Use of a curved-array transducer to reduce interobserver variation in sonographic measurement of thyroid volume in healthy adults.

PURPOSE: Sonographic calculation of thyroid volume is used in the diagnosis and follow-up of thyroid diseases. Since the calculated volume of thyroid lobes is highly influenced by the longest (ie, craniocaudal) diameter, we examined whether using a curved-array transducer as opposed to a linear-array transducer to measure the craniocaudal diameter would reduce interobserver variation. METHODS: Three sonographers with different levels of expertise each used a 5-12-MHz linear-array transducer and a 2-5-MHz curved-array transducer to measure the craniocaudal diameter of both thyroid lobes of 25 healthy volunteers. On the basis of these measurements, thyroid lobe volumes were calculated. Single-factor analysis of variance was used to evaluate the interobserver variations between the measurements made by all 3 observers as well as between measurements taken by pairs of observers. A p value of less than 0.05 was considered significant. RESULTS: Using the linear-array transducer to measure the craniocaudal diameter resulted in significant interobserver variation in thyroid volume calculation (p = 0.02), whereas using the convex-array transducer did not. Using either transducer resulted in a highly significant interobserver variation in measurements of the craniocaudal diameter, although the variation was far more pronounced for measurements made with the linear-array transducer (p = 0.0005) than for those made with the curved-array transducer (p = 0.04). For both transducers, the interobserver variations were most pronounced between the most and the least experienced sonographers. CONCLUSIONS: To avoid significant interobserver variation in calculating thyroid lobe volume, we recommend using a curved-array transducer to measure the craniocaudal diameter of the thyroid lobes.

Adult↗

Reducing inter-observer variation in thyroid volume calculation using a new formula and technique.

OBJECTIVE: Ultrasound (US) measurement of thyroid volume is used in diagnosis and follow-up of patients with thyroid disease. We assessed a new formula and technique for thyroid volume calculation, based on an automatically continuous trace transverse surface area (aTSA) calculation, to ascertain where this technique could reduce inter-observer variation. METHODS: Three observers with a different level of US expertise, using a 12-5 MHz linear transducer, examined 25 volunteers. Inter-observer variations were calculated for diameter measurements and for the thyroid lobe volume calculations using the single factor ANOVA method. RESULTS: Using the new technique and formula, no statistically significant differences existed, in contradistinction to using the classical formula for an ellipsoid (P=0.02). CONCLUSION: When thyroid volume measurements are required, we recommend using a new method of thyroid volume calculation based on the use of an automatically calculated continuous trace aTSA measurement to avoid significant inter-observer variation in calculation of thyroid lobe volumes.

Adult↗