Safe laparoscopic surgery in the elderly.

BACKGROUND: The elderly are more prone to complications of surgery because of comorbidity, and they may benefit most from a minimally invasive approach. This study was intended to evaluate the safety of the use of a laparoscopic approach for emergency and elective surgery in elderly patients. METHODS: From January 2000 to June 2001, all patients over 75 years of age who underwent a procedure that began laparoscopically were included. Physiologic and operative scores according to the POSSUM scoring system were recorded. These were then used to calculate predicted morbidity and mortality by both the POSSUM and P-POSSUM systems. Predicted outcomes were compared with actual outcomes. RESULTS: One hundred sixty-two patients with a mean age of 80 years were included; 52% were emergency cases. The overall morbidity was 14.5% and the mortality rate was 1.8%. Fourteen procedures (8.4%), all emergencies, were converted. Both mortality and morbidity rates were lower than the predicted values (P = 0.001 and P = 0.0001, respectively). CONCLUSIONS: A laparoscopic approach can be used safely in an elderly population undergoing surgery in a daily practice for miscellaneous conditions, whether elective or emergency operations.

Age Factors↗

Three-dimensional virtual cholangioscopy: a reliable tool for the diagnosis of common bile duct stones.

OBJECTIVE: Our goal was to evaluate the clinical reliability of a new software system employing 3-dimensional (3D) virtual anatomic reconstruction and intraluminal virtual exploration for detection of choledocholithiasis and preoperative visualization of the biliary anatomy. SUMMARY BACKGROUND DATA: Virtual reality systems have been proposed for gastroscopy, bronchoscopy, and colonoscopy, as well as for the 3D reconstruction of liver anatomy and hepatic lesions. The impact of these systems in preoperative diagnostics has not been established due to the lack of large clinical series evaluating their reliability. METHODS: From November 2000 to July 2002, all patients presenting to our Institute with suspected choledocholithiasis were prospectively included in the study. All patients underwent conventional magnetic resonance cholangiopancreatography (MRCP) and either intraoperative cholangiogram (IOC) or endoscopic retrograde cholangiopancreatography (ERCP). The digital data from MRCP were incorporated into an original virtual reality software system to generate a 3D reconstruction. All 3D reconstructions were evaluated by a surgeon and a computer software engineer who were blind to the results of the IOC or ERCP. Sensitivity and specificity were then calculated based on the results of either the IOC or ERCP. RESULTS: Sixty-five patients were enrolled in the study. The average time required to reconstruct the images into navigable virtual reality was 7.5 minutes (range, 4-13.5). The 3D virtual cholangioscopy had sensitivity and specificity rates of 71% and 91%, respectively, compared with 61% and 86% of the standard MRCP. CONCLUSION: : The 3D virtual cholangioscopy provides detailed preoperative reconstruction of biliary anatomy and reliable identification of choledocholithiasis with acceptable sensitivity and specificity in a clinical setting. Newer software developments may further enhance its accuracy, so that virtual cholangioscopy might challenge or replace more invasive diagnostic measures in the near future.

Cholangiography↗

Transcontinental robot-assisted remote telesurgery: feasibility and potential applications.

OBJECTIVE: To show the feasibility of performing surgery across transoceanic distances by using dedicated asynchronous transfer mode (ATM) telecommunication technology. SUMMARY BACKGROUND DATA: Technical limitations and the issue of time delay for transmission of digitized information across existing telecommunication lines had been a source of concern about the feasibility of performing a complete surgical procedure from remote distances. METHODS: To verify the feasibility and safety in humans, the authors attempted remote robot-assisted laparoscopic cholecystectomy on a 68-year-old woman with a history of abdominal pain and cholelithiasis. Surgeons were in New York and the patient in Strasbourg. Connections between the sites were done with a high-speed terrestrial network (ATM service). RESULTS: The operation was carried out successfully in 54 minutes without difficulty or complications. Despite a round-trip distance of more than 14,000 km, the mean time lag for transmission during the procedure was 155 ms. The surgeons perceived the procedure as safe and the overall system as perfectly reliable. The postoperative course was uneventful and the patient returned to normal activities within 2 weeks after surgery. CONCLUSIONS: Remote robot-assisted surgery appears feasible and safe. Teletransmission of active surgical manipulations has the potential to ensure availability of surgical expertise in remote locations for difficult or rare operations, and to improve surgical training worldwide.