Distal embolus protection with an intra-aortic filter during stent-graft repair of a severely atherosclerotic thoracic aortic aneurysm.

PURPOSE: To assess the technical feasibility and efficacy of distal embolus protection with an intra-aortic filter during stent-graft repair in a patient diagnosed with a shaggy aorta. TECHNIQUE: In a 75-year-old man with a severely atherosclerotic thoracic aortic aneurysm, stent-graft repair was combined with transposition of the arch branches to the ascending aorta under thoracotomy. A filtration-type embolus protection device with a nitinol basket and polyester fabric was introduced through a 12-F sheath and opened in the supraceliac aorta during the stent-graft procedure; it was safely pulled back into the sheath after the stent-grafts were implanted. The stent-graft repair was successful, and abundant atheromatous debris was captured in the filter. Neither procedure-related embolic events nor neurological deficits were observed. CONCLUSIONS: Use of the intra-aortic filter device to prevent distal embolism during thoracic stent-graft repairs may be feasible and efficacious in severely atherosclerotic patients.

Aged↗

Phlebosclerotic colitis: imaging-pathologic correlation.

OBJECTIVE: The objective of this study was to analyze the imaging findings of phlebosclerotic colitis in comparison with histologic findings. CONCLUSION: Calcifications and/or obstructions of the veins of the colonic wall and adjacent mesentery and collateral formation, edematous thickening of the colonic wall, and increased density in the fatty tissue of the surrounding mesentery were features of this rare entity. However, in the early stage of the disease, no definite calcification of the affected veins was observed.

Aged↗

Usefulness of grasping a guiding catheter with a loop-snare wire for stent placement into the vertebrobasilar artery.

In cases in which the subclavian artery is severely tortuous or branches with an extremely angulated origin, stent placement in the vertebrobasilar artery on the approach from the femoral artery is often technically difficult. We report two cases in which a stent placement procedure for the vertebrobasilar artery was successfully performed by grasping a guiding catheter with a loop-snare wire. This technique is useful for tortuous arteries or arteries branching with an extremely angulated origin.