PubMed Health⌕ Search

Biomedical subjects

Michal Staninec

Publications and source records attributed to Michal Staninec.

9 recordsLinked to original sources

Adhesion of composite to enamel and dentin surfaces irradiated by IR laser pulses of 0.5-35 micros duration.

The characteristics of laser-treated tooth surfaces depend on the laser wavelength, pulse duration, spatial and temporal laser beam quality, incident fluence, surface roughness, and the presence of water during irradiation. Ablated surfaces are most commonly restored with adhesive dental materials and the characteristics of the ablated surfaces influence adhesion of restorative materials. Previous studies suggest that high bond strengths can be achieved using shorter laser pulses that minimize peripheral thermal damage. In this study, Er:YSGG, Er:YAG, and CO(2) lasers were used at irradiation intensities sufficient to simulate efficient clinical caries removal to uniformly irradiate bovine enamel and human dentin surfaces using a motion control system with a microprocessor-controlled water spray. The degree of spatial overlap of adjacent pulses was varied so as to investigate the influence of irradiation uniformity and surface roughness on the bond strength. Composite resin was bonded to the irradiated surfaces and shear bond tests were used to obtain bond strengths in MPa. The highest results were obtained using the Er:YAG pulses with pulse durations less than 35 mus without the necessity for postirradiation acid etching. Some of these groups were not significantly different from nonirradiated, acid-etch-only positive control groups.

Acrylic Resins↗

Selective targeting of protein, water, and mineral in dentin using UV and IR pulse lasers: the effect on the bond strength to composite restorative materials.

BACKGROUND AND OBJECTIVES: Previous studies have shown that during the laser irradiation of dentin and bone, thermal damage can be minimized by using a highly absorbed laser wavelength, laser pulses shorter than the thermal relaxation time of the deposited laser energy at that wavelength, and the addition of a layer of water to the tissue surface before ablation. The objective of this study was to investigate the influence of laser pulse duration and wavelength with and without the added water layer on the bond strength of composite to laser prepared dentin surfaces. The specific hypothesis that was tested was that thermal damage to the collagen matrix in dentin compromises the bond strength to composite restorative materials. STUDY DESIGN/MATERIALS AND METHODS: Three laser systems were employed that were tuned to water, collagen, and mineral absorption with pulse durations less than the thermal relaxation time of the deposited energy. The surfaces of human dentin were irradiated by laser irradiation from free-running and Q-switched Er:YSGG lasers, pulsed CO(2) lasers operating at 9.6-microm, and a Q-switched Nd:YAG laser operating at 355-nm. A motion control system and a pressurized spray system incorporating a microprocessor controlled pulsed nozzle for water delivery, were used to ensure uniform treatment of the entire surface. Shear bond testing was used to evaluate the adhesive strength in order to access the suitability of laser treated surfaces for bonding. Bonded interfaces were examined by SEM. RESULTS: All the laser groups had significantly lower bond strengths than the positive acid etch control group. The highest bond strengths were for the short pulse (< 5-microsecond) Er:YSGG and CO(2) laser groups with water. Laser groups without water had significantly reduced bond strengths and thicker layers of thermally damaged dentin. CONCLUSIONS: Thermal damage to the collagen matrix profoundly influences the bond strength to composite restorations.

Dental Bonding↗

Bonded amalgam sealants and adhesive resin sealants: five-year clinical results.

Bonded amalgams were used as pit-and-fissure sealants without mechanical preparation. They were compared with resin-based pit-and-fissure sealants for retention over a 5-year period. Clinical examinations at 6 months, 1 year, 2 years, and 5 years revealed no difference between the two techniques. Although amalgam sealants may not be practical by themselves, they can be used to seal pits and fissures surrounding very conservative preparations, in the "preventive amalgam restoration." Conventional amalgam retentive features and 90-degree cavosurface margins may not be necessary when bonding is used with amalgam.

Acid Etching, Dental↗

Influence of an optically thick water layer on the bond-strength of composite resin to dental enamel after IR laser ablation.

BACKGROUND AND OBJECTIVES: Several studies of hard tissue ablation with Er:YAG lasers have shown that the addition of an optically thick water layer ( approximately 1 mm) added to the surface of dental enamel before each incident laser pulse, profoundly influences the rate and efficiency of ablation and the resulting surface morphology. The objective of this study was the determination of laser parameters which result in clinically useful bond strengths without the need for phosphoric acid etching. The hypothesis to be tested was that laser irradiation through a relatively thick layer of water would result in a surface to which composite could be bonded with bond strength similar to surfaces etched with phosphoric acid. This hypothesis is predicated on the assumption that the water prevents the formation of non-apatite calcium phosphate phases on the enamel surface. MATERIALS AND METHODS: In this study, a calibrated syringe pump and a motion control system were used to uniformly treat flat enamel surfaces using free-running Er:YAG laser pulses with and without water, and 9.6 mum CO(2) laser pulses on a dry surface for comparison. The rate of water delivery that resulted in the most efficient ablation was determined by profiling the resulting laser incisions using optical coherence tomography. In addition, enamel surfaces of 5 x 5 mm(2) were uniformly treated and the resulting surface morphology was examined using synchrotron radiation-fourier transform infrared spectroscopy (SR-FTIR), and optical and electron microscopy. The influence of the modified surface morphology on the adhesion of composite resin was investigated. RESULTS: The shear-bond strength of composite bonded to enamel surfaces irradiated at intensities clinically relevant for caries removal approached values measured for conventional acid etching when the water delivery rate was optimized. CONCLUSIONS: This study demonstrates that composite restorative materials can be directly bonded to laser prepared surfaces without the necessity of further surface preparation and acid etching and that the addition of a thick water layer ( approximately 1 mm) prevents the formation of undesirable CaP phases that compromise adhesion to restorative materials. 2003.

Animals↗

Ultimate tensile strength of dentin: Evidence for a damage mechanics approach to dentin failure.

Dentin structure and properties are known to vary with orientation and location. The present study explored the variation in the ultimate tensile strength (UTS) of dentin with location in the tooth. Hourglass specimens were prepared from dentin located in the center, under cusps, and in the cervical regions of human molar teeth. These were tested in tension at various distances from the pulp. Median tensile strengths ranged from 44.4 MPa in the inner dentin near the pulp, to 97.8 MPa near the dentino-enamel junction (DEJ). This increase in the median UTS with distance from the pulp to the DEJ was statistically significant (P <.001). Of particular importance was the observation that the UTS measurements followed a Weibull probability distribution, with a Weibull modulus of about 4.5. The Weibull behavior of the UTS data strongly suggests that the large variances in fracture strength data result from a distribution of preexisting defects in the dentin. These findings justify a damage-mechanics approach to studies of dentin failure.

Biomechanical Phenomena↗

The integrity of bonded amalgam restorations: a clinical evaluation after five years.

BACKGROUND: Bonded amalgam restorations have been studied extensively in vitro, but few long term clinical studies exist. The authors examined the clinical performance of bonded amalgam restorations after five years of clinical service an compared it with that of nonbonded amalgam restorations. METHODS: The authors placed 75 bonded and 62 nonbonded amalgam restorations in patients needing restorations. Most of the restorations were placed in conventional preparations; six bonded restorations were placed in nonretentive cavities. They were evaluated after a five-year period of clinical service by two trained dentists using a mirror and explorer and following modified U.S. Public Health Service criteria. RESULTS: Statistical analysis (via Fisher exact test) showed no significant differences between the two techniques when conventional preparations were used. Restorations in nonretentive preparations were successful during this period. CONCLUSIONS: Bonded and nonbonded amalgam restorations yielded similar results in conventional preparations after five years of clinical service. Bonded amalgam restorations were clinically successful in a limited number of nonretentive preparations over a five-year period. CLINICAL IMPLICATIONS: Bonded amalgam restorations can be used successfully in conventional preparations and possibly in nonretentive preparations as well, and can be expected to last at least five years.

Dental Amalgam↗

Imaging artificial caries under composite sealants and restorations.

Polarization-sensitive optical coherence tomography (PS-OCT) is used to monitor the progression of simulated caries lesions on occlusal surfaces and image the lesions underneath composite sealants. The polarization-sensitive system, recording images in both the parallel and perpendicular axes, is useful for enhancing the image contrast of the artificial caries and minimizing the interference of the strong reflections at surface interfaces. Using the perpendicular-axis signal, the mean reflectivity increase from day 0 to day 14 is 5.1 dB (p<0.01, repeated-measures analysis of variation, Tukey-Kramer). For imaging lesions underneath the sealants, the mean reflectivity of the enamel underneath 250, 500, 750, and 1000 microm of composite is calculated for demineralized and control samples. The artificial lesions can be detected under 750 microm of visibly opaque sealant, with a 5.0-dB difference from the control samples (t-test, p<0.001). Tooth colored sealants allow deeper imaging depth. The artificial lesions could be detected under 1000 microm of sealant, with a 6.6-dB difference from the control samples (t-test, p<0.001). This study demonstrates that PS-OCT can be used to track lesion progression on occlusal surfaces nondestructively with or without sealants.

Artifacts↗

Colorimetric values of esthetic stainless steel crowns.

OBJECTIVES: The colorimetric values of two different kinds of esthetic stainless steel crowns were measured and compared with the colorimetric values of primary anterior teeth in Japanese children. METHOD AND MATERIALS: The colorimetric values of resin composite-faced stainless steel crowns (Kinder Krown) and epoxy-coated stainless steel crowns (White Steel Crown) were measured with a color difference meter. The Commission Internationale de Eclairage L*, a*, b*, and delta E*ab values and Munsell value, chroma, and hue were calculated. The data were compared with previously reported colorimetric values of Japanese primary anterior teeth measured with the same color difference meter used in this study. RESULTS: Compared to Japanese primary anterior teeth, Kinder Krown Pedo I and Pedo II showed much higher L* values and lower hue; on the other hand, White Steel Crown showed much higher L*, a*, b* values, much higher value and chroma, and much lower hue. CONCLUSION: Color analysis revealed that the colors of the White Steel Crown and Kinder Krown Pedo I were substantially different from the color of Japanese primary anterior teeth. The color difference between Pedo II crowns and Japanese primary anterior teeth was relatively high, but the color of Pedo II might be acceptable for clinical use.

Algorithms↗