PubMed Health⌕ Search

Biomedical subjects

Mikael Kubista

Publications and source records attributed to Mikael Kubista.

17 recordsLinked to original sources

LightUp probes in clinical diagnostics.

The LightUp Probe technology has now matured and reached the phase where it has been implemented in commercial reagent kits, i.e. the ReSSQ product line. Several properties of the LightUp probes make them particularly suitable for clinical settings. For instance, extraordinary shelf life and a chemical stability that allows convenient fridge storage. The origin of the higher stability of LightUp probe kits compared to others, based on alternative probe technologies, is partly the relatively good stability of cyanine dyes but also the resistance towards nucleases and proteases of the synthetic DNA analogue peptide nucleic acid that is used as the sequence recognizing element in LightUp probes. It is clear from recent trends in the PCR amplification hardware technology that the instrumentation is becoming more flexible and less adapted for dedicated probe chemistries. This will pave the way for increased standardization in the field of DNA diagnostics and the development of cross-platform assays. In the present review the LightUp technology will briefly be presented and discussed. The utility of the technology will be illustrated by examples from cytomegalovirus quantification and monitoring of the viral load of the SARS Coronavirus. An example of cancer diagnostics by detection of altered gene expression patterns will also be shown.

DNA Probes↗

Spectrophotometric and thermodynamic study on the dimerization equilibrium of ionic dyes in water by chemometrics method.

The monomer-dimer equilibrium and thermodynamic of several ionic dyes (Neutral Red, Nile Blue A, Safranine T and Thionine) has been investigated by means of spectrophotometric and chemometrics methods. The dimerization constants of these ionic dyes have been determined by studying the dependence of their absorption spectra on the temperature in the range 20-75 degrees C at concentrations of Neutral Red (1.73 x 10(-5) M), Nile Blue A (3.94 x 10(-5) M), Safranine (6.59 x 10(-5) M) and Thionine (6.60 x 10(-5) M). The monomer-dimer equilibrium of these dyes has been determined by chemometrics refinement of the absorption spectra obtained by thermometric titrations performed. The processing of the data carried out for quantitative analysis of undefined mixtures, based on simultaneous resolution of the overlapping bands in the whole set of absorption spectra. The enthalpy and entropy of the dimerization reactions were determined from the dependence of the equilibrium constants to the temperature (van't Hoff equation).

Dimerization↗

The real-time polymerase chain reaction.

The scientific, medical, and diagnostic communities have been presented the most powerful tool for quantitative nucleic acids analysis: real-time PCR [Bustin, S.A., 2004. A-Z of Quantitative PCR. IUL Press, San Diego, CA]. This new technique is a refinement of the original Polymerase Chain Reaction (PCR) developed by Kary Mullis and coworkers in the mid 80:ies [Saiki, R.K., et al., 1985. Enzymatic amplification of beta-globin genomic sequences and restriction site analysis for diagnosis of sickle cell anemia, Science 230, 1350], for which Kary Mullis was awarded the 1993 year's Nobel prize in Chemistry. By PCR essentially any nucleic acid sequence present in a complex sample can be amplified in a cyclic process to generate a large number of identical copies that can readily be analyzed. This made it possible, for example, to manipulate DNA for cloning purposes, genetic engineering, and sequencing. But as an analytical technique the original PCR method had some serious limitations. By first amplifying the DNA sequence and then analyzing the product, quantification was exceedingly difficult since the PCR gave rise to essentially the same amount of product independently of the initial amount of DNA template molecules that were present. This limitation was resolved in 1992 by the development of real-time PCR by Higuchi et al. [Higuchi, R., Dollinger, G., Walsh, P.S., Griffith, R., 1992. Simultaneous amplification and detection of specific DNA-sequences. Bio-Technology 10(4), 413-417]. In real-time PCR the amount of product formed is monitored during the course of the reaction by monitoring the fluorescence of dyes or probes introduced into the reaction that is proportional to the amount of product formed, and the number of amplification cycles required to obtain a particular amount of DNA molecules is registered. Assuming a certain amplification efficiency, which typically is close to a doubling of the number of molecules per amplification cycle, it is possible to calculate the number of DNA molecules of the amplified sequence that were initially present in the sample. With the highly efficient detection chemistries, sensitive instrumentation, and optimized assays that are available today the number of DNA molecules of a particular sequence in a complex sample can be determined with unprecedented accuracy and sensitivity sufficient to detect a single molecule. Typical uses of real-time PCR include pathogen detection, gene expression analysis, single nucleotide polymorphism (SNP) analysis, analysis of chromosome aberrations, and most recently also protein detection by real-time immuno PCR.

Animals↗

Combining sequence-specific probes and DNA binding dyes in real-time PCR for specific nucleic acid quantification and melting curve analysis.

Currently, in real-time PCR, one often has to choose between using a sequence-specific probe and a nonspecific double-stranded DNA (dsDNA) binding dye for the detection of amplified DNA products. The sequence-specific probe has the advantage that it only detects the targeted product, while the nonspecific dye has the advantage that melting curve analysis can be performed after completed amplification, which reveals what kind of products have been formed. Here we present a new strategy based on combining a sequence-specific probe and a nonspecific dye, BOXTO, in the same reaction, to take the advantage of both chemistries. We show that BOXTO can be used together with both TaqMan probes and locked nucleic acid (LNA) probes without interfering with the PCR. The probe signal reflect formation of target product, while melting curve analysis of the BOXTO signal reveals primer-dimer formation and the presence of any other anomalous products.

DNA↗

Monitoring differentiation of human embryonic stem cells using real-time PCR.

There is a general lack of rapid, sensitive, and quantitative methods for the detection of differentiating human embryonic stem cells (hESCs). Using light microscopy and immunohistochemistry, we observed that morphological changes of differentiating hESCs precede any major alterations in the expression of several commonly used hESC markers (SSEA-3, SSEA-4, TRA-1-60, TRA-1-81, Oct-4, and Nanog). In an attempt to quantify the changes during stochastic differentiation of hESCs, we developed a robust and sensitive multi-marker quantitative real-time polymerase chain reaction (QPCR) method. To maximize the sensitivity of the method, we measured the expression of up- and downregulated genes before and after differentiation of the hESCs. Out of the 12 genes assayed, we found it clearly sufficient to determine the relative differentiation state of the cells by calculating a collective expression index based on the mRNA levels of Oct-4, Nanog, Cripto, and alpha-fetoprotein. We evaluated the method using different hESC lines maintained in either feeder-dependent or feeder-free culture conditions. The QPCR method is very flexible, and by appropriately selecting reporter genes, the method can be designed for various applications. The combination of QPCR with hESC-based technologies opens novel avenues for high-throughput analysis of hESCs in, for example, pharmacological and cytotoxicity screening.

Biomarkers↗

Development and evaluation of three real-time immuno-PCR assemblages for quantification of PSA.

Real-time PCR is a very sensitive technique to measure DNA concentrations. In real-time immuno-PCR, it is used as the detection system for quantification of proteins. Many ways to perform and assemble real-time immuno-PCR are possible. We have tested three different approaches for the detection of prostate specific antigen (PSA) and compared them with each other and with ELISA. We also demonstrate the applicability of real-time immuno-PCR to classify clinical PSA samples. Assemblage I is performed stepwise attaching the capture antibody to the vessel surface by adsorption and having the DNA-label linked to the detection antibody through biotin and streptavidin. In assemblage II, capture antibody is also adsorbed to the vessel surface but the detection antibody is pre-conjugated to the DNA-label. Assemblage III uses the pre-conjugated detection antibody/DNA-label but binds the capture antibody through biotin to surface immobilized streptavidin. We found assemblage II to be the most sensitive, with a detection limit of 4.8 x 10(5) PSA molecules. This can be compared to the detection limit of the ELISA, which is 5.7 x 10(7) molecules. Assemblage III was the most reproducible with a standard deviation (SD) of 0.21 cycles, while assemblage I was the least reproducible (SD=0.45 cycles). The SD of assemblage II was 0.25 cycles. We conclude that using pre-conjugated detection antibody/DNA-label enhances both the sensitivity and the reproducibility of real-time immuno-PCR. Measurements of PSA in serum samples using real-time immuno-PCR correlated well with measurements performed with ELISA. The real-time immuno-PCR measurements were more sensitive and the dynamic range was larger than with the ELISA.

Antibodies↗

Thermodynamics study of the dimerization equilibria of rhodamine B and 6G in different ionic strengths by photometric titration and chemometrics method.

The dimerization constants of rhodamine B and 6G have been determined by studying the dependence of their absorption spectra on the temperature in the range 20-80 degrees C at different total concentrations of rhodamine B (5.89 x 10(-6) to 2.36 x 10(-4)M) and rhodamine 6G (2.34 x 10(-5) to 5.89 x 10(-4)M) and in different concentrations of LiCl, NaCl and KCl salts as supporting electrolytes. The monomer-dimer equilibrium of rhodamine B and 6G have been determined by chemometrics refinement of the absorption spectra obtained by thermometric titrations performed at different ionic strengths. The quantitative analysis of the data of undefined mixtures, was carried out by simultaneous resolution of the overlapping spectral bands in the whole set of absorption spectra. The dimerization constants are varied by changing the ionic strength and the degree of dimerization are decreased by increasing of the ionic strength of the medium. The enthalpy and entropy of the dimerization reactions were determined from the dependence of the equilibrium constants on the temperature (van't Hoff equation). From the thermodynamic results the TDeltaS degrees -DeltaH degrees plot was sketched. It shows a fairly good positive correlation which indicates the enthalpy-entropy compensation in the dimerization reactions (compensation effect).

Computers↗

Gene expression profiling in single cells from the pancreatic islets of Langerhans reveals lognormal distribution of mRNA levels.

The transcriptional machinery in individual cells is controlled by a relatively small number of molecules, which may result in stochastic behavior in gene activity. Because of technical limitations in current collection and recording methods, most gene expression measurements are carried out on populations of cells and therefore reflect average mRNA levels. The variability of the transcript levels between different cells remains undefined, although it may have profound effects on cellular activities. Here we have measured gene expression levels of the five genes ActB, Ins1, Ins2, Abcc8, and Kcnj11 in individual cells from mouse pancreatic islets. Whereas Ins1 and Ins2 expression show a strong cell-cell correlation, this is not the case for the other genes. We further found that the transcript levels of the different genes are lognormally distributed. Hence, the geometric mean of expression levels provides a better estimate of gene activity of the typical cell than does the arithmetic mean measured on a cell population.

Animals↗

Quantitative real-time PCR for cancer detection: the lymphoma case.

Advances in the biologic sciences and technology are providing molecular targets for diagnosis and treatment of cancer. Lymphoma is a group of cancers with diverse clinical courses. Gene profiling opens new possibilities to classify the disease into subtypes and guide a differentiated treatment. Real-time PCR is characterized by high sensitivity, excellent precision and large dynamic range, and has become the method of choice for quantitative gene expression measurements. For accurate gene expression profiling by real-time PCR, several parameters must be considered and carefully validated. These include the use of reference genes and compensation for PCR inhibition in data normalization. Quantification by real-time PCR may be performed as either absolute measurements using an external standard, or as relative measurements, comparing the expression of a reporter gene with that of a presumed constantly expressed reference gene. Sometimes it is possible to compare expression of reporter genes only, which improves the accuracy of prediction. The amount of biologic material required for real-time PCR analysis is much lower than that required for analysis by traditional methods due to the very high sensitivity of PCR. Fine-needle aspirates and even single cells contain enough material for accurate real-time PCR analysis.

Biomarkers, Tumor↗

Properties of the reverse transcription reaction in mRNA quantification.

BACKGROUND: In most measurements of gene expression, mRNA is first reverse-transcribed into cDNA. We studied the reverse transcription reaction and its consequences for quantitative measurements of gene expression. METHODS: We used SYBR green I-based quantitative real-time PCR (QPCR) to measure the properties of reverse transcription reaction for the beta-tubulin, glyceraldehyde-3-phosphate dehydrogenase, Glut2, CaV1D, and insulin II genes, using random hexamers, oligo(dT), and gene-specific reverse transcription primers. RESULTS: Experimental variation in reverse transcription-QPCR (RT-QPCR) was mainly attributable to the reverse transcription step. Reverse transcription efficiency depended on priming strategy, and the dependence was different for the five genes studied. Reverse transcription yields also depended on total RNA concentration. CONCLUSIONS: RT-QPCR gene expression measurements are comparable only when the same priming strategy and reaction conditions are used in all experiments and the samples contain the same total amount of RNA. Experimental accuracy is improved by running samples in (at least) duplicate starting with the reverse transcription reaction.

Animals↗

Determination of protolytic constants by trilinear fluorescence spectroscopy.

Protolytic equilibria often have profound effects on chemical activity, since protolytic species usually behave quite differently. It is therefore important to characterize the protolytic properties of important chemicals. Here we present a new approach to study protolytic equilibria of fluorescent species that is extremely accurate and relies on minimum assumptions. We show that by measuring 2-dimensional excitation/emission scans of samples at different pH. the 3-dimensional experimental data set, I(lambda(ex), lambda(em), C(pH)), can be unambiguously decomposed into the spectral responses of the protolytic species present as well as their concentration. The approach is demonstrated on the protolytic equilibrium of fluorescein. Although the fluorescein monoanion cannot be obtained in pure form, the spectra and concentrations of both fluorescein species, as well as the protolytic constant, are determined with excellent accuracy. The proposed method is general and can be applied not only for studies of protolytic equilibria, but on any chemical equilibria and chemical reactions involving fluorescent species.

Fluorescein↗

Kinetic Outlier Detection (KOD) in real-time PCR.

Real-time PCR is becoming the method of choice for precise quantification of minute amounts of nucleic acids. For proper comparison of samples, almost all quantification methods assume similar PCR efficiencies in the exponential phase of the reaction. However, inhibition of PCR is common when working with biological samples and may invalidate the assumed similarity of PCR efficiencies. Here we present a statistical method, Kinetic Outlier Detection (KOD), to detect samples with dissimilar efficiencies. KOD is based on a comparison of PCR efficiency, estimated from the amplification curve of a test sample, with the mean PCR efficiency of samples in a training set. KOD is demonstrated and validated on samples with the same initial number of template molecules, where PCR is inhibited to various degrees by elevated concentrations of dNTP; and in detection of cDNA samples with an aberrant ratio of two genes. Translating the dissimilarity in efficiency to quantity, KOD identifies outliers that differ by 1.3-1.9-fold in their quantity from normal samples with a P-value of 0.05. This precision is higher than the minimal 2-fold difference in number of DNA molecules that real-time PCR usually aims to detect. Thus, KOD may be a useful tool for outlier detection in real-time PCR.

Algorithms↗

A new minor groove binding asymmetric cyanine reporter dye for real-time PCR.

The minor groove binding asymmetric cyanine dye 4-[(3-methyl-6-(benzothiazol-2-yl)-2,3-dihydro- (benzo-1,3-thiazole)-2-methylidene)]-1-methyl-pyridin ium iodide (BEBO) is tested as sequence non- specific label in real-time PCR. The fluorescence intensity of BEBO increases upon binding to double-stranded DNA allowing emission to be measured at the end of the elongation phase in the PCR cycle. BEBO concentrations between 0.1 and 0.4 micro M generated sufficient fluorescence signal without inhibiting the PCR. A comparison with the commonly used reporter dye SYBR Green I shows that the two dyes behave similarly in all important aspects.

Animals↗

Quantitative real-time PCR method for detection of B-lymphocyte monoclonality by comparison of kappa and lambda immunoglobulin light chain expression.

BACKGROUND: An abnormal IgLkappa:IgLlambda ratio has long been used as a clinical criterion for non-Hodgkin B-cell lymphomas. As a first step toward a quantitative real-time PCR-based multimarker diagnostic analysis of lymphomas, we have developed a method for determination of IgLkappa:IgLlambda ratio in clinical samples. METHODS: Light-up probe-based real-time PCR was used to quantify IgLkappa and IgLlambda cDNA from 32 clinical samples. The samples were also investigated by routine immunohistochemical analysis and flow cytometry. RESULTS: Of 32 suspected non-Hodgkin lymphoma samples analyzed, 28 were correctly assigned from real-time PCR measurements assuming invariant PCR efficiencies in the biological samples. Four samples were false negatives. One was a T-cell lymphoma, one was a diffuse large B-cell lymphoma, and one was reanalyzed and found lymphoma-positive by in situ calibration, which takes into account sample-specific PCR inhibition. Twelve of the samples were fine-needle aspirates, and these were all correctly assigned. CONCLUSIONS: This work is a first step toward analyzing clinical samples by quantitative light-up probe-based real-time PCR. Quantitative real-time PCR appears suitable for high-throughput testing of cancers by measuring expression of tumor markers in fine-needle aspirates.

Algorithms↗

Neural cell adhesion molecule-deficient beta-cell tumorigenesis results in diminished extracellular matrix molecule expression and tumour cell-matrix adhesion.

To understand by which mechanism neural cell adhesion molecule (N-CAM) limits beta tumour cell disaggregation and dissemination, we searched for potential downstream genes of N-CAM during beta tumour cell progression by gene expression profiling. Here, we show that N-CAM-deficient beta-cell tumorigenesis is associated with changes in the expression of genes involved in cell-matrix adhesion and cytoskeletal dynamics, biological processes known to affect the invasive and metastatic behaviour of tumour cells. The extracellular matrix (ECM) molecules emerged as the primary target, i.e. N-CAM deficiency resulted in down-regulated mRNA expression of a broad range of ECM molecules. Consistent with this result, deficient deposition of major ECM stromal components, such as fibronectin, laminin 1 and collagen IV, was observed. Moreover, N-CAM-deficient tumour cells displayed defective matrix adhesion. These results offer a potential mechanism for tumour cell disaggregation during N-CAM-deficient beta tumour cell progression. Prospective consequences of these findings for the role of N-CAM in beta tumour cell dissemination are discussed.

Animals↗