of the study have showed that the proposed dual closed-loop technique has effectively controlled mechanical ventilation under different test conditions.

Algorithms↗

Helium-oxygen therapy for pediatric acute severe asthma requiring mechanical ventilation.

OBJECTIVE: To illustrate the use of helium-oxygen gas mixtures as therapy for pediatric patients with acute severe asthma requiring conventional mechanical ventilation. DESIGN: Retrospective review. SETTING: Tertiary care children's teaching hospital. PATIENTS: All mechanically ventilated patients with severe asthma admitted to the pediatric intensive care unit from August 1994 to October 2000. INTERVENTIONS: Within 24 hrs of intubation or admission, patients were stabilized on volume ventilation, bronchodilator therapy, corticosteroids, and antibiotics when indicated. Hypercapnia was permitted while maintaining arterial blood gas pH > or =7.25. A helium-oxygen gas mixture then was begun with helium flow set at 5-7 L/min, and oxygen flow was titrated to maintain desired oxygen saturation. Only sedated, chemically paralyzed patients with adequate pre-helium-oxygen and post-helium-oxygen measurements were statistically analyzed. MEASUREMENTS AND MAIN RESULTS: Twenty-eight mechanically ventilated patients with severe asthma placed on helium-oxygen gas mixtures were identified who met study entry criteria. Mean patient age was 8.8 yrs (range, 1.1-14.6). Before helium-oxygen therapy began, mean peak inspiratory pressure was 40.5 +/- 4.2 cm H(2)O, mean arterial blood gas pH was 7.26 +/- 0.05, and mean CO(2) partial pressure was 58.2 +/- 8.5 torr. After patients were placed on helium-oxygen therapy, there was a significant decrease in mean peak inspiratory pressure to 35.3 +/- 3.0 cm H(2)O. Mean pH increased significantly to 7.32 +/- 0.06, and mean partial pressure CO(2) decreased significantly to 50.5 +/- 7.4 torr. Initial mean inspired helium was 57 +/- 4% (range, 32-74). Mechanical ventilation days ranged from 1 to 23 days (mean, 5.0). Hospital stay ranged from 4 to 29 days (mean, 10.1), with an average pediatric intensive care unit stay of 6.9 days (range, 2-24). There were two incidences of pneumothorax. CONCLUSIONS: In the pediatric patient with severe asthma requiring conventional mechanical ventilation, helium-oxygen administration appears to be a safe therapy and may assist in lowering peak inspiratory pressure and improving blood gas pH and partial pressure CO(2).

Acute Disease↗

Closed-loop control if the inspired fraction of oxygen in mechanical ventilation.

OBJECTIVE: Supplemental oxygen treatment of patients on mechanical ventilation is crucial in maintaining the patients' oxygen levels in the normal range. The purpose of this study was to evaluate the effectiveness of a closed-loop controller for automatic adjustment of the fraction of inspired oxygen, FIO2. More specifically, the aim of the study was to assess the robustness of the controller in correcting hypoxemia as well as its effectiveness in prevention of hyperoxemia and oxygen toxicity. METHODS: The microprocessor-based feedback control system combines a rapid control algorithm with a proportional-integral-derivative (PID) control procedure to automatically adjust FIO2. The system is designed to prevent hypoxemia by applying a stepwise control procedure in response to rapid declines in arterial oxygen saturation while fine-tuning FIO2 and avoiding hyperoxemia by resuming to the PID control procedure when appropriate. The system includes a sophisticated safeguard unit which is designed to communicate any oxygenation problems or measurement artifacts to the medical personnel while keeping FIO2 at a safe and sufficiently high level. The control system has been tested by using computer simulations as well as animal studies. RESULTS: In response to different disturbances, the arterial oxygen saturation returned to the normal safe range within less than 20 seconds, thereby avoiding any untoward effects of hypoxemia. Under steady state conditions, the variations in arterial oxygen saturation were kept within +/- 3% of the mean value. The controller corrected hypoxemia within seconds while preventing hyperoxemia, rejecting artifacts, and minimizing exposure to high concentrations of oxygen. CONCLUSION: The results of the study attest to the reliability of the proposed closed-loop control scheme for automatic adjustment of FIO2. Further evaluation of the controller will require testing the effectiveness of the system on different patient groups.

Algorithms↗