High-throughput sorting and analysis of human sperm with a ring-shaped laser trap.

Sperm motility is an important concept in fertility research. To this end, single spot laser tweezers have been used to quantitatively analyze the motility of individual sperm. However, this method is limited with throughput (single sperm per spot), lacks the ability of in-situ sorting based on motility and chemotaxis, requires high laser power (hundreds of milliWatts) and can not be used to dynamically monitor changes in sperm swimming behavior under the influence of a laser beam. Here, we report a continuous 3-D ring-shaped laser trap which could be used for multi-level and high-throughput (tens to hundred sperm per ring) sperm sorting based on their motility and chemotaxis. Under a laser power of only tens of milliWatts, human sperm with low to medium velocity are slowed down, stopped, or forced to change their trajectories to swim along the ring due to the optical gradient force in the radial direction. This is the first demonstration of parallel sperm sorting based on motility with optical trapping technology. In addition, by making the sperm swimming along the circumference of the ring, the effect of laser radiation, optical force and external obstacles on sperm energetics are investigated in a more gentle and quantitative way. The application of this method could be extended to motility and bio-tropism studies of other self-propelled cells, such as algae and bacteria.

Cell Separation↗

Size tunable three-dimensional annular laser trap based on axicons.

A three-dimensional (3D) ring-shaped laser trap has been built using axicons. The diameter of this laser trap ranges from 70 to 140 mum and is adjusted by simply changing the position of one axicon in the optical path. Parallel 3D trapping of 5 mum silica microspheres and 3D confinement of cells along the ring are demonstrated. In this system the special optical properties of axicons are used to create a continuous annular trap with high power efficiency and a constant numerical aperture. This new approach, without any mechanical scanning, offers significant potential for applications in cell motility analysis and biotropism studies.

Equipment Design↗

Dynamically adjustable annular laser trapping based on axicons.

To study the chemotactic response of sperm to an egg and to characterize sperm motility, an annular laser trap based on axicons is designed, simulated with the ray-tracing tool, and implemented. The diameter of the trapping ring can be adjusted dynamically for a range of over 400 microm by simply translating one axicon along the optical axis. Trapping experiments with microspheres and dog sperm demonstrate the feasibility of the system, and the power requirement agrees with theoretical expectation. This new type of laser trapping could provide a prototype of a parallel, objective, and quantitative tool for animal fertility and biotropism study.

Animals↗

In vivo quantitative studies of dynamic intracellular processes using fluorescence correlation spectroscopy.

It has been a significant challenge to quantitatively study the dynamic intracellular processes in live cells. These studies are essential for a thorough understanding of the underlying mechanisms regulating the signaling pathways and the transitions between cell cycle stages. Our studies of Cdc20, an important mitotic checkpoint protein, throughout the cell cycle demonstrate that fluorescence correlation spectroscopy is a powerful tool for in vivo quantitative studies of dynamic intracellular processes. In this study, Cdc20 is found to be present primarily in a large complex (>1 Mda) during interphase with a diffusion constant of 1.8+/-0.1 microm2/s and a concentration of 76+/-24 nM, consistent with its association with the APC/C. During mitosis, however, a proportion of Cdc20 dissociates from APC/C at a rate of 12 pM/s into a soluble pool with a diffusion constant of 19.5+/-5.0 microm2/s, whose size is most consistent with free Cdc20. This free pool accumulates to 50% of total Cdc20 (approximately 40 nM) during chronic activation of the mitotic checkpoint but disappears during mitotic exit at a rate of 31 pM/s. The observed changes in the biochemical assembly states of Cdc20 closely correlate to the known temporal pattern of the activity of APC/CCdc20 in mitosis. Photon counting histograms reveal that both complexes contain only a single molecule of Cdc20. The underlying mechanisms of the activities of APC/CCdc20 throughout the cell cycle are discussed in light of our experimental observations.

Cdc20 Proteins↗

Real-time automated tracking and trapping system for sperm.

We have developed a microscope system for real-time single sperm tracking with an automated laser tweezers escape power assay. Phase contrast images of swimming sperm are digitized to the computer at video rate. The custom algorithm creates a region of interest centered about a sperm in response to a mouse click and performs all subsequent tasks autonomously. Microscope stage movement responds to feedback from video analysis of swimming sperm to center the sperm with respect to the field of view. For escape power assays, sperm are automatically relocated to the laser trap focus where they are held for a user-defined duration at fixed power, or held as laser power is gradually reduced. The sperm's position is automatically monitored to measure the laser power at which the sperm escapes the trap. Sperm are tracked for extended durations before and after laser trap experiments. Motility measurements including the curvilinear velocity and the absolute position of the sperm relative to the cell chamber are calculated and written to the hard drive at video rate. Experimental throughput is increased over 30 times compared to off-line data analysis. The efficacy of the "track and trap" algorithm is validated through examples and comparisons with the manually collected data.

Animals↗

Visualizing the mechanical activation of Src.

The mechanical environment crucially influences many cell functions. However, it remains largely mysterious how mechanical stimuli are transmitted into biochemical signals. Src is known to regulate the integrin-cytoskeleton interaction, which is essential for the transduction of mechanical stimuli. Using fluorescent resonance energy transfer (FRET), here we develop a genetically encoded Src reporter that enables the imaging and quantification of spatio-temporal activation of Src in live cells. We introduced a local mechanical stimulation to human umbilical vein endothelial cells (HUVECs) by applying laser-tweezer traction on fibronectin-coated beads adhering to the cells. Using the Src reporter, we observed a rapid distal Src activation and a slower directional wave propagation of Src activation along the plasma membrane. This wave propagated away from the stimulation site with a speed (mean +/- s.e.m.) of 18.1 +/- 1.7 nm s(-1). This force-induced directional and long-range activation of Src was abolished by the disruption of actin filaments or microtubules. Our reporter has thus made it possible to monitor mechanotransduction in live cells with spatio-temporal characterization. We find that the transmission of mechanically induced Src activation is a dynamic process that directs signals via the cytoskeleton to spatial destinations.

Actin Cytoskeleton↗

Internet-based robotic laser scissors and tweezers microscopy.

We have engineered a robotic laser ablation and tweezers microscope that can be operated via the internet using most internet accessible devices, including laptops, desktop computers, and personal data assistants (PDAs). The system affords individual investigators the ability to conduct micromanipulation experiments (cell surgery or trapping) from remote locations (i.e., between the US and Australia). This system greatly expands the availability of complex and expensive research technologies via investigator-networking over the internet. It serves as a model for other "internet-friendly" technologies leading to large scale networking and data-sharing between investigators, groups, and institutions on a global scale. The system offers three unique features: (1) the freedom to operate the system from any internet-capable computer, (2) the ability to image, ablate, and/or trap cells and their organelles by "remote-control," and (3) the security and convenience of controlling the system in the laboratory on the user's own personal computer and not on the host machine. Four "proof of principle" experiments were conducted: (1) precise control of microscope movement and live cell visualization, (2) subcellular microsurgery on the microtubule organizing center of live cells viewed under phase contrast and fluorescence microscopy, (3) precise targeting of multiple sites within single red blood cells, and (4) optical trapping of 10 microm diameter polystyrene microspheres.

Internet↗

A polarity dependent fluorescence "switch" in live cells.

The spectroscopic properties, ultrafast kinetics and utilization of a photochromic molecule as a bi-stable fluorescing sensor of polarity in live cells are described. This molecule is a photochromic fulgimide, 2,3-dialkylidenesuccinimide, which emits fluorescence that can be switched optically on and off. The fluorescence intensity is a function of the polarity of the molecular environment, namely it fluoresces strongly when the molecule is in its polar isomeric structure form. We demonstrate that this molecule enters live cells without inducing damage, it binds primarily to internal membranous organelles (mitochondria) and its fluorescence can be switched optically "on" and "off" repeatedly while inside the living cell. A possible use as a bi-stable, on/off sensor is discussed.

Animals↗

Photodynamic parameters in the chick chorioallantoic membrane (CAM) bioassay for photosensitizers administered intraperitoneally (IP) into the chick embryo.

The chick chorioallantoic membrane (CAM) assay was used to determine the photodynamic response (PDR) of blood vessels to Photofrin, 5-aminolevulinic acid (ALA), benzoporphyrin derivative monoacid ring A (BPD-MA) and lutetium texaphyrin (Lutex). The photosensitizers were administered systemically via intraperitoneal injection into the chick embryo. Forward stepwise regression analysis of the PDR results enabled the individual contributions of seven experimental variables to be ranked: drug dose, light dose, fluence rate, drug uptake time, vessel type (whether arterioles or venules), vessel diameter, and embryo age. The order of importance of the variables, the PDR profile, was determined for each photosensitizer. Relative contributions of the experimental variables from this study to the CAM PDR were compared with those from our previous study on PDR of CAM blood vessels following topical application of the same photosensitizers. PDR profiles were interpreted in terms of biophysical and biochemical characteristics of the individual photosensitizers and the variation in their interactions with the delivery/distribution environment.

Allantois↗

Fluorescence correlation spectroscopy investigation of a GFP mutant-enhanced cyan fluorescent protein and its tubulin fusion in living cells with two-photon excitation.

This study investigates the feasibility of using the enhanced cyan mutant of green fluorescent protein (ECFP) as a probe for two-photon fluorescence correlation spectroscopy (FCS). Molecular dynamics and other properties of ECFP and an ECFP-tubulin fusion protein were investigated in living Potorous tridactylis (PTK2) cells. ECFP has high molecular brightness in the nucleus (eta=3.3 kcpsm) and in the cytoplasm (3.2 kcpsm) under our experimental conditions. The diffusion constants of ECFP were determined to be 20+/-7 microm(2)/s in the nucleus and 21+/-8 microm(2)/s in the cytoplasm. ECFP has stable molecular characteristics with negligible photobleaching and photodynamic effects in our measurements. At the highest concentration of monomer ECFP (425 nM) the amount of dimer ECFP was estimated to be negligible ( approximately 1.8 nM), consistent with our data analysis using a single species model. ECFP-tubulin has a diffusion constant of 6 microm(2)/s in the living cells. In addition, we demonstrate that analysis of the molecular brightness can provide a new avenue for studying the polymerization state of tubulin. We suggest that the tubulin in the vicinity of the nucleus exists primarily as a heterodimer subunit while those in the area away from the nucleus (d>5 microm) are mostly oligomers. We conclude that ECFP is a useful genetic fluorescent probe for FCS studies of various cellular processes when in fusion to other biomolecules of interest.

Animals↗

Analysis of sperm motility using optical tweezers.

This study examines the use of optical trapping as a quantitative measure of sperm motility. The effects of laser trap duration and laser trapping power on sperm motility are described between sperm swimming force, swimmimg speed, and speed of progression (SOP) score. Sperm (SOP scores of 2-4) were trapped by a continuous-wave 1064 nm single-point gradient laser trap. Trap duration effects were quantified for 15, 10, and 5 seconds at 420 mW laser power. Laser power effects were quantified at powers of 420 mW, 350 mW, 300 mW, and 250 mW for five seconds. Swimming force, swimming speed, and SOP score relationships were examined at a trap duration and trapping power shown to minimally affect sperm motility. Swimming forces were measured by trapping sperm and subsequently decreasing laser power until the sperm escaped the trap. Swimming trajectories were calculated by custom-built software, and SOP scores were assigned by three qualified sperm scoring experts. A ubiquitous class of sperm were identified that swim with relatively high forces that are uncorrelated to swimming speed. It is concluded that sperm swimming forces measured by optical trapping provide new and valuable quantitative information to assess sperm motility.

Animals↗

Computer-based tracking of single sperm.

This paper describes a robust single sperm tracking algorithm (SSTA) that can be used in laser optical trapping and sperm motility studies. The algorithm creates a region of interest (ROI) centered about a sperm selected by the user. SSTA contrast enhances the ROI image and implements a modified four-class thresholding method to extract the tracked sperm as it transitions in and out of focus. The nearest neighbor method is complemented with a speed-check feature to aid tracking in the presence of additional sperm or other particles. SSTA has a collision-detection feature for real or perceived collision or near-miss cases between two sperm. Subsequent postcollision analysis employs three criteria to distinguish the tracked sperm in the image. The efficacy of SSTA is validated through examples and comparisons to commercially available computer-aided sperm tracking systems.

Algorithms↗