PubMed Health⌕ Search

Biomedical subjects

Miguel Valcárcel

Publications and source records attributed to Miguel Valcárcel.

At least 19 recordsLinked to original sources

Continuous flow configuration for total hydrocarbons index determination in soils by evaporative light scattering detection.

A continuous flow configuration is proposed for the estimation of the hydrocarbon index in soils using for the first time evaporative light scattering detection (ELSD). The method is based on a membrane-enrichment of the hydrocarbons of interest (C10-C40), which are previously extracted from the soil matrix with a water:hexane mixture using a household microwave oven. The organic supernatant is cleaned-up through silica, evaporated and redissolved in a sodium dodecyl sulphate aqueous solution which is introduced in the loop of an injection valve. The sample, carried by an aqueous stream, passes through a continuous filtration unit fitted with a 1 microm pore size PTFE membrane, where the hydrocarbons are retained while the potential coextracted compounds are wasted. Quantitative elution of the C10-C40 fraction is accomplished by passing an acetone stream through the filter which drives the analytes to the ELSD system for analytical measurement. The detection limit was 1.8 microg ml(-1), the linear range 5-25 microg ml(-1) and the precision 4.3%. The recoveries were between 93 and 97%. The proposed method was also evaluated by attenuated total reflexion-Fourier transform (ATR-FT-IR) analysis of the extracts.

Calibration↗

Containerless reaction monitoring in ionic liquids by means of Raman microspectroscopy.

Reaction monitoring by Raman microspectroscopy in levitated room temperature ionic liquid (RTIL) droplets is reported. Due to their non-volatility, RTIL droplets are well-suited to act as wall-less microreactors. The droplets were produced by a piezoelectric flow-through microdispenser connected to an automated flow injection system and were levitated by an acoustic trap. Taking advantage of the flow system versatility, the sequence of reagents was easily changed to study a model organic reaction: the Knoevenagel condensation. The reaction was followed by Raman microspectrometry and the obtained spectra were analysed using multivariate curve resolution to retrieve the concentration profiles and pure spectra of reactants, intermediates and products involved in the reaction. In addition, information about solvation interactions was obtained by monitoring the desolvation process taking place when a volatile co-solvent evaporated from the droplet.

Journal Article↗

Separation of carbon nanotubes in aqueous medium by capillary electrophoresis.

A robust and reproducible method for the dispersion of carbon nanotubes, either single-walled or multi-walled is presented. Dispersion of nanotubes was achieved as surfactant-coated species of sodium dodecyl sulphate. The addition of small amounts of hydroxypropyl methyl cellulose (HPMC) together with the surfactant, sodium dodecyl sulphate, was found critical to achieve reproducible nanotubes dispersion and to obtain an homogeneous and stable solution. This solution is further analyzed by capillary electrophoresis using a background electrolyte solution containing a polymer, 0.025% (w/v) HPMC solution prepared in 5 mM ammonium acetate at pH 8.03. This electrophoretic method presents a high reproducibility between runs, being an interesting alternative to study nanotube size distribution or characterization after synthesis. In addition, the methodology developed allowed the study of the interaction of the different types of carbon nanotubes with a molecular probe such as pentachlorophenol. This procedure was showed effective to detect small differences on the chemical/physical surface properties of the nanotubes. The different interaction behavior found within the two SWNTs selected was critically discussed.

Electrophoresis, Capillary↗

Association of methanol and water in ionic liquids elucidated by infrared spectroscopy using two-dimensional correlation and multivariate curve resolution.

Water and methanol associations in ionic liquids (ILs) have been studied by means of FTIR spectroscopy. Spectra at different concentrations of water or methanol in ILs were obtained by means of on-line dilution using a flow injection analysis system. Spectral features in the OH stretching region revealed that most of the water and methanol molecules tended to be isolated from each other and to interact with the anion of the IL via H bonding. By means of two-dimensional correlation spectroscopy, the formation of methanol and water dimers was also detected. Multivariate curve resolution was used to recover pure spectra and concentration profiles of the different species. Methanol dimers form at concentrations higher than 0.8% (w/w) in the three studied ILs, 1-ethyl-3-methylimidazolium tetrafluoroborate (emimBF4), 1-butyl-3-methylimidazolium tetrafluoroborate (bmimBF4), and 1-butyl-3-methylimidazolium hexafluorophosphate (bmimPF6). Self-association of water molecules takes place in emimBF4 and bmimBF4 at a molar ratio similar to that of methanol molecules; however, water dimers cannot be detected in bmimPF6, the most hydrophobic IL studied. No evidence was found that bigger water clusters are formed in these ILs at the studied cosolvent concentrations.

Journal Article↗

New supported liquid membrane-capillary electrophoresis in-line arrangement for direct selective analysis of complex samples.

An in-line coupling of a micro-membrane extraction unit, based on supported liquid membrane, with commercially available capillary electrophoresis equipment is described. A main characteristic of this micro-membrane device, made from a simple Eppendorf tube, is that it permits the application of voltage in the acceptor solution to be applied during the extraction process. This has been shown as an alternative to enhance sensitivity, as the analytical signal achieved by applying 10 kV for 20 min was similar to that obtained without the application of voltage and with extraction time of 60 min. In addition, the design has been made permitting both in-line hydrodynamic and electrokinetic sample introduction into the electrophoretic capillary. The analytical potential of the proposed system has been demonstrated by the direct determination of nitroimidazoles from pig liver tissue. The high efficiency of the proposed system allowed the extraction and the determination of the analytes to be performed from a simple tissue homogenate obtained in water. The precision of the analysis of spiked samples, expressed in terms of relative standard deviation, was better than 4.8%.

Animals↗

Microemulsion electrokinetic chromatography separation by using hexane-in-water microemulsions without cosurfactant: comparison with MEKC.

A new hexane-in-water microemulsion was investigated as buffer in microemulsion EKC (MEEKC). At difference with other microemulsions, the addition of cosurfactant was not necessary to stabilize the microemulsion. The proposed microemulsion was successfully used to achieve electrophoretic separation of seven antibiotics including nitroimidazoles, cephapirin and tetracyclines. Selectivity and separation efficiency achieved in MEEKC were compared with MEKC. MEEKC technique proved to be more efficient than MEKC for performing the separation of the analytes and the presence of microemulsions was found to be critical to achieve the separation of tetracyclines. The proposed microemulsion also points out that solvents with high volatility, such as hexane, can be stabilized and used as a microemulsion of SDS.

Anti-Bacterial Agents↗

Determination of mandelic acid enantiomers in urine by derivatization in supercritical carbon dioxide prior to their determination by gas chromatography.

The use of a supercritical carbon dioxide reaction medium for the determination of the (R)- and (S)-enantiomers of mandelic acid (MA) is proposed. The process involves a previous derivatization step under supercritical conditions by which the carboxyl group is esterified with methanol, then followed by acylation of the hydroxyl group in methyl MA with pentafluoropropionic anhydride in the absence of a catalyst. These derivatization steps cause no enantiomeric inversion. The derivatized enantiomers are extracted and quantified by gas chromatography. A BETA DEX 225 capillary column allows the separation of (R)-MA and (S)-MA as pentafluoropropionyl methyl esters with good resolution and precision. The overall method was used to determine both enantiomers in urine samples.

Carbon Dioxide↗

Continuous autoanalyzer for the evaluation of the exhaustion of industrial degreasing baths based on the determination of total grease and surfactant contents.

A continuous flow autoanalyzer for at-line monitoring of total grease and surfactant contents in alkaline degreasing baths is proposed. For this purpose, a simple, robust, automated configuration has been on-line coupled to an universal response detector, such as the evaporative light scattering one. The proposed autoanalyzer constitutes an advantageous alternative to manual procedures and achieves the determination of both indices in ca. 15 min. The parameters thus obtained can be used to evaluate the degree of exhaustion of the bath as therefore allows the timely decision-making about reusability, maintenance or renewal. The fractionation model has been validated using attenuated total reflection-Fourier transform-infrared (ATR-FT-IR) spectroscopy. The potential of the method was realized by applying it to the analysis of 15 real samples obtained from precleaning and cleaning alkaline baths from a production line of a metal industry.

Industrial Waste↗

ATR-FTIR membrane-based sensor for the simultaneous determination of surfactant and oil total indices in industrial degreasing baths.

Monitoring the exhaustion of alkaline degreasing baths is one of the main aspects in metal mechanizing industrial process control. The global level of surfactant, and mainly grease, can be used as ageing indicators. In this paper, an attenuated total reflection-Fourier transform infrared (ATR-FTIR) membrane-based sensor is presented for the determination of these parameters. The system is based on a micro-liquid-liquid extraction of the analytes through a polymeric membrane from the aqueous to the organic solvent layer which is in close contact with the internal reflection element and continuously monitored. Samples are automatically processed using a simple, robust sequential injection analysis (SIA) configuration, on-line coupled to the instrument. The global signal obtained for both families of compounds are processed via a multivariate calibration technique (partial least squares, PLS). Excellent correlation was obtained for the values given by the proposed method compared to those of the gravimetric reference one with very low error values for both calibration and validation.

Metallurgy↗

ATR-FT-IR membrane-based sensor for integrated microliquid-liquid extraction and detection.

A novel straightforward membrane-based sensor, which uses attenuated total reflection Fourier transform infrared (ATR-FT-IR) spectroscopy has been developed. The flow cell designed permits the on-line microliquid-liquid extraction of the target analyte into a organic solvent layer (OSL), which was deposited on the ATR surface using a sequential injection manifold. The aqueous and organic phases are separated via a commercial hydrophobic membrane placed on the PTFE piece of the cell. The main advantage of the proposed device is that the OSL can be created and regenerated in a continuous manner using the automatic manifold without opening the cell. The analytes are enriched into the OSL after diffusion through the membrane, which excludes the typical absorption bands of water. In addition, the behavior of different organic solvents was evaluated in order to increase the applicability and versatility of the proposed system. Finally, the analytical performance of the design was established for the detection and quantitation of Triton X100 in water.

Journal Article↗

Speciation of organometallic compounds in environmental samples by gas chromatography after flow preconcentration on fullerenes and nanotubes.

The development of a simple speciation method for the determination of lead (trimethyllead(I), dimethyllead(II), triethyllead(I), and diethyllead(II)), mercury (methylmercury(I), ethylmercury(I), mercury(II)), and tin (n-butyltin(III), di-n-butyltin(II), tri-n-butyltin(I), tin(IV)) compounds in environmental samples was described. The potential of C70 fullerenes and multiwalled carbon nanotubes (MWNTs) as sorbents was investigated for the first time; this study revealed that there are no significant differences between them in terms of sensitivity, selectivity, precision, and reusability. Comparative studies showed that MWNTs and C60 and C70 fullerenes were superior to graphitized carbon black and RP-C18 for the extraction of the 11 compounds studied. The accuracy of the MWNT method was evaluated from recovery values with two standard reference coastal sediments, and good concordance in the results were obtained. Detection limits of 0.5-2 pg/mL were obtained when using a sorbent column containing 160 mg of MWNTs (sample breakthrough, 50 mL of water). The method was successfully applied to the determination of lead, mercury, and tin compounds in water and coastal sediment samples with satisfactory results.

Chromatography, Gas↗

Autoanalyzer for continuous fractionation and quantitation of the polyphenols content in wines.

A simple continuous flow autoanalyzer for the on-line fractionation of the polyphenols content in wines is proposed. The target compounds are isolated from the matrix by solid-phase extraction on an RP-C18 sorbent column, using selective solvents for the sequential elution of each polyphenol family. Moreover, evaporative light scattering detection (ELSD) is used for the first time for the on-line monitorization of the three polyphenol fractions present in the wine samples. Thus, a single sample injection is required to determine the global concentration of the three selected polyphenol fractions and the whole analysis is completed within a few minutes. Three calibration graphs were constructed for quantitative analysis of the global compounds concentration in every fraction and covered the range 5-300 mg l(-1) (expressed as gallic acid). Average repeatability, expressed as relative standard deviation, was 4%. The proposed autonalyzer was applied to the analysis of a variety of commercial wine samples. The results obtained were compared with those provided by the Folin-Ciocalteau method, being similar in all instances.

Anthocyanins↗

Present and future applications of carbon nanotubes to analytical science.

This article reviews the impact of carbon nanotubes on analytical science, and the main current and future applications of carbon nanotubes in this field. Given that it is necessary to solubilize carbon nanotubes for many applications, we consider the procedures developed to achieve this. The use of carbon nanotubes in analytical chemistry as a target analyte and as an analytical tool is also discussed. Chromatographic and electrophoretic methods used to separate and characterize carbon nanotubes are presented. The use of carbon nanotubes as an analytical tool in filters and membranes, as sorbent material for solid phase extraction, in electrochemical (bio)sensors, and in separation methods is discussed. It is clear that while nanotubes are being tested for use in many different fields, their truly enormous potential has yet to be realized in analytical chemistry.

Biosensing Techniques↗

Miguel Valcárcel, University of Córdoba.

The Analyst profiles Miguel Valcárcel, Full Professor of Analytical Chemistry in the University of Córdoba and recipient of the Solvay Prize for Chemistry (1996) and the Robert Boyle Medal of the Analytical Division of the Royal Society of Chemistry (2004).

Career Choice↗

Direct olive oil authentication: detection of adulteration of olive oil with hazelnut oil by direct coupling of headspace and mass spectrometry, and multivariate regression techniques.

Control of adulteration of olive oil, together with authentication and contamination, is one of the main aspects in the quality control of olive oil. Adulteration with hazelnut oil is one of the most difficult to detect due to the similar composition of hazelnut and olive oils; both virgin olive oil and olive oil are subjected to that kind of adulteration. The main objective of this work was to develop an analytical method able to detect adulteration of virgin olive oils and olive oils with hazelnut oil by means of its analysis by a headspace autosampler directly coupled to a mass spectrometer used as detector (ChemSensor). As no chromatographic separation of the individual components of the samples exists, a global signal of the sample is obtained and employed for its characterization by means of chemometric techniques. Four different crude hazelnut oils from Turkey were employed for the development of the method. Multivariate regression techniques (partial least squares and principal components analysis) were applied to generate adequate regression models. Good values were obtained in both techniques for the parameters employed (standard errors of prediction (SEP) and prediction residual error sum of squares (PRESS)) to evaluate its goodness. With the proposed method, minimum adulteration levels of 7 and 15% can be detected in refined and virgin olive oils, respectively. Once validated, the method was applied to the detection of such adulteration in commercial olive oil and virgin olive oil samples.

Corylus↗

Screening and analytical confirmation of sulfonamide residues in milk by capillary electrophoresis-mass spectrometry.

A new methodology is proposed to automate the monitoring of sulfonamide residues in milk samples. It combines a screening unit for the total amount of sulfonamide with capillary electrophoresis-mass spectrometry (CE-MS) equipment for processing the samples containing a detectable level of sulfonamide. The screening unit consists of continuous-flow system (CFS) to precipitate the proteins connected on-line to the CE-MS equipment, in which a common characteristic ion of all sulfonamides was monitored with the MS detector by flushing the sample through the capillary. The confirmatory method is based on the purification and preconcentration of sulfonamides in a CFS unit and posterior analysis by CE-MS. The sample treatment unit was also on-line connected to the CE-MS equipment. In order to increase sensitivity, the flow rate of the sheath liquid was diminished from 0.5 to 0.2 microL.min(-1) by increasing the content in water from 0 to 50% and the formic acid from 0.5 to 1.5% in this liquid and by applying an overimposed pressure of 5 mbar during the electrophoretic separation. The method allowed the analysis of 30 samples per hour.

Animals↗