PubMed Health⌕ Search

Biomedical subjects

Michiel W de Haan

Publications and source records attributed to Michiel W de Haan.

15 recordsLinked to original sources

Impact of a quality improvement programme based on vascular access flow monitoring on costs, access occlusion and access failure.

BACKGROUND: Vascular access thrombosis is a substantial source of morbidity in chronic haemodialysis patients. Periodical access flow measurements can predict the presence of vascular access stenosis and provide an opportunity for early intervention to prevent subsequent vascular access thrombosis. By this system of quality improvement, vascular access-related costs might be reduced. The aim of this study was to analyse the cost impact of a quality improvement programme based on periodic access flow measurements. METHODS: The number and costs of vascular access interventions (summary of angiography, percutaneous transluminal angioplasty, catheter placement, hospitalization days and costs for surgery) in the period 2001-2003 (quality improvement period; QIP, 218.6 patient-years observed) were retrospectively compared with a reference period (RP, 1996-1998, 214.4 patient-years observed) during which no access flow was measured. All access flow measurements were done on a regular base and interventions were performed according to the Kidney Disease Outcome Quality Initiative. RESULTS: Surgical thrombectomy procedures were significantly less during the QIP (0.25 +/- 0.57 events/patient-year) compared with RP (0.63 +/- 1.06 events/patient-year; P = 0.000), whereas access loss was not significantly different. During the QIP, 205 radiological interventions were performed (0.88 +/- 1.16 events/patient-year), and in the RP around 48 (0.33 +/- 0.65 events/patient-year; P = 0.000). Access-related costs tended to be lower during the QIP compared with the RP. The cost reduction appeared to be limited to patients with arteriovenous graft (AVG), in which access-related costs were significantly lower during the QIP (2360.95 euro +/- 2838.17 euro patient-year) compared with the RP (4003.96 euro +/- 3810.92 euro patient-year; P = 0.012), but not in patients with arteriovenous fistula (AVF). CONCLUSION: A quality improvement programme based on periodical access flow measurement reduced the number of acute vascular access failures due to thrombotic events and also significantly reduced health care costs in patients with AVG, but not in patients with AVF. The quality improvement programme had no effect on access survival.

Aged↗

Magnetic resonance angiography of collateral vessel growth in a rabbit femoral artery ligation model.

Collateral vessel growth was visualized in a rabbit femoral artery ligation model by serial contrast-enhanced magnetic resonance angiography (MRA) at 1.5 T in comparison with X-ray angiography (XRA). XRA and MRA were performed directly after femoral artery ligation (day 0+) and after 7 and 21 days. XRA (in-plane resolution, 0.3x0.3 mm) was performed with arterial catheterization for fast injection of iodinated contrast agent just proximal to the aortic bifurcation. MRA (in-plane, 0.6x0.6 mm) was performed at 1.5 T with a five-element phased-array coil and slow injection of gadolinium-based MR contrast agent into an ear vein. Collateral vessel scores on two-dimensional XRA projections and on three-dimensional digitally subtracted rotational MRA maximum intensity projections were obtained by two observers and compared. Collateral vessel counts and minimal detectable vessel diameters for MRA and XRA were combined in a computational flow model to interpret differences in spatial detection limits between imaging modalities in terms of flow. Collateral vessel scores were significantly higher in the ligated limb at day 7 (P < 0.05) and more so at day 21 (P < 0.001), in comparison with day 0+ or in the non-ligated control limb on both XRA and MRA. Significantly more (smaller) vessels were visualized with XRA than with MRA, particularly on day 21 (P < 0.05). Inter-observer agreement was high for both XRA (kappa = 0.82) and MRA (kappa = 0.78). The flow model showed that collateral vessels with diameters > 0.3 mm scored by XRA as well as MRA represent nearly 100% of the total blood flow, whereas smaller (0.1-0.3 mm diameter) vessels that can only be detected with XRA contribute little to the blood flow. Serial contrast-enhanced MRA can non-invasively visualize sub-millimeter collateral vessels that represent nearly 100% of the restored blood flow, in a femoral artery ligation model.

Animals↗

Peripheral arterial disease: clinical and cost comparisons between duplex US and contrast-enhanced MR angiography--a multicenter randomized trial.

PURPOSE: To prospectively determine the clinical and economic consequences of replacing duplex ultrasonography (US) with contrast material-enhanced magnetic resonance (MR) angiography for the initial imaging work-up of patients with peripheral arterial disease (PAD). MATERIALS AND METHODS: This randomized multicenter study was approved by the institutional review board of each hospital, and all patients signed written informed consent prior to randomization. Patients with PAD who needed to undergo imaging work-up and who had an ankle-brachial pressure index (ABPI) of less than 0.90 were recruited by vascular surgeons between January 2002 and September 2003. Patients were randomly assigned to undergo contrast-enhanced MR angiography or duplex US. The primary outcome measure was cost. Secondary outcome measures included therapeutic confidence, changes in disease severity, and changes in quality of life (QOL) assessed during 6 months of follow-up. Indicators for disease severity were based on the Rutherford classification, treadmill walking distance, ABPI at rest, and ABPI after exercise. QOL was assessed with the Rating Scale, Short Form 36, EuroQol-5D, and VascuQol questionnaires. The cost of (additional) imaging procedures, therapeutic interventions, and outpatient visits were calculated from a hospital perspective (ie, all costs incurred inside the hospital were estimated, including physician costs). Data were evaluated by using the Student t test and a multivariable linear regression analysis. RESULTS: At 6 months, 352 patients (239 [68%] men, 113 [32%] women; mean age, 65 years) were analyzed. The use of contrast-enhanced MR angiography versus duplex US reduced the number of additional vascular imaging procedures by 42%; contrast-enhanced MR angiography was also associated with higher therapeutic confidence. Diagnostic costs for contrast-enhanced MR angiography were 167 euros (186 dollars) higher than those for duplex US (P < .001). No statistically significant differences were found for total cost, changes in disease severity, or changes in QOL between patients examined with duplex US and those examined with contrast-enhanced MR angiography (P > .05). CONCLUSION: Replacing duplex US with contrast-enhanced MR angiography for the initial imaging work-up of patients with PAD reduces the need for additional imaging, although diagnostic costs are higher.

Aged↗

Excellent performance of one-stage brachial-basilic arteriovenous fistula.

BACKGROUND: According to the National Kidney Foundation-Dialysis Outcomes Quality Initiative (NKF-DOQI) and the European Guidelines, the first and second choice for vascular access for haemodialysis are the radial-cephalic and brachial-cephalic arteriovenous fistula (AVF). Autogenous fistulas have a longer functional lifetime, less thrombotic complications and a lower infection risk compared with prosthetic implants. If it is impossible to create a brachial-cephalic AVF or after failure, either a brachial-basilic (BB) or a prosthetic forearm loop AVF may be considered. To determine the outcome of BB-AVFs, we retrospectively surveyed the results of this type of vascular access. METHODS: All BB-AVF patient records over a 6 year period were subtracted from an academic hospital registry. Primary failure and primary, assisted primary and secondary patency rates were calculated with the Kaplan-Meier method. Sex, diabetes mellitus (DM), pre-operative duplex diameters, complications and interventions were recorded and correlated with the patency rates. RESULTS: A total of 31 BB-AVFs were created in a one-stage surgical procedure. Of the patients, 36% were male and 19% had DM. Only one patient had a primary failure, leaving 30 (97%) of the BB-AVFs functional for dialysis treatment. Four patients died within 1 year after the operation, one of them from a catheter sepsis. Primary, assisted primary and secondary patency rates after 1 year were, 58, 83 and 90%, respectively. Patient characteristics and pre-operative duplex parameters did not influence patency rates. CONCLUSION: The BB-AVF is an excellent third choice option for vascular access.

Adult↗

Imaging peripheral arterial disease: a randomized controlled trial comparing contrast-enhanced MR angiography and multi-detector row CT angiography.

PURPOSE: To prospectively evaluate clinical utility, patient outcomes, and costs of contrast material-enhanced magnetic resonance (MR) angiography compared with multi-detector row computed tomographic (CT) angiography for initial imaging in the diagnostic work-up of patients with peripheral arterial disease. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Patients referred for diagnostic imaging work-up to evaluate the feasibility of a revascularization procedure were randomly assigned to undergo either MR angiography or CT angiography. Clinical utility was assessed with therapeutic confidence (scale of 0-10) at initial imaging and with the need for additional imaging. Patient outcomes included ankle-brachial index, maximum walking distance, change in clinical status, and health-related quality of life. Actual diagnostic and therapeutic costs were calculated from the hospital perspective. Differences between group means were calculated with unpaired t tests and 95% confidence intervals. RESULTS: A total of 157 consecutive patients with peripheral arterial disease were prospectively randomized to undergo MR angiography (51 men, 27 women; mean age, 63 years) or CT angiography (50 men, 29 women; mean age, 64 years). For one of the 78 patients in the MR group, no data were available. Mean confidence for MR angiography (7.7) was slightly lower than that for CT angiography (8.0, P = .8). During 6 months of follow-up, 13 patients in the MR group compared with 10 patients in the CT group underwent additional vascular imaging (P = .5). Although not statistically significant, there was a consistent trend of less improvement in the MR group across all patient outcomes. The average cost for diagnostic imaging was 359 ($438) higher in the MR group than in the CT group (95% confidence interval: 209, 511 [$255, $623]; P < .001). Therapeutic costs were higher in the MR group, but the difference was not significant. CONCLUSION: The results suggest that CT angiography has some advantages over MR angiography in the initial evaluation of peripheral arterial disease.

Aged↗

Contrast-enhanced peripheral MR angiography using SENSE in multiple stations: feasibility study.

PURPOSE: To investigate if the use of parallel imaging is feasible and beneficial for peripheral contrast-enhanced magnetic resonance angiography (CE-MRA). MATERIALS AND METHODS: A total of 19 consecutive patients underwent peripheral CE-MRA using SENSE with two-fold reduction in the upper and lower leg stations. Conventional nonaccelerated imaging using constant level appearance (CLEAR) was used in the aortoiliac station. The findings were compared with those in a similar patient group that underwent peripheral CE-MR angiography using our standard imaging protocol without SENSE. Intraarterial digital subtraction angiography (IA-DSA) was used as the standard of reference. Lower extremity vessels were divided into anatomic segments (aortoiliac, upper legs, lower legs) for review. In each anatomic segment signal- and contrast-to-noise ratios (SNR, CNR), venous contamination, subjective image quality, as well as sensitivity and specificity, were determined for both patient groups. RESULTS: SNR and CNR improved significantly for the aortoiliac and upper leg segments (all P-values < or = 0.001). Small reductions were seen in the frequency of disturbing venous enhancement (P = not significant). There were no significant differences with regards to subjective image quality or diagnostic accuracy (all P > 0.3). Overall sensitivity and specificity in the SENSE group were 81% and 95%, respectively. For the non-SENSE group, these values were 79% and 96%, respectively. CONCLUSION: Preliminary results show that three-station peripheral CE-MRA using a full length peripheral arterial coil in combination with SENSE in the upper and lower leg stations is feasible and useful for further optimization of peripheral MRA. Using SENSE allows for routine, high-quality depiction of the entire peripheral vascular tree including the pedal arch. Higher SENSE factors are needed for further optimization.

Aged↗

Comparison of generic and disease-specific questionnaires for the assessment of quality of life in patients with peripheral arterial disease.

OBJECTIVE: This study compared the ability of generic and disease-specific questionnaires to assess quality of life (QOL) at baseline and to detect change in QOL after treatment in patients with peripheral arterial disease (PAD). METHODS: This prospective multicenter trial recruited 514 patients with PAD who needed an imaging workup and had an ankle brachial pressure index of less than 0.90. Patients with severe comorbidity were excluded, leaving a study population of 450 patients. Patients completed two generic questionnaires, the Short Form 36 (SF-36) and the European Quality of Life 5D (EuroQol-5D), and one disease-specific questionnaire, the Vascular Quality of Life (VascuQol) at baseline and after 6 months of follow-up. Rutherford classification and treadmill walking distance were determined at baseline and after 6 months of follow-up and were considered indicators of disease severity. Receiver operating characteristic (ROC) curves and areas under the curves (AUCs) were used to evaluate each of the three questionnaires for its ability to discriminate between severe and mild disease at baseline and to discriminate between a large and small change in disease severity after follow-up. The underlying assumption was that disease severity is a major determinant of QOL. This implies that the validity of a QOL questionnaire is reflected by its ability to discriminate between mildly and severely diseased patients. RESULTS: At baseline, 443 patients and after follow-up, 386 patients completed questionnaires. At baseline, no significant ( P >.05) differences were observed among AUCs for the total scores of the three questionnaires, indicating that all three questionnaires assessed the disease severity equally well. After follow-up, the AUCs for the VascuQol were significantly higher than the AUCs for the SF-36 and EuroQol-5D with respect to detection of improvement in Rutherford classification ( P < .05), indicating that change in disease severity after follow-up was best detected by the VascuQol. CONCLUSION: The VascuQol is the preferred questionnaire as outcome measure for QOL in future trials and clinical follow-up of patients with PAD.

Aged↗

Accuracy of semiautomated analysis of 3D contrast-enhanced magnetic resonance angiography for detection and quantification of aortoiliac stenoses.

OBJECTIVES: We sought to compare reproducibility and accuracy of semiautomated stenosis detection and quantification in 3D contrast-enhanced magnetic resonance angiography (CE-MRA) images with conventional evaluation of 3D CE-MRA in patients with peripheral arterial disease (PAD) by using intra-arterial digital subtraction angiography (IA-DSA) as standard of reference. METHODS: Twenty-five patients with PAD underwent CE-MRA and IA-DSA. Three blinded observers independently evaluated CE-MRA datasets for stenoses in the aortoiliac region using semiautomated computer analysis. Semiautomated measurements were compared with conventional measurements of stenosis on CE-MRA datasets, as measured by 3 other independent observers blinded to all other measurements. Interobserver agreement was quantified using kappa (kappa) and intraclass correlation coefficients (ICCs). Sensitivity and specificity were determined for both semiautomated and conventional measurements. RESULTS: Semiautomated measurements were successful in 124 of the 125 arterial segments. The sensitivity of semiautomated measurements was 89% for all observers; specificity varied between 87% and 89%. For conventional measurements of CE-MRA, sensitivity varied between 79% and 86%; specificity was between 86% and 96%. There was good interobserver agreement between all readers for semiautomated measurements (combined kappa for all 3 observers together = 0.78; ICC = 0.82), as well as for conventional measurements (combined kappa = 0.70; and ICC = 0.83). Differences between ICCs, combined kappa values, and accuracy of both measurements were not significant (all P > 0.05). CONCLUSION: Semiautomated analysis of aortoiliac 3D CE-MRA has the same high accuracy for detection and quantification of stenoses as conventional readings of CE-MRA.

Aged↗

Peripheral arterial disease: comparison of color duplex US and contrast-enhanced MR angiography for diagnosis.

PURPOSE: To prospectively compare the diagnostic accuracies of color duplex ultrasonography (US) and contrast material-enhanced magnetic resonance (MR) angiography and to assess interobserver agreement regarding contrast-enhanced MR angiographic findings in patients suspected of having peripheral arterial disease (PAD). MATERIALS AND METHODS: The institutional review board approved the study, and all patients provided signed informed consent. Two hundred ninety-five patients referred for diagnostic and preinterventional work-up of PAD with duplex US also underwent gadolinium-enhanced MR angiography. Data sets were reviewed for presence or absence of 50% or greater luminal reduction, which indicated hemodynamically significant stenosis, and to determine interobserver agreement. At duplex US, a peak systolic velocity ratio of 2.5 or greater indicated significant stenosis. Primary outcome measures were differences between duplex US and contrast-enhanced MR angiography in sensitivity and specificity for detection of significant stenosis, as assessed with the McNemar test, and interobserver agreement between the two contrast-enhanced MR angiogram readings, expressed as quadratic weighted kappa values. Intraarterial digital subtraction angiography (DSA) was the reference standard. RESULTS: Two hundred forty-nine patients had at least one hemodynamically significant stenotic lesion at contrast-enhanced MR angiography, duplex US, or both examinations. One hundred fifty-two patients underwent intraarterial DSA. The quadratic weighted kappa for agreement regarding the presence of 50% or greater stenosis at contrast-enhanced MR angiography was 0.89 (95% confidence interval [CI]: 0.87, 0.91). Sensitivity of duplex US was 76% (95% CI: 69%, 82%); specificity, 93% (95% CI: 91%, 95%); and accuracy, 89%. Sensitivity and specificity of contrast-enhanced MR angiography were 84% (95% CI: 78%, 89%) and 97% (95% CI: 95%, 98%), respectively; accuracy was 94%. Sensitivity (P = .002) and specificity (P = .03) of contrast-enhanced MR angiography were significantly higher. CONCLUSION: Results of this prospective comparison between contrast-enhanced MR angiography and duplex US provide evidence that contrast-enhanced MR angiography is more sensitive and specific for diagnosis and preinterventional work-up of PAD.

Adult↗

Interobserver agreement for the interpretation of contrast-enhanced 3D MR angiography and MDCT angiography in peripheral arterial disease.

OBJECTIVE: The objective of our study was to compare interobserver agreement for interpretations of contrast-enhanced 3D MR angiography and MDCT angiography in patients with peripheral arterial disease. SUBJECTS AND METHODS: Of 226 eligible patients, 69 were excluded. The remaining 157 consecutive patients were prospectively randomized to either MR angiography (n = 78) or MDCT angiography (n = 79). Two observers independently evaluated for arterial stenosis or occlusion on MR angiography (2,157 segments) and MDCT angiography (2,419 segments) using a 5-point ordinal scale. Vessel wall calcifications were noted. Interobserver agreement for each technique was evaluated with a weighted kappa (kappa(w)) statistic. RESULTS: Although interobserver agreement for both was excellent, the interobserver agreement for MR angiography (kappa(w) = 0.90; 95% confidence interval [CI], 0.89-0.92) was higher than that for MDCT angiography (kappa(w) = 0.85; 95% CI, 0.83-0.86) for reporting the degree of arterial stenosis or occlusion in all segments. For the different anatomic locations, the interobserver agreement for MR angiography versus MDCT angiography was as follows: aortoiliac (kappa(w) =0.91 vs 0.84, respectively), femoropopliteal (kappa(w) = 0.91 vs 0.87), and crural (kappa(w) = 0.90 vs 0.83) segments. The interobserver agreement of MDCT angiography significantly decreased in the presence of calcifications but was still good for all anatomic locations. The lowest agreement was found for crural segments in the presence of calcifications (kappa(w) = 0.67). With MR angiography, there were 12 times more nondiagnostic segments than with MDCT angiography (81 vs 7, respectively). CONCLUSION: Interpretations of MR angiography and MDCT angiography for peripheral arterial disease have an excellent interobserver agreement. MR angiography has a higher interobserver agreement than MDCT angiography, and the presence of calcified segments significantly decreases interobserver agreement for MDCT angiography.

Adult↗

Accuracy of computed tomographic angiography and magnetic resonance angiography for diagnosing renal artery stenosis.

BACKGROUND: Timely, accurate detection of renal artery stenosis is important because this disorder may be a potentially curable cause of hypertension and renal impairment. OBJECTIVE: To determine the validity of computed tomographic angiography (CTA) and magnetic resonance angiography (MRA) compared with digital subtraction angiography (DSA) for detection of renal artery stenosis. DESIGN: Prospective multicenter comparative study conducted from 1998 to 2001. Two panels of 3 observers judged CTA and MRA image data and were blinded to all other results. Digital subtraction angiography images were evaluated by consensus. SETTING: 3 large teaching hospitals and 3 university hospitals in the Netherlands. PATIENTS: 402 hypertensive patients with suspected renal artery stenosis were included. A group of 356 patients who underwent all 3 diagnostic tests was used for analysis. MEASUREMENTS: Reproducibility was assessed by calculating interobserver agreement. Diagnostic performance was evaluated in terms of sensitivity, specificity, and other diagnostic variables. Atherosclerotic stenoses of 50% or greater and fibromuscular dysplasia were considered clinically relevant. RESULTS: Twenty percent of patients who underwent all 3 tests had clinically relevant renal artery stenosis. Moderate interobserver agreement was found, with kappa values ranging from 0.59 to 0.64 for CTA and 0.40 to 0.51 for MRA. The combined sensitivity and specificity were 64% (95% CI, 55% to 73%) and 92% (CI, 90% to 95%) for CTA and 62% (CI, 54% to 71%) and 84% (CI, 81% to 87%) for MRA. LIMITATIONS: Eighteen percent of the patients were included nonconsecutively. Digital subtraction angiography may be an imperfect reference test. CONCLUSION: Computed tomographic angiography and MRA are not reproducible or sensitive enough to rule out renal artery stenosis in hypertensive patients. Therefore, DSA remains the diagnostic method of choice. *For a list of the other investigators and research coordinators who participated in RADISH, see the Appendix.

Adult↗

Comparison of contrast-enhanced magnetic resonance angiography and digital subtraction angiography in patients with chronic critical ischemia and tissue loss.

RATIONALE AND OBJECTIVES: To compare the ability of intra-arterial digital subtraction angiography (IA-DSA) and total runoff contrast-enhanced magnetic resonance angiography (CE-MRA) to demonstrate peripheral arterial anatomy, specifically in patients with chronic critical ischemia and tissue loss. MATERIALS AND METHODS: Twenty-three consecutive patients with chronic critical ischemia and tissue loss underwent CE-MRA and IA-DSA within 2 days. Two teams, consisting of an interventional radiologist and vascular surgeon who were blinded to each other's results, determined the number of named arteries (21 segments) and the presence of >/=50% stenosis or occlusion. RESULTS: Compared with IA-DSA, both teams detected significantly more arterial segments with CE-MRA, both above and below the knee (team 1: above knee 7.0 versus 5.2, P = 0.002, and below knee 8.5 versus 5.4, P < 0.001; team 2: above knee 7.1 versus 5.4, P = 0.004, and below knee 8.3 versus 5.9, P < 0.001). Interobserver agreement between the 2 teams with regard to presence of arteries and the presence of stenoses and/or occlusions yielded kappa values of 0.76 (95% confidence interval 0.71-0.81) for IA-DSA and 0.73 (95% confidence interval 0.66-0.80) for CE-MRA. Treatment was changed based on the CE-MRA findings in 8/23 (35%) patients. CONCLUSIONS: In the present study CE-MRA detected more patent arteries than IA-DSA in patients with chronic critical ischemia and tissue loss. CE-MRA can modify the choice of therapeutic strategy in these patients.

Aged↗

Prosthetic femorocrural bypass surgery and adjuvant arteriovenous fistulae.

The use of an adjuvant arteriovenous fistula (AVF) in vascular procedures is controversial. The purpose of this study was to evaluate our experience with this adjunct in femorodistal bypass surgery. Patients who received a prosthetic femorocrural bypass with or without an AVF were studied (n = 56). Risk factors, Doppler and plethysmographic characteristics, and preoperative angiograms were analyzed. Of all prosthetic bypasses anastomosed to a single crural vessel, 75% received an AVF (AVF+, n = 44) whereas 25% did not (AVF-, n = 12). Preoperative ankle/brachial pressures and angiographic outflow scores in both groups were comparable. Successful revascularization doubled ankle/brachial pressure indices and tripled toe pressures. Bypasses with a maximum angiographic outflow score performed better than those with low scores (p <0.05). The overall patency rates after 1, 12, and 24 months were 87%, 62%, and 47%, respectively; an AVF did not influence these numbers although a trend favoring the use of a fistula was present at 1 year (AVF-, 54% vs. AVF+, 64%; p = 0.11). Moreover, 2-year limb salvage was not different between groups (AVF-, 75% vs. AVF+, 68%). The use of an AVF in prosthetic femorodistal bypass surgery does not improve rates of patency and limb salvage in the long term.

Aged↗

Stenosis detection in forearm hemodialysis arteriovenous fistulae by multiphase contrast-enhanced magnetic resonance angiography: preliminary experience.

PURPOSE: To assess the feasibility and accuracy of multiphase contrast-enhanced magnetic resonance angiography (CE-MRA) in patients with dysfunctioning hemodialysis arteriovenous fistulae (AVF), using digital subtraction angiography (DSA) as the standard of reference. MATERIALS AND METHODS: Fifteen patients with dysfunctioning AVF (eight radiocephalic and seven graft AVF) underwent CE-MRA. Dysfunction was defined as a flow decline of more than 25% in 1 month measured by dilutional flow measurements. CE-MRA was performed during injection of 35 mL of gadolinium-DTPA. The CE-MRA sequence consisted of a time-resolved series of 10 scans, each lasting approximately 10 seconds. The technical parameters were TR/TE/FA/voxel = 5.4/1.6/40/3.1 mm(3), and a rectangular surface reception coil was used. All patients were scheduled to undergo DSA at which an intervention was carried out when a stenosis >or=50% was seen. Two observers, unaware of each other's findings and the findings at DSA, quantified the number and degree of stenosis in the failing AVF. Image quality for CE-MRA and DSA was scored on a 3-point scale. The diagnostic performance of CE-MRA was analyzed with receiver-operator characteristic (ROC) analysis. RESULTS: CE-MRA and DSA examinations were performed without side effects in all 15 patients. Image quality was scored significantly better on CE-MRA (observer 1: CE-MRA, 2.0; DSA, 1.3; P =.001; observer 2: CE-MRA, 2.0; DSA, 1.4; P =.002). Interobserver agreement for detection of >or=50% stenosis was 0.81 (95% confidence interval (CI) = 0.71-0.92) for CE-MRA and 0.69 (95% CI = 0.55-0.84) for DSA. ROC analysis revealed a mean area under the curve of 0.78. On the patient level, at the >or=50% threshold, mean sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 100% (95% CI = 69%-100%), 10% (95% CI = 0%-78%), 70% (95% CI = 38%-92%), and 100% (95% CI = 50%-100%), respectively. At the >or=75% threshold, mean sensitivity, specificity, PPV, and NPV were 75% (95% CI = 20%-99%), 78% (95% CI = 39%-98%), 55% (95% CI = 12%-96%), and 89% (95% CI = 52%-100%), respectively. CONCLUSION: CE-MRA is a useful diagnostic tool for detecting stenoses in flow-declined hemodialysis AVF prior to interventional DSA.

Aged↗

Phase-contrast magnetic resonance flow quantification in renal arteries: comparison with 133Xenon washout measurements.

To assess the accuracy of 2D phase-contrast magnetic resonance (2D PC MR) renal artery flow measurements, data obtained with this technique were compared with those acquired with the 133Xenon-washout procedure. In addition, the 2D PC MR flow data were related to functional renal information as derived from selective arterial and venous renin sampling. In 53 patients suspected of having renovascular hypertension, MR angiography of the renal arteries was performed, followed by a 3-step angiographic procedure: (1) selective venous and arterial renin sampling; (2) assessment of the renal blood flow by means of the 133Xenon washout technique, and (3) conventional renal angiography. After initial assessment, 71 kidneys were left for analysis. The overall prevalence of renovascular disease > or =50% stenosis was 18%. Mean renal blood flow as assessed with the 2D PC MR technique showed a significant correlation with the 133Xenon washout flow measurements, with a Pearson correlation coefficient of 0.69 (2-tailed; P<0.01). PC MR blood flow measurements correlated poorly with the presence and/or severity of renovascular disease on conventional angiography (r=0.1, P=0.36). Likewise, no statistically significant correlation with either renal venous renin levels or the renin ratio could be identified. Measurement of renal artery blood flow with the use of a 2D PC MR technique is technically feasible. However, the mean renal artery blood flow correlates poorly with either the presence of renovascular disease on angiography or with renin levels. Further improvement of this technique is necessary before it can be applied on a larger scale.

Adult↗