Quantitative mapping of basal and vasareactive cerebral blood flow using split-dose 123I-iodoamphetamine and single photon emission computed tomography.

A new method has been developed for diffusible tracers, to quantify CBF at rest and after pharmacological stress from a single session of dynamic scans with dual bolus administration of a radiotracer. The calculation process consisted of three steps, including the procedures of incorporating background radioactivity contaminated from the previous scan. Feasibility of this approach was tested on clinical SPECT studies on 16 subjects. Two sequential SPECT scans, 30 min apart, were carried out on each subject, after each of two split-dose administrations of 111 MBq IMP. Of these, 11 subjects received acetazolamide at 10 min before the second IMP injection. Additional PET scans were also carried out on 6 subjects on a separate day, at rest and after acetazolamide administration. The other 5 subjects were scanned only at rest during the whole study period. Quantitative CBF obtained by this method was in a good agreement with those determined with PET (y(ml/100 g/min)=1.07x(ml/100 g/min)-1.14, r=0.94). Vasareactivity was approximately 40% over the whole cerebral area on healthy controls, which was consistent with a literature value. Reproducibility of CBF determined in the rest-rest study was 1.5+/-5.7%. Noise enhancement of CBF images, particularly the second CBF, was reduced, providing reasonable image quality. Repeat assessment of quantitative CBF from a single session of scans with split-dose IMP is accurate, and may be applied to clinical research for assessing vascular reactivity in patients with chronic cerebral vascular disease.

Aged↗

Database of normal human cerebral blood flow measured by SPECT: II. Quantification of I-123-IMP studies with ARG method and effects of partial volume correction.

UNLABELLED: The limited spatial resolution of SPECT causes a partial volume effect (PVE) and can lead to the significant underestimation of regional tracer concentration in the small structures surrounded by a low tracer concentration, such as the cortical gray matter of an atrophied brain. The aim of the present study was to determine, using 123I-IMP and SPECT, normal CBF of elderly subjects with and without PVE correction (PVC), and to determine regional differences in the effect of PVC and their association with the regional tissue fraction of the brain. METHODS: Quantitative CBF SPECT using 123I-IMP was performed in 33 healthy elderly subjects (18 males, 15 females, 54-74 years old) using the autoradiographic method. We corrected CBF for PVE using segmented MR images, and analyzed quantitative CBF and regional differences in the effect of PVC using tissue fractions of gray matter (GM) and white matter (WM) in regions of interest (ROIs) placed on the cortical and subcortical GM regions and deep WM regions. RESULTS: The mean CBF in GM-ROIs were 31.7 +/- 6.6 and 41.0 +/- 8.1 ml/100 g/min for males and females, and in WM-ROIs, 18.2 +/- 0.7 and 22.9 +/- 0.8 ml/100 g/min for males and females, respectively. The mean CBF in GM-ROIs after PVC were 50.9 +/- 12.8 and 65.8 +/- 16.1 ml/100 g/min for males and females, respectively. There were statistically significant differences in the effect of PVC among ROIs, but not between genders. The effect of PVC was small in the cerebellum and parahippocampal gyrus, and it was large in the superior frontal gyrus, superior parietal lobule and precentral gyrus. CONCLUSION: Quantitative CBF in GM recovered significantly, but did not reach values as high as those obtained by invasive methods or in the H2(15)O PET study that used PVC. There were significant regional differences in the effect of PVC, which were considered to result from regional differences in GM tissue fraction, which is more reduced in the frontoparietal regions in the atrophied brain of the elderly.

Aged↗

Brain and whole body distribution of N-isopropyl-4-iodoamphetamine (I-123) in humans: comparison of radiopharmaceuticals marketed by different companies in Japan.

OBJECTIVE: Iodine-123 (123I)-labeled N-isopropyl-4-iodoamphetamine (IMP) has been used as a cerebral blood flow (CBF) tracer for single-photon emission computed tomography (SPECT). An autoradiographic (ARG) method has been developed for the quantitation of CBF by IMP and SPECT. Two IMPs (IMPA and IMPB) produced by different radiopharmaceutical companies are marketed in Japan. In the present study, whole-body distributions including brain and blood of the two IMPs were compared in the same human subjects. METHODS: Two brain SPECT studies using IMPA or IMPB were performed on separate days in six young healthy men. Whole-body scans were also obtained with a large field-of-view single-head gamma camera. One-point arterial blood sampling was performed at 10 min after injection of IMP to measure both the radioactivity concentrations of whole blood and of octanol-extracted components. RESULTS: No significant differences between the two tracers were observed in body distribution, tracer kinetics in brain, or regional distribution in brain. However, the octanol extraction fraction in blood was significantly different between the two tracers. Radiochemical purity was slightly but significantly different between the tracers. CONCLUSIONS: In the ARG method, arterial input function is determined by calibration of a standard input function with the radioactivity concentration of arterial whole blood. Because the standard input function in the ARG method was obtained using IMPA, the standard input function obtained for IMPB should be used when CBF is calculated by the ARG method with IMPB.

Adult↗

Development of a practical image-based scatter correction method for brain perfusion SPECT: comparison with the TEW method.

PURPOSE: An image-based scatter correction (IBSC) method was developed to convert scatter-uncorrected into scatter-corrected SPECT images. The purpose of this study was to validate this method by means of phantom simulations and human studies with 99mTc-labeled tracers, based on comparison with the conventional triple energy window (TEW) method. METHODS: The IBSC method corrects scatter on the reconstructed image I(mub)AC with Chang's attenuation correction factor. The scatter component image is estimated by convolving I(mub)AC with a scatter function followed by multiplication with an image-based scatter fraction function. The IBSC method was evaluated with Monte Carlo simulations and 99mTc-ethyl cysteinate dimer SPECT human brain perfusion studies obtained from five volunteers. The image counts and contrast of the scatter-corrected images obtained by the IBSC and TEW methods were compared. RESULTS: Using data obtained from the simulations, the image counts and contrast of the scatter-corrected images obtained by the IBSC and TEW methods were found to be nearly identical for both gray and white matter. In human brain images, no significant differences in image contrast were observed between the IBSC and TEW methods. CONCLUSION: The IBSC method is a simple scatter correction technique feasible for use in clinical routine.

Algorithms↗

Effects of tissue heterogeneity on cerebral vascular response to acetazolamide stress measured by an I-123-IMP autoradiographic method with single-photon emission computed tomography.

OBJECTIVES: Single-photon emission computed tomography (SPECT) with iodine-123 (123I)-labeled N-isopropyl-p-iodoamphetamine (IMP) is widely used in measuring the cerebral blood flow (CBF) response to acetazolamide stress for assessment of cerebral vascular reserve. To quantitate CBF by means of SPECT with IMP, an autoradiographic (ARG) method has been developed and is widely used. Because the relation between the brain counts on the SPECT scan and CBF is not linear in the ARG method, a mixture of gray and white matter in a pixel causes errors in the calculation of CBF. In the present study, errors in the calculation of CBF and vascular response to acetazolamide stress by the ARG method due to tissue heterogeneity were estimated by simulation study. Correction for effects of tissue heterogeneity in SPECT data was also attempted. METHODS: Images of gray and white matter fraction were obtained by voxel-based morphometry analysis of magnetic resonance (MR) imaging data set. Ideal CBF images, which were generated from gray and white matter fraction images with assumed blood flow values for gray and white matter, were compared to CBF images generated by the ARG method. Correction for effects of tissue heterogeneity in SPECT data was performed with gray and white matter fraction data obtained from MR images. RESULTS: Systematic underestimation of CBF due to tissue heterogeneity was observed in all brain regions. In the neocortical regions, underestimation by -21% to -16%, -26% to -20%, -31% to -24%, and -35% to -27% was observed for gray and white matter blood flow of 80 and 20, 100 and 25, 120 and 30, and 140 and 35 ml/100 ml/min, respectively. Vascular response was also systematically underestimated in most brain regions. Vascular responses in the neocortical regions ranged from 17% to 20%, from 31% to 37%, and from 42% to 52% when ideal vascular responses were 25%, 50%, and 75%, respectively. After correction for the effects of tissue heterogeneity, values of vascular response to acetazolamide stress ranged from 64% to 116% in the neocortical regions, whereas values obtained by the ARG method ranged from 48% to 52%. CONCLUSION: Underestimation of the vascular response to acetazolamide stress due to tissue heterogeneity should be considered in the estimation of cerebral vascular reserve.

Acetazolamide↗

Contribution of scatter and attenuation compensation to SPECT images of nonuniformly distributed brain activities.

UNLABELLED: Correction of scatter and attenuation is essential for quantitative SPECT. In this work, we evaluated the accuracy gained from a method of transmission-dependent convolution subtraction (TDCS) in the quantitation of activity that is highly concentrated in the striatum (STR). METHODS: SPECT data were acquired from an (123)I-containing phantom with a constant activity in the STR but differing background (BKG) activities, so as to simulate various STR/BKG ratios (19.7:1, 9.7:1, 4.8:1, 1.9:1, and 1:1). In a study of healthy humans (n = 6), a transmission scan followed by an emission scan was performed 24 h after injection of (123)I-2beta-carbomethoxy-3beta-(4-iodophenyl)-tropane ((123)I-beta-CIT). All SPECT data was reconstructed with ordered-subset expectation maximization. TDCS was applied for scatter correction. Values of activity in the STR and occipital lobe (for BKG) were used to calculate binding potential V(3)" (= [STR - BKG]/BKG). The effect of SPECT collimator dependency on scatter correction was also evaluated for 6 collimators from 3 different SPECT cameras in the phantom experiment. RESULTS: Scatter correction in the phantom experiment increased the measured values of STR activity (36.2%), resulting in a substantial increase in V(3)" (66.1%). Scatter and attenuation corrections with recovery correction showed an overall bias of -7.3% for the STR, -4.0% for BKG activity, and -7.8% for V(3)". TDCS corrections of phantom activities were relatively uniform for the 6 different collimators, with variabilities of <5.5% for the STR and <3.0% for BKG activities. TDCS correction of human (123)I-beta-CIT images was of a similar, although slightly larger, magnitude than for the phantom data, with increased V(3)" values of 9.4 +/- 2.3 and 4.9 +/- 0.6, with and without scatter correction, respectively. CONCLUSION: The TDSC method significantly improved the accuracy of SPECT images with a nonuniform distribution of activity highly concentrated in central regions. The value of V(3)" was significantly increased in phantom and human data, with most of the improvement derived from an increase in STR activity. This scatter correction method was approximately equally useful with data from the 6 different collimators and is recommended for more accurate quantitation of nonuniformly distributed brain activities.

Adult↗

Evaluation of a commercial PET tomograph-based system for the quantitative assessment of rCBF, rOEF and rCMRO2 by using sequential administration of 15O-labeled compounds.

The purpose of this study was to develop a reliable and practical strategy that generates quantitative CBF and OEF maps accurately from PET data sets obtained with 15O-tracers. Sequential sinogram data sets were acquired after the administration of 15O-tracers, and combined single-frame images were obtained. The delay time between sampled input function and the brain was estimated from the H2(15)O study with the whole brain and the arterial time-activity curves (TACs). The whole-brain TACs were obtained from the reconstructed images (image-base method) and the sinogram data (sinogram-base method). Six methods were also evaluated for the dead-time and decay correction procedures in the process of generating a single-frame image from the dynamic sinogram. The estimated delay values were similar with both the sinogram-based and image-based methods. A lumped correction factor to a previously added single-frame sinogram caused an underestimation of CBF, OEF and CMRO2 by 16% at maximum, as compared with the correction procedure for a short sinogram. This suggested the need for a dynamic acquisition of a sinogram with a short interval. The proposed strategy provided an accurate quantification of CBF and OEF by PET with 15O-tracers.

Adult↗