PubMed Health⌕ Search

Biomedical subjects

Michael Zimmermann

Publications and source records attributed to Michael Zimmermann.

At least 19 recordsLinked to original sources

A Novel De Novo STAG1 Variant at the RAD21 Binding Interface Is Associated With Hypoglycemia, Recurrent Fever, Immunodeficiency and Features of Classical Cohesinopathies.

The cohesin complex, composed of SMC1, SMC3, RAD21, and STAG1/STAG2, is essential for chromosome cohesion, DNA repair, and transcriptional regulation. Pathogenic variants in cohesin components cause cohesinopathies. The classical characteristics of cohesinopathies include developmental delay (DD), intellectual disability (ID), feeding difficulties, hypotonia, short stature, hearing loss, and dysmorphic features. Here, we present a 5-year-old boy with classical cohesinopathy features, including DD/ID and feeding difficulties, along with non-classical features such as hypoglycemia, recurrent fever, and immunodeficiency. Trio exome sequencing identified a novel de novo missense variant of uncertain significance (NM_005862.3:c.643G>A(p.Val215Ile)) in the STAG1 gene. The variant localizes to the RAD21 interaction interface, and molecular dynamics (MD) simulations revealed conformational changes comparable to other STAG1 variants reported as likely pathogenic in patients, supporting a deleterious effect which may disrupt the STAG1-RAD21 interaction interface. This case expands the phenotypic and molecular spectrum of STAG1-related cohesinopathy and advances our understanding of the disease mechanism.

STAG1↗

Computed tomographic enterography adds information to clinical management in small bowel Crohn's disease.

BACKGROUND: CT enterography yields striking findings in the bowel wall in Crohn's disease. These images may help to evaluate whether small bowel narrowing results from active disease requiring anti-inflammatory therapy. However, the clinical relevance of these images is unknown. It is also not known if these radiologic findings correlate with objective biomarkers of inflammation. METHODS: In a blinded and independent evaluation, IBD subspecialty gastroenterologists reviewed clinical data, and CT radiologists reviewed CT enterography scans of 67 consecutive patients with Crohn's disease and suspicion of either small bowel inflammation or stricture. Comparisons were made between (1) clinical and radiologic assessments of inflammation and stricture, (2) clinical assessments before and after computed tomographic enterography (CTE) reports were revealed, and (3) radiologic findings and objective biomarkers of inflammation. RESULTS: (1) Individual CTE findings correlated poorly (Spearman's rho < 0.30) with clinical assessment; (2) clinicians did not suspect 16% of radiologic strictures, and more than half the cases of clinically suspected strictures did not have them on CTE; (3) CTE data changed clinicians' perceptions of the likelihood of steroid benefit in 41 of 67 cases; (4) specific CTE findings correlated with CRP, and a distinct set of CTE findings correlated with ESR in the subset of patients who had these biomarkers measured. CONCLUSIONS: CTE seems to add unique information to clinical assessment, both in detecting additional strictures and in changing clinicians' perceptions of the likelihood of steroids benefiting patients. The biomarker correlations suggest that CTE is measuring real biologic phenomena that correlate with inflammation, providing information distinct from that in a standard clinical assessment.

Constriction, Pathologic↗

A new method for estimating the retention of selected smoke constituents in the respiratory tract of smokers during cigarette smoking.

This report describes a new method for estimating the retention of selected mainstream smoke constituents in the respiratory tract of adult smokers during cigarette smoking. Both particulate-phase (PP) constituents including nicotine, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), and N'-nitrosonornicotine (NNN), two tobacco-specific nitrosamines (TSNA), and gas-vapor-phase (GVP) constituents including carbon monoxide (CO), isoprene (IP), acetaldehyde (AA), and ethylene, were studied. To estimate the amounts of smoke constituents delivered during smoking, we used predetermined linear relationships between the measured cigarette filter solanesol content and machine-generated mainstream deliveries of these selected compounds. To determine the amounts of smoke constituents exhaled, the expired breath was directed through a Cambridge filter pad (CFP) attached to an infrared spectrometer. PP compounds were trapped on the CFP for later analysis and GVP compounds were analyzed in near real time. The smokers' respiratory parameters during smoking, such as inhalation/exhalation volume and time, were monitored using LifeShirt(R), a respiratory inductive plethysmography (RIP) device. The retention of each smoke constituent, expressed as a percentage, was then calculated as the difference between the amount delivered (estimated) and the amount exhaled relative to the amount delivered. We studied 16 adult male smokers who smoked cigarettes according to 3 predefined smoking patterns: no inhalation (pattern A), normal inhalation (pattern B), and deep inhalation (pattern C). For the three PP constituents, the mean retentions for pattern A ranged between 10 and 20%; and while the mean retentions of the two TSNAs were significantly higher for pattern C (84% for NNK and 97% for NNN) than those for pattern B (63% for NNK and 84% for NNN), the mean retentions of nicotine were basically the same between patterns B and C, which were both greater than 98%. For the GVP constituents, the retentions were similar between pattern B and pattern C, although different constituents were retained to different degrees (average values of 33%, 52%, 79%, and 99% for ethylene, IP, CO, and AA, respectively). The differences in the retention between different constituents could be interpreted in terms of each constituent's physical properties such as volatility and solubility. In conclusion, the method described is suitable for studying the retention of selected mainstream smoke constituents in the respiratory tract of smokers.

Acetaldehyde↗

Persistence of the nitric oxide-dependent vasodilator pathway of cerebral vessels after experimental subarachnoid hemorrhage.

OBJECTIVE: Efficiency of the treatment of cerebral vasospasm (CVS) after subarachnoid hemorrhage (SAH) by interfering with the nitric oxide-cyclic guanosine monophospate (cGMP) pathway seems to be inconsistent. So far, it remains unclear whether or not insufficient access to the drugs or impaired reactivity of the vessels is responsible for this inconsistency. Therefore, the aim of the present investigation was to characterize this pathway on cerebral arteries during CVS. METHODS: CVS was induced using the rat double hemorrhage model and was determined by magnetic resonance perfusion weighted imaging. Rats were sacrificed on Day 3 and Day 5 after SAH. Immunohistochemical staining of the basilar artery for endothelial nitric oxide synthases and the alpha- and beta-subunits of the soluble guanylate cyclase was performed. Basilar artery ring segments on Day 5 were used for measurement of isometric force. Concentration effect curves for acetylcholine, sodium nitroprusside, and 8-bromo-cGMP were constructed and compared by maximum effect and pD2. RESULTS: The immunohistochemical expression of endothelial nitric oxide synthase was comparable in all groups. The soluble guanylate cyclase alpha- and beta-subunits were significantly diminished on Day 3, but recovered by Day 5. The relaxation attributable to acetylcholine and 8-bromo-cGMP was virtually identical in controls and during CVS. Relaxation attributable to sodium nitroprusside, however, was significantly enhanced after SAH (maximum effect, control: 88 +/- 12%; Day 5: 117 +/- 26%). CONCLUSION: The present investigations suggest the persistence of endothelium-, nitric oxide-, and cGMP-dependent relaxation during CVS. Therefore, the treatment of CVS interfering with this pathway seems not to be limited by alterations inside the vessel wall.

Animals↗

Time course in the development of cerebral vasospasm after experimental subarachnoid hemorrhage: clinical and neuroradiological assessment of the rat double hemorrhage model.

OBJECTIVE: The "double hemorrhage" model in the rat is frequently used to simulate delayed cerebral vasospasm (CVS) after subarachnoid hemorrhage (SAH) in humans. However, an exact neurological and angiographic characterization of the CVS is not available for this model so far and is provided in the present investigation. Additionally, perfusion weighted imaging (PWI) at 3 tesla magnetic resonance (MR) tomography was implemented to assess the reduction in cerebral blood flow (CBF). METHODS: In a prospective, randomized setting CVS was induced by injection of 0.2 ml autologous blood twice in the cisterna magna of 45 male Sprague-Dawley rats. The surviving animals were examined on Days 2, 3, 5, 7 and 9 and compared to a sham operated control group (n = 9). Rats were neurologically graded between 0 and 3, followed by MRI and selective digital subtraction angiography (DSA). The relative CBF was set in relation to the perfusion of the masseter muscle. RESULTS: The neurological state was significantly worsened on Day 2 (Grade 3), 3 (Grade 3), and 5 (Grade 2) (medians). The relative CBF/muscle BF ratio (2.5 +/- 0.8 (SAH) versus 9.2 +/- 1.3 (sham) (mean +/- SEM) and the basilar artery (BA) diameter (0.15 +/- 0.02 mm (SAH) versus 0.32 +/- 0.01 mm (sham) were significantly decreased on Day 5. Correlation between relative CBF/muscle BF ratio and BA diameter was 0.70. CONCLUSION: A valid and reproducible CVS simulation was proven by neurological score, DSA, and PWI on Day 5. Furthermore, our data demonstrate the practicability and validity of MR PWI for the monitoring of CVS in a rat SAH model.

Angiography, Digital Subtraction↗

Cerebrovascular characterization of clazosentan, the first nonpeptide endothelin receptor antagonist clinically effective for the treatment of cerebral vasospasm. Part I: inhibitory effect on endothelin(A) receptor-mediated contraction.

OBJECT: The central role of endothelin (ET)-1 in the development of cerebral vasospasm after subarachnoid hemorrhage is indicated by the successful treatment of this vasospasm in several animal models by using selective ET(A) receptor antagonists. Clazosentan is a selective ET(A) receptor antagonist that provides for the first time clinical proof that ET-1 is involved in the pathogenesis of cerebral vasospasm. The aim of the present investigation was, therefore, to define the pharmacological properties of clazosentan that affect ET(A) receptor-mediated contraction in the cerebrovasculature. METHODS: Isometric force measurements were performed in rat basilar artery (BA) ring segments with (E+) and without (E-) endothelial function. Concentration effect curves (CECs) were constructed by cumulative application of ET-1 or big ET-1 in the absence or presence of clazosentan (10(-9), 10(-8), and 10(-7) M). The inhibitory potency of clazosentan was determined by the value of the affinity constant (pA2). The CECs for contraction induced by ET-1 and big ET-1 were shifted to the right in the presence of clazosentan in a parallel dose-dependent manner, which indicates competitive antagonism. The pA2 values for ET-1 were 7.8 (E+) and 8.6 (E-) and the corresponding values for big ET-1 were 8.6 (E+) and 8.3 (E-). CONCLUSIONS: The present data characterize clazosentan as a potent competitive antagonist of ET(A) receptor-mediated constriction of the cerebrovasculature by ET-1 and its precursor big ET-1. These functional data may also be used to define an in vitro profile of an ET receptor antagonist with a high probability of clinical efficacy.

Animals↗

Cerebrovascular characterization of clazosentan, the first nonpeptide endothelin receptor antagonist shown to be clinically effective for the treatment of cerebral vasospasm. Part II: effect on endothelin(B) receptor-mediated relaxation.

OBJECT: The disturbed balance between nitric oxide and endothelin (ET)-1 in the cerebrovasculature seems to play a major role in the development of cerebral vasospasm after subarachnoid hemorrhage. Endothelin-1 represents the contractile part in this balance. In addition to the prevailing ET(A) receptor-dependent contractile effect, ET-1 also has ET(B) receptor-mediated vasodilatory attributes. The aim of the present study was to define the actual selectivity of clazosentan, the first putative highly ET(A) receptor-selective antagonist clinically proven to be effective in the treatment of vasospasm in the cerebrovasculature. METHODS: Rat basilar artery ring segments with endothelial function were used for the measurement of isometric force. Concentration effect curves were constructed by cumulative application of sarafotoxin S6c, ET-1, or big ET-1 in the presence or absence of clazosentan (10(-9) to 10(-6) M) after a precontraction was induced by prostaglandin F2alpha. The inhibition by clazosentan was estimated by the value of the affinity constant (pA2). The relaxation induced by sarafotoxin S6c, ET-1, and big ET-1 was inhibited in a competitive manner by clazosentan, yielding pA2 values of 7.1, 6.7, and 6.5, respectively. The selectivity to the ET(A) receptor in the cerebrovascular system was approximately two logarithmic units. CONCLUSIONS: The present investigation shows a competitive inhibition of ET(B) receptor-mediated relaxation in cerebral vessels by clazosentan in therapeutically relevant concentrations. Thus, additional clinical trials should be undertaken to evaluate clazosentan concentrations in cerebrospinal fluid. Furthermore, the present data may be taken to describe the pharmacological properties for an ET receptor antagonist specifically tailored for the treatment of pathological conditions of impaired cerebral blood flow.

Animals↗

Relative importance of hypertension compared with hypervolemia for increasing cerebral oxygenation in patients with cerebral vasospasm after subarachnoid hemorrhage.

OBJECT: Hypervolemia and hypertension therapy is routinely used for prophylaxis and treatment of symptomatic cerebral vasospasm at many institutions. Nevertheless, there is an ongoing debate about the preferred modality (hypervolemia, hypertension, or both), the degree of therapy (moderate or aggressive), and the risk or benefit of hypervolemia, moderate hypertension, and aggressive hypertension in patients following subarachnoid hemorrhage. METHODS: Monitoring data and patient charts for 45 patients were retrospectively searched to identify periods of hypervolemia, moderate hypertension, or aggressive hypertension. Measurements of central venous pressure, fluid input, urine output, arterial blood pressure, intracranial pressure, and oxygen partial pressure (PO2) in the brain tissue were extracted from periods ranging from 1 hour to 24 hours. For these periods, the change in brain tissue PO2 and the incidence of complications were analyzed. During the 55 periods of moderate hypertension, an increase in brain tissue PO2 was found in 50 cases (90%), with complications occurring in three patients (8%). During the 25 periods of hypervolemia, an increase in brain oxygenation was found during three intervals (12%), with complications occurring in nine patients (53%). During the 10 periods of aggressive hypervolemic hypertension, an increase in brain oxygenation was found during six of the intervals (60%), with complications in five patients (50%). CONCLUSIONS: When hypervolemia treatment is applied as in this study, it may be associated with increased risks. Note, however, that further studies are needed to determine the role of this therapeutic modality in the care of patients with cerebral vasospasm. In poor-grade patients, moderate hypertension (cerebral perfusion pressure 80-120 mm Hg) in a normovolemic, hemodiluted patient is an effective method of improving cerebral oxygenation and is associated with a lower complication rate compared with hypervolemia or aggressive hypertension therapy.

Adult↗

S-100B protein as a serum marker of secondary neurological complications in neurocritical care patients.

There is growing evidence that S-100B protein measured by a simple blood test can be used as a novel biochemical marker of brain cell damage. The objective of our study was to investigate the potential of S-100B measurements to diagnose an acute neurological complication in the analgo-sedated and intubated intensive care patient and the impact on patient management. Serum S-100B levels were serially investigated in 246 neurocritical care patients. Venous blood samples for S-100B determination were obtained as soon as possible after admission and every 24 hours thereafter, for the duration of the stay at the neurocritical care unit. Blood samples were taken every morning as part of the routine laboratory investigation for analysis of S-100B using the immunoluminometric assay (AB Sangtec Medical, Bromma, Sweden) and a fully automated LIAISON system (Byk-Sangtec-Diagnostica, Dietzenbach, Germany) with a short time to result. The primary endpoint of our study was the occurrence of a severe neurological complication. Patients were admitted to the neurosurgical intensive care unit after routine major intracranial surgery in 116 cases (47%) and after a neurological or neurosurgical emergency in 130 cases (53%). Of the latter group, 79 patients (32%) underwent emergency surgery for evacuation or decompression of a space-occupying lesion before ICU admission. A severe neurological complication was defined as a new infarction, new hemorrhage or a newly developed progressive disease despite maximum therapy with a radiologically confirmed increase of mass lesion and midline shift. In 33 patients (13%) a complication with neurological deterioration occurred. All patients showed pathologically increased serum S-100B values (mean 2.00 microg/l, standard deviation 2.61 microg/l, range 0.31-9.66 microg/l). Twenty-eight of these patients (85%) showed S-100B increases >0.5 microg/l. In five cases (16%), the increase in S-100B was the first sign of neurological complication and prompted emergency computed tomography scanning. In another two cases, increasing S-100B values changed management decision towards a surgical intervention. The major finding of our study was the influence of serial S-100B measurement on actual management of the patient in 21% of cases with neurological complications.

Adolescent↗

Characterization of the potent combined endothelin(A/B)-antagonist PD 142893 on cerebral vessels.

A disturbed balance between endothelin (ET)-1 and nitric oxide (NO) seems to play a key role in the development of delayed cerebral vasospasm following subarachnoidal hemorrhage. Therefore, the effect of PD 142893 one of the first potent ET(A)- and ET(B)-receptor antagonists was characterized on the contraction and relaxation induced by ET-1 and bigET-1 on rat basilar artery (BA). Concentration-effect curves (CECs) were constructed by cumulative application of ET-1 or big ET-1 on BA ring segments with (E+) and without (E-) functionally intact endothelium. The effect of PD 142893 was determined by the modified pK(b) value and the shift between the CECs. PD 142893 inhibited the contraction by ET-1 and bigET-1. The pK(b)-values were for ET-1: 5.17 (E+) and 5.15 (E-) and for big ET-1: 5.34 (E+) and 5.57 (E-), respectively. A significant relaxation of pre-contracted segments by ET-1 or big ET-1 was neither observed in the presence nor in the absence of the receptor antagonist. The present data suggest a competitive inhibition of the ET(A)-receptor mediated contraction of cerebral arteries by PD 142893. The ET(B)-dependent relaxation of the cerebrovasculature is inhibited by PD 142893 at least in a comparable amount of contraction.

Animals↗

Functional magnetic resonance imaging-integrated neuronavigation: correlation between lesion-to-motor cortex distance and outcome.

OBJECTIVE: The integration of functional magnetic resonance imaging (fMRI) data into neuronavigation is a new concept for surgery adjacent to the motor cortex. However, the clinical value remains to be defined. In this study, we investigated the correlation between the lesion-to-fMRI activation distance and the occurrence of a new postoperative deficit. METHODS: fMRI-integrated "functional" neuronavigation was used for surgery around the motor strip in 54 patients. During standardized paradigms for hand, foot, and tongue movements, echo-planar imaging T2* blood oxygen level-dependent sequences were acquired and processed with BrainVoyager 2000 software (Brain Innovation, Maastricht, The Netherlands). Neuronavigation was performed with the VectorVision(2) system (BrainLAB, Heimstetten, Germany). For outcome analysis, patient age, histological findings, size of lesion, distance to the fMRI areas, preoperative and postoperative Karnofsky index, postoperative motor deficit, and type of resection were analyzed. RESULTS: In 45 patients, a gross total resection (>95%) was performed, and for 9 lesions (low-grade glioma, 4; glioblastoma, 5), a subtotal resection (80-95%) was achieved. The neurological outcome improved in 16 patients (29.6%), was unchanged in 29 patients (53.7%), and deteriorated in 9 patients (16.7%). Significant predictors of a new neurological deficit were a lesion-to-activation distance of less than 5 mm (P < 0.01) and incomplete resection (P < 0.05). CONCLUSION: fMRI-integrated neuronavigation is a useful concept to assess the risk of a new motor deficit after surgery. Our data suggest that a lesion-to-activation distance of less than 5 mm is associated with a higher risk of neurological deterioration. Within a 10-mm range, cortical stimulation should be performed. For a lesion-to-activation distance of more than 10 mm, a complete resection can be achieved safely. The visualization of fiber tracks is desirable to complete the representation of the motor system.

Adult↗

A new endotoxin adsorption device in Gram-negative sepsis: use of immobilized albumin with the MATISSE adsorber.

MATISSE is a new endotoxin (ET) adsorption system. It comprises the FRESENIUS hemoadsorption machine 4008 ADS to maintain the extracorporeal circuits and disposables including the MATISSE-adsorber based on macroporous beads immobilized with human serum albumin. In vivo and in vitro experiments with this new compound had shown favourable ET elimination properties. In a first study 19 healthy volunteers were included for the safety and tolerability of the endotoxin adsorber system. One single veno-venous hemoperfusion with this system was performed. Apheresis treatment with the human albumin immobilized adsorber seems to be safe and well tolerable in healthy volunteers. A slight decrease in platelet count as well as insulin level was observed. No serious adverse events were mentioned. Similar findings were made in an open uncontrolled trial in six patients with suspected Gram-negative sepsis. Here endotoxin adsorption seems to be safe and well tolerated without adsorber related major adverse events. In the last clinical trial including 145 patients mainly peritonitis patients (104), again no safety concerns were found during the apheresis. Trends in improvement of morbidity and organ dysfunction were found as well as efficient LPS removal in peritonitis patients. LPS whole blood immunoadsorption is a promising new method. No relevant side effects were observed so far. A large controlled study to prove clinical efficacy in patients with severe sepsis and confirmed endotoxemia (e.g. peritonitis) should be necessary.

Adsorption↗

Near-infrared indocyanine green video angiography: a new method for intraoperative assessment of vascular flow.

OBJECTIVE: We report our initial clinical experience with a new method for intraoperative blood flow assessment. The purposes of the study were to assess the use of indocyanine green (ICG) video angiography in neurovascular cases, to assess the handling and image quality, to compare the findings with postoperative angiographic results, and to evaluate the clinical value of the method in a preliminary feasibility study. METHODS: Fourteen patients with aneurysms (n = 12) or spinal (n = 1) or intracranial (n = 1) dural fistulae were included. Before and/or after aneurysm or dural fistula occlusion, ICG (25 mg) was injected intravenously. A near-infrared laser excitation light source (lambda = 780 nm) illuminated the operating field. The intravascular fluorescence of ICG (maximal lambda = 835 nm) was recorded by a nonintensified video camera, with optical filtering to block ambient and laser light for collection of only ICG-induced fluorescence. RESULTS: A total of 21 investigations were performed for 14 patients. For the 17 successful ICG video angiographic investigations, image quality and resolution were excellent, allowing intraoperative real-time assessment of the cerebral circulation. ICG angiographic results could be divided into arterial, capillary, and venous phases, comparable to those observed with digital subtraction angiography. In all cases, the postoperative angiographic results corresponded to the intraoperative ICG video angiographic findings. In three cases, the information provided by intraoperative ICG angiography significantly changed the surgical procedure. CONCLUSION: ICG video angiography is simple and provides real-time information on the patency of arterial and venous vessels of all relevant diameters, including small and perforating arteries (<0.5 mm), and the visible aneurysm sac. It may be a useful adjunct to improve the quality of neurovascular procedures and to document the intraoperative vascular flow.

Adolescent↗

Clinical evaluation of intraparenchymal Spiegelberg pressure sensor.

OBJECTIVE: The Spiegelberg 3-PN intraparenchymal pressure sensor was clinically evaluated. DESCRIPTION OF INSTRUMENTATION: The Spiegelberg intraparenchymal pressure sensor is a low-cost device that uniquely performs regular automatic zeroing in situ throughout the measurement period. OPERATIVE TECHNIQUE: The Spiegelberg sensor was inserted in 87 patients who required intracranial pressure monitoring as part of their routine management. Complications were assessed by postoperative computed tomographic scanning and clinical investigation. The automated zeroing procedure was assessed after implantation of the sensor and during long-term measurement. In five patients, the "gold standard' of intraventricular pressure was measured simultaneously and compared with the intraparenchymal or subdural Spiegelberg 3-PN pressure. EXPERIENCE AND RESULTS: No complications associated with the Spiegelberg sensor were observed. The duration of monitoring ranged from 3 to 28 days (mean, 10 d). In 3 patients, technical problems occurred, and in 84 patients, the pressure measurement was successful, including the automatic zeroing procedures performed by the monitor after insertion and hourly thereafter. The absolute difference between the Spiegelberg reading and the intraventricular pressure was less than +/-3 mm Hg in 99.6% and less than +/-2 mm Hg in 91.3% of readings. An Altman-Bland bias plot revealed good agreement between the two methods, with an average bias of 0.5 mm Hg, but revealed a significant trend toward 10% lower Spiegelberg readings with increasing intracranial pressure of >25 mm Hg. There was no difference between intraparenchymal and subdural locations. CONCLUSION: The Spiegelberg 3-PN sensor was reliable and simple to use. It can be recommended for routine intraparenchymal and subdural pressure measurement at a considerably lower price compared with other tip transducers and has the unique advantage of automated zeroing in vivo.

Brain Neoplasms↗

Measurements of serum S-100B protein: effects of storage time and temperature on pre-analytical stability.

Measurement of S-100B protein in serum or cerebrospinal fluid is increasingly used as a molecular marker of brain damage. However, there is no information about the pre-analytical in vitro stability of S-100B. We have investigated whether storing blood samples at different time periods and conditions affected the measured levels of S-100B protein. Blood samples were taken from 29 neurosurgical patients with normal serum S-100B values and from seven patients with increased serum S-100B values. Blood samples were immediately divided into nine aliquots for measuring S-100B immediately and after 4, 8, 12, and 24 hours, stored at room temperature or at 4 degrees C. Measurement of S-100B was performed using the LIAISON assay (Byk-Sangtec Diagnostica, Dietzenbach, Germany). Moreover, in 10 additional patients the effect of freezing the serum and thawing the sample after 24 hours was investigated. There were no differences between the results of S-100B measurements after storing the sample at different temperatures and time periods. There was no trend towards higher or lower values in all three groups. Therefore, blood samples may be collected as part of the daily clinical routine without time constraint and even stored overnight without affecting S-100B serum levels when measured with the LIAISON Sangtec 100 assay.

Blood Preservation↗

Automated fiducial marker detection for patient registration in image-guided neurosurgery.

OBJECTIVE: The registration of applied fiducial markers within the preoperative data is often left to the surgeon, who has to identify and tag the center of each marker. This is both time-consuming and a potential source of error. For this reason, the development of an automated procedure was desirable. In this study, we have investigated the accuracy of a software algorithm for detecting fiducial markers within the navigation data set. The influence of adjustable values for accuracy and threshold on the sensitivity and specificity of the detection process, as well as the time gain, was investigated. PATIENTS AND METHODS: One hundred MP-RAGE MRI data sets of patients with different pathologies who were scheduled for image-guided surgery were used in this study. A total of 591 applied fiducial markers were to be detected using the algorithm of the software VVPlanning 1.3 (BrainLAB, Heimstetten, Germany) on a Pentium II standard PC. The size value of a marker in the y-direction is called "accuracy" and depends on the slice thickness. "Threshold" describes the gray level above which the algorithm starts searching for pixel clusters. The threshold value was changed stepwise on the basis of a constant "accuracy" value. The "accuracy" value was changed on the basis of that threshold value at which all markers were detected correctly. RESULTS: The time needed for automatic detection varied between 12 s and 25 s. An optimum value for adjustable marker size was found to be 1.1 mm, with 8 undetected markers (1.35%) and 7 additionally detected structures (1.18%) out of 591. The mean gray level (Threshold) for all data sets above which marker detection was correct was 248.9. The automatic detection of markers was good for higher gray levels, with 11 missed markers (1.86%). Starting the algorithm at lower gray levels led to a decreased incidence of missed markers (0.17%), but increased the incidence of additionally detected structures to 27.92%. CONCLUSION: The automatic marker-detection algorithm is a robust, fast and objective instrument for reliable fiducial marker registration when used with optimum settings for both threshold and accuracy.

Adolescent↗