Determination of polybrominated diphenyl ethers in environmental standard reference materials.

Standard reference materials (SRMs) are valuable tools in developing and validating analytical methods to improve quality assurance standards. The National Institute of Standards and Technology (NIST) has a long history of providing environmental SRMs with certified concentrations of organic and inorganic contaminants. Here we report on new certified and reference concentrations for 27 polybrominated diphenyl ether (PBDE) congeners in seven different SRMs: cod-liver oil, whale blubber, fish tissue (two materials), mussel tissue and sediment (two materials). PBDEs were measured in these SRMs, with the lowest concentrations measured in mussel tissue (SRM 1974b) and the highest in sediment collected from the New York/New Jersey Waterway (SRM 1944). Comparing the relative PBDE congener concentrations within the samples, we found the biota SRMs contained primarily tetrabrominated and pentabrominated diphenyl ethers, whereas the sediment SRMs contained primarily decabromodiphenyl ether (BDE 209). The cod-liver oil (SRM 1588b) and whale blubber (SRM 1945) materials were also found to contain measurable concentrations of two methoxylated PBDEs (MeO-BDEs). Certified and reference concentrations are reported for 12 PBDE congeners measured in the biota SRMs and reference values are available for two MeO-BDEs. Results from a sediment interlaboratory comparison PBDE exercise are available for the two sediment SRMs (1941b and 1944).

Journal Article↗

Development of a murre (Uria spp.) egg control material.

The Seabird Tissue Archival and Monitoring Project (STAMP) is a collaborative Alaska-wide effort by the US Fish and Wildlife Service's Alaska Maritime National Wildlife Refuge (USFWS/AMNWR), the US Geological Survey's Biological Resources Division (USGS/BRD), the Bureau of Indian Affairs Alaska Region Subsistence Branch (BIA/ARSB), and the National Institute of Standards and Technology (NIST) to monitor long-term (decadal) trends in environmental contaminants using seabird eggs. To support this effort, a matrix- (seabird egg) and concentration-specific control material was needed to ensure quality during analytical work. Although a herring gull egg quality assurance (HGQA) material is available from Environment Canada (EC), contaminant concentrations in this material tended to be higher than those observed in Alaskan murre (Uria spp.) eggs. Therefore, to prepare a more appropriate control material, a total of 12 common murre (U. aalge) and thick-billed murre (U. lomvia) eggs from four Bering Sea and Gulf of Alaska nesting locations were cryohomogenized to create 190 aliquots each containing approximately 6 g. This new control material was analyzed by different methods at NIST and EC facilities for the determination of concentrations and value assignment of 63 polychlorinated biphenyl (PCB) congeners, 20 organochlorine pesticides, and 11 polybrominated diphenyl ether (PBDE) congeners. The total PCB concentration is approximately 58 ng g(-1) wet mass. Results obtained for analytes not listed on the certificates of analysis of the previously used control materials, HGQA and NIST's Standard Reference Material (SRM) 1946 Lake Superior Fish Tissue, are also presented.

Alaska↗

Analysis of polycyclic aromatic hydrocarbons (PAHs) in environmental samples: a critical review of gas chromatographic (GC) methods.

Polycyclic aromatic hydrocarbons (PAHs) are frequently measured in the atmosphere for air quality assessment, in biological tissues for health-effects monitoring, in sediments and mollusks for environmental monitoring, and in foodstuffs for safety reasons. In contemporary analysis of these complex matrices, gas chromatography (GC), rather than liquid chromatography (LC), is often the preferred approach for separation, identification, and quantification of PAHs, largely because GC generally affords greater selectivity, resolution, and sensitivity than LC. This article reviews modern-day GC and state-of-the-art GC techniques used for the determination of PAHs in environmental samples. Standard test methods are discussed. GC separations of PAHs on a variety of capillary columns are examined, and the properties and uses of selected mass spectrometric (MS) techniques are presented. PAH literature on GC with MS techniques, including chemical ionization, ion-trap MS, time-of-flight MS (TOF-MS), and isotope-ratio mass spectrometry (IRMS), is reviewed. Enhancements to GC, for example large-volume injection, thermal desorption, fast GC, and coupling of GC to LC, are also discussed with regard to the determination of PAHs in an effort to demonstrate the vigor and robustness GC continues to achieve in the analytical sciences.

Journal Article↗

Standard reference materials (SRMs) for determination of organic contaminants in environmental samples.

For the past 25 years the National Institute of Standards and Technology (NIST) has developed certified reference materials (CRMs), known as standard reference materials (SRMs), for determination of organic contaminants in environmental matrices. Assignment of certified concentrations has usually been based on combining results from two or more independent analytical methods. The first-generation environmental-matrix SRMs were issued with certified concentrations for a limited number (5 to 10) of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). Improvements in the analytical certification approach significantly expanded the number and classes of contaminants determined. Environmental-matrix SRMs currently available include air and diesel particulate matter, coal tar, marine and river sediment, mussel tissue, fish oil and tissue, and human serum, with concentrations typically assigned for 50 to 90 organic contaminants, for example PAHs, nitro-substituted PAHs, PCBs, chlorinated pesticides, and polybrominated diphenyl ethers (PBDEs).

Animals↗

Synthetic musk fragrances in environmental Standard Reference Materials.

Synthetic musk fragrances have been measured in water, air, sediments, sewage sludge, and biota worldwide. As the study of the environmental fate and impacts of these compounds progresses, the need for Standard Reference Materials (SRMs) for these compounds to facilitate analytical method improvement and interlaboratory comparisons becomes increasingly important. The National Institute of Standards and Technology (NIST) issues environmental matrix SRMs with certified concentrations for a variety of persistent organic pollutants including polycyclic aromatic hydrocarbons (PAHs), chlorinated pesticides, and polychlorinated biphenyl congeners (PCBs). Until now synthetic musk fragrance concentrations have not been reported in NIST SRMs. The objective of this study was to provide reference values for several commonly detected synthetic musk fragrances in several NIST natural matrix SRMs. In this study five polycyclic musk fragrances [HHCB (1,3,4,6,7,8-hexahydro-4,6,6,7,8,8-hexamethylcyclopenta-gamma-2-benzopyran), AHTN (7-acetyl-1,1,3,4,4,6-hexamethyl-1,2,3,4-tetrahydronaphthalene), ADBI (4-acetyl-1,1-dimethyl-6-tert-butylindane), AHMI (6-acetyl-1,1,2,3,3,5-hexamethylindane), and ATII (5-acetyl-1,1,2,6-tetramethyl-3-isopropylindane] and two nitro musk fragrances [musk xylene (1-tert-butyl-3,5-dimethyl-2,4,6-trinitrobenzene) and musk ketone (4-tert-butyl-3,5-dinitro-2,6-dimethylacetophenone)] were measured in selected environmental SRMs. Gas chromatography-electron impact mass spectrometry (GC/EI-MS) was used for all analyses. HHCB was the most frequently detected synthetic musk fragrance and was detected in SRM 2585 Organic Contaminants in House Dust, SRM 2781 Domestic Sludge, SRM 1974b Organics in Mussel Tissue (Mytilus edulis), and SRM 1947 Lake Michigan Fish Tissue. It was not detected in SRM 1946 Lake Superior Fish Tissue or SRM 1945 Organics in Whale Blubber. Concentrations of HHCB in these SRMs ranged from 1.12 ng/g in SRM 1947 to 92,901 ng/g in SRM 2781. All of the polycyclic musk fragrances were detected in SRM 2781 and all of the target compounds were detected in SRM 2585.

Animals↗

Pressurized liquid extraction in environmental analysis.

A critical evaluation of recent literature utilizing pressurized liquid extraction (PLE) for environmental analysis is presented by compound class. Overall, the extraction efficiency of PLE, using the appropriate solvent, temperature and pressure for extraction, is similar to that of Soxhlet extraction. PLE has been used for some classes of compounds that are thermally labile (e.g., explosives) and may require acidic conditions for extraction (e.g., organometallic compounds). References to recent applications are presented emphasizing studies which utilize unspiked, natural matrices and studies that compare PLE to alternate extraction techniques.

Journal Article↗

Microheterogeneity evaluation of polycyclic aromatic hydrocarbons in particulate standard reference materials.

With the emergence of highly sensitive analytical techniques, the microanalysis of natural-matrix materials employing smaller sample sizes is increasingly more common, which subsequently warrants a homogeneity assessment for the individual components at the appropriate sampling level. Pressurized liquid extraction (PLE) in combination with gas chromatography/mass spectrometry (GC/MS) has been used to determine the sampling constants and evaluate the relative homogeneity of trace levels of polycyclic aromatic hydrocarbons (PAHs) for two previously certified particulate standard reference materials, SRM 1649a Urban Dust and SRM 1650b Diesel Particulate Matter, in the milligram sampling range. Fluoranthene, pyrene, benz[a]anthracene and benzo[e]pyrene within SRM 1650b Diesel Particulate Matter were deemed to be homogeneous, based on relatively small sampling constants (K (S)<100 mg), whereas the larger sampling constants (K (S)>100 mg) obtained for all PAHs in SRM 1649a Urban Dust suggest more material heterogeneity. The material heterogeneity of ten individual PAHs (phenanthrene, anthracene, fluoranthene, pyrene, benz[a]anthracene, benzo[k]fluoranthene, benzo[e]pyrene, benzo[a]pyrene, indeno[1,2,3-cd]pyrene and benzo[ghi]perylene) was also described via nonlinear relationships (i.e., power law) between subsampling error S (s) (%) and sample mass, which are used to predict analyte-specific minimum sample masses that result in a specific level of analytical uncertainty.

Journal Article↗

Persistent organic pollutants in Alaskan ringed seal (Phoca hispida) and walrus (Odobenus rosmarus) blubber.

Since 1987, the Alaska Marine Mammal Tissue Archival Project (AMMTAP) has collected tissues from 18 marine mammal species. Specimens are archived in the National Institute of Standards and Technology's National Biomonitoring Specimen Bank (NIST-NBSB). AMMTAP has collected blubber, liver and/or kidney specimens from a number of ringed seals (Phoca hispida) from the areas near Nome and Barrow, Alaska and walruses (Odobenus rosmarus) from several locations in the Bering Sea. Thirty-three ringed seal and 15 walrus blubber samples from the NIST-NBSB were analyzed for persistent organic pollutants (POPs). The compounds determined included PCBs (28 congeners or congener groups), DDT and related compounds, hexachlorobenzene (HCB), hexachlorocyclohexane isomers (HCHs), chlordanes, dieldrin, and mirex. POP concentrations in ringed seal blubber were significantly higher in Barrow than in Nome when statistically accounting for the interaction of age and gender; HCB, however, was not statistically different between the two locations. Unlike males, POP concentrations and age were not significantly correlated in females probably as a result of lactational loss. POP concentrations in walrus blubber were lower than in ringed seal blubber for SigmaPCBs, chlordanes, and HCHs, but higher for dieldrin and mirex. POP concentrations in ringed seals and walrus from Alaska provide further evidence that the western Arctic tends to have lower or similar POP concentrations compared to the eastern Canadian Arctic.

Adipose Tissue↗

Determination of cyanide in blood by isotope-dilution gas chromatography-mass spectrometry.

BACKGROUND: Cyanide (CN) is a lethal toxin. Quantification in blood is necessary to indicate exposure from many sources, including food, combustion byproducts, and terrorist activity. We describe an automated procedure based on isotope-dilution gas chromatography-mass spectrometry (ID GC/MS) for the accurate and rapid determination of CN in whole blood. METHODS: A known amount of isotopically labeled potassium cyanide (K13C15N) was added to 0.5 g of whole blood in a headspace vial. Hydrogen cyanide was generated through the addition of phosphoric acid, and after a 5-min incubation, 0.5 mL of the headspace was injected into the GC/MS at an oven temperature of -15 degrees C. The peak areas from the sample, 1H12C14N+, at m/z 27, and the internal standard, 1H13C15N+, at m/z 29, were measured, and the CN concentration was quantified by ID. The analysis time was 15 min for a single injection. RESULTS: We demonstrated method accuracy by measuring the CN content of unfrozen whole blood samples fortified with a known amount of CN. Intermediate precision was demonstrated by periodic analyses over a 14-month span. Relative expanded uncertainties based on a 95% level of confidence with a coverage factor of 2 at CN concentrations of 0.06, 0.6, and 1.5 microg/g were 8.3%, 5.4%, and 5.3%, respectively. The mean deviation from the known value for all concentrations was <4%. CONCLUSION: The automated ID GC/MS method can accurately and rapidly quantify nanogram per gram to microgram per gram concentrations of CN in blood.

Ascorbic Acid↗

Determination of polybrominated diphenyl ethers in indoor dust standard reference materials.

Polybrominated diphenyl ethers (PBDEs) have been measured for the first time in three different indoor dust Standard Reference Materials (SRMs) prepared by the National Institute of Standards and Technology (NIST). Two of these, SRM 2583 (Trace Elements in Indoor Dust) and SRM 2584 (Trace Elements in Indoor Dust), have been certified previously for lead and other inorganic constituents. A third, SRM 2585 (Organics in Indoor Dust), is a new indoor dust reference material prepared by NIST which will be certified for various organic compounds (polycyclic aromatic hydrocarbons, pesticides and polychlorinated biphenyls) in 2005 including certified concentrations for 16 individual PBDE congeners and reference values for an additional three PBDE congeners. Dust SRMs were analyzed for 30 PBDE congeners using high-resolution gas chromatography combined with low-resolution mass spectrometry operated in both negative chemical ionization (GC/ECNI-MS) and electron impact ionization (GC/EI-MS) modes. Sensitivity was an order of magnitude higher using GC/ECNI-MS relative to GC/EI-MS. These SRMs have been characterized and compared to the three PBDE commercial products (pentaBDE, octaBDE and decaBDE). PentaBDE and DecaBDE were present in all three SRMs and were the dominant commercial products, making up approximately 33% and 58%, respectively. Recent studies suggest that house dust may be a leading source of human exposure to PBDEs. These SRMs are the first reference materials with certified concentrations for PBDEs, which will aid in validating future measurements of PBDEs in house dust and other similar matrices.

Chromatography, High Pressure Liquid↗

Polybrominated diphenyl ethers in house dust and clothes dryer lint.

Few studies have measured the flame retardants polybrominated diphenyl ethers (PBDEs) in the indoor environment. Here, we report measurements of PBDEs in house dust samples collected from the Washington, D.C. metropolitan area in the United States. Dust samples were analyzed for 22 individual PBDE congeners and our results found PBDEs present in every sample. Concentrations of total PBDEs ranged from 780 ng/g dry mass to 30 100 ng/g dry mass. The dominant congeners observed in the dust samples were congeners associated with the pentaBDE and decaBDE commercial mixtures. Ancillary data were collected on the homes and examined for any correlations with total PBDE concentrations. No correlations were observed with year of house construction, type of flooring (i.e., hardwood vs carpet) or the number of television sets or personal computers in the home. However, a significant inverse correlation (p < 0.05) was observed between the area of the home and the contribution of BDE 209 to the total PBDE concentration in dust. Using estimates of inadvertent dust ingestion (0.02-0.2 g/day) by young children (ages 1-4), we estimate ingestion of total PBDEs to range from 120 to 6000 ng/day. Clothes dryer lint was also sampled and analyzed for PBDEs from five of the homes and were present in all five samples ranging from 480 to 3080 ng/g dry mass. This study demonstrates that PBDEs are prevalent at relatively high concentrations within homes where people, and particularly young children, may be susceptible to exposure.

Age Factors↗

Determination of caffeine, theobromine, and theophylline in standard reference material 2384, baking chocolate, using reversed-phase liquid chromatography.

A rapid and selective isocratic reversed-phase liquid chromatographic method has been developed at the National Institute of Standards and Technology to simultaneously measure caffeine, theobromine, and theophylline in a food-matrix standard reference material (SRM) 2384, Baking Chocolate. The method uses isocratic elution with a mobile phase composition (volume fractions) of 10% acetronitrile/90% water (pH adjusted to 2.5 using acetic acid) at a flow rate of 1.5 mL/min with ultraviolet absorbance detection (274 nm). Total elution time for these analytes is less than 15 min. Concentration levels of caffeine, theobromine, and theophylline were measured in single 1-g samples taken from each of eight bars of chocolate over an eight-day period. Samples were defatted with hexane, and beta-hydroxyethyltheophylline was added as the internal standard. The repeatability for the caffeine, theobromine, and theophylline measurements was 5.1, 2.3, and 1.9%, respectively. The limit of quantitation for all analytes was <100 ng/mL. The measurements from this method were used in the value-assignment of caffeine, theobromine, and theophylline in SRM 2384.

Cacao↗

Three new mussel tissue standard reference materials (SRMs) for the determination of organic contaminants.

Three new mussel tissue standard reference materials (SRMs) have been developed by the National Institute of Standards and Technology (NIST) for the determination of the concentrations of organic contaminants. The most recently prepared material, SRM 1974b, is a fresh frozen tissue homogenate prepared from mussels ( Mytilus edulis) collected in Boston Harbor, Massachusetts. The other two materials, SRMs 2977 and 2978, are freeze-dried tissue homogenates prepared from mussels collected in Guanabara Bay, Brazil and Raritan Bay, New Jersey, respectively. All three new mussel tissue SRMs complement the current suite of marine natural-matrix SRMs available from NIST that are characterized for a wide range of contaminants (organic and inorganic). SRM 1974b has been developed to replace its predecessor SRM 1974a, Organics in Mussel Tissue, for which the supply is depleted. Similarly, SRMs 2977 and 2978 were developed to replace a previously available (supply depleted) freeze-dried version of SRM 1974a, SRM 2974, Organics in Freeze-Dried Mussel Tissue. SRM 1974b is the third in a series of fresh frozen mussel tissue homogenate SRMs prepared from mussels collected in Boston Harbor starting in 1988. SRM 1974b has certified concentration values for 22 polycyclic aromatic hydrocarbons (PAHs), 31 polychlorinated biphenyl congeners (PCBs), and 7 chlorinated pesticides. Reference values are provided for additional constituents: 16 PAHs, 8 PCBs plus total PCBs, 6 pesticides, total extractable organics, methylmercury, and 11 trace elements. PAH concentrations range from about 2 ng g(-1 )dry mass (cyclopenta[ cd]pyrene) to 180 ng g(-1 )dry mass (pyrene). PCB concentrations range from about 2 ng g(-1 )dry mass (PCB 157) to 120 ng g(-1 )dry mass (PCB 153). The reference value for total PCBs in SRM 1974b is (2020 +/- 420) ng g(-1 )dry mass. Pesticide concentrations range from about 4 ng g(-1 )dry mass (4,4'-DDT) to 40 ng g(-1 )dry mass (4,4'-DDE). SRM 2977 has certified values for 14 PAHs, 25 PCB congeners, 7 pesticides, 6 trace elements, and methylmercury. Reference values for 16 additional PAHs and 9 inorganic constituents are provided, and information values are given for 23 additional trace elements. SRM 2978 has certified and reference concentrations for 41 and 22 organic compounds, respectively, and contains contaminant levels similar to those of SRM 1974b. Organic contaminant levels in SRM 2977 (mussels from Guanabara Bay, Brazil) are typically a factor of 2 to 4 lower than those in SRM 1974b and SRM 2978. The organic contaminant concentrations in each new mussel tissue SRM are presented and compared in this paper. In addition, a chronological review of contaminant concentrations associated with mussels collected in Boston Harbor is discussed as well as a stability assessment of SRM 1974a.

Animals↗

Polybrominated diphenyl ether congeners and toxaphene in selected marine standard reference materials.

Polybrominated diphenyl ether (PBDE) congeners and components of the complex mixture toxaphene are stable in the environment and readily bioaccumulated into wildlife and human tissues. PBDEs are presently used in large quantities worldwide as flame retardants in textiles, furniture, computer equipment, and cables. Toxaphene is a complex mixture of chlorinated bornanes and bornenes that was the most heavily used pesticide in the United States until it was banned in 1982; however, some countries continue to use toxaphene. The National Institute of Standards and Technology has quantified PBDE congeners and toxaphene in several available Standard Reference Materials (SRMs) using methods of gas chromatography with electron impact mass spectrometry (GC-EI-MS) and GC negative chemical ionization (NCI) MS, respectively. SRM 1588a Organics in Cod Liver Oil and SRM 1945 Organics in Whale Blubber were examined for PBDE congeners 47, 99, 100, 153, and 154, total toxaphene, and toxaphene congeners 26, 50, and 62. SRM 1946 Lake Superior Fish Tissue was also examined for total toxaphene and toxaphene congeners. The sum of the PBDE congeners (mean, (1 SD) wet basis) for SRM 1945 was 150 ng g(-1) (7 ng g(-1)). The concentration of PBDE 47 in SRM 1588a was 82.7 ng g(-1) (2.8 ng g(-1)). Other PBDEs were detected in SRM 1588a but were not quantified due their low levels. The total toxaphene (wet mass basis) was 1,210 ng g(-1) (127 ng g(-1)), 1,960 ng g(-1) (133 ng g(-1)), and 3,980 ng g(-1) (248 ng g(-1)) in SRMs 1945, 1946, and 1588a, respectively. The values for PBDEs and toxaphene determined in the SRMs, while not certified, indicate that the SRMs will be suitable control materials for PBDE and toxaphene analyses.

Adipose Tissue↗

Two new marine sediment standard reference materials (SRMs) for the determination of organic contaminants.

Two new marine sediment standard reference materials (SRMs), SRM 1941b Organics in Marine Sediment and SRM 1944 New York/New Jersey Waterway Sediment, have been recently issued by the National Institute of Standards and Technology (NIST) for the determination of organic contaminants including polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyl (PCB) congeners, and chlorinated pesticides. Both sediment SRMs were analyzed using multiple analytical methods including gas chromatography/mass spectrometry (GC/MS) on columns with different selectivity, reversed-phase liquid chromatography with fluorescence detection (for PAHs only), and GC with electron capture detection (for PCBs and pesticides only). SRM 1941b has certified concentrations for 24 PAHs, 29 PCB congeners, and 7 pesticides, and SRM 1944 has certified concentrations for 24 PAHs, 29 PCB congeners, and 4 pesticides. Reference concentrations are also provided for an additional 58 (SRM 1941b) and 39 (SRM 1944) PAHs, PCB congeners, and pesticides. SRM 1944, which was collected from multiple sites within New York/New Jersey coastal waterways, has contaminant concentrations that are generally a factor of 10-20 greater than SRM 1941b, which was collected in the Baltimore (Maryland) harbor. These two SRMs represent the most extensively characterized marine sediment certified reference materials available for the determination of organic contaminants.

Environmental Monitoring↗

Filling the AOAC triangle with food-matrix standard reference materials.

Well-characterized reference materials are needed by laboratories in the food testing and nutrition communities to facilitate compliance with nutritional labeling laws, to provide traceability for food exports needed for acceptance in many foreign markets, and to improve the accuracy of nutrition information that is provided to assist consumers in making sound dietary choices. As a result of the enactment of the Nutrition Labeling and Education Act of 1990 and the Infant Formula Act of 1980, the National Institute of Standards and Technology (NIST) has developed a suite of food-matrix Standard Reference Materials (SRMs) characterized for nutrient concentrations. These include SRM 1544 Fatty Acids and Cholesterol in a Frozen Diet Composite, SRM 1546 Meat Homogenate, SRM 1548a Typical Diet, SRM 1566b Oyster Tissue, SRM 1846 Infant Formula, SRM 1946 Lake Superior Fish Tissue, SRM 2383 Baby Food Composite, SRM 2384 Baking Chocolate, SRM 2385 Spinach, and SRM 2387 Peanut Butter. Many of these materials were developed at the request of the food industry to populate a nine-sectored fat-protein-carbohydrate triangle developed by AOAC International. With the completion of SRM 2387, SRMs representing each sector of the triangle are now available. These food-matrix reference materials are intended primarily for validation of analytical methods for the measurement of proximates, fatty acids, vitamins, minerals, and so on in foods of similar composition. They may also be used as "primary control materials" in the value-assignment of in-house, secondary, control materials to confirm accuracy as well as to establish traceability to NIST.

Food Analysis↗

Determination of nitrated polycyclic aromatic hydrocarbons in diesel particulate-related standard reference materials by using gas chromatography/mass spectrometry with negative ion chemical ionization.

Gas chromatography/mass spectrometry (GC/MS) with negative ion chemical ionization (NICI) detection was utilized for quantitative determination of nitrated polycyclic aromatic hydrocarbons (nitro-PAHs) in diesel particulate-related standard reference materials (SRMs). Prior to GC/MS analysis, isolation of the nitro-PAHs from the complex diesel particulate extract was accomplished using solid phase extraction (SPE) and normal-phase liquid chromatographic (LC) fractionation using an amino/cyano stationary phase. Concentrations of eight to ten mononitro-PAHs and three dinitropyrenes were determined in three diesel particulate-related SRMs: SRM 1650a Diesel Particulate Matter, SRM 1975 Diesel Particulate Extract, and SRM 2975 Diesel Particulate Matter (Industrial Forklift). The results from GC/MS NICI using two different columns (5% phenyl methylpolysiloxane and 50% phenyl methylpolysiloxane) were compared to each other and to results from two other laboratories for selected nitro-PAHs. 1-Nitropyrene was the most abundant nitro-PAHs in each of the diesel particulate SRMs (19.8+/-1.1 micro g g(-1) particle in SRM 1650a and 33.1+/-0.6 micro g g(-1) particle in SRM 2975). Three dinitropyrene isomers were measured in SRM 1975 at 0.5-1.4 micro g g(-1) extract and in SRM 2975 at 1-3 micro g g(-1) particle.

Air Pollutants↗